Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 121
Filtrar
1.
Arq. bras. cardiol ; 121(1): e20230179, jan. 2024. tab, graf
Artículo en Portugués | LILACS-Express | LILACS | ID: biblio-1533735

RESUMEN

Resumo Fundamento: O prolongamento do intervalo PQ, geralmente associado a um atraso na condução atrioventricular, pode estar relacionado a alterações na propagação do impulso intraventricular. Objetivo: Avaliar, por meio do mapeamento do potencial de superfície corporal (BSPM), o processo de despolarização ventricular em atletas com intervalos PQ prolongados em repouso e após o exercício. Métodos: O estudo incluiu 7 esquiadores cross-country com intervalo PQ superior a 200 ms (grupo PQ Prolongado) e 7 com intervalo PQ inferior a 200 ms (grupo PQ Normal). O BSPM de 64 derivações unipolares do tronco foi realizado antes (Pré-Ex) e após o teste ergométrico de bicicleta (Pós-Ex). Mapas equipotenciais da superfície corporal foram analisados durante a despolarização ventricular. O nível de significância foi de 5%. Resultados: Comparado com atletas com PQ Normal, o primeiro e o segundo períodos de posição estável dos potenciais cardíacos na superfície do tronco foram mais longos, e a formação da distribuição de potencial "sela" ocorreu mais tarde, no Pré-Ex, nos atletas com PQ Prolongado. No Pós-Ex, o grupo PQ Prolongado apresentou um encurtamento do primeiro e segundo períodos de distribuições de potencial estáveis e uma diminuição no tempo de aparecimento do fenômeno "sela" em relação ao Pré-Ex (para valores próximos aos do Normal -Grupo PQ). Além disso, no Pós-Ex, a primeira inversão das distribuições de potencial e a duração total da despolarização ventricular em atletas com PQ Prolongado diminuíram em comparação com o Pré-Ex e com valores semelhantes em atletas com PQ Normal. Em comparação com atletas com PQ Normal, a segunda inversão foi mais longa no Pré-Ex e Pós-Ex em atletas com PQ Prolongado. Conclusão: Atletas com PQ prolongado apresentaram diferenças significativas nas características temporais do BSPM durante a despolarização ventricular, tanto em repouso quanto após o exercício, em comparação com atletas com PQ normal.


Abstract Background: Prolongation of the PQ interval, generally associated with an atrioventricular conduction delay, may be related to changes in intraventricular impulse spreading. Objective: To assess, using body surface potential mapping (BSPM), the process of ventricular depolarization in athletes with prolonged PQ intervals at rest and after exercise. Methods: The study included 7 cross-country skiers with a PQ interval of more than 200 ms (Prolonged-PQ group) and 7 with a PQ interval of less than 200 ms (Normal-PQ group). The BSPM from 64 unipolar torso leads was performed before (Pre-Ex) and after the bicycle exercise test (Post-Ex). Body surface equipotential maps were analyzed during ventricular depolarization. The significance level was 5%. Results: Compared to Normal-PQ athletes, the first and second periods of the stable position of cardiac potentials on the torso surface were longer, and the formation of the "saddle" potential distribution occurred later, at Pre-Ex, in Prolonged-PQ athletes. At Post-Ex, the Prolonged-PQ group showed a shortening of the first and second periods of stable potential distributions and a decrease in appearance time of the "saddle" phenomenon relative to Pre-Ex (to the values near to those of the Normal-PQ group). Additionally, at Post-Ex, the first inversion of potential distributions and the total duration of ventricular depolarization in Prolonged-PQ athletes decreased compared to Pre-Ex and with similar values in Normal-PQ athletes. Compared to Normal-PQ athletes, the second inversion was longer at Pre-Ex and Post-Ex in Prolonged-PQ athletes. Conclusion: Prolonged-PQ athletes had significant differences in the temporal characteristics of BSPM during ventricular depolarization both at rest and after exercise as compared to Normal-PQ athletes.

2.
Journal of Practical Radiology ; (12): 293-296, 2024.
Artículo en Chino | WPRIM | ID: wpr-1020205

RESUMEN

Objective To investigate the complications of CT-guided percutaneous lung biopsy(CT-PTNB)and its correlation with improper operation.Methods The clinical data of 360 patients who underwent lung tumor needle biopsy were collected.The complications occurred in the process of needle biopsy and their correlation with improper operation were summarized,and the experience was further summarized to increase the success rate of needle biopsy and reduce the occurrence of complications.Results Biopsy tissue was successfully obtained in all 360 patients.There were 84 cases with complications after puncture,including 67 cases with pneumothorax,59 cases with hemorrhage(5 cases with hemoptysis,59 cases with needle tract hemorrhage with pulmonary hemorrhage,6 cases with intrathoracic hemorrhage),9 cases with subcutaneous emphysema of chest wall,and 3 cases with chest wall puncture point pain,and all patients did not undergo surgical treatment.All patients recovered from symptomatic treatment such as bed rest,hemostasis,anti-inflammatory and oxygen inhalation.Only 6 patients with pneumothorax had increased volume of pneumothorax after operation and underwent closed thoracic drainage,and all of them were decannulated successfully.No air embolism and other rare complications occurred.Conclusion The appropriate puncture path should be selected according to the different conditions of the patient.At the same time,the anatomy of the chest wall and lung should be familiar with,and pay attention to all the details of the needle biopsy process to reduce the occurrence of errors.

3.
Journal of Practical Radiology ; (12): 633-636, 2024.
Artículo en Chino | WPRIM | ID: wpr-1020272

RESUMEN

Objective To explore the application value of a special fence in percutaneous transhepatic cholangial drainage(PTCD)under the guidance of C-arm CT.Methods A total of 43 patients who underwent PTCD were randomly divided into observation group and control group.The intervention operation in the observation group was guided by C-arm CT and located by special fence;in the control group,the intervention operation was only performed under digital subtraction angiography(DSA)fluoroscopy.Respectively,the differences in operation time,number of puncture needles and number of complications between the two groups were compared.Results The operation time,puncture times and complications in the observation group were(39.33±12.96)min,(1.67±0.80)times and 3 cases respectively;in the control group were(86.77±22.70)min,(3.41±1.26)times and 13 cases respectively;There were significant differences between the two groups(P<0.05).Conclusion The application of special fence in PTCD under the guidance of C-arm CT can short the operation time,reduce the number of punctures and reduce complications,which has important clinical application value.

4.
Artículo en Chino | WPRIM | ID: wpr-1024941

RESUMEN

Objective To explore the application value of emergency temporal body surface positioning for single drain dual-target thalamic hematoma ventricular drainage in the treatment of thalamic hemorrhage breaking into ventricle with hydrocephalus.Methods A retrospective analysis was conducted on 223 patients with thalamic hemorrhage breaking into the ventricles with hydrocephalus,including a study group of 115 cases who underwent emergency single drain dual-target thalamic hematoma ventricular drainage surgery with temporal body surface positioning,and a control group of 108 cases who underwent emergency ventricular drainage first and then underwent stereotactic thalamic hematoma drainage surgery after the condition stabilized.Compare the differences in postoperative complications and treatment outcomes between two groups of patients,and evaluate the application value of temporal surface positioning for single drain dual-target thalamic hematoma ventricular drainage surgery in the treatment of thalamic hemorrhage breaking into the ventricle with hydrocephalus.Results The postoperative rebleeding rates,hematoma clearance and death were 5.2%,87.5%±7.3%and 13.9%in the study group and 4.7%,90.2%±8.5%and 15.7%in control group,respectively.There was no significant difference between the two groups(P>0.05).The tube time,postoperative intracranial infection,Shunt dependent hydrocephalus,effective treatment and favorable prognosis of and the control group were(75.5±18.4)h,3.5%,19.1%,53.9%and 51.3%in the study group and(130.8±22.9)h,13.9%,35.1%,38.7%and 38.0%,respectively.The difference between the two groups was statistically significant(P<0.05).Conclusion Body surface landmark-guided emergency single drain dual-target thalamic hematoma ventricular drainage surgery for the treatment of thalamic hemorrhage breaking into the ventricle with hydrocephalus is safe and reliable,and can improve the patient's prognosis.

5.
Int. j. morphol ; 41(6): 1679-1686, dic. 2023. ilus, tab
Artículo en Inglés | LILACS | ID: biblio-1528802

RESUMEN

SUMMARY: The liver has over 500 physiological and biochemical roles in our organism so checking of liver size and function is a part of every clinical examination. Aim of our research was to estimate liver size on computed tomography (CT) of the abdomen images and to determinate relations between liver dimensions and anthropometric parameters. The research included 99 patients, 49 men and 50 women, who were referred for CT of abdomen. We measured body height (BH) and body mass (BM), and calculated body mass index (BMI) and body surface area (BSA). Also, on CT images we measured anteroposterior (AP), laterolateral (LL) and two craniocaudal liver diameters (one at the level of midclavicular line - CCmcl, and the other was maximal - CCmax). Liver volume (LV) was calculated with formula. Our results showed that AP diameter positively correlated with BSA (r=0.30) in women. LL diameter positively correlated with BH (r=0.43), and BSA (0.31) in men. CCmcl diameter positively correlated with BH (r=0.33), BM (r=0.31), and BSA (r=0.34) in men, while in women it correlated only with BH (r=0.38). CCmax diameter positively correlated with BH (r=0.33) and BSA (r=0.33) in men. LV positively correlated with BH and BSA in both men (r=0.36, r=0.33, respectively) and women (r=0.42, r=0.31, respectively), and in men also with BM (r=0.34). LL, CCmcl, CCmax, and LV negatively correlated with aging in both sexes After the age of 60, there was a decrease in size of LL, CC diameters, as well as in LV. We concluded that liver dimensions decrease with aging, regardless of sex at the expanse of LL and CC diameters which are related to the size of body parameters, so that for a precise evaluation of liver size all three diameters should be measured, LV as well as BH, BM, and BSA.


El hígado desempeña más de 500 funciones fisiológicas y bioquímicas en nuestro organismo, por lo que comprobar el tamaño y la función de este órgano es parte de cada examen clínico. El objetivo de nuestra investigación fue estimar el tamaño del hígado mediante tomografía computarizada (TC) de imágenes del abdomen y determinar las relaciones entre las dimensiones del hígado y los parámetros antropométricos. La investigación incluyó a 99 pacientes, 49 hombres y 50 mujeres, que fueron remitidos para TC de abdomen. Medimos la altura corporal (BH) y la masa corporal (BM), y calculamos el índice de masa corporal (IMC) y el área de superficie corporal (BSA). Además, en las imágenes de TC medimos los diámetros hepáticos anteroposterior (AP), laterolateral (LL) y dos craneocaudales (uno a nivel de la línea medioclavicular - CCmcl, y el diámetro máximo - CCmax). El volumen del hígado (VI) se calculó con una fórmula. Nuestros resultados mostraron que el diámetro AP se correlacionó positivamente con BSA (r = 0,30) en mujeres. El diámetro de LL se correlacionó positivamente con BH (r=0,43) y BSA (0,31) en hombres. El diámetro CCmcl se correlacionó positivamente con BH (r=0,33), BM (r=0,31) y BSA (r=0,34) en hombres, mientras que en mujeres se correlacionó solo con BH (r=0,38). El diámetro CCmax se correlacionó positivamente con BH (r=0,33) y BSA (r=0,33) en hombres. El VI se correlacionó positivamente con BH y BSA tanto en hombres (r=0,36, r=0,33, respectivamente) como en mujeres (r=0,42, r=0,31, respectivamente), y en hombres también con BM (r=0,34). LL, CCmcl, CCmax y LV se correlacionaron negativamente con el envejecimiento en ambos sexos. Después de los 60 años, hubo una disminución en el tamaño de los diámetros LL, CC y LV. Concluimos que las dimensiones del hígado disminuyen con la edad, independientemente del sexo, en la extensión de los diámetros LL y CC que están relacionados con el tamaño de los parámetros corporales, por lo que para una evaluación precisa del tamaño del hígado se debe medir LV como BH, BM y BSA.


Asunto(s)
Humanos , Masculino , Femenino , Persona de Mediana Edad , Anciano , Antropometría , Hígado/diagnóstico por imagen , Peso Corporal , Tomografía Computarizada por Rayos X , Índice de Masa Corporal , Factores Sexuales , Factores de Edad , Hígado/anatomía & histología
6.
Rev. bras. cir. cardiovasc ; 38(1): 37-42, Jan.-Feb. 2023. tab, graf
Artículo en Inglés | LILACS-Express | LILACS | ID: biblio-1423067

RESUMEN

ABSTRACT Introduction: Bleeding after transcatheter aortic valve replacement (TAVR) is associated with increased mortality. The predictive value of the HAS-BLED score in TAVR patients is still to be evaluated. We assessed the value of the HAS-BLED score to predict in-hospital bleeding and mortality after TAVR and the impact of diferent renal impairment definitions on the predictive value of the score system. Methods: We retrospectively included 574 patients who underwent TAVR at a single center. Study outcomes were 30-day mortality and the composite endpoint of major and life-threatening bleeding as defined by The Valve Academic Research Consortium-2. The predictive value of the HAS-BLED score was calculated and compared to a modified model. The performance of the score was compared using two definitions of renal impairment. Model discrimination was tested using C-statistic and the Net Reclassification Index. Results: Bleeding occurred in 78 patients (13.59%). HAS-BLED category 3 was a significant predictor of bleeding (OR: 1.99 ]1.18- 3.37], C-index: 0.56, P=0.01). C-index increased to 0.64 after adding body surface area and extracardiac arteriopathy to the model. The Net Reclassification Index showed an increase in the predic tive value of the model by 11.4% (P=0.002). The C-index increased to 0.61 using renal impairment definition based on creatinine clearance. Operative mortality was significantly associated with the HAS-BLED score (OR: 7.54 [95% CI: 2.73- 20.82], C-index: 0.73, P<0.001). Conclusion: The HAS-BLED score could be a good predictor of in-hospital mortality after TAVR. Its predictive value for bleeding was poor but improved by adding procedure-specific factors and using creatinine clearance to define renal impairment.

7.
Artículo en Chino | WPRIM | ID: wpr-980742

RESUMEN

OBJECTIVE@#To detect the body surface temperature of the relevant back-shu points in patients with chronic persistent asthma by infrared thermal imaging technology, and observe the specific changes of the body surface temperature of the relevant back-shu points under the condition of lung disease.@*METHODS@#Forty-five patients with chronic persistent asthma (observation group) and 45 healthy subjects (control group) were selected. The body surface temperature of bilateral Feishu (BL 13), Geshu (BL 17), Pishu (BL 20) and Shenshu (BL 23) were measured by BK-MT02A medical infrared thermography.@*RESULTS@#The body surface temperature of bilateral Feishu (BL 13), Geshu (BL 17), Pishu (BL 20) and Shenshu (BL 23) in the observation group was higher than that in the control group (P<0.01, P<0.05). The body surface temperature of bilateral Feishu (BL 13) and Geshu (BL 17) was higher than that of ipsilateral Pishu (BL 20) and Shenshu (BL 23) in the two groups (P<0.01, P<0.05). There was no statistically significant difference in body surface temperature between ipsilateral Feishu (BL 13) and Geshu (BL 17), between ipsilateral Pishu (BL 20) and Shenshu (BL 23) (P>0.05).@*CONCLUSION@#The pathological increase of body surface temperature of Feishu (BL 13), Geshu (BL 17), Pishu (BL 20) and Shenshu (BL 23) in patients with chronic persistent asthma indicates that above acupoints have specificity in reflecting lung diseases. The Feishu (BL 13) and Geshu (BL 17), which have significantly increased body surface temperature, not only provide objective basis for the pathological pathogenesis of "deficiency in origin and excess in symptom" in patients with chronic persistent asthma, but also reflect the different expressions of different acupoints on the same meridian for the lung diseases.


Asunto(s)
Humanos , Temperatura , Asma/diagnóstico por imagen , Meridianos , Puntos de Acupuntura , Terapia por Acupuntura/métodos
8.
Artículo en Chino | WPRIM | ID: wpr-970552

RESUMEN

This study aimed to explore the infrared manifestation and role of brown adipose tissue(BAT) in phlegm-dampness me-tabolic syndrome(MS), and to provide objective basis for clinical diagnosis and treatment of phlegm-dampness MS. Subjects were selected from the department of endocrinology and ward in the South District of Guang'anmen Hospital, China Academy of Chinese Medical Sciences from August 2021 to April 2022, including 20 in healthy control group, 40 in non phlegm-dampness MS group and 40 in phlegm-dampness MS group. General information, height and weight of the subjects were collected and body mass index(BMI) was calculated. Waist circumference(WC), systolic blood pressure(SBP) and diastolic blood pressure(DBP) was measured. Triglyceride(TG), high density lipoprotein cholesterol(HDL-C), fasting blood glucose(FBG), fasting insulin(FINS), leptin(LP), adiponectin(ADP) and fibroblast growth factor-21(FGF-21) were detected. The infrared thermal image of the supraclavicular region(SCR) of the subjects before and after cold stimulation test was collected by infrared thermal imager and the changes of infrared thermal image in the three groups were observed. In addition, the differences in the average body surface temperature of SCR among the three groups were compared, and the changes of BAT in SCR were analyzed. The results showed compared with the conditions in healthy control group, the levels of WC, SBP, DBP, TG and FPG in MS groups were increased(P<0.01), and the HDL-C level was decreased(P<0.01). Compared with non phlegm-dampness MS group, phlegm-dampness MS group had higher conversion score of phlegm dampness physique(P<0.01). According to the infrared heat map, there was no difference in the average body surface temperature of SCR among the three groups before cold stimulation. while after cold stimulation, the average body surface temperature of SCR in MS groups was lower than that in healthy control group(P<0.05). After cold stimulation, the maximum temperature of SCR and its arrival time in the three groups were as follows: healthy control group(3 min)>non phlegm-dampness MS group(4 min)>phlegm-dampness MS group(5 min). The thermal deviation of SCR was increased and the average body surface temperature of left and right sides were higher(P<0.01) in healthy control group and non phlegm-dampness MS group, while the thermal deviation of SCR did not change significantly in the phlegm-dampness MS group. Compared with that in healthy control group, the elevated temperature between left and right sides was lower(P<0.01, P<0.05), and compared with that in non phlegm-dampness MS group, the elevated temperature of left side was lower(P<0.05). The changes of the average body surface temperature of SCR in the three groups were in the order of healthy control group>non phlegm-dampness MS group>phlegm-dampness MS group. Compared with the conditions in healthy control group and non phlegm-dampness MS group, FINS, BMI and FGF-21 levels were increased(P<0.01,P<0.05), while ADP level was decreased(P<0.01, P<0.05) in phlegm-dampness MS group. Moreover, the LP level in phlegm-dampness MS group was higher than that in non phlegm-dampness MS group(P<0.01). It was observed in clinical trials that after cold stimulation, the average body surface temperature of SCR in MS patients was lower than that of the healthy people; the thermal deviation of SCR did not change significantly in the phlegm-dampness MS patients, and the difference in their elevated temperature was lower than that in the other two groups. These characteristics provided objective basis for clinical diagnosis and treatment of phlegm-dampness MS. With abnormal BAT related indicators, it was inferred that the content or activity of BAT in SCR of phlegm-dampness MS patients were reduced. There was a high correlation between BAT and phlegm-dampness MS, and thus BAT might become an important potential target for the intervention in phlegm-dampness MS.


Asunto(s)
Humanos , Síndrome Metabólico , Tejido Adiposo Pardo , Moco , Adiponectina , Índice de Masa Corporal
9.
Artículo en Chino | WPRIM | ID: wpr-970685

RESUMEN

For the detection and identification of abnormal nodular tissues on the body surface, a microwave sensor structure loaded with a spiral resonator is proposed in this paper, a sensor simulation model is established using HFSS software, the structural parameters are optimized, and the actual sensor is fabricated. The S21 parameters of the tissue were obtained when nodules appeared by simulation, and the characteristic relationship between the difference of S21 parameters with position was analyzed and tested experimentally. The results showed that when nodules were present in normal tissues, the curve of S21 parameter difference with position change had obvious inverted bimodal characteristics, and the extreme value of S21 parameter difference appeared when the sensor was directly above the nodules, which was easy to identify the position of nodules. It provides an objective detection tool for the identification of abnormal nodular tissues on the body surface.


Asunto(s)
Microondas , Reconocimiento en Psicología , Simulación por Computador , Programas Informáticos
10.
Artículo en Chino | WPRIM | ID: wpr-1019430

RESUMEN

Objective:To investigate the feasibility of multipoint core needle biopsy (CNB) at mid-stage to predict the treatment effect of neoadjuvant systemic therapy for breast cancer.Methods:A total of 67 breast cancer cases with indications of neoadjuvant systemic therapy were selected from Mar. 2021 to Nov. 2022.In the fourth cycle of neoadjuvant systemic therapy, core needle biopsy was performed at 3, 6, 9, 12 points of tumor bed and residual tumor foci of breast respectively.The results of CNB were compared with the results of routine pathology of surgery after the completion of neoadjuvant therapy. Matched biopsy and surgical specimens were compared to assess pCR. The accuracy and false negative rate (FNR) of interim pathological assessment were analyzed. The coincidence probability of interim biopsy pathology and pathology of standard surgical excision was verified.Results:The median age of enrolled patients was 49.2 years (21-69 years) .Median maximum tumor diameter before neoadjuvant systemic therapy and residual tumor diameter after neoadjuvant therapy were 40.4 mm (range 21-93mm) and 19.6 mm (range 0-41mm) respectively. A total of 28 patients achieved pCR, and the PCR rates of hormone receptor-positive and HER2-nagative,triple-negative,hormone receptor negative and HER2-positive and hormone receptor-positive and HER2-positive disease were 4/24 (16.7%) ,6/14 (42.9%) ,11/18 (61.1%) ,7/11 (63.6%), respectively. Two cases had no preoperative imaging abnormalities. The results of core needle biopsy pathology of residual tumor lesions in 55 patients were consistent with those of routine post-operation pathology.The results of core needle biopsy pathology of tumor bed of 56 patients was consistent with the routine pathology of surgery. The false negative rate of interim multipoint biopsy pathology of residual tumor foci was 17.9% (12/67). The false negative rate of tumor bed with core needle biopsy was 5.9% (4/67) .Conclusions:CNB guided under ultrasound is feasible in predicting tumor retreat situation in the tumor bed area and residual tumor foci at mid-stage of neoadjuvant therapy. Increasing the number of core needles and improving biopsy techniques may improve the accuracy of pathological evaluation of interim multipoint biopsy.

11.
Artículo en Chino | WPRIM | ID: wpr-1028786

RESUMEN

Objective To investigate the clinical value of body surface location by mammography in open biopsy of non-palpable breast calcification.Methods Clinical data of 63 patients with 65 non-palpable but mammography indication of calcification from September 2018 to August 2023 were collected.Open biopsy was performed by using a self-created method of body surface location by mammography.Surgical complete excision rate and pathological results of suspected calcifications were analyzed.Results All the 65 breast calcification lesions were successfully located and completely resected,among which 64 lesions(98.5%)were removed completely by one time and 1 lesion was removed by the second resection.Intraoperative specimen mammography showed the surgical margin was>2 mm and<1 cm.Pathological diagnosis showed47 benign lesions(16 lesions of hyperplasia,14 lesions of fibroadenoma,6 lesions of sclerosing adenosis,3 lesions of intraductal papilloma,1 lesion of breast mucous cyst,5 lesions of atypical hyperplasia,and 2 lesions of lobular carcinoma in situ)and 18 malignant lesions(15 lesions of ductal carcinoma in situ,2 lesions of ductal carcinoma in situ with microinvasion,and 1 lesion of invasive carcinoma).Conclusions For the biopsy of non-palpable breast calcification,body surface location by mammography can be used for accurately locating.It is simple and easy to learn,with low cost and high safety,which is of great significance for the detection of early breast cancer.

12.
Artículo en Chino | WPRIM | ID: wpr-1027326

RESUMEN

Objective:To explore the influence of the contours of different parts of the human body on the setup errors of Catalyst HD optical surface imaging (OSI) system-guided radiotherapy.Methods:Using the 3D printing technology, arc- and oval arc-shaped phantoms with base angles of 5°-45° (step length: 5°) were designed to simulate the contours of different body parts of patients. A Catalyst HD system was employed for monitoring, during which the gains and integration time of the system were adjusted. The treatment couches were manually moved (range: -5 mm to 5 mm, with a step length of 2 mm). The ratios of transverse to longitudinal dimensions of all phantoms were recorded. The recorded items also included couch value errors in the anterior-posterior (AP), inferior-superior (SI), and left-right (LR) directions for transversely and longitudinally placed phantoms, as well as the setup errors monitored using the Catalyst HD system. Then, this study presented an analysis of the correlation between phantoms for different body contours and the gains and integration time of the Catalyst HD system. The purpose was to compare the setup errors under the two different placement conditions of phantoms and to analyze the correlation between the monitored values of the Catalyst HD system and couch values.Results:There was a significant linear negative correlation between the gain and the logarithm of integration time required for monitoring using the Catalyst HD system, with a slope of -0.001. There was a certain functional relationship between the intercept and the ratio of the transverse to longitudinal dimensions of the phantoms. Under the same gain, the integration time decreased with an increase in the base angles of phantoms. The Catalyst HD system showed different monitoring accuracy under different placement conditions of the phantoms ( Z = -8.59 to -0.02, P < 0.05), with the monitoring accuracy in the LR and AP directions higher in the transverse position. The correlation between the monitored values of the Catalyst HD system and the actual couch values increased in the LR and SI directions with an increase in the base angle of the phantoms, showing a strong correlation in the case of base angles of ≥ 25°. Furthermore, the correlation was always significant in the AP direction ( R > 0.9). Conclusions:When the best surface images are obtained using the Catalyst HD system, the gains and integration time of the system are correlated with body surface contours. The Catalyst HD system shows high monitoring accuracy in the AP direction. This system shows high accuracy in all directions when the ratios of transverse to longitudinal dimensions are ≤ 2 or the base angles ≥ 25°.

13.
Rev. bras. cir. cardiovasc ; 38(3): 389-397, 2023. tab, graf
Artículo en Inglés | LILACS-Express | LILACS | ID: biblio-1441202

RESUMEN

ABSTRACT Introduction: Postoperative thrombocytopenia is common in cardiac surgery with cardiopulmonary bypass, and its risk factors are unclear. Methods: This retrospective study enrolled 3,175 adult patients undergoing valve surgeries with cardiopulmonary bypass from January 1, 2017 to December 30, 2018 in our institute. Postoperative thrombocytopenia was defined as the first postoperative platelet count below the 10th quantile in all the enrolled patients. Outcomes between patients with and without postoperative thrombocytopenia were compared. The primary outcome was in-hospital mortality. Risk factors of postoperative thrombocytopenia were assessed by logistic regression analysis. Results: The 10th quantile of all enrolled patients (75×109/L) was defined as the threshold for postoperative thrombocytopenia. In-hospital mortality was comparable between thrombocytopenia and non-thrombocytopenia groups (0.9% vs. 0.6%, P=0.434). Patients in the thrombocytopenia group had higher rate of postoperative blood transfusion (5.9% vs. 3.2%, P=0.014), more chest drainage volume (735 [550-1080] vs. 560 [430-730] ml, P<0.001), and higher incidence of acute kidney injury (12.3% vs. 4.2%, P<0.001). Age > 60 years (odds ratio [OR] 2.25, 95% confidence interval [CI] 1.345-3.765, P=0.002], preoperative thrombocytopenia (OR 18.671, 95% CI 13.649-25.542, P<0.001), and cardiopulmonary bypass time (OR 1.088, 95% CI 1.059-1.117, P<0.001) were positively independently associated with postoperative thrombocytopenia. Body surface area (BSA) (OR 0.247, 95% CI 0.114-0.538, P<0.001) and isolated mitral valve surgery (OR 0.475, 95% CI 0.294-0.77) were negatively independently associated with postoperative thrombocytopenia. Conclusion: Positive predictors for thrombocytopenia after valve surgery included age > 60 years, small BSA, preoperative thrombocytopenia, and cardiopulmonary bypass time. BSA and isolated mitral valve surgery were negative predictors.

15.
Arq. bras. cardiol ; 119(5): 766-775, nov. 2022. tab, graf
Artículo en Portugués | LILACS-Express | LILACS | ID: biblio-1533698

RESUMEN

Resumo Fundamento O exercício físico exaustivo pode causar alterações significantes nas propriedades elétricas do miocárdio. Objetivo Avaliar, através do mapeamento potencial de superfície corporal, a atividade elétrica do coração de ratos durante a despolarização ventricular após exercício exaustivo agudo. Métodos Ratos machos com doze semanas de idade foram submetidos a exercício agudo em esteira a 36 m/min até a exaustão. Eletrocardiogramas unipolares (ECGs) da superfície do tronco foram registrados em ratos anestesiados com zoletil três a cinco dias antes (Pré-Ex), 5 e 10 minutos após exercício exaustivo (Pós-Ex 5 e Pós-Ex 10, respectivamente) simultaneamente com ECGs nas derivações dos membros. Os mapas potenciais de superfície corporal instantâneos (BSPMs, body surface potential maps ) foram analisados durante a despolarização ventricular. Os valores de p <0,05 foram considerados estatisticamente significantes. Resultados Comparado com o Pré-Ex, uma conclusão precoce da segunda inversão de distribuições de potencial, uma conclusão precoce da despolarização ventricular, bem como uma diminuição na duração da fase média e a duração total da despolarização ventricular nos BSPMs foram reveladas no Pós-Ex5. Além disso, em comparação com o Pré-Ex, um aumento na amplitude do extremo negativo do BSPM no pico da onda R no ECG na derivação II (pico RII) e uma diminuição na amplitude do extremo negativo do BSPM a 3 e 4 ms após o pico RII foram demonstrados no Pós-Ex 5. No Pós-Ex 10, os parâmetros dos BSPMs não diferiram daqueles do Pré-Ex. Conclusão Em ratos, o exercício exaustivo agudo causa alterações reversíveis nas características temporais e de amplitude dos BSPMs durante a despolarização ventricular, provavelmente relacionadas a alterações na excitação da massa principal do miocárdio ventricular.


Abstract Background Exhaustive physical exercise can cause substantial changes in the electrical properties of the myocardium. Objective To evaluate, using body surface potential mapping, the electrical activity of the heart in rats during ventricular depolarization after acute exhaustive exercise. Methods Twelve-week-old male rats were submitted to acute treadmill exercise at 36 m/min until exhaustion. Unipolar electrocardiograms (ECGs) from the torso surface were recorded in zoletil-anesthetized rats three to five days before (Pre-Ex), 5 and 10 minutes after exhaustive exercise (Post-Ex 5 and Post-Ex 10, respectively) simultaneously with ECGs in limb leads. The instantaneous body surface potential maps (BSPMs) were analyzed during ventricular depolarization. P values <0.05 were considered statistically significant. Results Compared with Pre-Ex, an early completion of the second inversion of potential distributions, an early completion of ventricular depolarization, as well as a decrease in the duration of the middle phase and the total duration of ventricular depolarization on BSPMs were revealed at Post-Ex 5. Also, compared with Pre-Ex, an increase in the amplitude of negative BSPM extremum at the R-wave peak on the ECG in lead II (RII-peak) and a decrease in the amplitude of negative BSPM extremum at 3 and 4 ms after RII-peak were showed at Post-Ex 5. At Post-Ex 10, parameters of BSPMs did not differ from those at Pre-Ex. Conclusion In rats, acute exhaustive exercise causes reversible changes in the temporal and amplitude characteristics of BSPMs during ventricular depolarization, most likely related to alterations in the excitation of the main mass of the ventricular myocardium.

16.
Ethiopian Journal of Health Sciences ; 32(5): 885-894, 5 September 2022. Tables
Artículo en Inglés | AIM | ID: biblio-1398203

RESUMEN

Vitamin D deficiency is common among women during pregnancy. This study aims to determine the prevalence of vitamin D deficiency and their shared modifiable environmental factors among pregnant women in Indonesia and Malaysia. METHODS: Blood samples of 844 third-trimester pregnant women (Indonesians: 311; Malaysians: 533) were collected to determine their serum 25(OH) D levels. Information on sun exposure and sun protection behaviours were obtained through face-to-face interviews. Dietary vitamin D intake was assessed by using a semiquantitative food frequency questionnaire. RESULTS: The prevalence of vitamin D deficiency (<30 nmol/L) among Indonesian and Malaysian pregnant women were 42.4% and 72.0%, respectively. Percentage of exposed body surface area was inversely associated with vitamin D deficiency among Indonesian pregnant women (OR = 0.21, 95% CI = 0.09-0.48). Among Malaysian pregnant women, higher intakes of dietary vitamin D were associated with lower risk of vitamin D deficiency (OR = 0.48, 95% CI = 0.29-0.81). Analysis of the combined cohorts revealed a lower risk of vitamin D deficiency among pregnant women who had a daily intake of at least 15 mcg vitamin D (OR = 0.58, 95% CI = 0.38-0.88) and exposure of more than 27% body surface area to the sunlight (OR = 0.30, 95% CI = 0.16-0.60). CONCLUSION: Despite abundant sunshine, vitamin D deficiency is prevalent among pregnant women in tropical countries. The present study suggests that nutrition education on vitamin D intake and sun exposure during pregnancy is necessary for primary prevention of vitamin D deficiency in pregnant women living in the tropical countries


Asunto(s)
Deficiencia de Vitamina D , Superficie Corporal , Prevalencia , Mujeres Embarazadas , Nutrición Prenatal , Malasia
17.
Dent. press endod ; 11(3): 40-45, Sept-Dec.2021. Tab, Ilus
Artículo en Inglés | LILACS | ID: biblio-1379003

RESUMEN

Objetivo: O objetivo desse artigo foi avaliar a precisão das porções milimetrada e calibradora das réguas endodônticas, e avaliar a regularidade da superfície dos orifícios calibradores. Métodos: A porção milimetrada das réguas Angelus, Maillefer, Maquira, Microdont e Prisma foi avaliada com paquímetro eletrônico digital. Os orifícios calibradores da Maillefer, Prisma e Angelus foram medidos com um projetor de perfil. A regularidade da superfície dos orifícios calibradores foi classificada em S1 ­ sem irregularidades ou S2 ­ com regularidades. A análise de precisão das porções milimetrada e calibradora foi realizada com o teste t (p=0,05); e as frequências dos tipos de superfície, com o teste do qui-quadrado (p<0,05). Resultados: A Maillefer foi a única régua endodôntica com precisão em todos os comprimentos e orifícios. A Prisma apresentou estatisticamente mais orifícios do tipo S2, quando comparada com outras réguas endodônticas avaliadas (p<0,05). Não houve diferença estatisticamente significativa entre Angelus e Maillefer (p>0,05). Conclusão: A Maillefer apresentou precisão nas porções milimetrada e calibradora. As réguas endodônticas da Angelus não foram precisas em nenhum comprimento da parte milimetrada e não foram precisas na maioria dos orifícios calibradores. A régua endodôntica Prisma mostrou significativamente mais orifícios calibradores com irregularidades na superfície do que Angelus e Maillefer. Destaca-se a necessidade de controle de qualidade e padrões específicos para fabricação das réguas endodônticas (AU).


Objective: The aim was to evaluate the accuracy of the millimeter and calibration portion and evaluate the regularity of the calibrator orifice surfaces of the endodontic rulers. Methods: The millimeter portion of the Angelus, Maillefer, Maquira, Microdont and Prisma rulers was evaluated with an electronic digital caliper. The calibration holes of the Maillefer, Prisma and Angelus were measured with Profile Projector. The surface regularity of calibration holes was evaluated and classified in S1- without irregularities and S2- with irregularities. The accuracy analysis of the millimeter and calibration was performed with T-Test (p=0.05) and the frequencies of the surface types with Chi-square (p<0.05). Results: The Maillefer was the only rulers with accuracy in all lengths and holes. Prisma presented statistically more S2 type holes when compared with other endodontic rulers evaluated (p <0.05). There was no statistically significant difference between Angelus and Maillefer (p> 0.05). Conclusion: The Maillefer presented accuracy in the millimeter and calibration portion. Angelus endodontic rulers were not accurate at any rated length of the millimeter portion and it was not accurate in most calibration holes evaluated. Prisma endodontic ruler showed significantly more calibration holes with irregular surfaces than Angelus and Maillefer. We emphasize the need for quality control and specific standards for endodontic rulers manufacturing (AU).


Asunto(s)
Control de Calidad , Calibración , Electrónica , Estándares de Referencia , Métodos
18.
J. bras. nefrol ; 43(1): 52-60, Jan.-Mar. 2021. tab, graf
Artículo en Inglés, Portugués | LILACS | ID: biblio-1154650

RESUMEN

ABSTRACT Background: Kt/V OnLine (Kt/VOL) avoids inaccuracies associated with the estimation of urea volume distribution (V). The study aimed to compare Kt/VOL, Kt/V Daugirdas II, and Kt/BSA according to sex and age. Methods: Urea volume distribution and body surface area were obtained by Watson and Haycock formulas in 47 patients. V/BSA was considered as a conversion factor from Kt/V to Kt/BSA. Dry weight was determined before the study. Kt/VOL was obtained on DIALOG machines. Results: Pearson correlation between Kt/VOL vs Kt/VII and Kt/VOL vs Kt/BSA was significant for males (r = 0.446, P = 0.012 and r = -0.476 P = 0.007) and individuals < 65 years (0.457, P = 0.019 and -0.549 P = 0.004), but not for females and individuals ≥ 65 years. V/BSA between individuals < 65 and individuals ≥ 65 years were 18.28 ± 0.15 and 18.18 ± 0.16 P = 0.000). No agreement between Kt/VII vs Kt/BSA. Men and individuals > 65 years received a larger dialysis dose than, respectively, females and individuals < 65 years, in the comparison between Kt/VOL versus Kt/VII. V/BSA ratios among men and women were respectively 18.29 ± 0.13 and 18.12 ± 0.15 P = 0.000. Conclusions: Kt/VOL allows recognition of real-time dose regardless of sex and age.


RESUMO Introdução: O Kt/V OnLine (Kt/VOL) evita imprecisões associadas à estimativa da distribuição do volume de uréia (V). O estudo teve como objetivo comparar Kt/VOL, Kt/V Daugirdas II e Kt/BSA de acordo com sexo e idade. Métodos: A distribuição do volume de uréia e área de superfície corporal foram obtidas pelas fórmulas de Watson e Haycock em 47 pacientes. V/BSA foi considerado um fator de conversão de Kt/V para Kt/BSA. O peso seco foi determinado antes do estudo. Kt/VOL foi obtido através de máquinas DIALOG. Resultados: A correlação de Pearson entre Kt/VOL vs Kt/VII e Kt/VOL vs Kt/BSA foi significativa para os homens (r = 0,446, P = 0,012 e r = -0,476 P = 0,007) e indivíduos < 65 anos (0,457, P = 0,019 e -0,549 P = 0,004), mas não para mulheres e indivíduos ≥ 65 anos. A V/BSA entre indivíduos <65 e indivíduos ≥ 65 anos foi 18,28 ± 0,15 e 18,18 ± 0,16 P = 0,000). Sem concordância entre Kt/VII vs Kt/BSA. Homens e indivíduos > 65 anos receberam maior dose de diálise do que, mulheres e indivíduos <65 anos, respectivamente, na comparação entre Kt/VOL versus Kt/VII. As razões V/BSA entre homens e mulheres foram, respectivamente, 18,29 ± 0,13 e 18,12 ± 0,15 P = 0,000. Conclusões: Kt/VOL permite o reconhecimento da dose em tempo real, independentemente do sexo e idade.


Asunto(s)
Humanos , Masculino , Femenino , Soluciones para Diálisis , Diálisis Renal , Urea
19.
Rev. bras. cir. cardiovasc ; 36(1): 10-17, Jan.-Feb. 2021. tab, graf
Artículo en Inglés | LILACS | ID: biblio-1155793

RESUMEN

Abstract Introduction: There are scarce data comparing different mechanical valves in the aortic position. The objective of this study was to compare the early hemodynamic changes after aortic valve replacement between ATS, Bicarbon, and On-X mechanical valves. Methods: We included 99 patients who underwent aortic valve replacement with mechanical valves between 2017 and 2019. Three types of mechanical valves were used, On-X valve (n=45), ATS AP360 (n=32), and Bicarbon (n=22). The mean prosthetic valve gradient was measured postoperatively and after six months. Results: Preoperative data were comparable between groups, and there were no differences in preoperative echocardiographic data. Pre-discharge echocardiography showed no difference between groups in the ejection fraction (P=0.748), end-systolic (P=0.764) and end-diastolic (P=0.723) diameters, left ventricular mass index (P=0.348), aortic prosthetic mean pressure gradient (P=0.454), and indexed aortic prosthetic orifice area (P=0.576). There was no difference in the postoperative aortic prosthetic mean pressure gradient between groups when stratified by valve size. The changes in the aortic prosthetic mean pressure gradient of the intraoperative period, at pre-discharge, and at six months were comparable between the three prostheses (P=0.08). Multivariable regression analysis revealed that female gender (beta coefficient -0.242, P=0.027), body surface area (beta coefficient 0.334, P<0.001), and aortic prosthetic size (beta coefficient -0.547, P<0.001), but not the prosthesis type, were independent predictors of postoperative aortic prosthetic mean pressure gradient. Conclusion: The three bileaflet mechanical aortic prostheses (On-X, Bicarbon, and ATS) provide satisfactory early hemodynamics, which are comparable between the three valve types and among different valve sizes.


Asunto(s)
Humanos , Masculino , Femenino , Estenosis de la Válvula Aórtica/cirugía , Prótesis Valvulares Cardíacas , Válvula Aórtica/cirugía , Válvula Aórtica/diagnóstico por imagen , Diseño de Prótesis , Ecocardiografía , Ecocardiografía Doppler , Hemodinámica
20.
Artículo en Chino | WPRIM | ID: wpr-1015068

RESUMEN

AIM: To study the effects of individual differences (gender, age, body surface area, and body weight) on the pharmacokinetics of capecitabine in cancer patients in hoping of providing evidence for the rational use of capecitabine in clinic. METHODS: A total of 76 patients with various solid tumors were given a single dose of 0.6 g (0.15 g, 4 tablets) capecitabine in postprandial and blood samples were collected at multiple time points. The plasma concentration of capecitabine and its active metablolite, 5-fluorouracil (5-FU) were analyzed by HPLC-MS/MS and the pharmacokinetic parameters of the drugs were calculated by Phoenix WinNonlin7.0 software. RESULTS: Following oral administration, the C

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA