Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 48
Filtrar
1.
J. res. dent ; 11(2): 1-19, Oct 2023.
Artículo en Inglés | LILACS-Express | LILACS | ID: biblio-1513034

RESUMEN

Aims: This systematic review aimed to evaluate whether calcium silicate-based sealers are less cytotoxicity and genotoxicity than epoxy resin-based sealers. Materials and Methods: Systematic searches were conducted for studies published up to September 27th, 2022, without restriction for language or year of publication, in the following databases: MEDLINE/PubMed, Scopus, Web of Science and Grey Literature Report. Only in vitrostudies that evaluated the cytotoxicity or genotoxicity of calcium silicate and epoxy resin-based sealers were included. The quality assessment was performed. Results: After duplicate removal and eligibility criteria assessment, a total of thirty-four studies were included. Twenty-eight studies had a low risk of bias, and six studies had amoderate risk of bias. In general, calcium silicate-based sealers had a lower cytotoxic and genotoxic potential than epoxy-resin based sealers.Conclusions: Based on the findings from in vitrostudies, calcium silicate-based sealers are less cytotoxic andgenotoxic than epoxy resin-based sealers

2.
Braz. dent. j ; 34(4): 54-61, July-Aug. 2023. tab, graf
Artículo en Inglés | LILACS-Express | LILACS, BBO | ID: biblio-1520342

RESUMEN

Abstract This study compared the pH and calcium ion release of calcium silicate- (Bio-C Temp) and calcium hydroxide-based (Ultracal XS) medications. Intracanal remnants of both medications were also evaluated using SEM-EDS after the removal protocol. Thirty-five bovine teeth were prepared. Fifteen were filled with Bio-C Temp and 15 with Ultracal XS. Five remained without intracanal medication (control group). Five samples from each experimental time (i.e.. 24, 72, and 168 hours) were used to measure pH and calcium ions release using a digital pH meter and microplate reader, respectively. Afterward, the peaks of the chemical elements composing both medications were analyzed in SEM-EDS. One-way ANOVA and Tukey's post hoc test analyzed the pH and calcium ion release data. Student's t-test compared the medications in each experimental time. SEM-EDS described the percentage of chemical elements in the samples. Bio-C Temp and Ultracal XS showed a significant pH increase from 24 to 168 hours (p<0.05). Ultracal XS showed a higher pH value at 24 hours than Bio-C Temp (p<0.05) but were similar at 72 and 168h (p > 0.05). Calcium ion release did not depend on the experimental period (p > 0.05). Bio-C Temp showed lower calcium ions release than Ultracal XS at 24 hours (p<0.05). SEM-EDS analyses showed the remains of both medications, but the concentration of Si, Al, and W ions was present only in the calcium silicate-based medication. Bio-C Temp presented alkaline pH and a satisfactory calcium ion release over the time. The remaining of both medications were present after the protocols for paste removal.


Resumo Este estudo comparou o pH e a liberação de íons cálcio de medicações intracanais a à base de silicato de cálcio (Bio-C Temp) e à base de hidróxido de cálcio (Ultracal XS). Remanescentes de ambas as medicações também foram avaliados usando microscopia eletrônica de varredura e espectroscopia de dispersão de energia após o protocolo de remoção. Trinta e cinco dentes bovinos foram preparados. Quinze dentes foram preenchidos com Bio-C Temp e 15 com Ultracal XS. Cinco permaneceram sem medicação intracanal (grupo controle). Cinco amostras de cada tempo experimental (ou seja, 24, 72 e 168 horas) foram usadas para medir o pH e a liberação de íons de cálcio usando um medidor de pH digital e um leitor de microplacas, respectivamente. Em seguida, os picos dos elementos químicos que compõem os dois medicamentos foram analisados ​​em microscopia eletrônica de varredura e por espectroscopia de dispersão de energia. Os testes One-way ANOVA e post hoc de Tukey analisaram os dados de pH e liberação de íons cálcio. O teste t de Student comparou as medicações em cada tempo experimental. A microscopia eletrônica de varredura e a espectroscopia de dispersão de energia descreveu a porcentagem de elementos químicos nas amostras. O Bio-C Temp e o Ultracal XS mostraram um aumento significativo de pH de 24 a 168 horas (p<0,05). O Ultracal XS apresentou um valor de pH mais alto em 24 horas do que o Bio-C Temp (p<0,05), mas foi semelhante em 72 e 168h (p > 0,05). A liberação de íons cálcio não dependeu do período experimental (p> 0,05). O Bio-C Temp apresentou menor liberação de íons de cálcio do que Ultracal XS em 24 horas (p<0,05). As análises de microscopia eletrônica de varredura e espectroscopia de dispersão de energia mostraram remanescentes de ambas as medicações, mas a concentração de íons Si, Al e W estavam presentes apenas na medicação à base de silicato de cálcio. O Bio-C Temp apresentou pH alcalino e maior liberação de íons cálcio. Remanescentes de ambas as medicações estiveram presentes após os protocolos de remoção da pasta.

3.
Braz. dent. j ; 34(2): 14-20, Mar.-Apr. 2023. graf
Artículo en Inglés | LILACS-Express | LILACS, BBO | ID: biblio-1439579

RESUMEN

Abstract The aim was to evaluate in vitro cytotoxicity and genotoxicity of Bio-C Repair (BCR), compared to Endosequence BC Root Repair (ERRM), MTA Angelus (MTA-Ang), and MTA Repair HP (MTA-HP). MC3T3 osteoblastic cells were exposed to extracts of the repairing bioceramic cements. After 1, 3, and 7 days, cytotoxicity and genotoxicity were evaluated by MTT and Micronucleus tests, respectively. Cells not exposed to biomaterials were used as a negative control. Data were compared using ANOVA two-way, followed by the Tukey Test (α=5%). MTA-Ang and MTA-HP showed no difference in relation to control regarding cytotoxicity in any experimental times. BCR and ERRM reduced cell viability after 3 and 7 days (p<0.05); however, the reduction caused by BCR was less than that caused by ERRM. Considering the micronucleus formation, all biomaterials caused an increase after 3 and 7 days (p<0.05), being greater for the BCR and ERRM groups. It can be concluded that BCR is non-cytotoxic in osteoblastic cells, as well as MTA-Ang e MTA Repair HP. BCR and ERRM showed greater genotoxicity than others tested biomaterials.


Resumo O objetivo foi avaliar in vitro a citotoxicidade e genotoxicidade do Bio-C Repair (BCR), em comparação com o Endosequence BC Root Repair (ERRM), MTA Angelus (MTA-Ang) e MTA Repair HP (MTA-HP). As células osteoblásticas MC3T3 foram expostas aos extratos dos cimentos biocerâmicos reparadores. Após 1, 3 e 7 dias, a citotoxicidade e a genotoxicidade foram avaliadas pelos testes MTT e Micronúcleo, respectivamente. Células não expostas aos biomateriais foram utilizadas como controle negativo. Os dados foram comparados por ANOVA de dois fatores, seguido do Teste de Tukey (p = 5 %). MTA-Ang e MTA-HP não apresentaram diferença em relação ao controle quanto à citotoxicidade em nenhum dos tempos experimentais. BCR e ERRM reduziram a viabilidade celular após 3 e 7 dias (p < 0,05); no entanto, a redução causada pelo BCR foi menor que aquela causada pelo ERRM. Todos os biomateriais causaram aumento na formação de micronúcleos após 3 e 7 dias (p < 0,05), sendo maior para os grupos BCR e ERRM. O BCR não é citotóxico em células osteoblásticas, assim como cimentos MTA-Ang e MTA Repair HP. BCR e ERRM apresentaram maior genotoxicidade do que outros biomateriais testados.

4.
Braz. dent. j ; 34(1): 1-11, Jan.-Feb. 2023. graf
Artículo en Inglés | LILACS-Express | LILACS, BBO | ID: biblio-1420576

RESUMEN

Abstract A continuous search for bioactive materials capable of supporting the replacement of damaged pulp tissue, with effective sealing potential and biocompatibility, has represented the attention of studies over the last decades. This study involves a narrative review of the literature developed by searching representative research in PUBMED/MEDLINE and searches in textbooks associated with the mechanism of action of bioactive materials (calcium hydroxide, mineral trioxide aggregate (MTA), and calcium silicate cements). The reflective analysis of the particularities of the chemical elements of these materials, considering the tissue and antibacterial mechanism of action, allows a better understanding of the characteristics and similarities in their tissue responses. Calcium hydroxide paste remains the antibacterial substance of choice as intracanal dressing for the treatment of root canal system infections. Calcium silicate cements, including MTA, show a favorable biological response with the stimulation of mineralized tissue deposition in sealed areas when in contact with connective tissue. This is due to the similarity between the chemical elements, especially ionic dissociation, the potential stimulation of enzymes in tissues, and the contribution towards an alkaline environment due to the pH of these materials. The behavior of bioactive materials, especially MTA and the new calcium silicate cements in the biological sealing activity, has been shown to be effective. Contemporary endodontics has access to bioactive materials with similar properties, which can stimulate a biological seal in lateral and furcation root perforations, root-end fillings and root fillings, pulp capping, pulpotomy, apexification, and regenerative endodontic procedures, in addition to other clinical conditions.


Resumo Uma busca contínua de materiais bioativos com capacidade de substituir o tecido pulpar danificado, com efetiva capacidade de selamento e biocompatibilidade, tem representado a atenção e foco de muitos estudos ao longo das últimas décadas. Este estudo envolve uma revisão narrativa da literatura desenvolvida por meio de pesquisas representativas encontradas no PUBMED/MEDLINE e pesquisas em livros didáticos associadas ao mecanismo de ação de materiais bioativos (hidróxido de cálcio, agregado de trióxido mineral (MTA) e cimentos de silicato de cálcio). A presente análise reflexiva das particularidades dos elementos químicos destes materiais bioativos, considerando o mecanismo de ação tecidual e antibacteriano, possibilita um melhor entendimento das características e similaridades no comportamento tecidual. A pasta de hidróxido de cálcio continua sendo a substância antibacteriana de escolha como medicação intracanal para o tratamento das infecções do sistema de canais radiculares. Este fato se deve a disponibilidade química de íons cálcio e hidroxila do hidróxido de cálcio aos tecidos, e a inibição enzimática bacteriana. Os cimentos de silicato de cálcio, dentre os quais inclui o MTA, apresentam uma resposta biológica favorável ao estímulo à deposição de tecido mineralizado nas áreas seladas e em contato com tecido conjuntivo. Este fato é decorrente da similaridade entre os elementos químicos, em especial devido a dissociação iônica, ao potencial estímulo de enzimas teciduais, e a contribuição com um meio alcalino decorrente do pH destes materiais. O comportamento dos materiais bioativos, em especial o MTA e os novos cimentos de silicato de cálcio na atividade de selamento biológico mostraram efetivos. A endodontia contemporânea atualmente conta com o potencial de materiais bioativos com propriedades análogas capaz de estimular o selamento biológico em perfurações radiculares laterais e de furca, em obturações radiculares, capeamento pulpar, pulpotomia, apicificação e procedimentos endodônticos regenerativos, além de outras condições clínicas.

5.
Braz. dent. j ; 34(1): 29-38, Jan.-Feb. 2023. tab, graf
Artículo en Inglés | LILACS-Express | LILACS, BBO | ID: biblio-1420580

RESUMEN

Abstract The aim of this study was to evaluate the physicochemical properties, cytotoxicity and bioactivity of a ready-to-use bioceramic material, Bio-C Repair (Angelus), in comparison with White MTA (Angelus) and Biodentine (Septodont). The physicochemical properties of setting time, radiopacity, pH, solubility, dimensional and volumetric changes were evaluated. Biocompatibility and bioactivity were assessed in Saos-2 osteoblast cell cultures by the MTT assay 3-(4,5-Dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide), Neutral Red (NR), Alizarin Red (ARS), and cell migration tests. Statistical analysis was performed by ANOVA, Tukey or Bonferroni tests (α = 0.05). Bio-C Repair had the longest setting time (p < 0.05), but radiopacity and solubility were accordance with the ISO 6876/2012 standards, besides linear expansion. Bio-C Repair and MTA had similar volumetric change (p > 0.05); lower than Biodentine (p < 0.05). All the materials evaluated had an alkaline pH. Bio-C Repair was cytocompatible and promoted mineralized nodule deposition in 21 days and cell migration in 3 days. In conclusion, Bio-C Repair had adequate radiopacity above 3mm Al, solubility less than 3%, dimensional expansion, and low volumetric change. In addition, Bio-C Repair promoted an alkaline pH and presented bioactivity and biocompatibility similar to MTA and Biodentine, showing potential for use as a repair material.


Resumo O objetivo deste estudo foi avaliar as propriedades físico-químicas, citotoxicidade e bioatividade de um novo material biocerâmico pronto para uso, Bio-C Repair (Angelus), em comparação com MTA Branco (Angelus) e Biodentine (Septodont). Foram avaliadas as propriedades físico-químicas de tempo de presa, radiopacidade, pH, solubilidade, alterações dimensionais e volumétricas. A biocompatibilidade, bioatividade e capacidade de reparo foram avaliadas em culturas de células de osteoblastos Saos-2 pelo ensaio MTT brometo de 3-(4,5-dimetiltiazol-2-il)-2,5-difeniltetrazólio), vermelho neutro (NR), vermelho de alizarina ( ARS) e testes de migração celular. A análise estatística foi realizada pelos testes ANOVA, Tukey ou Bonferroni (α = 0,05). Bio-C Repair apresentou o maior tempo de presa (p < 0,05), mas radiopacidade e solubilidade de acordo com as normas ISO 6876/2012, além de expansão linear. Bio-C Repair e MTA tiveram variação volumétrica semelhante (p > 0,05), menor que Biodentine (p < 0,05). Todos os materiais avaliados apresentaram pH alcalino. Bio-C Repair foi citocompatível, além de promover deposição de nódulos mineralizados em 21 dias e migração celular em 3 dias. Em conclusão, o Bio-C Repair apresentou radiopacidade adequada acima de 3mmAl, solubilidade menor que 3%, expansão dimensional e baixa perda volumétrica.. Além disso, o Bio-C Repair promoveu um pH alcalino e apresentou bioatividade e biocompatibilidade semelhantes ao MTA e Biodentine, mostrando potencial para uso como material reparador

6.
Braz. dent. j ; 34(6): 30-39, 2023. tab, graf
Artículo en Inglés | LILACS-Express | LILACS, BBO | ID: biblio-1528024

RESUMEN

Abstract This laboratory study aimed to evaluate the influence of endodontic sealer and cervical limit of root filling on the discoloration of root canal treated teeth. Bovine incisors were randomly distributed into six experimental groups and control (n=21/group), according to the endodontic sealer used [AH Plus (AP); MTA Fillapex (MF) and Sealer Plus BC (SPB)] and the cervical limit of root filling [dental cervix (DC) or 2 mm in apical direction (2mm-AD)]. Tooth discoloration (ΔE) was evaluated by a digital spectrophotometer using the CIED2000 method. Color assessments were performed immediately before (baseline), 1 week, 1, 3, 6 months, and 1 year after obturation. Data were analyzed by ANOVA and Tukey's post-hoc tests (α=5%). Teeth filled with the three sealers showed perceptible tooth discoloration (ΔE≥2.7) in 1 week, maintaining similar values over time. There was a significant difference between MF and SPB sealers in the 2mm-AD groups. In addition, 2mm-AD groups promoted significantly lower discoloration than DC groups for AH (3 months) and SPB (1 and 3 months) sealer,s. Teeth filled with AP, MF, and SPB sealers displayed discoloration from 1 week to one year, with differences between MF and SPB sealers. A cervical limit of filling material at 2 mm from the dental cervix seems more advisable, promoting lower crown discoloration.


Resumo O presente estudo laboratorial teve como objetivo avaliar a influência do cimento endodôntico e do limite cervical da obturação radicular na alteração de cor de dentes tratados endodonticamente. Incisivos bovinos foram distribuídos aleatoriamente em seis grupos experimentais e um controle (n=21/grupo), de acordo com o cimento endodôntico utilizado [AH Plus (AP); MTA Fillapex (MF) e Sealer Plus BC (SPB)] e o limite cervical da obturação [Colo dentário (CD) ou 2mm na direção apical (2mm-DA)]. A alteração de cor (ΔE) foi avaliada por um espectofotômetro digital usando o método CIED2000. As avaliações de cor foram realizadas imediatamente antes (baseline), 1 semana, 1, 3, 6 meses e 1 ano após a obturação. Os dados foram analisados pelos testes ANOVA e post-hoc de Tuckey (α=5%). Dentes obturados com os três cimentos apresentaram alteração de cor perceptível (ΔE≥2.7) em 1 semana, mantendo valores semelhantes ao longo do tempo. Houve uma diferença significativa entre os cimentos MF e SPB nos grupos 2mm-DA. Além disso, os grupos 2mm-DA promoveram uma alteração de cor significativamente menor do que o grupos CD para os cimentos AH (3 meses) e SPB (1 e 3 meses). Os dentes obturados com os cimentos AH, MF e SPB apresentaram alteração de cor entre 1 semana a um ano, com diferenças entre os cimentos MF e SPB. O limite cervical do material obturador a 2mm do colo dentário parece mais aconselhável, promovendo menor alteração de cor da coroa dentária.

7.
J. appl. oral sci ; 31: e20220444, 2023. tab, graf
Artículo en Inglés | LILACS-Express | LILACS | ID: biblio-1430630

RESUMEN

Abstract Few long-term studies assess the discoloration induced by hydraulic calcium silicate-based cement on dental structures. In addition, as far as we know, no long-term study has assessed the discoloration induced by these cement on composite resin. Objective This in vitro study aimed to assess, during a period of two years, the discoloration potential of different hydraulic calcium silicate-based cements (hCSCs) on the enamel/dentin structure and composite resin restoration. Methodology A total of 40 enamel/dentin discs were obtained from bovine incisors, and 40 composite resin discs (10 mm in diameter × 2 mm thick) were fabricated. A 0.8 mm-deep cavity was made in the center of each disc and filled with the following hCSCs (n=10): Original MTA (Angelus); MTA Repair HP (Angelus); NeoMTA Plus (Avalon); and Biodentine (Septodont). An initial color measurement was performed (T0 - baseline). After 7, 15, 30, 45, 90, 300 days, and two years, new color measurements were performed to determine the color (ΔE00), lightness (ΔL'), chroma (ΔC'), hue differences (ΔH'), and whiteness index (WID). Results For enamel/dentin, the ΔE00 was significant among groups and periods (p<0.05). NeoMTA Plus had the greatest ΔE00. The NeoMTA Plus group had the greatest ΔE00 after two years for composite resin. Significant reduction in lightness was observed for all groups after two years (p<0.05). The most significant WID values were observed after 30 days for Biodentine (enamel/dentin) and MTA Repair HP groups (composite resin) (p<0.05). Conclusions The hCSCs changed the colorimetric behavior of both substrates, leading to greater darkening over time. The Bi2O3 in the Original MTA seems relevant in the short periods of color change assessment.

8.
Rev. Ciênc. Méd. Biol. (Impr.) ; 21(3): 613-623, 20221229. fig, tab
Artículo en Portugués | LILACS | ID: biblio-1416609

RESUMEN

Introdução: os cimentos endodônticos obturadores à base de silicato de cálcio têm sido amplamente utilizados na endodontia, principalmente em razão de suas reconhecidas propriedades bioativas. Como consequência, uma quantidade expressiva de marcas comerciais foi lançada no mercado, dificultando a compreensão do profissional, principalmente no que diz respeito às diferentes composições químicas, apresentações, formas de uso e custo-benefício. Objetivos: o Objetivo deste trabalho foi analisar as diferenças composicionais, técnicas (indicações e apresentação comercial) e comerciais (custo e disponibilidade de venda) dos cimentos endodônticos obturadores à base de silicato de cálcio, disponíveis para uso e comercialização no Brasil. Metodologia: foi realizada uma busca sistemática no site da Anvisa, sendo identificados sete cimentos endodônticos obturadores biocerâmicos para uso no Brasil. As bulas dos produtos foram analisadas para verificação de composição, apresentação e indicação de uso. Sites especializados foram consultados para verificação de preço dos produtos. Resultados: observou-se que a composição química varia bastante, a depender do fabricante, sendo os silicatos tricálcico e dicálcico os componentes mais frequentes. A maioria dos cimentos é apresentada comercialmente pronta para uso, e possui óxido de zircônio como agente radiopacificador. A venda através de sites especializados ainda é restrita a alguns produtos, e o custo varia de acordo com a quantidade de material por embalagem. Conclusão: este trabalho apresentou as características composicionais, técnicas e comerciais de sete cimentos endodônticos obturadores à base de silicato de cálcio registrados na ANVISA e autorizados para uso no Brasil.


Introduction: calcium silicate-based endodontic sealers have been widely used in endodontics, mainly because of their recognized bioactive properties. As a result, a significant number of commercial brands were launched on the market, making it difficult for professionals their comprehension, especially with regard to different chemical compositions, presentations, forms of use and cost-effectiveness. Objective: the Objective of this work was to analyze the compositional, technical (indications and commercial presentation) and commercial (cost and availability) differences of calcium silicate-based endodontic sealers, available for use and commercialization in Brazil. Methodology: a systematic search was carried out on the Anvisa website, and seven bioceramic endodontic sealers for use in Brazil were identified. Product leaflets were analyzed to verify composition, presentation and indication of use. Specialized websites were consulted to verify the price of the products. Results: it was observed that the chemical composition varies a lot, depending on the manufacturer, with tricalcium and dicalcium silicates being the most frequent components. Most sealers are commercially available ready-to-use, and have zirconium oxide as a radiopacifying agent. The sale through specialized websites is still restricted to some products, and the cost varies according to the amount of material per package. Conclusion: this work presented the compositional, technical and commercial characteristics of seven calcium silicate-based endodontic sealers registered at ANVISA and authorized for use in Brazil.


Asunto(s)
Materiales de Obturación del Conducto Radicular , Obturación del Conducto Radicular , Cemento de Silicato , Calcarea Silicata , Cementos Dentales , Endodoncia
9.
Braz. dent. j ; 33(6): 20-27, Nov.-Dec. 2022. tab
Artículo en Inglés | LILACS-Express | LILACS, BBO | ID: biblio-1420560

RESUMEN

Abstract This study aimed to evaluate the influence of ultrasonic activation (UA) on the physicochemical properties of hydraulic calcium silicate-based sealers. Nine experimental conditions were created based on the hydraulic calcium silicate-based sealers (Bio-C Sealer, Sealer Plus BC and Bio Root RCS) and the ultrasonic activation (no activation [NA], 10 seconds, and 20 seconds). Then the experimental groups were BC-NA, BC-10, BC-20, SPBC-NA, SPBC-10, SPBC-20, BR-NA, BR-10, and BR-20. Activation was performed with an ultrasonic insert 20/.01. The mold for the physicochemical analysis was filled and evaluated according to the ANSI/ADA specification nº. 57: initial and final setting time, flow, radiopacity and solubility. Tests were also performed to evaluate pH and calcium ion release with experimental periods of 1, 24, 72, and 168 hours with a pH meter and colorimetric spectrophotometer. Data were analyzed by one-way analysis of variance and post-hoc Tukey tests. The significance level was set at 5%. The time of UA progressively delayed the initial setting time for all hydraulic calcium silicate-based sealers (p < 0.05). Twenty seconds of UA increased the mean flow values of Sealer Plus BC and Bio-C Sealer compared to NA (p < 0.05). UA did not influence the radiopacity and solubility of the tested sealers (p > 0.05). UA for 20 seconds enhanced the pH levels and the calcium ion release of Sealer Plus BC and Bio-C Sealer at 168h (p < 0.05). UA for twenty seconds interferes with some physicochemical properties of hydraulic calcium silicate-based sealers.


Resumo Este estudo teve como objetivo avaliar a influência da ativação ultrassônica nas propriedades físico-químicas de cimentos de silicato de cálcio. Nove condições experimentais foram criadas com base nos cimentos de silicato de cálcio (Bio-C Sealer, Sealer Plus BC e Bio Root RCS) e na ativação ultrassônica (sem ativação [SA], 10 segundos e 20 segundos). Os grupos experimentais foram BC-SA, BC-10, BC-20, SPBC-SA, SPBC-10, SPBC-20, BR-SA, BR-10 e BR-20. A ativação foi realizada com um inserto ultrassônico 20/.01. O molde para a análise físico-química foi preenchido e avaliado de acordo com a especificação ANSI/ADA nº. 57: tempo de presa inicial e final, escoamento, radiopacidade e solubilidade. Também foram realizados testes para avaliação de pH e liberação de íons cálcio com períodos experimentais de 1, 24, 72 e 168 horas com pHmetro e espectrofotômetro colorimétrico. Os dados foram analisados por análise de variância one-way e testes post-hoc de Tukey. O nível de significância foi estabelecido em 5%. O tempo de AU aumentou progressivamente o tempo de presa inicial para todos os cimentos de silicato de cálcio (p < 0,05). Vinte segundos de AU aumentaram os valores médios de escoamento de Sealer Plus BC e Bio-C Sealer em comparação com SA (P < 0,05). A AU não influenciou a radiopacidade e a solubilidade dos cimentos testados (P > 0,05). AU por 20 segundos aumentou os níveis de pH e a liberação de íons cálcio de Sealer Plus BC e Bio-C Sealer em 168h (P < 0,05). AU por vinte segundos interfere em algumas propriedades físico-químicas dos cimentos de silicato de cálcio.

10.
Braz. dent. j ; 33(5): 18-25, Sep.-Oct. 2022. tab, graf
Artículo en Inglés | LILACS-Express | LILACS, BBO | ID: biblio-1403783

RESUMEN

Abstract Calcium silicate-based root canal sealers have been developed in powder/liquid or premixed ready-to-use forms. The evaluation of the physico-chemical properties of a prototype powder/liquid MTApex Sealer (Ultradent) in comparison to a ready-to-use material EndoSequence BC Sealer (Brasseler) was performed. The paste/paste epoxy resin-based AH Plus (Dentsply) served as control for comparisons. The sealers were evaluated (n = 6) regarding setting time (in dry and moist environments), flow and radiopacity, following the ISO-6876/2012 standard. Also, the pH was assessed. Material's surface and chemical characterization was evaluated using scanning-electron-microscopy (SEM) and energy-dispersive-spectrometry (EDS). Mixed ANOVA, Shapiro-Wilk, Levene, and post-hoc analysis with Bonferroni correction were performed at a significance level of 5%. MTApex Sealer exhibited the highest flow and EndoSequence BC Sealer had a significantly longer setting time in dry compared to the moist environment; however, for MTApex Sealer and AH Plus no significant changes occurred when additional moisture was provided. All materials exceeded 7 mm Al of radiopacity and showed a decreasing alkalinity over the 21 day-analysis. SEM/EDS evaluation resulted in peaks of calcium, silicon, and the respective radiopacifier. The prototype powder/liquid MTApex Sealer had the highest flow and similar setting time in both dry and moist environments; opposingly, EndoSequence BC Sealer was crucially influenced by external moisture. This suggests that the powder/liquid materials' setting seems to be more predictable.


Resumo Os cimentos endodônticos obturadores à base de silicato de cálcio foram desenvolvidos em formas pó/líquido ou pré-misturadas prontas para o uso. Foi realizada a avaliação das propriedades físico-químicas de um protótipo pó/líquido MTApex Sealer (Ultradent) em comparação com um material pronto para uso EndoSequence BC Sealer (Brasseler). O cimento obturador pasta/pasta à base de resina epóxi AH Plus (Dentsply) serviu de controle para as comparações. Os cimentos foram avaliados (n = 6) quanto a: tempo de presa (em ambientes secos e úmidos), escoamento e radiopacidade, seguindo a norma ISO-6876/2012; como também o pH. A superfície do material e a caracterização química foram realizadas utilizando a microscopia eletrônica de varredura (MEV) e espectrometria dispersiva de energia (EDS). ANOVA, Shapiro-Wilk, Levene e análise post-hoc com correção de Bonferroni foram realizadas com nível de significância de 5%. O MTApex Sealer exibiu um escoamento mais alto e o EndoSequence BC Sealer teve um tempo de presa significativamente mais longo em ambiente seco em comparação com o ambiente úmido; entretanto, para MTApex Sealer e AH Plus, nenhuma mudança significativa ocorreu quando umidade adicional foi fornecida. Todos os materiais excederam 7 mm de Al de radiopacidade e mostraram uma alcalinidade decrescente ao longo dos 21 dias de análise. A avaliação MEV/EDS resultou em picos de cálcio, silício e respectivo radiopacificador. O protótipo de pó/líquido MTApex Sealer teve o maior escoamento e tempo de presa semelhante em ambientes secos e úmidos; ao contrário, o EndoSequence BC Sealer foi influenciado de maneira crucial pela umidade externa. Isso sugere que a configuração dos materiais em pó/líquido parece ser mais previsível.

11.
Braz. dent. j ; 33(2): 91-98, Mar.-Apr. 2022. tab, graf
Artículo en Inglés | LILACS-Express | LILACS, BBO | ID: biblio-1374624

RESUMEN

Abstract This study aimed to evaluate the influence of calcium silicate-based sealers on the bond strength of fiber posts using conventional and self-adhesive resin cement. Sixty single-rooted teeth were selected. The canals were prepared with a reciprocating instrument 40.06. The roots were randomly distributed in six groups (n = 10) according to the strategies for root canal filling and fiber posts cementation: AH Plus/RelyX ARC; AH Plus/RelyX U200; Bio C Sealer/RelyX ARC; Bio C Sealer/RealyX U200; Sealer Plus BC/RelyX ARC; and Sealer Plus BC/RelyX U200. The roots were transversally sectioned, and one slice per post-third was obtained. The push-out test was performed at a crosshead speed of 1mm/min. The failure patterns were described after assessment with a stereomicroscope with a 10× magnification. Bond strength was calculated and analyzed using the ANOVA and Tukey test. AH Plus did not influence the bond strength of fiber posts cemented with conventional (RelyX ARC) or with self-adhesive resin cement (RelyX U200). The lowest bond strength values were obtained when calcium silicate-based sealers were associated with conventional resin cement (Bio C Sealer/RelyX ARC and Sealer Plus BC/RelyX ARC). Except for Sealer Plus BC/RelyX ARC, all groups presented lower bond strength at the apical portion compared to the cervical portion of the post. Adhesive failures between cement and post and cement and dentin were predominant (55.3%). Calcium silicate-based sealers decreased the bond strength of fiber posts cemented with conventional resin cement.


Resumo Este estudo teve como objetivo avaliar a influência de cimentos à base de silicato de cálcio na resistência de união de pinos de fibra utilizando cimentos resinosos convencionais e autoadesivos. Sessenta dentes humanos monorradiculares foram selecionados. Os canais foram preparados um instrumento reciprocante 40.06. As raízes foram distribuídas aleatoriamente em seis grupos (n = 10) de acordo com as estratégias de obturação do canal e cimentação dos pinos de fibra: AH Plus/RelyX ARC; AH Plus/RelyX U200; Bio C Sealer/RelyX ARC; Bio C Sealer/RealyX U200; Sealer Plus BC/RelyX ARC; e Sealer Plus BC/RelyX U200. As raízes foram seccionadas transversalmente e foi obtido um espécime por terço. O teste de push-out foi realizado em uma velocidade de 1mm/min. Os padrões de falha foram descritos após avaliação em estereomicroscópio com aumento de 10×. A resistência de união foi calculada e analisada por ANOVA e teste de Tukey. AH Plus não influenciou na resistência de união dos pinos de fibra cimentados com cimento resinoso convencional (RelyX ARC) ou autoadesivo (RelyX U200) (p > 0,05). Os menores valores de resistência de união foram obtidos quando os cimentos à base de silicato de cálcio foram associados ao cimento resinoso convencional (Bio C Sealer/RelyX ARC e Sealer Plus BC/RelyX ARC) (p < 0,05). Com exceção do Sealer Plus BC/RelyX ARC, todos os grupos apresentaram menor resistência de união na porção apical em comparação com a porção cervical do pino (p < 0,05). Falhas adesivas entre cimento e pino e cimento e dentina foram predominantes (55,3%). Cimentos a base de silicato de cálcio diminuíram a resistência de união de pinos de fibra cimentados com cimento resinoso convencional.

12.
J. res. dent ; 10(1): 14-19, jan.-mar2022.
Artículo en Inglés | LILACS | ID: biblio-1378183

RESUMEN

Introduction: This study aimed to evaluate the dentinal tubule penetration of an endodontic bioceramic sealer, Sealer Plus BC, after three final irrigation protocols. Methods: Thirty distobuccal roots of maxillary molars were selected. Root canal preparation was performed up to an #40.06 instrument (X1 Blue) under 2.5% sodium hypochlorite irrigation. Specimens were randomly divided into three groups (n=10), according to the final irrigation protocol: G-NaOCl (2.5% sodium hypochlorite + PUI), G-SS (0.9% saline solution + PUI) and G-H20 (Deionized water + PUI). After final irrigation protocols, all specimens were irrigated with phosphate buffer solution. Root canal obturation was performed using the single cone technique and Sealer Plus BC, stained with a specific fluorophore. Specimens were transversely sectioned and each root third was evaluated in a confocal scanning laser microscopy. Images obtained were analyzed for sealer penetration in the dentinal tubules. Results: Dentinal tubule penetration of Sealer Plus BC was not observed in any root third, regardless of the final irrigation protocol investigated. Conclusions: Sealer Plus BC dentinal tubule penetration was not observed after none of the protocols tested. Dentinal tubule penetrability of Sealer Plus BC may be related to other factors rather than the final irrigation protocol.


Asunto(s)
Selladores de Fosas y Fisuras , Selladores de Fosas y Fisuras/uso terapéutico , Cementos Dentales/uso terapéutico , Hipoclorito de Sodio/uso terapéutico , Tampones (Química) , Bisfenol A Glicidil Metacrilato/análisis
13.
J. appl. oral sci ; 30: e20220086, 2022. graf
Artículo en Inglés | LILACS-Express | LILACS | ID: biblio-1405373

RESUMEN

Abstract Bioactive molecules present the potential to be used along with biomaterials in vital pulp therapy and regenerative endodontic treatment. Objective The aim of this study was to assess the effects of the combined use of bone morphogenetic protein-7 (BMP-7) and mineral trioxide aggregate (MTA) on the proliferation, migration, and differentiation of human dental pulp stem cells (DPSCs). Methodology For the proliferation analysis, DPSCs were incubated with a growth medium and treated with MTA and/or BMP-7 at different concentrations. For the following analyses, DPSCs were incubated with a differentiation medium and treated with MTA and/or BMP-7. Moreover, there were groups in which DPSCs were incubated with the growth medium (control), the differentiation medium, or DMEM/F12 containing fetal bovine serum, and not treated with MTA or BMP-7. Cell proliferation was analyzed using the WST-1 assay. The odontogenic/osteogenic differentiation was evaluated by immunocytochemistry, alkaline phosphatase (ALP) activity assay, alizarin red staining, and reverse transcription-quantitative polymerase chain reaction (RT-qPCR). Cell migration was evaluated using a wound-healing assay. Data were analyzed using analysis of variance and Tukey test (p=0.05). Results The use of BMP-7 with MTA presented no significant effect on cell proliferation in comparison with the treatment with MTA alone (p>0.05), but showed higher ALP activity, increased mineralization, and higher expression of DMP1 and DSPP when compared with other groups (p<0.05). Nestin expression was higher in the control group than in groups treated with MTA and/or BMP-7 (p<0.05). The cell migration rate increased after treatment with MTA when compared with other groups in all periods of time (p<0.05). At 72 hours, the wound area was smaller in groups treated with MTA and/or BMP-7 than in the control group (p<0.05). Conclusion The use of BMP-7 with MTA increased odontogenic/osteogenic differentiation without adversely affecting proliferation and migration of DPSCs. The use of BMP-7 with MTA may improve treatment outcomes by increasing repair and regeneration capacity of DPSCs.

14.
Braz. dent. sci ; 25(4): 1-10, 2022. tab, ilus, graf
Artículo en Inglés | LILACS, BBO | ID: biblio-1395952

RESUMEN

Objective: Endodontic perforation is a challenging mishap that should be repaired with a biocompatible material, Mineral trioxide aggregate (MTA) and Biodentine are the most commonly used repair materials. However, these materials are expensive, (MTA) has prolonged setting time and difficult manipulation. The purpose of this study is to prepare the experimental nano calcium-aluminate/tri-calcium-silicate (CA/C3S) material and comparing its physical properties with biodentine and MTA, to evaluate the experimental material eligibility to compete the commercial repair materials. And to perform part two (animal study) that will evaluate the cytotoxicity, the biocompatibility and the efficacy of (CA/C3S) in furcal perforation repair compared to diode laser. Material and Methods: A mixture of calcium carbonate and aluminum oxide was used to formulate calcium aluminate phase (CA), tri-calcium-Silicate phase (C3S) was formulated by firing of calcium carbonate and quartz. The produced powders were investigated by X-ray diffraction, then (CA) and (C3S) mixed with water.(CA/ C3S) compared with MTA and biodentine for setting-time, micro-hardness, dimensional-stability and solubility. Results: Mean setting time of (CA/C3S) was (32.70±0.75min) which is significantly higher than MTA and Biodentine. The Mean microhardness of (CA/C3S) was (56.50±7.41VHN) which has no statical difference with MTA and Biodentine. Solubility results showed weight increase for (CA/C3S) as following (6.29±3.05)and loss of weight for MTA and Biodentine. The percentage of change in dimensions for(CA/C3S) increased as following (0.64±0.78) while decreased for MTA and Biodentine. Conclusion: The experimental (CA/C3S) material showed good microhardness, dimensional stability and acceptable setting time that could be improved in further work (AU)


Objetivo: A perfuração endodôntica é um percalço desafiador que deve ser reparado com um material biocompatível, Agregado de trióxido mineral (MTA) e Biodentina são os materiais de reparo mais comumente usados. No entanto, esses materiais são caros, (MTA) tem tempo de presa prolongado e difícil manipulação. O objetivo deste estudo é preparar o material experimental de nano aluminato de cálcio/silicato tricálcico (CA/C3S) e comparar suas propriedades físicas com biodentina e MTA, para avaliar a elegibilidade do material experimental para competir com os materiais de reparo comerciais. E realizar a segunda parte (estudo animal) que avaliará a citotoxicidade, a biocompatibilidade e a eficácia do (CA/C3S) no reparo de perfuração de furca em comparação ao laser de diodo.Material e Métodos: Uma mistura de carbonato de cálcio e óxido de alumínio foi usada para formular a fase de aluminato de cálcio (CA), a fase tri-cálcio-silicato (C3S) foi formulada por queima de carbonato de cálcio e quartzo. Os pós produzidos foram investigados por difração de raios X, em seguida (CA) e (C3S) misturados com água. (CA/ C3S) comparados com MTA e biodentina para tempo de presa, microdureza, estabilidade dimensional e solubilidade. Resultados: O tempo médio de presa de (CA/C3S) foi (32,70±0,75min) que é significativamente maior que MTA e Biodentine. A microdureza média de (CA/C3S) foi (56,50±7,41VHN) que não tem diferença estática com MTA e Biodentine. Os resultados de solubilidade mostraram aumento de peso para (CA/C3S) conforme a seguir (6,29±3,05) e perda de peso para MTA e Biodentine. A porcentagem de mudança nas dimensões para (CA/C3S) aumentou como segue (0,64±0,78), enquanto diminuiu para MTA e Biodentine. Conclusão: O material experimental (CA/C3S) apresentou boa microdureza, estabilidade dimensional e aceitável tempo de presa, que pode ser melhorado em trabalhos futuros (AU)


Asunto(s)
Difracción de Rayos X , Materiales Biocompatibles , Carbonato de Calcio , Láseres de Estado Sólido , Óxido de Aluminio
15.
Rev. Asoc. Odontol. Argent ; 109(2): 76-80, ago. 2021. tab
Artículo en Español | LILACS | ID: biblio-1348357

RESUMEN

esumen Objetivo: Comparar la microdureza de dos materiales endodónticos a base de silicato de calcio: MTA Densell Endo Sealer y TotalFill BC Sealer. Materiales y métodos: Se evaluó la microdureza de los selladores MTA Densell Endo Sealer (Grupo 1, n=5) y To- talFill BC Sealer (Grupo 2, n=5) contenidos en cilindros de dentina de vacuno a los 14 días posteriores a su fraguado. La medición se realizó a temperatura ambiente mediante la prue- ba de indentación Vickers. Se realizaron cinco indentaciones por probeta con una carga de 100 g durante 10 s cada una. Las mediciones se convirtieron a valores de dureza Vickers (HV) y los promedios de los valores HV de cada grupo se compararon por medio de la prueba t de Student con un nivel de significación de P <0,05. Resultados: A los 14 días, luego del fraguado, la mi- crodureza de MTA Densell Endo Sealer fue significativamen- te mayor (P=0,001) que la de TotalFill BC Sealer. Conclusiones: Los resultados sugieren que a causa de su dureza la remoción de MTA Densell Endo Sealer puede resultar dificultosa cuando está indicado un retratamiento (AU)


Aim: To compare the microhardness of two silicate-based endodontic materials: MTA Densell Endo Sealer and Total Fill BC Sealer. Materials and methods: Samples of MTA Densell Endo Sealer (Group 1, n=5) and Total Fill BC Sealer (Group 2, n=5) contained into cow dentine cylinders were subjected to the Vickers Microhardness Indentation test at room temper- ature and 14 days after setting. Five indentations per sample were performed under a load of 100 g for 10 s. The indenta- tion measurements were converted into hardness values (HV). Mean HV values of each group were compared using the Stu- dent t test at a significance level of P <0,05. Results: 14 days after setting, the microhardness of MTA Densell Endo Sealer was significantly greater (P=0,001) than that of Total Fill BC Sealer. Conclusions: The results of this study suggest that due to its hardness the removal of MTA Densell Endo Sealer could be difficult to perform when a root canal retreatment is indicated (AU)


Asunto(s)
Materiales de Obturación del Conducto Radicular , Cemento de Silicato , Pruebas de Dureza , Ensayo de Materiales
16.
Braz. dent. j ; 32(4): 1-7, July-Aug. 2021. tab, graf
Artículo en Inglés | LILACS, BBO | ID: biblio-1345516

RESUMEN

Abstract This study evaluated the 3D quality of root-end filling, assessing the presence (volume and percentage) of marginal gaps and internal voids formed after retro-filling with three calcium silicate-based materials: MTA Angelus (Angelus Soluçoes Odontologicas, Londrina, PR, Brazil), Biodentine (Septodont Ltd., Saint Maur-des-Faussés, France) and Neo MTA Plus (Avalon Biomed Inc., Bradenton, Florida, US). Thirty human, extracted, single rooted teeth were used. Orthograde root canal treatment, root resection (3mm shorter than the apex) and retrograde cavity preparation with ultrasonic tips were performed. Teeth were divided into 3 groups (n =10 each) following a stratified randomization according to the initial volume of the root-end cavity. After retrofilling, samples were stored for 7 days. Then, two rounds of micro-CT scans were performed: soon after root-end preparation (with the cavity still empty) and 7 days after root-end filling. Marginal gaps, internal voids volume (mm3 and %), as well as, the overall defects (sum of gaps and voids) were evaluated. Statistics compared the three groups in relation to those defects. There was not statistical difference between groups regarding the marginal gaps (P≥ 0.05), the internal voids (P≥ 0.05), and the overall defects (P≥ 0.05). Median (mm3) and % of overall air-entrapment defects (gaps and/or voids) was: 0.004mm3 and 1.749% for MTA Angelus, 0.018mm3 and 6.660% for Biodentine, and 0.012mm3 and 4.079% for Neo MTA Plus. All materials had gaps and/or voids. No differences were found between MTA Angelus, Biodentine and Neo MTA Plus.


Resumo Este estudo avaliou a qualidade 3D de retro-obturações, avaliando a presença (volume e percentagem) de "gaps" marginais e "voids" internos formados a partir da retro-obturação com três materiais à base de silicato de cálcio: MTA Angelus (Angelus Soluções Odontológicas, Londrina, PR, Brasil), Biodentine (Septodont Ltd., Saint Maur-des-Faussés, França) and Neo MTA Plus (Avalon Biomed Inc., Bradenton, Flórida, US). Trinta dentes humanos unirradiculares extraídos foram usados. Após tratamento de canal ortrógrado, resecção radicular (3 mm apicais), o prepare da cavidade retrógrada com pontas ultrassônicas foi realizado. Os dentes foram divididos em três grupos (n= 10 cada) seguindo uma randomização estratificada, de acordo com o volume inicial da cavidade retrógrada. Depois da retro-obturação as amostras foram armazenadas por 7 dias. Duas rodadas de escaneamento de micro-CT foram realizadas: logo após o preparo retrógrado (com a cavidade ainda vazia) e 7 dias após a retro-obturação. O volume de "gaps" marginais e de "voids" internos (mm3 e %), bem como, os defeitos totais (soma de "gaps" e "voids") foram avaliados. Não houve diferença estatística entre os grupos em relação aos "gaps" marginais (P≥ 0,05), "voids" internos (P≥ 0,05), e aos defeitos totais (P≥ 0,05). A mediana (mm3) e porcentagem dos defeitos totais de aprisionamento de ar foi 0,004mm3 e 1,749% para o MTA Angelus, 0,018mm3 e 6,660% para o Biodentine, e 0,012mm3 e 4,079% para o Neo MTA Plus. Todos os materiais tiveram defeitos ("gaps"e/ou "voids"). Não houve diferença entre MTA Angelus, Biodentine e Neo MTA Plus.


Asunto(s)
Humanos , Materiales de Obturación del Conducto Radicular , Obturación del Conducto Radicular , Tratamiento del Conducto Radicular , Silicatos , Compuestos de Calcio , Microtomografía por Rayos X
17.
Braz. dent. j ; 32(4): 8-18, July-Aug. 2021. tab, graf
Artículo en Inglés | LILACS, BBO | ID: biblio-1345521

RESUMEN

Abstract The aim of this study was to evaluate the physicochemical properties, cytocompatibility and antibiofilm activity of a new calcium silicate-based endodontic sealer, Sealer Plus BC (MK Life, Brazil), in comparison with TotalFill BC Sealer (FKG Dentaire SA, Switzerland) and AH Plus (Dentsply, Germany). Setting time and flow were evaluated based on ISO 6876 standard. The pH was evaluated after different periods, and radiopacity by radiographic analysis (mmAl). Solubility (% mass loss) and volumetric change (by micro-CT) were assessed after 30 days of immersion in distilled water. Cytocompatibility was assessed by methyltetrazolium (MTT) and neutral red (NR) assays, after exposure of Saos-2 cells to the sealer extract for 24 h. An additional analysis was performed by using MTT assay after 1, 3 and 7 days of exposure of Saos-2 to the sealers 1:8 dilution extracts. Antibiofilm activity against Enterococcus faecalis and/or Candida albicans was evaluated by crystal violet assay and modified direct contact test. The physicochemical properties were analyzed using ANOVA/Tukey tests; MTT and NR data were analyzed by ANOVA and Bonferroni tests; the antimicrobial tests were analyzed by Kruskal-Wallis and Dunn tests (α=0.05). Sealer Plus BC had proper setting time, radiopacity, flow and alkalization capacity. Sealer Plus BC was significantly more soluble than AH Plus (p<0.05) and presented volumetric change similar to AH Plus and TotalFill BC (p>0.05). Sealer Plus BC presented antibiofilm activity and no cytotoxic effect. In conclusion, although Sealer Plus BC had higher solubility, this sealer showed proper physicochemical properties, cytocompatibility, and antibiofilm activity.


Resumo O objetivo deste estudo foi avaliar as propriedades físico-químicas, a citocompatibilidade e a atividade antibiofilme de um novo cimento endodôntico à base de silicato de cálcio, Sealer Plus BC (MK Life, Brasil), em comparação com TotalFill BC Sealer (FKG Dentaire SA, Suíça) e AH Plus (Dentsply, Alemanha). O tempo de presa e o escoamento foram avaliados com base nas normas ISO 6876. O pH foi avaliado após diferentes períodos, e a radiopacidade por análise radiográfica (mmAl). A solubilidade (% de perda de massa) e alteração volumétrica (por micro-CT) foram avaliadas após 30 dias de imersão em água destilada. Citocompatibilidade foi avaliada pelos ensaios metiltetrazólio (MTT) e vermelho neutro (NR), após exposição das células Saos-2 ao extrato de cimento por 24 horas. Análise adicional foi realizada através do ensaio MTT após 1, 3 e 7 dias de exposição das células Saos-2 aos extratos dos cimentos na diluição de 1:8. Atividade antibiofilme contra Enterococcus faecalis e/ou Candida albicans foi avaliada pelos ensaios cristal violeta e contato direto modificado. As propriedades físico-químicas foram analisadas utilizando os testes ANOVA e Tukey; MTT e NR foram analisados pelos testes ANOVA e Bonferroni; os ensaios antimicrobianos foram analisados pelos testes Kruskal-Wallis e Dunn (α=0.05). Sealer Plus BC apresentou tempo de presa, radiopacidade e escoamento adequados, além de capacidade de alcalinização. Sealer Plus BC foi significantemente mais solúvel que AH Plus (p<0.05) e apresentou alteração volumétrica similar à de AH Plus e TotalFill BC (p>0.05). Sealer Plus BC apresentou atividade antibiofilme, sem efeito citotóxico. Como conclusão, embora Sealer Plus BC apresente maior solubilidade, este cimento apresentou propriedades físico-químicas adequadas, citocompatibilidade e atividade antibiofilme.


Asunto(s)
Materiales de Obturación del Conducto Radicular/farmacología , Ensayo de Materiales , Silicatos/farmacología , Compuestos de Calcio/farmacología , Biopelículas , Resinas Epoxi
18.
Odovtos (En línea) ; 22(3)dic. 2020.
Artículo en Inglés | LILACS, SaludCR | ID: biblio-1386497

RESUMEN

Abstract Differences in liquid-to-powder ratio can affect the properties of calcium silicate-based materials. This study assessed the influence of powder-to-gel ratio on physicochemical properties of NeoMTA Plus. Setting time (minutes), flow (mm and mm²), pH (at different periods), radiopacity (mm Al) and solubility (% mass loss) were evaluated using the consistencies for root repair material (NMTAP-RP; 3 scoops of powder to 2 drops of gel) and root canal sealer (NMTAP-SE; 3 scoops of powder to 3 drops of gel), in comparison to Biodentine cement (BIO) and TotalFill BC sealer (TFBC). Statistical analysis was performed using one-way ANOVA and Tukey tests (α=0.05). BIO had the shortest setting time, followed by NMTAP-RP and NMTAP-SE. TFBC showed the highest setting time and radiopacity. BIO, NMTAP-RP, and NMTAP-SE had similar radiopacity. All materials promoted an alkaline pH. NMTAP-RP/SE presented lower solubility than BIO and TFBC. Regarding the flow, TFBC had the highest values, followed by NMTAP-SE, and NMTAP-RP. BIO had the lowest flow. In conclusion, NMTAP in both powder-to-gel ratios showed high pH and low solubility. The increase in the powder ratio decreased the setting time and flow. These findings are important regarding the proper consistency and work time to clinical application.


Resumen Las diferencias en la proporción líquido/polvo pueden afectar las propiedades de los materiales a base de silicato de calcio. Este estudio evaluó la influencia de la proporción polvo/gel en las propiedades fisicoquímicas del cemento NeoMTA Plus. El tiempo de fraguado (minutos), la fluidez (mm y mm²), el pH (en diferentes períodos), la radiopacidad (mmAl) y la solubilidad (% de pérdida de masa) fueron evaluados utilizando las consistencias para el material de reparación radicular (NMTAP-RP; 3 cucharadas de polvo/2 gotas de gel) y para cemento sellador del conducto radicular (NMTAP-SE; 3 cucharadas de polvo/3 gotas de gel), en comparación con el cemento Biodentine (BIO) y el cemento TotalFill BC (TFBC). El análisis estadístico se realizó utilizando las pruebas ANOVA y Tukey unidireccionales (α=0.05). BIO tuvo el tiempo de fraguado más corto, seguido de NMTAP-RP y NMTAP-SE. TFBC mostró el mayor tiempo de fraguado y radiopacidad. BIO, NMTAP-RP y NMTAP-SE tuvieron una radiopacidad similar. Todos los materiales promovieron un pH alcalino. NMTAP-RP/ SE tuvieron una solubilidad menor que BIO y TFBC. Con respecto a la fluidez, TFBC tuvo los valores más altos, seguido de NMTAP-SE y NMTAP-RP. BIO tuvo la fluidez más baja. En conclusión, NMTAP en la relación polvo/gel mostró un pH alto y una baja solubilidad. El aumento en la proporción de polvo disminuyó el tiempo de fraguado y la fluidez. Estos hallazgos son importantes con respecto a su consistencia y tiempo de trabajo durante la aplicación clínica.


Asunto(s)
Calcarea Silicata/análisis , Química Física , Cemento Dental
19.
Salud UNINORTE ; 36(3): 587-605, sep.-dic. 2020. tab
Artículo en Español | LILACS-Express | LILACS | ID: biblio-1347866

RESUMEN

RESUMEN La biodentine es un biomaterial a base de silicato de calcio que ha sido concebido como un sustituto de la dentina. Es frecuentemente utilizada en diversas situaciones clínicas, como el recubrimiento pulpar (directo e indirecto), la pulpotomía, perforaciones endodónticas, apexificación, entre otras. El objetivo de esta revisión es proporcionar un análisis detallado de las propiedades fisicoquímicas, biológicas y las principales aplicaciones clínicas de la biodentine. Se realizó una búsqueda electrónica de literatura en las bases de datos Medline (Pubmed), EBS-CO-Host y Science direct (Elsevier) hasta julio de 2020. El 92 % de los artículos referenciados en esta revisión fueron seleccionados a través de esta búsqueda. Los resultados indican que la biodentine es un cemento de uso odontológico con excelentes propiedades que se caracteriza por una manipulación relativamente fácil, bajo costo, alta resistencia a la compresión y flexión, alta biocompatibilidad y una excelente bioactividad. En conclusión, la biodentine es un material recomendado en el tratamiento de diversas situaciones clínicas de la práctica odontológica dadas sus características fisicoquímicas y biológicas. Sin embargo, se hace necesario ensayos clínicos controlados aleatorizados que permitan determinar y confirmar que la biodentine es realmente un material odontológico capaz de reemplazar la dentina.


ABSTRACT Biodentine is a calcium silicate-based biomaterial that has been conceived as a substitute for dentin. It is frequently used in various clinical situations such as pulp lining (direct and indirect), pulpotomy, endodontic perforations, apexification, among others. The objective of this review is to provide a detailed analysis of the physical-chemical, biological properties and the main clinical applications of biodentine. An electronic literature search was carried out in the databases Medline (Pubmed), EBSCO-Host and Science direct (Elsevier) until July 2020. 92 % of the articles referenced in this review were selected through this search. The results indicate that biodentine is a cement for dental use with excellent properties characterized by relatively easy handling, low cost, high compressive and flexural strength, high biocompatibility and excellent bioactivity. In conclusion, biodentine is a recommended material in the treatment of various clinical situations in dental practice given its physicochemical and biological characteristics. However, randomized controlled clinical trials are necessary to determine and confirm that biodentine is indeed a dental material capable of replacing dentin.

20.
Braz. dent. j ; 31(6): 611-616, Nov.-Dec. 2020. tab, graf
Artículo en Inglés | LILACS, BBO | ID: biblio-1132345

RESUMEN

Abstract The aim of this study was to evaluate the antibacterial potential of a calcium silicate-based sealer (Bio-C Sealer, Angelus) against common bacteria in primary and secondary endodontic infections. Enterococcus faecalis, Escherichia coli, Pseudomonas aeruginosa, Staphylococcus aureus and Streptococcus mutans were exposed to fresh Bio-C Sealer for 24 h by the agar diffusion method (n=5). Additionally, the antibacterial activity was investigated against E. faecalis and S. mutans biofilms (48 h old) grown in discs with 4 mm in diameter and 2 mm in height. (n=3) of set discs of Bio-C Sealer (Angelus), EndoFill (Dentsply-Mallefer), Sealer 26 (Dentsply), AH Plus (Dentsply), Sealapex (Sybron-Endo) and EndoSequence BC Sealer (Brasseler). The antibacterial activity was evaluated by colony forming unity (CFU) counting using ImageJ software. Data were compared by one-way ANOVA followed by Holm-Sidak test (a=5%). Fresh Bio-C Sealer exhibited antimicrobial activity against all bacteria evaluated by agar diffusion method, except for S. mutans. Set discs of all endodontic sealers tested showed similar CFU values for E. faecalis (p>0.05). S. mutans in biofilms showed higher susceptibility to EndoFill compared with the other sealers (p<0.05). In conclusion, the results indicate that fresh Bio-C Sealer does not inhibit S. mutans growth, but exhibits antibacterial activity against E. faecalis, S. aureus, P. aeruginosa and E. coli. After setting, the Bio-C Sealer exhibits an antimicrobial potential comparable to that of the other sealers evaluated in E. faecalis biofilm, but lower than that of EndoFill for S. mutans biofilm.


Resumo O objetivo deste estudo foi avaliar o potencial antibacteriano do novo cimento biocerâmico (Bio-C Sealer, Angelus) contra bactérias comuns em infecções endodônticas primárias e secundárias. Culturas de Enterococcus faecalis, Escherichia coli, Pseudomonas aeruginosa, Staphylococcus aureus e Streptococcus mutans foram expostos a amostras frescas do Bio-C sealer durante 24 h pelo método de difusão em agar (n=5). A atividade antibacteriana de amostras dos cimentos Bio-C Sealer (Angelus), EndoFill (Dentsply-Mallefer), Sealer 26 (Dentsply), AH Plus (Dentsply), Sealapex (Sybron-Endo) e EndoSequence BC Sealer (Brasseler) após a presa também foi investigada em biofilmes de 48 h das bactérias E. faecalis e S. mutans, crescidos em discos com 4 mm de diâmetro e 2 mm de altura. A atividade antibacteriana foi avaliada por contagem das unidades formadoras de colônias (UFC) utilizando o software ImageJ. Os dados foram comparados por ANOVA a um critério seguido pelo pós-teste Holm-Sidak (a=5%). Amostras frescas do Bio-C Sealer exibiram atividade antimicrobiana contra todas as bactérias avaliadas pelo método de difusão em ágar, exceto para S. mutans. A análise da formação de biofilme mostrou que todos os cimentos endodônticos testados apresentaram valores similares de UFC para E. faecalis (p> 0,05), enquanto biofilmes de S. mutans foram mais suscetíveis ao EndoFill em comparação com os demais cimentos (p<0,05). Conclui-se que o cimento Bio-C Sealer fresco exibe atividade antibacteriana para E. faecalis, S. aureus, P. aeruginosa e E. coli, mas não inibe o crescimento de S. mutans. Após a presa, o cimento Bio-C Sealer exibe potencial antimicrobiano similar ao dos demais cimentos avaliados em biofilme de E. faecalis, mas inferior ao do EndoFill para S. mutans.


Asunto(s)
Materiales de Obturación del Conducto Radicular/farmacología , Resinas Epoxi , Staphylococcus aureus , Ensayo de Materiales , Enterococcus faecalis , Silicatos/farmacología , Compuestos de Calcio , Escherichia coli , Antibacterianos/farmacología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA