Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 20
Filtrar
1.
Rev. Urug. med. Interna ; 8(3)dic. 2023.
Artículo en Español | LILACS-Express | LILACS | ID: biblio-1521629

RESUMEN

Introducción: Las hepatopatías son un problema prevalente a nivel mundial. La biopsia hepática ha sido hasta la fecha el gold standard para valorar el grado de fibrosis, sin embargo, con el advenimiento de nuevos métodos no invasivos, costo-efectivos para el sistema sanitario, cada vez recurrimos menos a esta. En nuestro medio se introdujo recientemente la elastografía por onda cizallamiento con imagen biplanar, lo que implica una curva de aprendizaje por parte de los técnicos. Objetivo: Valorar la asociación de los grados de fibrosis hepática determinado por la elastografía por onda de cizallamiento con imagen biplanar (2D-SWE) y el score APRI en pacientes portadores de enfermedad hepática asistidos en el servicio de hepatología del Hospital Pasteur.Médica 2. Metodología: Se incluyeron los pacientes con enfermedad hepática de cualquier etiología, asistidos entre el 01/10/21 al 31/08/22, mayores de 15 años, de ambos sexos y que han sido valorados con elastografía por onda de cizallamiento con imagen biplanar (2D-SWE) y analítica sanguínea realizado por el equipo médico del servicio mencionado en los últimos 6 meses. Resultados: Se incluyeron 158 pacientes. Se encontró mayor prevalencia de enfermedad hepática en mujeres, con predominio de la etiología de enfermedad por hígado graso no alcohólico (EHGNA) e infección por virus de hepatitis C (VHC). Se evidenció asociación positiva entre la elastografía (2D-SWE) y el score APRI para el diagnóstico o exclusión de enfermedad hepática avanzada, sin diferencia estadísticamente significativa entre los dos médicos hepatólogos. Conclusiones: Existe asociación entre la elastografía por SWE y el score APRI para el diagnóstico de enfermedad hepática avanzada en la población general y por etiología.


Introduction: Liver diseases are a prevalent problem worldwide. To date, liver biopsy has been the gold standard for assessing the degree of fibrosis; however, with the advent of new non-invasive, cost-effective methods for the healthcare system, we are resorting to it less and less. Shear wave elastography with biplanar imaging was recently introduced in our setting, which implies a learning curve for technicians. Objective: To assess the association of the degrees of liver fibrosis determined by shear wave elastography with biplanar imaging (2D-SWE) and the APRI score in patients with liver disease treated in the hepatology service of the Pasteur Hospital. Methodology: Patients with liver disease of any etiology, attended between 01/10/21 and 08/31/22, over 15 years of age, of both sexes and who have been evaluated with shear wave elastography with biplanar image were included. (2D-SWE) and blood analysis performed by the medical team of the aforementioned service in the last 6 months. Results: 158 patients were included. A higher prevalence of liver disease was found in women, with a predominance of the etiology of nonalcoholic fatty liver disease (NAFLD) and hepatitis C virus (HCV) infection. A positive association was evident between elastography (2D-SWE) and the APRI score for the diagnosis or exclusion of advanced liver disease, with no statistically significant difference between the two hepatologists. Conclusions: There is an association between SWE elastography and the APRI score for the diagnosis of advanced liver disease in the general population and by etiology.


Introdução: As doenças hepáticas são um problema prevalente em todo o mundo. Até o momento, a biópsia hepática tem sido o padrão ouro para avaliar o grau de fibrose, porém, com o advento de novos métodos não invasivos e de baixo custo para o sistema de saúde, recorremos cada vez menos a ela. A elastografia por onda de cisalhamento com imagem biplanar foi introduzida recentemente em nosso meio, o que implica uma curva de aprendizado para os técnicos. Objetivo: Avaliar a associação dos graus de fibrose hepática determinados pela elastografia por ondas de cisalhamento com imagem biplanar (2D-SWE) e o escore APRI em pacientes com hepatopatia atendidos no serviço de hepatologia do Hospital Pasteur. Metodologia: Foram incluídos pacientes portadores de doença hepática de qualquer etiologia, atendidos entre 10/01/21 e 31/08/22, maiores de 15 anos, de ambos os sexos e que foram avaliados com elastografia por onda de cisalhamento com imagem biplanar. ( 2D-SWE) e análises sanguíneas realizadas pela equipa médica do referido serviço nos últimos 6 meses. Resultados: foram incluídos 158 pacientes. Foi encontrada maior prevalência de doença hepática em mulheres, com predomínio da etiologia da doença hepática gordurosa não alcoólica (DHGNA) e da infecção pelo vírus da hepatite C (HCV). Foi evidente uma associação positiva entre a elastografia (2D-SWE) e o escore APRI para o diagnóstico ou exclusão de doença hepática avançada, sem diferença estatisticamente significativa entre os dois hepatologistas. Conclusões: Existe associação entre a elastografia SWE e o escore APRI para o diagnóstico de doença hepática avançada na população geral e por etiologia.

2.
Odovtos (En linea) ; 25(1)abr. 2023.
Artículo en Inglés | LILACS, SaludCR | ID: biblio-1422189

RESUMEN

To evaluate the shear bond strength (SBS) of self-adhesive resin cement when used with two different computer-aided design (CAD)-computer-aided manufacturing (CAM) materials after various surface treatments. Nanoceramic resin Lava Ultimate (LU) and feldspathic ceramic Vita Mark II (VM) CAD-CAM block samples were prepared with 1.5-mm thickness, and a total of 90 samples were obtained (N=90), with five samples of each block. The samples were divided into the following five groups according to the surface treatments (n=9): group 1, untreated (control); group 2,5% hydrofluoric acid etching; group 3, Er: YAG laser irradiation; group 4, tribochemical silica coating (Cojet); and group 5, air-abrasion with Al2O3. After silane application, resin cement was applied on a transparent matrix (diameter, 3mm; height, 2mm) on the blocks. SBS was determined using a universal testing device at a crosshead speed of 1mm/min. Two-way analysis of variance (ANOVA) and Tukey's post hoc tests were used to analyze the SBS values. LU showed the highest SBS value in group 4. The average SBS values in groups 3 and were found to be lower than that in the control group (p<0.05). When VM was examined, while all surface treatments increased the SBS values significantly, the highest SBS value was observed in group 4 (p<0.05). This study revealed that all surface treatments used negatively affected the bond strength values of self-adhesive resin cement to LU, except for Cojet application. The SBS values of resin cement with VM increased in all surface treatment application groups.


Evaluar la resistencia de unión al corte (SBS) del cemento de resina autoadhesivo cuando se utiliza con dos materiales diferentes de diseño asistido por computadora (CAD) y fabricación asistida por computadora (CAM) después de varios tratamientos superficiales. Se prepararon muestras de bloques CAD-CAM de resina Lava Ultimate (LU) y cerámica feldespática Vita Mark II (VM) con un espesor de 1,5mm, y se obtuvieron un total de 90 muestras (N=90), con cinco muestras de cada bloque. Las muestras se dividieron en los siguientes cinco grupos según los tratamientos superficiales (n=9): grupo 1, sin tratar (control); grupo 2, grabado con ácido fluorhídrico al 5%; grupo 3, irradiación con láser Er: YAG; grupo 4, recubrimiento triboquímico de sílice (Cojet); y grupo 5, aire-abrasión con Al2O3. Después de la aplicación de silano, se aplicó cemento de resina sobre una matriz transparente (diámetro, 3mm; altura, 2mm) sobre los bloques. La SBS se determinó usando un dispositivo de prueba universal a una velocidad de cruceta de 1mm/min. Se utilizaron análisis de varianza bidireccional (ANOVA) y pruebas post hoc de Tukey para analizar los valores de SBS. LU mostró el valor más alto de SBS en el grupo 4. Los valores promedio de SBS en los grupos 3 y fueron más bajos que en el grupo de control (p<0,05). Cuando se examinó VM, mientras que todos los tratamientos superficiales aumentaron significativamente los valores de SBS, el valor más alto de SBS se observó en el grupo 4 (p<0,05). Este estudio reveló que todos los tratamientos de superficie utilizados afectaron negativamente los valores de resistencia de la unión del cemento de resina autoadhesivo a LU, a excepción de la aplicación Cojet. Los valores de SBS del cemento de resina con VM aumentaron en todos los grupos de aplicación de tratamiento de superficie.


Asunto(s)
Diseño Asistido por Computadora , Resinas Compuestas , Cemento Dental
3.
Odovtos (En línea) ; 24(3)dic. 2022.
Artículo en Inglés | LILACS, SaludCR | ID: biblio-1406165

RESUMEN

Abstract This study investigated the shear bond strength (SBS) of a universal adhesive to enamel/dentin; 1) that had undergone radiotherapy (RT) and 2) that were readily restored and had undergone RT. Enamel and dentin surfaces were obtained from 90 intact human molars. They were randomly divided into six groups according to the presence and timing of irradiation (RT0:no radiotherapy/control, RT1:RT before restoration, RT2:RT after restoration groups) and adhesive application modes (etch&rinse/ER, self-etch/SE)(n=15). A universal adhesive and resin composites were applied. The radiotherapy protocol was conducted with 60 Gy. The SBS test was subjected (1mm/min) and failure type analysis was performed. The resin-enamel/dentin interfaces were examined. Data were statistically analyzed. For enamel and dentin, the presence and timing of irradiation did not significantly influence the SBS values (p>0.05). For enamel, significantly higher SBS values were obtained using etch&rinse mode than self-etch mode (p<0.05). The predominant failure was mixed type. Loss of enamel prisms and obliterated irregular dentinal tubules were found for the radiotherapy-treated specimens. Resin tags were clearer in the irradiated enamel treated with ER than SE. Irradiation with different timings did not influence the bond strength to enamel and dentin, negatively. Irrespective of radiotherapy, the etch&rinse mode caused higher bond strength to enamel than self-etch mode.


Resumen Este estudio investigó la fuerza de unión al cizallamiento (SBS) de un adhesivo universal al esmalte/dentina en piezas que se habían sometido a radioterapia (RT). Se obtuvieron superficies de esmalte y dentina de 90 molares humanos intactos. Se dividieron aleatoriamente en seis grupos según la presencia y el momento de la irradiación (RT0: sin radioterapia/control, RT1: RT antes de la restauración, RT2: RT después de la restauración considerando los modos de aplicación del adhesivo (n=15). Se aplicó un adhesivo universal y resinas compuestas. El protocolo de radioterapia se realizó con 60 Gy. Se sometió a la prueba adhesiva (1mm/min) y se realizó análisis del tipo de falla. Se examinaron las interfases resina-esmalte/dentina. Los datos fueron analizados estadísticamente. Para el esmalte y la dentina, la presencia y el momento de la irradiación no influyeron significativamente en los valores adhesivos (p>0,05). Para el esmalte, se obtuvieron valores adhesivos significativamente más altos utilizando el modo de grabado y enjuague que el modo de autograbado (p<0,05). La falla predominante fue de tipo mixto. Se encontró pérdida de prismas de esmalte y túbulos dentinarios irregulares obliterados en las muestras tratadas con radioterapia. La irradiación con diferentes tiempos no influyó negativamente en la fuerza de unión al esmalte ni a la dentina. Independientemente de la radioterapia, el modo de grabado ácido y enjuague provocó una mayor fuerza de adhesión al esmalte que el modo de autograbado.


Asunto(s)
Humanos , Radioterapia/efectos adversos , Turquía , Cemento Dental/efectos de los fármacos , Neoplasias de Cabeza y Cuello
4.
Odovtos (En línea) ; 23(2)ago. 2021.
Artículo en Inglés | LILACS, SaludCR | ID: biblio-1386542

RESUMEN

ABSTRACT: Purpose: The aim of this study is to compare the shear bond strength of three high-viscosity bulk-fill composite resins applied as single layers of 4mm thickness and of one microhybrid composite resin applied incrementally with a thickness of 2mm on dentin surfaces prepared with different surface preparation methods. Materials and Methods: A total of 132 caries-free human molars whose dentines had been exposed were used. Three groups, each containing 44 teeth, were formed. The acid group was etched with 32% phosphoric acid; laser group was etched with Er, Cr; YSGG laser and the control group was prepared with silicon carbid paper. Following the application of bonding agent, composite resin materials were applied on teeth using teflon moulds of 4x4mm. The samples were then subjected to shear bond strength tests. Two-way variance analysis and Tukey HSD multiple comparison test were applied on collected data. Results: There was a significant difference between surface treatment methods used regarding shear bond strength (P0.05). Conclusions: Laser etching of the dentin tissues is not as effective as acid etching. Bulk-fill composites had similar effects compared with conventional composite resins with regard to bonding strength. More in vitro studies supported with clinical data are required to investigate the performance of bulk-fill composites and laser.


RESUMEN: Propósito: El objetivo de este estudio es comparar la resistencia adhesiva al cizallamiento de tres resinas compuestas de relleno de alta viscosidad aplicadas como capas individuales de 4 mm de espesor y de una resina compuesta microhíbrida aplicada de forma incremental con un espesor de 2mm en superficies de dentina preparadas con diferentes métodos de preparación de la superficie. Materiales y métodos: Se utilizaron un total de 132 molares humanos sin caries cuyas dentinas habían sido expuestas. Se formaron tres grupos, cada uno con 44 dientes. El grupo ácido se grabó con ácido fosfórico al 32%; el grupo láser se grabó con Er, Cr; el láser YSGG y el grupo de control se preparó con papel de carburo de silicio. Después de la aplicación del agente adhesivo, se aplicaron materiales de resina compuesta en los dientes utilizando moldes de teflón de 4x4mm. A continuación, las muestras se sometieron a pruebas de resistencia adhesiva al cizallamiento. Se aplicó el análisis de varianza bidireccional y la prueba de comparación múltiple Tukey HSD a los datos recogidos. Resultados: Hubo una diferencia significativa entre los métodos de tratamiento de superficie utilizados en cuanto a la resistencia adhesiva al cizallamiento (P0,05). Conclusiones: El grabado láser de los tejidos de la dentina no es tan eficaz como el grabado al ácido. Las resinas de relleno bulk-fill tuvieron efectos similares en comparación con las resinas compuestas convencionales en lo que respecta a la rsistencia adhesiva. Se necesitan más estudios in vitro apoyados con datos clínicos para investigar el rendimiento de los composites de relleno y el láser.


Asunto(s)
Resinas Compuestas/análisis , Cementos Dentales , Turquía
5.
Odovtos (En línea) ; 22(3)dic. 2020.
Artículo en Inglés | LILACS, SaludCR | ID: biblio-1386492

RESUMEN

Abstract Purpose: The purpose of the present research was to evaluate the effectiveness of self-adhesive composites in amalgam repair as time-saving alternatives to universal bonding-universal composite materials, with or without the usage of Alloy Primer in terms of shear bond strength. Materials and Methods: Forty- two disc-shaped amalgam samples were prepared by condensing into 6×2 mm holes in acrylic resin blocks, sandblasted with 50 μm Al2O3 and randomly divided into 6 groups according to repair material [Constic (Group C), Fusio Liquid Dentin (Group FLD), Universal bonding+Universal composite (Group Control), Alloy Primer+Constic (Group APC), Alloy Primer+Fusio Liquid Dentin (Group APFLD), Alloy Primer+Universal bonding+Universal composite (Group APControl)]. After shear bond strength test, the fracture modes were determined under a digital microscope. Statistical analysis was performed using one-way analysis of variance and Tukey's post hoc test. Results: The highest shear bond strength values were obtained for Fusio Liquid Dentin, among the three repair materials when Alloy Primer was not applied (p<0.05). Usage of Alloy Primer increased shear bond strength values of the investigated repair materials to amalgam, except Fusio Liquid Dentin. Conclusion: Within the limitations of the present research, it can be concluded that; the investigated self-adhesive composite materials could be time-saving alternatives to the Universal bonding+Universal composite for the purpose of amalgam repair, in terms of shear bond strength. The clinicians could prefer Fusio Liquid Dentin self-adhesive composite material without Alloy Primer application for the purpose of amalgam repair in non-cooperative patients.


Resumen Propósito: El propósito de la presente investigación fue evaluar la efectividad de las resinas compuestas autoadhesivas en la reparación de amalgamas como alternativas que ahorran tiempo con respecto a las resinas compuestas universales de adhesión universal, con o sin el uso de Alloy Primer en términos de resistencia al cizallamiento. Materiales y métodos: Se prepararon 42 muestras de amalgama en forma de disco condensándolas en orificios de 6×2 mm en bloques de resina acrílica, arenadas con 50 μm de Al2O3 y divididas al azar en 6 grupos según el material de reparación [Constic (Grupo C), Fusio Liquid Dentin (Grupo FLD), Adhesivo universal+Resina universal (Grupo Control), Imprimación de aleación+Constic (Grupo APC), Imprimación de aleación+Fusio Liquid Dentin (Grupo APFLD), Imprimación de aleación+Adhesivo universal+Resina universal (Grupo APControl)]. Después de la prueba de resistencia al cizallamiento, los modos de fractura se determinaron bajo un microscopio digital. El análisis estadístico se realizó mediante análisis de varianza unidireccional y la prueba post hoc de Tukey. Resultados: Se obtuvieron los valores de resistencia al cizallamiento más altos para Fusio Liquid Dentin, entre los tres materiales de reparación cuando no se aplicó Alloy Primer (p<0.05). El uso de Alloy Primer aumentó los valores de resistencia al cizallamiento de los materiales de reparación investigados para la amalgama, excepto Fusio Liquid Dentin. Conclusión: Dentro de las limitaciones de la presente investigación, se puede concluir que; los materiales compuestos autoadhesivos investigados podrían ser alternativas que ahorran tiempo con respecto al adhesivo universal+resina universal con el fin de reparar las amalgamas, en términos de resistencia a la cizalladura. Los clínicos podrían preferir el material compuesto autoadhesivo Fusio Liquid Dentin sin la aplicación Alloy Primer con el fin de reparar amalgamas en pacientes poco cooperadores.


Asunto(s)
Cementos de Resina , Amalgama Dental , Resistencia al Corte
6.
Int. j. odontostomatol. (Print) ; 14(4): 658-663, dic. 2020. tab
Artículo en Inglés | LILACS | ID: biblio-1134554

RESUMEN

ABSTRACT: Orthodontic accessories bonding in tooth enamel has been a critical step since the introduction of direct bonding techniques due to the importance of bracket stability. The aim of this study was to evaluate adhesion strength of different adhesive systems used for bracket bonding on dental surface. The present in vitro study was made from the analysis of shear strength of steel and ceramic brackets bonding with six different types of orthodontic adhesives. The brackets were bonded to 120 human extracted first premolar teeth with Orthocem®, Orthocem® + Ambar Universal® primer, Orthobond Plus®, Biofix®, Transbond XT®, Ortholink VLC®. Shear strength tests were performed on a universal testing machine EZ-Test-Shimadzu® and the data were analyzed using ANOVA test with Post-Hoc Bonferroni and 95 % statistical significance (p <0.05). Transbond XT® and Ortholink VLC® resin values showed greater shear resistance for steel brackets bonding and Transbond XT® and Orthobond Plus® adhesives showed better adhesion results for ceramic brackets bonding.


RESUMEN: La unión de accesorios de ortodoncia en el esmalte dental ha sido un paso crítico desde la introducción de las técnicas de unión directa debido a la importancia de la estabilidad del soporte. El objetivo de este estudio fue evaluar la fuerza de adhesión de diferentes sistemas adhesivos utilizados para la unión de brackets en la superficie dental. El presente estudio in vitro se realizó a partir del análisis de la resistencia al corte de brackets de acero y de cerámica unidos con seis tipos diferentes de adhesivos de ortodoncia. Los brackets se unieron a 120 primeros premolares extraídos con los adhesivos Orthocem®, Orthocem® + Ambar Universal® primer, Orthobond Plus®, Biofix®, Transbond XT®, Ortholink VLC®. Las pruebas de resistencia al corte se realizaron en una máquina de prueba universal EZ-Test-Shimadzu® y los datos se analizaron usando la prueba ANOVA con Bonferroni Post-Hoc y 95 % de significación estadística (p <0,05). Los valores de resina Transbond XT® y Ortholink VLC® mostraron una mayor resistencia al corte para la unión de brackets de acero y los adhesivos Transbond XT® y Orthobond Plus® mostraron mejores resultados de adhesión para la unión de brackets cerámicos.


Asunto(s)
Humanos , Recubrimiento Dental Adhesivo/métodos , Soportes Ortodóncicos , Cementos Dentales , Ortodoncia , Acero Inoxidable , Ensayo de Materiales , Cerámica , Cementos de Resina , Resistencia al Corte
7.
Odovtos (En línea) ; 22(1): 93-101, ene.-abr. 2020. tab
Artículo en Inglés | LILACS, BBO | ID: biblio-1091509

RESUMEN

ABSTRACT The aim of this study was to evaluate the shear bond strength (SBS) of two universal adhesives (Universal Single Bond and All Bond Universal) and a two- step self-etch adhesive system (Clearfil SE Bond) to dentine at various temperatures. Materials and Methods: One hundred and twenty dentin specimens were divided randomly to 12 groups, according to adhesive systems (Universal Single Bond and All Bond Universal, Clearfil SE Bond) and temperature ( 4ºC, 20 ºC, 36ºC, 55ºC) used. Dentin specimens were prepared (n :10, adhesives were applied, and composite cylinders were polymerized. Statistical analysis of the SBS data was performed using Two-way analysis of variance (ANOVA) and Tukey's Honestly Significant Differences post-hoc test. Results: The Clearfil SE Bond was shown to have higher SBS than the universal adhesives at all temperatures; however, there was no statistically significant difference (P>0.05). In both groups, the lowest SBS values were observed in the samples at 4°C while the highest SBS values were observed in the samples at 55°C. In this case, there was a statistically significant difference (P<0.05). Conclusions: The results suggest that the effectiveness of an adhesive may increase if it is preheated at 36°C or above before use instead of being used immediately after removal from the refrigerator or at room temperature.


RESUMEN El objetivo de este estudio fue evaluar la resistencia al cizallamiento (SBS) de dos adhesivos universales (Universal Single Bond y All Bond Universal) y un sistema de adhesivo de autograbado de dos pasos (Clearfil SE Bond) a la dentina en diferentes temperaturas. Materiales y métodos: Ciento veinte muestras de dentina se dividieron aleatoriamente en 12 grupos, de acuerdo con los sistemas adhesivos (Universal Single Bond y All Bond Universal, Clearfil SE Bond) y la temperatura (4ºC, 20ºC, 36ºC, 55ºC) utilizada. Se prepararon muestras de dentina (n: 10), se aplicaron los sistemas adhesivos y se polimerizaron los cilindros compuestos. El análisis estadístico de los datos de SBS se realizó utilizando el análisis de varianza de dos vías (ANOVA) y la prueba post-hoc de Tukey's. Resultados: El Clearfil SE Bond mostró tener un SBS más alto que los adhesivos universales en todas las temperaturas evaluadas; sin embargo, no hubo una diferencia estadísticamente significativa (P> 0.05). En todos los grupos, los valores más bajos de SBS se observaron en las muestras a 4°C, mientras que los valores de SBS más altos fueron obtenidos en las muestras a 55°C (P <0.05). Conclusiones: Los resultados sugieren que la efectividad de un adhesivo puede aumentar si se precalienta a 36°C o superior, antes de usarlo inmediatamente después de sacarlo del refrigerador o a temperatura ambiente.


Asunto(s)
Recubrimientos Dentinarios , Cementos Dentales , Resistencia al Corte , Dentina
8.
Odovtos (En línea) ; 21(3): 89-99, Sep.-Dec. 2019. tab, graf
Artículo en Inglés | LILACS, BBO | ID: biblio-1091495

RESUMEN

ABSTRACT Purpose: The purpose of this study is to evaluate the shear bond strength (SBS) of orthodontic brackets bonded to three different bulk fill composites which were previously aged. Materials and Methods: Three bulk fill composite materials were included in this study (Filtek Bulk Fill, Tetric N-Ceram bulk fill, SureFil SDR bulk fill). Each material group contained 12 samples (n=12); a total of 36 samples were bonded in the same way with maxillary premolar brackets (CB; Avex Mx, OPAL orth.). The same type brackets were bonded on each restored surface made with bulk fill composites. The SBS was examined after storing the specimens for 24 h at 37 ºC indistilled water, followed by thermal ageing (500 cycles between 5 ºC and 55 ºC). Data were analyzed statistically. The numeric data were analyzed using analysis of variance (ANOVA) with Tukey HSD post-hoc tests at α=.05. Results: There were no significant differences among the composite groups (p>0.001). However, SBS values for control group were significantly greater than shear bond strenght values for composite groups (p<0.001). Conclusion: Bond strength of orthodontic brackets on bulk fill composite surfaces was not found adequate. Therefore, this situation leads to bonding failure during orthodontic treatment. The presence of bulk fill composites on the surface to be bonded during orthodontic treatment requires an additional armamentarium.


RESUMEN Propósito: El propósito de este estudio es evaluar la resistencia al cizallamiento (SBS) de brackets de ortodonci unidos a tres compuestos de relleno masivo diferentes que fueron envejecidos previamente. Metodología: Se incluyeron tres materiales compuestos de relleno a granel en este estudio (Filtek Bulk Fill, Tetric N-Ceram bulk fill, SureFil SDR bulk fill). Cada grupo de material contenía 12 muestras (n = 12); un total de 36 muestras se unieron de la misma manera con soportes premolares maxilares (CB; Avex Mx, OPAL orth.). Los mismos soportes de tipo se unieron en cada superficie restaurada hecha con compuestos de relleno masivo. El SBS se examinó después de almacenar las muestras durante 24 horas a 37 ºC de agua no destilada, seguido de un envejecimiento térmico (500 ciclos entre 5 ºC y 55 ºC). Los datos fueron analizados estadísticamente. Los datos numéricos se analizaron mediante el análisis de varianza (ANOVA) con pruebas post hoc de Tukey HSD en α=.05. Resultados: No hubo diferencias significativas entre los grupos compuestos (p> 0,001). Sin embargo, los valores de SBS para el grupo de control fueron significativamente mayores que los valores de resistencia al cizallamiento para los grupos compuestos (p <0.001). Conclusión: La resistencia de de brackets de ortodonci en superficies compuestas de relleno en masa no se encontró adecuada. Por lo tanto, esta situación conduce a una falla de adhesión durante el tratamiento de ortodoncia. La presencia de compuestos de relleno a granel en la superficie a unir durante el tratamiento de ortodoncia requiere un arsenal adicional.


Asunto(s)
Soportes Ortodóncicos , Resistencia al Corte , Materiales Dentales/análisis
9.
Int. j. odontostomatol. (Print) ; 12(4): 407-411, dic. 2018. tab
Artículo en Inglés | LILACS | ID: biblio-975765

RESUMEN

ABSTRACT: Orthodontic cements have been used to enhance retention between the band and the crown, however, unfavorable properties found in many of these cements may contribute to cement failure between band and crown's surface and leading to unsuccessful application of orthodontic forces. The aim of this study was to evaluate the shear strength of the Orthobite composite (FGM) using the Single Bond adhesive system (3M). The sample consisted of 30 bovine incisors divided in 2 groups (n=15). All teeth were submitted to prophylaxes with pumice stone and etching with phosphoric acid. In Group I the Orthobite was used conventionally. Group II was similar to Group I, however, the Single Bond adhesive system was applied after conditioning. The samples were stored in distilled water in incubator at 37 ºC for 24 h and submitted to the shear strength test at a speed of 0.5 mm/minute speed. Data were submitted to the Student T test (5 %). The results (MPa) showed no statistically significant differences between the groups, regardless of surface treatment. Thus, all groups exhibited adequate adhesive bond strength for clinical use.


RESUMEN: Los cementos ortodónticos se han utilizado para aumentar la retención entre la banda y la corona, sin embargo, las propiedades desfavorables encontradas en muchos de estos cementos pueden contribuir a la falla del cemento entre la superficie de la banda y la corona y llevar a la aplicación incorrecta de fuerzas de ortodoncia. El objetivo de este trabajo fue evaluar la resistencia al cizallamiento del compuesto Orthobite (FGM) utilizando el sistema adhesivo Single Bond (3M). La muestra consistió de 30 incisivos bovinos divididos en dos grupos (n = 15). Todos los dientes recibieron profilaxis con piedra pómez y acondicionamiento del esmalte con ácido fosfórico. En el Grupo I, se utilizó Orthobite de manera convencional. El Grupo II fue similar al I, pero se aplicó el sistema adhesivo Single Bond, después de acondicionamiento. Los cuerpos de prueba fueron almacenados en agua destilada en estufa a 37 ºC por 24 h y sometidos al ensayo de resistencia al cizallamiento, con velocidad de 0,5 mm por minuto. Los datos fueron sometidos a la prueba de T Student (5 %). Los resultados (en MPa) no mostraron diferencias estadísticamente significativas entre los grupos, independientemente del tratamiento de la superficie. De esta forma, todos los grupos presentaron resistencia adhesiva adecuada para uso clínico.


Asunto(s)
Animales , Bovinos , Aparatos Ortodóncicos , Recubrimiento Dental Adhesivo , Cementos de Ionómero Vítreo , Resistencia a la Tracción , Resinas Acrílicas , Soportes Ortodóncicos , Estadísticas no Paramétricas , Resistencia al Corte
10.
Odovtos (En línea) ; 20(3): 71-79, Sep.-Dec. 2018. tab
Artículo en Español | LILACS, BBO | ID: biblio-1091461

RESUMEN

RESUMEN El objetivo del presente estudio fue evaluar los efectos de la aplicación de un antioxidante sobre las fuerzas de unión (SBS) de brackets de ortodoncia posterior al blanqueamiento con peróxido de hidrógeno (HP). Metodología: Cincuenta premolares recién extraídos se dividieron aleatoriamente en tres grupos. El Grupo 1 se trató con 40% de HP (n=20), el grupo 2 con 40% de HP y se activó con láser de Nd: YAG (n=20) y un grupo de control (Grupo 3) no recibió tratamiento (n=10). Después del blanqueamiento, los Grupos 1 y 2 se dividieron en dos subgrupos (Grupo 1a, Grupo 1b, Grupo 2a y Grupo 2b). Las muestras en los subgrupos 1a y 2a (n=10) no recibieron ninguna aplicación del antioxidante. Se aplicó una solución de ascorbato de sodio al 10% a las muestras en los Grupos 1b y 2b (n=10). Luego, los brackets se adherieron a las superficies de esmalte de todos los grupos experimentales. Las muestras se sometieron a pruebas de SBS y los datos analizados estadisticamente. Resultados: La fuerza de unión de los grupos 1 y 2 fue significativamente más baja que el grupo de control (p <0.001); sin embargo, no se observaron diferencias estadísticamente significativas en SBS entre los grupos 1 y 2 (p>0.001). Las muestras tratadas con antioxidantes de los grupos 1b y 2b fueron significativamente mayores que las de los grupos 1a y 2a (p <0,001). Conclusion: La aplicación de 40% HP tuvo un efecto negativo en la resistencia de unión de los brackets. El uso de antioxidante durante 15 minutos mejoró significativamente la SBS.


ABSTRACT Purpose: The purpose of this study was to evaluate the effects of the application of antioxidant on the shear bond strengths (SBS) of orthodontic brackets bonded to human enamel after extra-coronal bleaching with hydrogen peroxide (HP). Materials and methods: Fifty freshly extracted premolars were randomly divided into three groups. One group (Group 1) was bleached with 40% HP (n=20), another group (Group 2) was bleached with 40% HP and activated with an Nd: YAG laser (n=20), and a control group (Group 3) received no treatment (n=10). After the bleaching procedure, Groups 1 and 2 were further divided into two subgroups (Group 1a, Group 1b, Group 2a, and Group 2b). Specimens in Groups 1a and 2a (n=10) received no antioxidant application. A 10% sodium ascorbate solution was applied to specimens in Groups 1b and 2b (n=10). The brackets were then bonded with light-cure adhesive paste to the enamel surfaces of all experimental groups. Specimens were subjected to SBS tests for debonding. Results: The SBS of brackets bonded in Groups 1 and 2 were significantly lower than those of brackets bonded to the control group (p<0.001); however, no statistically significant differences in SBS were noted in Groups 1 and 2 (p>0.001). The antioxidant-treated SBS of brackets in Groups 1b and 2b were significantly higher than those of Groups 1a and 2a (p<0.001). Conclusions: The application of 40% HP had a negative effect on the bond strength. The use of antioxidant for 15 min resulted in the reversal of failed bond strength.


Asunto(s)
Blanqueamiento de Dientes/métodos , Soportes Ortodóncicos , Resistencia al Corte/efectos de los fármacos , Peróxido de Hidrógeno/efectos adversos , Terapia por Láser
11.
Rev. ADM ; 74(5): 224-230, sept.-oct. 2017. ilus, tab
Artículo en Español | LILACS | ID: biblio-973041

RESUMEN

Es un estudio de investigación cuantitativo donde el objetivo fue determinar la resistencia al cizallamiento utilizando adhesivo de grabado total y autograbante, introduciendo la desproteinización con NaOCl al 5.25 por ciento en dentina y comparar sus valores de resistencia. El estudio se realizó en 31 molares seccionados mesiodistalmente y vestibulo lingual, obteniendo 124 especímenes, se suspendieron en acrílico, pulieron y colocaron en refrigeración a 36 oC durante 48 horas; fueron clasificados en grupos A: Prime & Bond NT, B: NaOCl + Prime & Bond NT, C: NaOCl + Xeno® IV y D: Xeno® IV; se fotoactivó un cilindro de resina compuesta ESTHET-X HD de Dentsply, se mantuvo por 24 horas en horno Felisa con 100 por ciento de humedad, finalmente se probaron en la máquina INSTRON a una velocidad de 1 m/min. Se obtuvieron los siguientes promedios, grupos: A: 6.26, B: 7.71, C: 12.03 y D: 15.06 MPa. Para el grupo C y D que pertenecen al grupo autograbante, fueron estadísticamente significativos para el sustrato dentinal. NaOCl no mostró significancia entre los grupos.


It is a quantitative research where the objective was to determinethe shear strength using total and self etching adhesive, introducing de proteinization with 5.25% NaOCl in dentin and comparing its resistance values. The study was performed on 31 mesiodistally andbuccololingual sectioned molars, obtaining 124 specimens, suspended in acrylic, polished and placed in refrigeration at 36 oC for 48 hours;Were classified into groups A: Prime & Bond NT, B: NaOCl + Prime& Bond NT, C: NaOCl + Xeno® IV and D: Xeno® IV; A: DentsplyESTHET-X HD composite resin cylinder was photoactivated, kept for24 hours in a Felisa oven with 100% humidity, finally tested on theINSTRON machine at a speed of 1 mm/min. The following averageswere obtained, groups: A: 6.26, B: 7.71, C: 12.03 and D: 15.06 MPa.For group C and D belonging to the self-etching group, they werestatistically significant for the dentinal substrate. NaOCl, showed nosignificance between the groups.


Asunto(s)
Humanos , Resinas Compuestas/química , Resistencia al Corte , Recubrimientos Dentinarios , Grabado Ácido Dental/instrumentación , Hipoclorito de Sodio , Dentina , Ensayo de Materiales , Interpretación Estadística de Datos , Estudios de Evaluación como Asunto , Análisis de Varianza , México
12.
Int. j. morphol ; 35(3): 1140-1146, Sept. 2017. ilus
Artículo en Inglés | LILACS | ID: biblio-893106

RESUMEN

This study evaluated the effect of chlorhexidine dentin treatment on shear bond strength (SBS) of adhesive systems after different storages. The work included 144 third molars that had their dentin exposed and were divided in 6 groups: G1 (ASB+CHX: Adper Scotchbond 1XT + chlorhexidine 2 % prior Primer); G2(ASB); G3 (APP+CHX: Adper Prompt L-Pop + CHX); G4(APP); G5 (SBU+CHX: Single Bond Universal + CHX); and G6(SBU). Resin build-up was performed and teeth were subdivided regarding storage times (n=8): 72 h, 3 and 6 months. Next, SBS test was performed. At 72 hours, all equivalent groups (same adhesive system, different dentin treatment) showed no significant difference in SBS (P.05). Self-etch adhesive groups (with or without CHX) presented lower SBS compared to other systems (P.05). After 3 and 6 months, all CHX-treated groups presented significantly higher SBS compared to equivalent non-treated groups (P.05). For both storage times, Single Bond Universal presented the highest SBS values within the same dentin treatment (P.05), while Adper Scotchbond and Adper Prompt-L-Pop were not significantly different among them, also within the same dentin treatments [3 months (with CHX: P=.966; without: P=.958) and 6 months (with CHX: P =.887; without: P=.990)]. CHX Dentin disinfection is indicated for all classes of adhesives studied.


Este estudio evaluó el efecto del tratamiento de la dentina con clorhexidina sobre la resistencia al cizallamiento (SBS) de sistemas adhesivos después de diferentes almacenamientos. Se removió el esmalte oclusal a 144 terceros molares y se dejó su dentina media expuesta, posteriormente se dividieron al azar en 6 grupos: G1 (ASB + CHX: Adper Scotchbond 1XT + clorhexidina 2 % antes del Primer); G2 (ASB); G3 (APP + CHX: L-Pop + CHX de Adper); G4 (APP); G5 (SBU + CHX: Single Bond Universal + CHX); y G6 (SBU). Se realizó la aplicación de la resina compuesta y se subdividieron los grupos con respecto a los tiempos de almacenamiento (n = 8): 72h, 3 y 6 meses. A continuación, se realizó la prueba SBS. A las 72 horas, todos los grupos equivalentes (el mismo sistema adhesivo, diferentes tratamientos de dentina) no mostraron diferencias significativas en los valores de SBS (P.05). Los grupos de adhesivo de auto-grabado (con o sin CHX) presentaron valores de SBS más bajos en comparación con otros sistemas (P.05). Después de 3 y 6 meses, todos los grupos tratados con CHX presentaron valores de SBS significativamente mayores en comparación con los grupos no tratados equivalentes (P.05). Para ambos tiempos de almacenamiento, Single Bond Universal presentó los valores de SBS más altos dentro del mismo tratamiento dentinario (P.05), mientras que el Adper Scotchbond y el Adper Prompt-L-Pop no fueron significativamente diferentes entre ellos, también dentro de los mismos tratamientos dentinarios 3 meses (con CHX: P = .966, sin: P = .958) y 6 meses (con CHX: P = .887; sin: P = .990). La desinfección de la dentina con CHX está indicada para todas las clases de adhesivos estudiados.


Asunto(s)
Humanos , Antiinfecciosos Locales/farmacología , Clorhexidina/farmacología , Cementos Dentales/química , Dentina , Materiales Dentales/química , Ensayo de Materiales , Resistencia al Corte , Resistencia a la Tracción , Factores de Tiempo
13.
Rev. estomatol. Hered ; 27(2): 81-87, abr. 2017. ilus, tab
Artículo en Español | LILACS | ID: biblio-991175

RESUMEN

Objetivos: Evaluar el efecto del peróxido de hidrógeno al 40% sobre la fuerza de resistencia al cizallamiento de brackets metálicos cementados en distintos intervalos de tiempo. Materiales y métodos: Sesenta premolares superiores fueron aleatoriamente asignados a 4 grupos de 15 unidades cada uno. En el grupo I los brackets fueron cementados 1 hora después de someter los dientes al aclaramiento dental, en el grupo II los brackets fueron cementados luego de 7 días y en el grupo III luego de 14 días, un grupo sirvió de control donde no se realizó el aclaramiento dental. Se midió la fuerza de resistente al cizallamiento de los brackets por medio de una máquina de prueba universal de resistencia y se empleó el índice IRA para valorar la interfase donde se produjo la falla. Resultados: Los resultados muestran que el aclaramiento dental reduce significativamente la fuerza de adhesión de los brackets (p<0,05). La fuerza necesaria para descementar los brackets en el grupo III (17,95 MPa) fue similar a la que se requirió en el grupo control (18,03 MPa), los grupos I y II presentaron valores bajos (13,37 MPa y 13,58 MPa respectivamente). Se encontraron diferencias significativas en los valores IRA (p<0,05). Conclusiones: El uso de peróxido de hidrógeno al 40% como agente aclarador reduce las fuerzas de adhesión de los brackets cuando son cementados antes de 14 días del procedimiento de aclaramiento dental.


Objectives: To evaluate the effect of a 40% hydrogen peroxide bleaching agent upon the shear bond strength of metallic brackets, bonded at different time intervals. Materials and Methods: 60 upper premolars were randomly assigned to 4 groups, with 15 in each group. In group I the brackets were bonded 1 hour after the teeth were subjected to bleaching. In group II the brackets were bonded after 7 days, and in group III after 14 days. One group served as a control and did not receive the bleaching treatment. The shear bond strength was measured by a universal testing machine and the Adhesive Remnant Index (ARI) rate was used to assess the interface where the fault was produced. Results: The results show that bleaching significantly reduces the adhesive strength of the brackets (p<0.05). The strength necessary to debond the brackets in group III (17.95 ± 1.76 MPa) was similar to that which was required in the control group (18.03 ± 3.08 MPa). Groups I and II presented low values (13.37 ± 2.09 MPa and13.58 ±1.75 MPa respectively). Significant differences were found in the ARI scores (p<0.05).Conclusions:The use of40% hydrogen peroxide as a bleaching agent reduces the adhesive strength of the brackets when they were bonded before 14 days of bleaching procedure.

14.
Rev. Fac. Odontol. Univ. Antioq ; 27(2): 322-341, Jan.-July 2016. tab, graf
Artículo en Inglés | LILACS | ID: biblio-957217

RESUMEN

ABSTRACT Introduction: currently, talking about highly resistant aesthetic dental restorations implies talking of yttrium-stabilized zirconium dioxide (Y-TZP) ceramic systems, which have become important due to their good mechanical and physical properties and high biocompatibility. One of the main complications of such restorations nowadays is ceramic coating delamination. It has been shown that the interface of both materials is the origin of failure because of poor bonding strength, mainly due to excessive internal tension in the coating material caused by a difference in the thermal expansion coefficients of both materials. Methods: 15 zirconium blocks were randomly sorted out into 3 groups: one control group and two groups were the surface of bonding to the ceramic coating was modified by grinding with rounded diagonal and squared burs respectively. Once the samples were sintered, the ceramic coating was applied and shear bond strength tests were performed. A one-way analysis of variance (ANOVA) was conducted. The Tukey′s range test was used to compare the difference in results among groups. Results: the results in this study were very heterogeneous. The average shear bond strength values were 20.2 MPa ± 6.8 MPa for Group A; 5.87 MPa ± 4.87 Mpa for Group B, and 3.69 ± 2.68 MPa for Group C. Conclusions: it is not necessary to prepare the zirconium surface with mechanical grinding in order to improve shear bond strength in ceramic coatings.


RESUMEN Introducción: hoy en día, hablar de restauraciones odontológicas estéticas de alta resistencia implica hablar de sistemas cerámicos de dióxido de zirconio estabilizados con itrio (Y-TZP), los cuales han cobrado importancia por sus buenas propiedades mecánicas y físicas y por su buena biocompatibilidad. Una de las principales complicaciones que están sufriendo hoy en día dichas restauraciones es la delaminación de la porcelana de recubrimiento. Se ha determinado que la interface de los dos materiales es el origen de la falla a causa de una deficiente resistencia de unión, debido principalmente a una tensión interna excesiva en el material de recubrimiento, por una diferencia entre los coeficientes de expansión térmica de ambos materiales. Métodos: se tomaron 15 bloques de zirconio y fueron divididos aleatoriamente en 3 grupos: un grupo control y los otros dos con modificación en la superficie de unión a la cerámica de recubrimiento por medio de una rallado con fresa redonda de forma diagonal y cuadrangular respectivamente. Una vez fueron zinterizados, se puso la cerámica de recubrimiento y finalmente se les realizó pruebas de cizallamiento. Se llevó a cabo un análisis de varianza de una vía (ANOVA). Se usó la prueba de Tukey múltiple para comparar la diferencia de los resultados entre los grupos. Resultados: los resultados arrojados en el estudio fueron muy heterogéneos. Los valores promedio de resistencia de unión al cizallamiento arrojados fueron 20,2 MPa ± 6,8 MPa para el grupo A; 5,87 MPa ± 4,87 Mpa para el grupo B, y 3,69 ± 2,68 MPa para el grupo C. Conclusiones: no es necesario preparar la superficie de zirconio con trabas mecánicas por medio de un fresado para mejorar la resistencia de unión con la cerámica de recubrimiento.


Asunto(s)
Estética Dental , Circonio , Cerámica
15.
Artículo en Español | LILACS | ID: lil-734831

RESUMEN

El presente estudio evaluó el grado de sellado marginal y resistencia adhesiva de restauraciones de resinas compuestas confeccionadas con un sistema adhesivo de grabado y lavado en dentición primaria y definitiva. Para realizar ambos test se utilizaron 20 piezas primarias y 20 piezas definitivas. En resistencia al cizallamiento, los dientes fueron seccionados longitudinalmente y se les adhirió un cilindro de resina compuesta, utilizando la técnica adhesiva de grabado y lavado para ambas denticiones. Posteriormente, fueron testeados en una máquina de ensayos universales Tinius Olsen, aplicando una fuerza de cizallamiento de 200 kg y a una velocidad de cabezal de 0,2 cm/min. Para el test de sellado marginal, se les realizó una preparación cavitaria clase V, por vestibular/palatino estandarizada. Luego se les confeccionaron restauraciones de resina compuesta con la técnica de grabado y lavado, y se sometieron al termociclado con azul de metileno al 2%; después fueron cortados y observados al microscopio óptico estereoscópico con aumento de lupa, para medir el porcentaje de microfiltración obtenido. El valor promedio de la resistencia adhesiva al cizallamiento para dentición primaria fue de 8,49 Mpa, y de 9,52 Mpa para dentición definitiva, no encontrándose diferencias estadísticamente significativas entre los grupos en estudio. En la investigación sobre el grado de sellado marginal se evaluó el porcentaje de microfiltración y tampoco se encontraron diferencias estadísticamente significativas, lo que señalaría que ambos tejidos son igualmente susceptibles de ser tratados adhesivamente mediante la técnica de hibridación.


The present study evaluated the degree of marginal seal and adhesive resistance of composite resin restorations prepared with an etch and rinse adhesive system in primary and definitive dentition. To perform both tests, 20 primary pieces and 20 permanent pieces were used. In the shear strength resistance, the teeth were sectioned longitudinally and were adhered to composite resin cylinder, using the etch and rinse technique for both dentitions. They were then tested on a Tinius Olsen universal testing machine, applying a shear force of 200 kg and a head speed of 0.2 cm/min. For the margin seal test, a class V cavity preparation of standardised vestibular/palatine was made. The composite resin restorations were made with the etch and rinse technique and were subjected to thermocycling with 2% methylene blue. Later, they were cut and observed using a stereoscopic optical microscope with loop magnification to measure the percentage of microfiltration obtained. The mean value of the adhesive resistance to shearing for primary dentition was 8.49 Mpa, and 9.52 Mpa for permanent teeth, with no statistically significant differences being found between the groups studied. In the test on the degree of margin seal the percentage microfiltration was measured, with no statistically significant differences being found either. The results showed that both tissues are equally susceptible to being treated adhesively using the hybrid technique.


Asunto(s)
Humanos , Diente Primario , Adhesivos , Resinas Compuestas , Resistencia al Corte , Filtración Dental , Análisis del Estrés Dental , Ciencia de los Materiales
16.
Int. j. odontostomatol. (Print) ; 7(1): 99-105, 2013. ilus, tab
Artículo en Inglés | LILACS | ID: lil-690497

RESUMEN

The aim of this study was to evaluate the shear bond strength between acrylic teeth and heat-activated acrylic denture base resin using five different disinfectants solutions after simple immersion or under ultrasonic cleaner action. A total of 144 acrylic denture resin specimens were produced with both types of acrylic denture tooth (Biolux® and Trilux®). The specimens were randomly divided into subgroups according to the disinfection procedure used (immersion in Listerine®, Cepacol®, Periogard®, Riozyme II® and Cloro Rio® 1%, and/or ultrasonic cleaning action). The shear bond strength between acrylic teeth and denture base was assessed using a universal testing machine and the data obtained were analyzed by means of ANOVA followed by Fisher's LSD Multiple-Comparison test. The two layers teeth presented a bond strength average of 3.43 MPa while the three layer ones had an average of 3.02 MPa. The association of ultrasonic cleaner and the disinfectant solutions studied did not affect negatively the teeth bond resistance to the denture base. The three layer acrylic teeth had a lower shear bond strength compared to those with double pressing when immersed in disinfection solutions, regardless of the ultrasonic cleaner use.


El objetivo de este estudio fue evaluar la resistencia al cizallamiento entre dientes de resina acrílica y bases acrílicas curadas mediante calor, junto al uso de cinco soluciones de desinfectantes diferentes, mediante inmersión simple o bajo ultrasonido. Un total de 144 bases de acrílico fueron confeccionadas con los dos tipos de dientes de resina (Biolux ® y Trilux ®). Los especímenes se dividieron aleatoriamente en subgrupos de acuerdo con el procedimiento de desinfección utilizado (inmersión en Listerine ®, Cepacol ®, Periogard ®, Riozyme II ® y Cloro Río ® 1%, y/o acción de limpieza por ultrasonido). Se evaluó la resistencia al cizallamiento entre los dientes de resina y la base de la prótesis utilizando una máquina de ensayo universal; los datos obtenidos se analizaron mediante ANOVA seguido por el test LSD de Fisher de comparaciones múltiples. Las dos capas de los dientes presentaron una fuerza de adherencia promedio de 3,43 MPa, mientras que las tres capas tenían un promedio de 3,02 MPa. La asociación de limpiador ultrasónico y las soluciones desinfectantes estudiados no afectaron negativamente la resistencia de los dientes a la base de la prótesis. Las tres capas de acrílico de los dientes tuvieron una resistencia al cizallamiento menor en comparación con aquellos con doble prensado cuando se sumergen en soluciones desinfectantes, independientemente del uso de limpiador ultrasónico.

17.
Acta odontol. venez ; 50(4)2012. tab
Artículo en Español | LILACS | ID: lil-679001

RESUMEN

Fue evaluado el efecto del grabado de la dentina radicular con EDTA en la resistencia de unión (RU) inmediata (IM) y después de termociclaje (TM) de un cemento autoadhesivo (AA) y uno auto grabador (AG) para la cementación de postes de fibra de vidrio. Fueron utilizadas 40 raíces de premolares humanos divididas en 4 grupos según tipo de cementación (n=10) G1 RelyX U100 (UC) según indicaciones del fabricante(IF); G2 grabado con EDTA 24% por 60 s antes de la aplicación del UC ; G3 Para Post Para Core Automix (PC) (IF)G4 - grabado con EDTA 24% por 60 s antes de la aplicación del (PC).Las raíces fueron cortadas en discos de 1 mm (dos discos por tercio radicular), la mitad de los discos fueron sometidos a ensayo expulsión IM (0,5mm/min) y la otra mitad después de TM (5º C e 55º C).los datos fueron analizados en test de ANOVA y Tukey (?=0,05).dando como resultado que el grabado con EDTA altero negativamente los valores de RU solo del tercio cervical en los dos cementos. Cuando fue comparado TM con IM con o sin aplicación de EDTA no se encontraron diferencias estadísticas significativas. Para todos los grupos testados.El cemento PC obtuvo mayores valores de RU (19,59 MPa) comparado con el UC (15,80 MPa).concluyéndose que el tratamiento con EDTA afecto la RU solo para el tercio cervical tanto en IM como TM en los dos cementos. El TM con o sin EDTA no afecto los valores de RU cuando comparado con IM


The effect of post-space treatment whit EDTA on the bond strength (BS) of fiber posts in different root regions was evaluated using two different type of resin cements Rely X U100 (UC) and Para Post Para Core automix (PC) . Fourty extracted premolars root canals were assigned to four groups of 10 roots each. G1 RelyX U100 (UC) according to manufacturer's instructions (MI), G2 etching whit EDTA 24% for 60 s before application of UC; G3 Para Post Para Core Automix (PC) MI; G4 Etching whit EDTA 24% for 60s before application off PC. After cementation the roots were sectioned in 6 slices 1mm each (two slides for root region) and randomly divided into two subgroups, depending on testing time immediate (IM) vs. after termocicling(TM) ), for expulsion test. Statistical analysis was performed with ANOVA and Tukey test (?=.05) No differences in BS was found among the groups whit and whit out EDTA 24 %. Etching whit EDTA adversely alter the BS values of the cervical third in the two cements. When TM was compared with IM with or without application of EDTA there was no statistically significant difference. For all groups tested, PC show higher values of BS (19.59 MPa) was compared with UC (15.80 MPa). Concluded that treatment with EDTA affected the BS only on the cervical third in both IM and TM in the two cements. The TM with or without EDTA did not affect the values of BS when compared with IM


Asunto(s)
Humanos , Ácido Edético , Ácido Edético/uso terapéutico , Cementos de Resina/uso terapéutico , Dentina/patología , Moldes Quirúrgicos , Selladores de Fosas y Fisuras/uso terapéutico
18.
Acta odontol. venez ; 46(2): 176-179, jun. 2008. tab
Artículo en Español | LILACS | ID: lil-630010

RESUMEN

El objetivo de este trabajo fue comparar la fuerza de adhesión de dos sistemas adhesivos dentinários en dientes deciduos. Treinta y seis dientes deciduos fueron seleccionados y almacenados en agua en temperatura ambiente por un período no superior a 6 meses después de la extracción. Los dientes fueron incluidos en resina acrílica de autocurado y desgastados hasta exponer la dentina. Los especimenes fueron seleccionados y divididos en 4 grupos (n = 9), en cada uno de ellos fue demarcada una área de 2mm de diámetro, donde se aplicaron los adhesivos: Adhese ® y Clearfil SE Bond®, para adherir conos de resina compuesta y compómero que fueron construidos para el experimento. Fueron sometidos a prueba las siguientes combinaciones: G1 = Adhese® + Filtek Z-250®, G2 = Adhese® + Dyract®, G3 = Clearfil SE Bond® + Filtek Z-250® and G4 = Clearfil SE Bond® + Dyract®. Después de 48 horas en agua destilada, se realizó la prueba de resistencia al cizallamiento (1.0 mm/minuto). Finalizada la prueba en los 4 grupos, los especimenes fueron observados en estéreo microscopio para verificar el tipo de fractura. La fuerza de adhesión varió de 3.77 a 7.90 MPa. No fueron observadas diferencias estadísticamente significantes (p > 0.05) y el tipo de fractura mas común fue la adhesiva. El mayor valor de adhesión fue encontrado en el G4 y el menor en el G1, no se observaron diferencias estadísticamente significativas entre los grupos


The aim of this study was to compare the shear bond strengths of two adhesive systems to the dentine of primary teeth. Thirty-six human non-carious primary teeth were collected and stored in water at room temperature for no longer than 6 months after extraction. The teeth were embedded in acrylic resin and the dentin was exposed (carbide paper 120, 400 and 600 grit) and the specimens were randomly assigned in four groups (n=9). A 2mm-diameter dentin bonding site was demarcated, the adhesive systems (Adhese® and Clearfil SE Bond®) were applied and resin composite and compomers cones were bonded. The following 4 combinations were tested: G1 = Adhese® + Filtek Z-250®, G2 = Adhese® + Dyract®, G3 = Clearfil SE Bond® + Filtek Z-250® and G4 = Clearfil SE Bond® + Dyract®. After 48 hours in distilled water, tensile bond strength was tested to failure (1.0 mm/minute). After measuring shear bond strengths, specimens were prepared for stereomicroscopy evaluation and identification of failure type. Shear bond strength values ranged from 3.77 to 7.90 MPa. No statistically significant differences were found among the shear bond strengths (p > 0.05) of the groups and the mode of failure was mostly adhesive. The highest shear bond strength was achieved by G4 and the lowest by G1 and no differences statistically between the groups were observed


Asunto(s)
Recubrimiento Dental Adhesivo , Resistencia al Corte , Adhesivos , Resinas Compuestas
19.
Acta odontol. venez ; 46(4): 416-422, 2008. ilus, tab
Artículo en Español | LILACS | ID: lil-630042

RESUMEN

Esta investigación analizó comparativamente los ensayos mecánicos de cizallamiento y microcizallamiento, a través de una evaluación de resistencia de unión dentina-compósito, utilizando dos técnicas de unión (autocondicionante y condicionamiento ácido total). Las coronas de cuarenta incisivos de bovinos fueron incluidas em tubos de PVC con resina acrílica. Las caras vestibulares fueron desgastadas hasta la exposición de tejido dentinario con hojas de lijar de carburo de silicio. Para la técnica de cizallamiento se delimito un área de 4mm de diámetro donde fue aplicado el sistema adhesivo de acuerdo con instrucciones del fabricante. Un cilindro de compósito restaurador (Filtek Z250 - 3M ESPE) de 4mm de diámetro y altura de 5mm fue construido en el área. Las muestras para el microcizallamiento fueron confeccionadas utilizando tubos de Tygon con diámetro interno de 0,7 mm y altura de 0,5mm en los cuales el mismo compósito restaurador fue colocado. La carga para ambos experimentos fue realizada a una velocidad de 1.0mm/min con alambre de ortodoncia de 0,3mm de diámetro. Los resultados muestran que para el experimento de cizallamiento el Adper Single Bond presentó valores estadísticamente superiores AL Clearfil SE Bond (p = 0,037). Para el microcizallamiento no hubo diferencias estadísticas (p = 0,780). Los cuerpos de prueba fueron sometidos al análisis de microscopia electrónica de barrido para clasificar el tipo de fractura. En el experimento de cizallamiento, existieron fallas adhesivas, cohesivas y mixtas en dentina para los dos sistemas adhesivos. En el experimento de microcizallamiento, se observó alta prevalencia de fallas adhesivas. Los resultados permitieron concluir que el microcizallamiento se mostró más apropiado para evaluar la resistencia de la unión adhesiva en la interfase compósito/dentina


The aim of this study was to evaluate comparatively the methodology of micro-shear and shear bond strength using the two available bonding strategies self etching and total etching techniques. Forty bovine incisors were cut and embedded in PVC tubes with acrylic resin. The buccal surfaces were flattened and exposed with SiC paper. For the shear bond strength test, an area of 4mm in diameter was delimited and the adhesive systems were applied according to the manufacturer's instructions. A composite cylinder (Filtek-Z250 - 3M ESPE) of 4mm diameter and 5mm height were built in the area. The samples for microshear were made use of Tygon tubes with 0,7mm in internal diameter in 0,5mm height, using the same composite. Loading were carried out at crosshead speed of 1,0mm/min using an orthodontic wire loop of 0,3mm diameter. The results showed that for shear test the Adper Single Bond presented higher values with statistical significance to Clearfil SE Bond (p=0,037). For the micro-shear test statistical difference was not observed (p=0,780). The samples were submitted to SEM for a fracture pattern classification. For the shear bond test were observed adhesive and dentin cohesive failures for both adhesive systems. For micro-shear bond test were observed a high prevalence of adhesive failures. According to the results it was possible to conclude that micro-shear bond test was more appropriated to evaluate the resistance of bond strength in interface composite/dentin


Asunto(s)
Femenino , Adhesivos , Cementos de Resina , Resistencia al Corte , Odontología
20.
Rev. enferm. Inst. Mex. Seguro Soc ; 13(3): 147-152, Septiembre.-Dic. 2005. graf, tab
Artículo en Español | LILACS, BDENF | ID: biblio-968664

RESUMEN

Introducción: El déficit de movilidad relacionado al confinamiento en cama por periodos prolongados es uno de los principales factores de predisposición para úlceras por presión. Objetivo: Describir la incidencia, características demográficas, clínicas y factores relacionados con el desarrollo de úlceras por presión en pacientes adultos hospitalizados en un tercer nivel de atención en el IMSS. Metodología: Se seleccionó a 92 pacientes adultos susceptibles de presentar úlceras por presión, con 72 horas de hospitalización en los servicios de Cirugía, Medicina Interna, Neurocirugía, Ortopedia y Unidad de Cuidados Intensivos. En cada paciente se realizó una valoración inicial y seguimiento cada 72 horas hasta su egreso, de las variables demográficas y factores relacionados con la presencia de úlceras por presión. Las características demográficas y clínicas se analizaron con medidas de frecuencia y tendencia central. Se estimó incidencia acumulada de las úlceras por presión y correlación entre variables, con análisis multivariado de las características relevantes. Resultados: La incidencia fue de 4.5%. De los 24 pacientes que presentaron úlceras por presión, se localizaron en talón derecho 70%, talón izquierdo 9% y sacro 9%. En 11 pacientes se presentó una segunda úlcera, en talón izquierdo (54%), sacro (18%) y talón derecho (18%). Por análisis bivariado se encontró correlación con movilidad disminuida, humedad y cizallamiento. Conclusiones: La incidencia y características de los pacientes son similares a los informados en otros estudios. En el presente, el perfil de riesgo para desarrollo de úlceras por presión, incluye edad promedio de 65 años, diagnóstico de fractura de cadera, presencia de humedad, movilidad limitada, fricción y deslizamiento constante. Es primordial la valoración inicial de los factores de riesgo para úlceras por presión al ingreso del paciente.


Introduction: Lack of mobility related to lying down on bed during long periods of time is one of the main factors to predispose to have pressure ulcers. Exposure time to this and other factors determine the frequency and placement of ulcers in the sacra region, heels, and hips. Objective: To describe the incidence, demographic characteristics, clinics, and related factors to the development of pressure ulcers in hospitalized adult patients in hospitals of third level of assistance in the Instituto Mexicano del Seguro Social. Methodology: 92 adult patients susceptible to develop pressure ulcers, within 72 hours of hospitalization in Surgery, Internal Medicine, Neurosurgery, Orthopedics, and Intensive Care Unit were selected. An initial assessment and follow up every 72 hours were done to each patient until discharge them, about demographic variables and related factors with the presence of pressure ulcers. The demographic and clinic characteristics were analyzed with frequency scores and central tendency. It was estimated an accumulated incidence of pressure ulcers and co-relation among variables, with multivariate analysis of relevant characteristics. Results: The incidence was 4.5%. From 24 patients who had pressure ulcers, these were located 70% on right heel, 9% on left heel, and 9% on sacral area. 11 patients had a second ulcer: 54% on left heel, 18% sacral area, and 18% rightheel.Throughbi-varied,aco-relation with diminished mobility, humidity, and attrition were found. Conclusions: The incidence and characteristics of patients were similar to those reported in other studies. In this study, the risk range to develop pressure ulcer include: average age 65 years old, diagnosis of hip fracture, presence of humidity, limited mobility, friction, and constant sliding. Initial assessment of risk factors is primordial during patient intake.


Asunto(s)
Humanos , Anciano , Adulto , Úlcera por Presión , Hospitales Especializados , Humedad , Pacientes Internos , México
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA