Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Añadir filtros








Intervalo de año
1.
Arq. bras. oftalmol ; 86(4): 365-371, July-Sep. 2023. tab, graf
Artículo en Inglés | LILACS-Express | LILACS | ID: biblio-1447370

RESUMEN

ABSTRACT Purpose: To compare ocular surface parameters in rosacea patients with those of controls. Methods: Ninety-three participants took part in this cross-sectional, observational, non-interventional study. These consisted of a rosacea group (n=40) and a control group (n=53). We compared objective parameters of the ocular surface, including conjunctival hyperemia, tear film stability and volume, meibomian gland dysfunction, dry eye disease, and ocular surface staining, between the two groups. Results: In the rosacea group, 69.23% were female. The mean age was 47.34 ± 12.62 years old. No statistically significant differences between groups were found in visual acuity (p=0.987), tear film parameters (tear meniscus height (p=0.338), noninvasive tear film rupture time (p=0.228), invasive rupture time (p=0.471), Schirmer's test scores (p=0.244), conjunctival hyperemia (p=0.106), and fluorescein staining (p=0.489). Significant differences were found in meibography evaluations (p=0.026), mucous layer integrity (p=0.015), and ocular surface symptoms (p<0.0001). Rosacea patients also showed important eyelid differences in glandular expressibility (p<0.001), glandular secretion pattern (p<0.001), and telangiectasia (p<0.001) compared to controls. Conclusion: Meibomian gland dysfunction is frequently associated with dermatological conditions. It can be observed in morphological findings from meibography as well as lipid secretion impairment, leading to evaporative dry eye, ocular surface dysfunction, and inflammation.


RESUMO Objetivo: Avaliar as alterações da superfície ocular em pacientes com Rosácea, e comparar com grupo controle. Métodos: Noventa e três indivíduos foram selecionados para este estudo transversal, observacional e não intervencionista, dividido em dois grupos: rosácea (n=40) e controles (n=53). Foram avaliados parâmetros objetivos da superfície ocular (hiperemia conjuntival, estabilidade e volume do filme lacrimal, disfunção da glândula meibomiana, doença do olho seco, coloração da superfície ocular) e comparado indivíduos saudáveis com pacientes com rosácea. Resultados: 69,23% dos indivíduos com rosácea eram mulheres, com média de idade de 47,34 ± 12,62 anos. Em comparação com controles pareados, não foram evidenciadas diferenças estatisticamente significativas em relação à acuidade visual (p=0,987) e parâmetros do filme lacrimal (altura do menisco lacrimal (p=0,338), tempo de ruptura do filme lacrimal não invasivo (p=0,228), tempo invasivo de ruptura (p=0,471) e teste de Schirmer (p=0,244), bem como hiperemia conjuntival (p=0,106) e coloração com fluoresceína (p=0,489). Associação significativa foi encontrada na avaliação da meibografia (p=0,026), integridade da camada mucosa (p=0,015) e sintomas de superfície ocular (p<0,0001). Pacientes com rosácea também apresentaram alterações importantes na borda palpebral: expressibilidade glandular (p<0,001), padrão de secreção glandular (p<0,001) e telangiectasia (p<0,001). Conclusão: A disfunção da glândula de Meibômio está frequentemente associada a condições dermatológicas e é caracterizada por achados morfológicos na meibografia, bem como comprometimento da secreção lipídica que leva ao olho seco evaporativo e alterações da superfície ocular e inflamação.

2.
Arq. bras. oftalmol ; 86(5): e20230069, 2023. tab, graf
Artículo en Inglés | LILACS-Express | LILACS | ID: biblio-1513687

RESUMEN

ABSTRACT Purpose: The study aimed to evaluate the ocular surface and meibomian gland morphology in electronic cigarette (e-cigarette) smokers. Methods: The upper and lower eyelids of 25 male e-cigarette smokers and 25 healthy male non-smoker patients were evaluated using Sirius meibography. Meibomian glands loss was automatically calculated using Phoenix meibography imaging software module, with the result obtained as percentage loss. Ocular Surface Disease Index (OSDI) questionnaire, tear breakup time test, and Schirmer II test were administered and performed in all cases. Results: The mean e-cigarette smoking duration was 4.9 ± 0.9 (range, 3.4-7) years. While the mean Schirmer II test value was 9.16 ± 2.09 mm in e-cigarette group, it was 11.20 ± 2.14 mm in control group (p=0.003). Mean tear breakup time was 6.96 ± 2.31 seconds in e-cigarette group and 9.84 ± 2.13 seconds in control group (p=0.002). The mean OSDI value was 28.60 ± 6.54 and 15.16 ± 7.23 in e-cigarette and control groups, respectively (p<0.001). In Sirius meibography, the average loss for the upper eyelid was 23.08% ± 6.55% in e-cigarette group and 17.60% ± 4.94% in control group (p=0.002), and the average loss for the lower eyelid was 27.84% ± 5.98% and 18.44% ± 5.91%, respectively (p<0.001). Additionally, a significant positive correlation was identified between the loss rates for both upper and lower eyelid meibography with e-cigarette smoking duration (r=0.348, p<0.013 and r=0.550, p<0.001, respectively). Conclusion: Long-term e-cigarette smoking causes damage to the meibomian glands; therefore, meibomian gland damage should be considered in ocular surface disorders due to e-ci­garette smoking.


RESUMO Objetivo: Avaliar a superfície ocular e a morfologia da glândula meibomiana em usuários de cigarros eletrônicos. Métodos: Foram avaliadas através de meibografia Sirius as pálpebras superiores e inferiores de 25 usuários de cigarros eletrônicos do sexo masculino e 25 pacientes não usuários saudáveis, também do sexo masculino. A perda nas glândulas meibomianas foi calculada automaticamente com o módulo de software de imagem de meibografia Phoenix. O resultado foi obtido como perda percentual. O questionário Ocular Surface Disease Index (OSDI), o teste do tempo de ruptura lacrimal e o teste de Schirmer II foram administrados em todos os casos. Resultados: A duração média do uso de cigarros eletrônicos foi de 4,9 ± 0,9 anos (intervalo de 3,4-7 anos). O valor médio do teste de Schirmer II foi de 9,16 ± 2,09 mm no grupo de usuários de cigarros eletrônicos e de 11,20 ± 2,14 mm no grupo controle (p=0,003). O valor médio do teste do tempo de ruptura lacrimal foi de 6,96 ± 2,31 segundos no grupo de usuários de cigarros eletrônicos e 9,84 ± 2,13 segundos no grupo controle (p=0,002). O valor médio do Ocular Surface Disease Index foi de 28,60 ± 6,54 e 15,16 ± 7,23 para os grupos de usuários de cigarros eletrônicos e controle, respectivamente (p<0,001). Na meibografia de Sirius, a perda média para a pálpebra superior foi de 23,08 ± 6,55% para o grupo de usuários de cigarros eletrônicos e 17,60 ± 4,94% para o grupo controle (p=0,002), e a perda média para a pálpebra inferior foi de 27,84 ± 5,98% e 18,44 ± 5,91%, respectivamente (p<0,001). Além disso, foi observada uma correlação positiva significativa entre a taxa de perda na meibografia palpebral superior e inferior com a duração do tabagismo eletrônico, respectivamente de (r=0,348, p<0,013) e (r=0,550, p<0,001). Conclusão: O uso prolongado de cigarros eletrônicos causa danos às glândulas meibomianas. Portanto, esses danos devem ser considerados em distúrbios da superfície ocular devidos ao uso desses dispositivos.

3.
Arq. bras. oftalmol ; 85(4): 406-410, July-Aug. 2022. graf
Artículo en Inglés | LILACS-Express | LILACS | ID: biblio-1383835

RESUMEN

ABSTRACT The objective of this report is to describe a case of meibomian gland dysfunction associated with keratoconus and to examine the importance of treatment for evaporative dry eye in cases of corneal ectasia. A 45-year-old man diagnosed as having keratoconus complained of burning, tearing, itching, and red eye. He had a history of penetrating corneal transplantation and wearing rigid contact lenses. The meibography revealed a severe meibomian gland dropout and normal tear meniscus height in both eyes. Objective propaedeutic tests are important tools for dry eye diagnosis and proper evaluation of ocular surface and tear film. In older patients, the classic signs of atopic conjunctivitis are not always present, and the causes of chronic rubbing must be further investigated. Treatment of underlying chronic inflammation such as dry eye, meibomian gland dysfunction, and blepharitis might be important to prevent keratoconus progression and guarantee symptom relief.


RESUMO O objetivo é relatar um caso de associação entre disfunção de glândulas de meibomius (DGM) e ceratocone, assim como ressaltar a importância do tratamento do olho seco evaporativo em casos de ectasia corneana. Paciente do sexo masculino de 45 anos com ceratocone e queixas de ardência, lacrimejamento, prurido e olho vermelho. O mesmo tem histórico de transplante de córnea penetrante e uso de lentes de contato rígidas. A meibografia revelou severa perda de glândulas de meibomius e menisco lacrimal normal em ambos os olhos. Testes propedêuticos objetivos são importantes ferramentas para diagnóstico de olho seco e apropriada avaliação da superfície ocular e filme lacrimal. Em pacientes mais velhos, os sinais clássicos de atopia não estão sempre presentes e investigações adicionais das causas de prurido crônico são necessárias. O tratamento da inflamação crônica subjacente como olho seco, disfunção de glândulas de meibomius e blefarite podem ser importantes para prevenir a progressão do ceratocone e garantir alívio dos sintomas.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA