Journal of Pharmaceutical Practice ; (6): 78-81, 2024.
Artículo en Chino | WPRIM | ID: wpr-1006845

RESUMEN

Objective To establish method for simultaneous determination of hesperidin, cinnamaldehyde and eugenol in Chunyang Zhengqi capsules by high performance liquid chromatography. Methods The column was Agilent PorosheⅡ 120 EC-C18 (4.6 mm×150 mm, 4 μm). The mobile phase was acetonitrile-water with gradient elution. The column temperature was 35℃. The flow rate was 1.0 ml/min, and the detection wavelength was 284 nm. Results The methodological verification showed that hesperidin, cinnamaldehyde and eugenol had a good linearity (r≥0.999 9). The precisions were less than 2.0%. The average recovery was between 98.0% and 101.9%. The stability and repeatability of RSD were also less than 3.0%, which met the requirements of method validation. Conclusion The method is simple, stable, reproducible and accurate, which could be used to the quality control of Chunyang Zhengqi capsules.