1.
Chinese Journal of Laboratory Medicine ; (12): 725-731, 2023.
Artículo en Chino | WPRIM | ID: wpr-995784

RESUMEN

Objective:To establish a new strategy for rapid correction of the interference of chyle blood on hemoglobin (HGB) and related indexes by reticulocyte (RET) channel research parameters (HGB-O, MCHC-O) from automatic hematological analyzer.Methods:With the diagnostic experimental design, a total of 90 impatient samples were sequential picked from Fuwai Hospital, which had routine blood testing from June 1 to July 31, 2021. The selected samples were free of hemolysis, jaundice, chylo. The age of the patients was (49.2±5.7) years, with 47 males and 43 females. Three different contents(25, 50, 75 μl) of fat emulsion injection were used to replace plasma in equal amounts to prepare chyle blood samples with mild, medium and heavy degrees of average red blood cell hemoglobin concentration (MCHC). The research parameters (HGB-O, MCHC-O) obtained by the RET channel detection of the automatic blood analyzer were used as the corrected HGB and its related index values (RET method), and the original values (the detection values before adding fat emulsion) and the formula correction values were paired with t-test or Wilcoxon signed rank test, single factor analysis of variance or Kruskal-Wallis rank-sum test, Bland-Altman and correlation analysis to evaluate the correction effect of RET method.Results:There was no significant difference ( H=0.035, P=0.983; H=0.097, P=0.953; H=0.112, P=0.945) between the RET correction values of HGB (g/L) [104.0(83.8, 132.8), 109.0(87.78, 128.25), 104.0(87.8, 131.8)] and the original values [104.0(83.0, 133.0), 107.5(86.75, 129.25), 103.5(85.8, 131.3)] and the formula correction values [104.0(84.0, 133.8), 106.0(86.75, 131.25), 102.5(86.8, 131.3)] in the samples of chythemia with varying degrees of MCHC (g/L) elevation; meanwhile, the RET correction values [366.5(325.8, 341.5), 333.5(323.8, 340.0), 333.5(327.0, 341.25)] and the original values [336.0(324.8, 342.0), 333.0(323.5, 342.3), 332.0(326.75, 340.5)] and the formula correction values [333.5(323.5, 343.3), 331.0(321.0, 338.3), 329.5(325.25, 337.25)] were also not statistically significant ( H=0.049, P=0.976; H=3.149, P=0.207; H=0.883, P=0.643). The detection values of HGB and related indexes corrected by RET method were in good agreement with the original values [96.7% (29/30) of the points were within the 95% consistency limit], and the two were positively correlated (the correlation coefficients were all higher than 0.919, P<0.01). Conclusion:The RET method based on the research parameters of RET channel of automatic hematological analyzer can serve as a new strategy to correct the interference of chyle blood on the detection of HGB and related indexes.

2.
Chinese Journal of Medical Education Research ; (12): 1353-1356, 2021.
Artículo en Chino | WPRIM | ID: wpr-909023

RESUMEN

Objective:To analyze the application effect of day checklist model combined with fault finding and error correction method in the teaching of new nurses in neurology department.Methods:A total of 42 new neurology nurses accepted in the department of neurology from January 2019 to June 2020 were selected in the study and they were divided into control group and study group. The conventional group was given the conventional teaching method, while the study group was given the day checklist model combined with fault finding and error correction method, both of which were taught for 3 months. Assessment performance of theoretical knowledge and operational skills before and after teaching, critical thinking ability before and after teaching and satisfaction with the teaching after teaching in neurology nursing were compared between the two groups. SPSS 25.0 was used for t test and rank sum test. Results:After teaching, assessment performance of theoretical knowledge and operational skills, the 7 dimensions of critical thinking ability scores and the total scores were higher than those before teaching, and the study group did better than the control group ( P < 0.05). There were significant differences between the 2 groups of new nurses in the distribution of satisfaction with teaching ( P < 0.05), and the total satisfaction rate of the study group (100.00%) was higher than that of the control group (80.96%) ( P < 0.05). Conclusion:Using the method of day checklist model combined with fault finding and error correction method in the teaching of new nurses in the neurology department can improve their assessment results, enhance their critical thinking ability and improve the teaching satisfaction.

3.
China Pharmacy ; (12): 1179-1184, 2020.
Artículo en Chino | WPRIM | ID: wpr-821603

RESUMEN

OBJECTIVE:To e stablish a method for simultaneous determination of 7 constituents in Xiao ’er jinqiao granules . METHODS:QAMS method was adopted. The determination was performed on Lubex Kromasil C 18 column with mobile phase consisted of acetonitrile- 0.1% phosphoric acid solution (gradient elution ). The detection wavelength was set at 326 nm,the flow rate was 1.0 mL/min. The column temperature was 40 ℃,and sample size was 10 µL. Using chlorogenic acid as the internal reference,the relative correction factors (RCF)of neochlorogenic acid ,cryptochlorogenic acid ,forsythiaside A ,isochlorogenic acid B ,isochlorogenic acid A and isochlorogenic acid C were calculated. The effects of different chromatogram system , chromatogram column ,the ratio of mobile phase ,flow rate and column temperature on RCF were investigaten. According to the two-point correction method combined with the relative retention time correction of the components to be tested ,the peak location was carried out. The contents of 7 components were determined by QAMS and SCM respectively and then compared. RESULTS: The linear range of neochlorogenic acid ,chlorogenic acid ,cryptochlorogenic acid ,forsythoside A ,isochlorogenic acid B ,isochlorogenic acid A ,isochlorogenic acid C were 9.27-92.70,37.36-373.60,13.02-130.20,7.15-71.50,4.56-45.60,6.32-63.20,14.69-146.90 µg/mL (r≥0.999 7). The limits of quantification were 1.38,1.41,1.40,1.99,1.10,1.17,1.10 ng,respectively;and the limits of detection were 0.41,0.42,0.42,0.60,0.33,0.35,0.33 ng,respectively. RSDs of precision ,repeatability and stability tests were all less than 2%;average recoveries were 98.28%-99.15% (RSD<2.0% , n=9). RCFs of neochlorogenic acid , (No.2013LZLY-K61) cryptochlorogenic acid ,forsythiaside A ,isochlorogenic acid B,isochlorogenic acid A and isochlorogenic acid C relative to xinyuliang@stu.cqmu.edu.cn chlorogenic acid were 0.995,1.007,0.580,1.243,1.252 and 1.247,respectively. RSDs of RCFs were all lower than 3% under different chromatogram conditions. Absolute value of relative error between the relative retention time of components to be tested predicted by two-point correction combined with relative retention time correction and measured value was less than 2%. The contents measured by QAMS were 2.790-3.416, 14.526-17.907,3.763-4.531,1.625-1.982,1.087-1.523,1.434-2.219,3.631-5.078 mg/g;the contents measured by SCM method were 2.811-3.438,14.512-17.893,3.739-4.508,1.656-2.012,1.108-1.544,1.460-2.245,3.597-5.045 mg/g;relative errors of the two methods were within ±2%. CONCLUSIONS :Two-point correction method combined with relative retention time correction can accurately locate the peaks of each constituent ;established QAMS method is simple ,rapid,accurate and reliable ,it can be used for simultaneous determination of 7 constituents in Xiao ’er jinqiao granules.

4.
Journal of China Pharmaceutical University ; (6): 50-54, 2010.
Artículo en Chino | WPRIM | ID: wpr-480384

RESUMEN

Aim: To establish a simple and convenient quality evaluation method for Fructus Gardeniae(FG).Methods: The internal standard correction factors(f_(km))of four crocetin derivatives to crocin-1 were established and the system suitability was tested.The content of crocin-1 was determined by external standard method,the contents of other crocetin derivatives were calculated by the content of crocin-1 and their f_(km).Results: There was no significant difference between the test results obtained by the methods oftheoretical calculation by f_(km)androutire determination technique.Conclusion: The internal standard correction method(the method oftheoreti-cal calculation by f_(km))is practical and feasible in the quantitative analysis of Frnctus Gardeniae.