Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Añadir filtros








Intervalo de año
1.
Journal of Korean Society of Medical Informatics ; : 109-116, 2009.
Artículo en Coreano | WPRIM | ID: wpr-83079

RESUMEN

OBJECTIVE: The purpose of this study was to verify the algorithm on bio-signals for a home-health management system. METHODS: A methodological study was done to verify the blood pressure and blood sugar algorithm to deliver tailored patient information. The verifying process was as follows: Step 1; development of the algorithm through a literature review, Step 2; programming the algorithm using Microsoft SQL Server 2005 and Visual Studio 2005, Step 3; Reviewing of the algorithm by examining results from the home-health management system and experts' evaluation Step 4; evaluating the agreement of the algorithm by comparison between results from the home-health management system and intended results using bio-signal data set, and completion of the algorithm. RESULTS: Discordance rate between results from the home-health management system and intended results for blood pressure and blood sugar were 5.72% and 2.04%, respectively. Also, discordance rate between results from the home-health management system and experts' evaluation of blood pressure and blood sugar were 30.38% and 20.41%, respectively. All discordance were revised until all the researchers reached agreement. CONCLUSION: The home-health management system with an accurate algorithm on bio-signals can contribute to promote clients' health and reduce the cost of medical services.


Asunto(s)
Humanos , Glucemia , Presión Sanguínea , Conjunto de Datos , Métodos
2.
Journal of Korean Society of Medical Informatics ; : 303-309, 2008.
Artículo en Inglés | WPRIM | ID: wpr-168679

RESUMEN

OBJECTIVES: In order to devise the combination module transmitting bio signal and signal data remotely, as defect of wirewireless combination module was complemented by designing a single combination of wireless module and power supply module, a single system was implemented. METHODS: Currently in case of wireless transmission, it had various problems causing by some factors such as buildings, obstruction, and entanglement of wires and so on. In order to overcome problems of wireless transmission, a single combination module design was researched, which transmits vital signal and sign data using basic electric line installed in the inner building or between others. Even though it was also possible of wireless communication and the internet, in case of a power supply without them, it could be possible to transfer data to underground or top ground in the inner building without any special communication line. RESULTS: Bio signal data was transmitted through a power supply line, a noise problem occurred would be solved by the designed noise filter. The filter showed that noise was cut off about more than 90%. It was also confirmed that the used ECG signals was stably received on transmission experiment. An internal PCB antenna could make the system be wireless communication without the disclosure of an antenna. CONCLUSIONS: In this study, in order to implement a useful system transmitting bio signal and data through wire and wireless management for combination design of wireless module and electrical line module, bio signal transmission system was implemented by design of noise break filter circuit to reduce power noise and PCB internal antenna design.


Asunto(s)
Proteínas del Sistema Complemento , Revelación , Suministros de Energía Eléctrica , Electrocardiografía , Internet , Ruido , Signos Vitales
SELECCIÓN DE REFERENCIAS