Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
1.
São Paulo med. j ; 140(3): 474-485, May-June 2022. tab, graf
Artículo en Inglés | LILACS | ID: biblio-1377386

RESUMEN

ABSTRACT BACKGROUND: The thrombin generation test (TGT) has shown promise for investigation of hemorrhagic and thrombotic diseases. However, despite its potential, it still needs standardization. Moreover, few studies have established reference values for TGT parameters. In Brazil, these values have not yet been established. OBJECTIVE: To determine TGT performance and reference intervals for TGT parameters in healthy individuals. DESIGN AND SETTING: Cross-sectional study conducted among participants in the Brazilian Longitudinal Study of Adult Health (Estudo Longitudinal de Saúde do Adulto, ELSA-Brasil). METHODS: The reference sample consisted of 620 healthy individuals. The calibrated automated thrombogram (CAT) method, under low and high tissue factor (TF) conditions, was used to assess thrombin generation. Test performance was analyzed using intra and interassay coefficients of variation (CV) and reference intervals were calculated using the nonparametric method proposed by the International Federation of Clinical Chemistry and the Clinical and Laboratory Standards Institute. RESULTS: The intraassay CV ranged from 1.4% to 2.2% and the interassay CV, 6.8% to 14.7%. The reference intervals for TGT parameters under low and high TF conditions were, respectively: lagtime: 3.0-10.3 and 1.4-3.7 min; endogenous thrombin potential (ETP): 1134.6-2517.9 and 1413.6-2658.0 nM.min; normalized ETP: 0.6-1.3 and 0.7-1.4; peak: 103.2-397.7 and 256.4-479.0 nM; normalized peak: 0.3-1.3 and 0.7-1.2; and time-to-peak: 5.6-16.0 and 3.4-6.7 min. These parameters were categorized relative to sex. Conclusion: TGT performance was adequate and the proposed reference intervals were similar to those of other studies. Our findings may be useful for consolidating the TGT, through contributing to its standardization and validation.


Asunto(s)
Humanos , Trombina , Valores de Referencia , Brasil , Estudios Transversales , Estudios Longitudinales
2.
Biomedical and Environmental Sciences ; (12): 378-384, 2014.
Artículo en Inglés | WPRIM | ID: wpr-270592

RESUMEN

<p><b>OBJECTIVE</b>Calibrated Automated Thrombogram(CAT) is a test to monitor the generation of thrombin. It can be described by four parameters: lag time, peak thrombin, endogenous thrombin potential (ETP) and time to peak (ttPeak). This study aims to determine the normal ranges of CAT parameters in Chinese, and evaluate whether thrombin generation is correlated with the concentration of heparin/low molecular weight heparin.</p><p><b>METHODS</b>Plasma from 120 healthy subjects were collected to determine the normal rangea of CAT parameters in Chinese. Normal plasma pool (NPP, n=25) spiked with different concentrations of heparin or enoxaparin were used to detecte CAT parameters. The overall and age specific normal ranges of CAT parameters were calculated using descriptive statistics method with mean±2SD. The correlation between CAT parameters and age or concentrations of heparin, enoxaparin were analyzed with linear regression model.</p><p><b>RESULTS</b>The normal ranges for lag time, peak thrombin, ETP, ttPeak in the subjects were 3.648±2.465 min, 367.39±151.93 nmol/L, 2277±1030 nmol/L•min and 6.372±4.280 min respectively. Age was linearly correlated with lag time (r=-0.6583, P<0.0001), peak thrombin (r=0.4863, P<0.0001), ETP (r=0.3608, P<0.0014) and ttPeak (r=-0.6313, P<0.0001). The values of ETP/peak ratio were linearly correlated with concentrations of heparin.</p><p><b>CONCLUSION</b>The normal ranges of four CAT parameters for Chinese were determined. CAT parameters are associated with age. ETP/peak ratio could be used to monitor the process of anticoagulation therapy.</p>


Asunto(s)
Adolescente , Adulto , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Adulto Joven , Envejecimiento , Sangre , Pueblo Asiatico , Pruebas de Coagulación Sanguínea , Estándares de Referencia , China , Voluntarios Sanos , Heparina , Valores de Referencia , Trombina
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA