Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
1.
Braz. dent. j ; 30(1): 47-51, Jan.-Feb. 2019. tab, graf
Artículo en Inglés | LILACS | ID: biblio-989429

RESUMEN

Abstract The purpose of thisin vitrostudy was to evaluate the influence of a new proposal of implant design and surgical protocol on primary stability in different bone densities. Four groups were tested (n=9): G1 - tapered, cone morse, Ø 4.3 mm x 10 mm in length (Alvim CM); G2 - experimental tapered; G3 - cylindrical, cone morse, Ø 4.0 mm x 11 mm in length (Titamax CM) and G4 - experimental cylindrical. The experimental implants were obtained from a design change in the respective commercial models. The insertion was performed in polyurethane (PU) blocks 0.24 g/cm3(20 pcf) and 0.64 g/cm3(40 pcf), according to different surgical protocols. The primary stability was measured by means of insertion torque (IT) and pullout test. Data were analyzed by ANOVA, Tukey's test (α=0.05) and Pearson's correlation. For IT and pullout, conventional and experimental implants showed no difference between them when inserted in the 20 pcf PU (p>0.05). In the 40 pcf PU, the modified implants exhibited greater IT (p<0.05) and lower pullout (p<0.05) compared to the respective conventional models. The implant design tested associated with the surgical protocol, positively influenced primary stability in higher density bones.


Resumo O objetivo deste estudo in vitro foi avaliar a influência de uma nova proposta de design de implante e protocolo cirúrgico na estabilidade primária em diferentes densidades ósseas. Foram testados quatro grupos (n=9): G1 - cônico, cone morse, Ø 4,3 mm x 10 mm de comprimento (Alvim CM); G2 - experimental cônico; G3 - cilíndrico, cone morse, Ø 4,0 mm x 11 mm de comprimento (Titamax CM) e G4 - experimental cilíndrico. Os implantes experimentais foram obtidos a partir de uma mudança no design dos respectivos modelos comerciais. A inserção foi realizada em blocos de poliuretano (PU) 0,24 g/cm3 (20 pcf) e 0,64 g/cm3 (40 pcf), de acordo com diferentes protocolos cirúrgicos. A estabilidade primária foi aferida por meio do torque de inserção (TI) e ensaio de arrancamento. Os dados foram analisados por ANOVA, teste de Tukey (α=0,05) e correlação de Pearson. Para TI e arrancamento, os implantes convencionais e experimentais não mostraram diferença entre si quando inseridos na PU de 20 pcf (p>0,05). Na PU de 40 pcf, os implantes modificados exibiram maior TI (p <0,05) e menor arrancamento (p <0,05) em relação aos respectivos modelos convencionais. O design do implante testado associado ao protocolo cirúrgico, influenciou positivamente a estabilidade primária em ossos de maior densidade.


Asunto(s)
Humanos , Diseño de Prótesis , Procedimientos Quirúrgicos Operativos/métodos , Implantes Dentales , Poliuretanos
2.
Korean Journal of Community Nutrition ; : 327-335, 2002.
Artículo en Coreano | WPRIM | ID: wpr-58222

RESUMEN

This study was performed to investigate the relationships among bone mineral densities (BMD), anthropometric data and lifestyle factors in the elderly. Subjects included 138 elderly (male: 38, female: 100) aged over 65 years, who were home-dwelling in a low-income area of Puchon City. The BMDs of the lumbar spines (LS), femoral necks (FN), Ward's triangles (WT) and trochanters (TC) were measured by dual energy X-ray absorptiometry. The females showed significantly lower BMDs in four sites (p < 0.0001). The elderly aged over 75 revealed significantly more decreased femoral BMDs than the elderly aged 65 to 74. Female with BMIs of 20 to 25, showed significantly higher BMDs in LS, FN and trochanter than those with BMIs of less than 20. However, males displayed significantly higher BMDs in only LS, with increasing BMIs. THe BMDs of LS correlated with weights (r = 0.543, p < 0.001), heights (r = 0.477, p < 0.001), upper arm circumferences (r = 0.368, p < 0.01), waist circumferences (r = 0.367, p < 0.001), subscapular skinfold thicknesses (r = 0.363, p < 0.001) and hip circumferences (r = 0.231, p < 0.01). Non-smokers and non-drinkers showed significantly higher BMDs in trochanters only in the case of the males. Female milk-drinkers showed significantly elevated LS BMDs. Eighteen percent of the males were assessed as having osteoporosis, as compared to fifty percent of the females. Ninety-three percent of the females and 81.6% of the males responded that they often or always had "difficulty in standing for a long time".


Asunto(s)
Anciano , Femenino , Humanos , Masculino , Absorciometría de Fotón , Brazo , Densidad Ósea , Fémur , Cuello Femoral , Cadera , Estilo de Vida , Osteoporosis , Grosor de los Pliegues Cutáneos , Columna Vertebral , Circunferencia de la Cintura , Pesos y Medidas
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA