Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Añadir filtros








Intervalo de año
1.
Journal of the Korean Ophthalmological Society ; : 190-195, 2014.
Artículo en Coreano | WPRIM | ID: wpr-199071

RESUMEN

PURPOSE: To compare visual acuity and intraocular straylight after implantation of clear and photochromic intraocular lenses (IOLs) in a mesopic lighting condition. METHODS: Clear IOLs were implanted in 95 eyes of 72 patients (clear IOL group), and photochromic IOLs were implanted in 22 eyes of 16 patients (photochromic IOL group). Best-corrected visual acuity (BCVA) was measured indoors before surgery and 1 month after surgery. Straylight values were measured indoors before surgery and 1 and 2 months after surgery using the C-quant straylight meter (Oculus GmbH, Wetzlar, Germany). RESULTS: There were no significant differences between the 2 groups in BCVA at 1 month postoperatively (p = 0.587). Mean straylight values of clear and photochromic IOL groups were 2.76 +/- 1.89 log (s) and 2.88 +/- 2.04 log (s) preoperatively, 1.39 +/- 0.84 log (s) and 1.32 +/- 0.26 log (s) at 1 month postoperatively, and 1.43 +/- 0.92 log (s) and 1.45 +/- 0.50 log (s) at 2 months postoperatively. There were no significant differences between the 2 groups in indoor straylight values (p = 0.778, 0.709, 0.929, before surgery, 1 and 2 months after surgery respectively). Repeated-measure analysis of straylight values also showed no significant difference between the 2 groups (p > 0.05). CONCLUSIONS: There were no significant differences in BCVA and straylight values between clear and photochromic IOL groups under a mesopic light condition. Therefore, photochromic IOL could be suitable choice for cataract patients who spend significant time under mesopic conditions.


Asunto(s)
Humanos , Catarata , Lentes Intraoculares , Agudeza Visual
2.
Chinese Journal of Experimental Ophthalmology ; (12): 160-163, 2012.
Artículo en Chino | WPRIM | ID: wpr-635789

RESUMEN

BackgroundIn an ideal eye there would be no light scattering at all,but the eye media is not optically ideal.Intraocular straylight causes a veil of light and reduction in the contrast of the retinal image and thus decrease the quality of vision.ObjectiveThe present study was to investigate the repeatability and reproducibility of C-Quant straylight meter( Oculus,Germany)in measuring retinal straylight of myopia and post-laser in situ keratomileusis(LASIK) corneas.MethodsThis is a prospective research.The consecutive 35 eyes of 21 myopic patients and 34 eyes of 22 patients who received LASIK were included in this trail.Retinal straylight was measured for 7 times at a period of time and analyzed quantificational to evaluate the repeatability of measurement.Thirty-eight eyes of 19 patients were measured again at 3-7 days for 3 times at a period of time to assess the reproducibility of C-Quant straylight meter.The mean standard difference (SD) and coefficient of variation (CV) were used as the credibility evaluation.This clinical study complied with Helsinki Declaration and the informed consent was obtained prior to the medical procedure.ResultsThe straylight Log(s) of 7 times measurement were all less than 0.95.The mean Log(s) were 0.92±0.12 and 0.93±0.17 respectively in myopia group and post-LASIK group,without statistically significant differences among 7 times measurement( F=0.335,P=0.812;F=1.000,P=0.409).The mean SD for the 7 times measurement was 0.07 Log units.SD and CV increased with the number of measurements.The differences of mean SD and CV between 3 times result and 6 times result were significant different (t =-2.080,P =0.045;t =-2.190,P =0.035 ).No difference was found between different time periods( t =-0.531,P=0.598 ).The difference of the results between two measurements from the same patient was 0.013.ConclusionsC-Quant is a noncontact,noninvade,rapid and convenient method for the measurement of straylight in myopia and post-LASIK eyes due to the high repeatability and reproducibility.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA