Radiol. bras ; 43(2): 109-112, mar.-abr. 2010. ilus
Artículo en Inglés, Portugués | LILACS | ID: lil-551818

RESUMEN

OBJETIVO: A biópsia vácuo-assistida é a forma percutânea de biópsia de microcalcificações que obtém a menor taxa de subestimação, porém, seu custo é alto, havendo interesse em se conseguir formas mais baratas de biópsia vácuo-assistida. O objetivo deste trabalho foi testar um dispositivo portátil de biópsia vácuo-assistida que apresenta custo menor. MATERIAIS E MÉTODOS: Foram biopsiadas 35 pacientes que apresentavam agrupamentos de microcalcificações BI-RADS® 4 ou 5. Foram testados a representatividade dos fragmentos colhidos, as dificuldades na reintrodução da cânula e o número de ciclos de colheita. RESULTADOS: Houve obtenção de calcificações representativas em todas as pacientes. Não houve discordância anatomorradiológica, dificuldade na reintrodução da cânula ou complicações graves. CONCLUSÃO: Os dados permitem concluir que o sistema apresenta boa eficácia na obtenção das amostras e com relação de custo-benefício favorável em relação a outros sistemas para a biópsia de microcalcificações, achados em concordância com outras publicações da literatura.


OBJECTIVE: Vacuum-assisted biopsy is the percutaneous technique of breast biopsy with the lowest underestimation rate. However, the cost of such procedure is high and currently there is a considerable interest in developing less expensive techniques. The present study was aimed at testing a less expensive device for vacuum-assisted biopsy of breast microcalcifications. MATERIALS AND METHODS: Thirty-five patients with clustered microcalcifications classified as BI-RADS® 4 or 5 were submitted to biopsy. Collected specimen appropriateness, difficulties in the reinsertion of the cannula and number of biopsy passes were evaluated. RESULTS: Successful specimens collection was achieved in all of the patients. Histo-radiological disagreement, difficulties in the cannula reinsertion or severe complications were not observed. CONCLUSION: The authors conclude that the method is effective in terms of specimens appropriateness and cost-benefit ratio as compared with of biopsy techniques for breast microcalcifications. Such findings are compatible with data reported in the literature.


Asunto(s)
Humanos , Femenino , Persona de Mediana Edad , Calcinosis/patología , Equipos y Suministros , Mama/patología , Biopsia , Técnicas Histológicas , Mamografía , Vacio
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA