Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Añadir filtros








Intervalo de año
1.
Organ Transplantation ; (6): 151-159, 2024.
Artículo en Chino | WPRIM | ID: wpr-1005246

RESUMEN

With widespread application of solid organ transplantation (SOT), the incidence of postoperative invasive fungal disease (IFD) in SOT recipients has been increased year by year. In recent years, the awareness of preventive antifungal therapy for SOT recipients has been gradually strengthened. However, the problem of fungal resistance has also emerged, leading to unsatisfactory efficacy of original standardized antifungal regimens. Drug-drug interaction and hepatorenal toxicity induced by drugs are also challenges facing clinicians. In this article, the characteristics of drug-drug interaction and hepatorenal toxicity among triazole, echinocandin and polyene antifungal drugs and immunosuppressants were reviewed, and postoperative preventive strategies for IFD in different types of SOT recipients and treatment strategies for IFD caused by infection of different pathogens were summarized, aiming to provide reference for physicians in organ transplantation and related disciplines.

2.
Journal of Pharmaceutical Practice ; (6): 566-568, 2021.
Artículo en Chino | WPRIM | ID: wpr-904762

RESUMEN

Objective To explore the role of clinical pharmacists in the treatment of drug poisoning by analyzing the clinical pharmacist's participation in the treatment of a patient with sodium valproate poisoning. Methods Clinical pharmacists measured the plasma concentration of sodium valproate to inform the doctor to diagnose illnesses. At the initial stage when the concentration is high, to eliminate the free drug by continuous venous-venous hemodialysis-filtration (CVVHDF). Then, the combined drug was cleared by hemoperfusion (HP). Results The blood concentration dropped by half at the first CVVHDF and decreased obviously after two HPs. After stable observation in five days’ course of disease, the blood concentration was maintained at a low level and the patient was cured and discharged. Conclusion The implementation of the blood purification program under the monitoring of the blood drug concentration with the participation of pharmacists is helpful for the rescue of drug overdose and is worthy of promotion.

3.
Chinese Journal of Laboratory Medicine ; (12): 703-708, 2021.
Artículo en Chino | WPRIM | ID: wpr-912461

RESUMEN

Objective:To establish an ultra-high-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) method for plasma caffeine concentration detection, and to explore the clinical value of caffeine therapeutic drug monitoring (TDM) in the treatment of premature infants with respiratory distress syndrome (RDS).Method:Take the plasma sample in a centrifuge tube, add the caffeine deuterated isotope internal standard, then add the protein precipitant, vortex the mixture thoroughly, and centrifuge the supernatant to enter the mass spectrometry analysis. The mobile phase were methanol and water, gradient elution; the column temperature was 45 ℃, the method was established using Shimadzu LC-30AD-CL liquid system and AB SCIEX 4500 QTRAP mass spectrometer, and the sensitivity, specificity, linearity, accuracy imprecision, matrix effect, and carry-over of the method were evaluated. Sample from 30 patients diagnosed with neonatal RSD were collected in the Department of Neonatology of Renmin Hospital of Wuhan University from February to April 2021, then detected the trough concentration of caffeine in premature infants with RDS after taking the same dose of caffeine to assess the impact of individual variation on caffeine drug concentration.Results:The detection limit of caffeine was 0.02 μg/ml, and the lowest limit of quantification was 0.05 μg/ml. It showed good linearity ( R2=0.9986, R>0.99) in the concentration range from 1.0 to 100.0 μg/ml, specificity (recovery rate of 85.52%-114.12%), accuracy (recovery rate 85.97%-114.53%), intra-day and inter-day imprecision ( CV 6.01%-11.28%), matrix effects and carryover pollution were negligible. The trough concentration of 30 preterm infants with RSD after taking the same dose of caffeine (10 mg/kg) was (25.45±11.61) μg/ml, and the coefficient of variation was 44.88%. Conclusion:This study established an accurate and reliable UPLC-MS/MS method with low sample consumption to monitor the blood concentration of caffeine; caffeine TDM has certain clinical application value, which can be used to assist RDS diagnosis and treatment and improve the efficacy of caffeine.

4.
China Pharmacy ; (12)1991.
Artículo en Chino | WPRIM | ID: wpr-516209

RESUMEN

This paper describes the present status and existing problems of clinically monitoring blood drug concentrations, in hospital pharmacy in Shanxi Province. The ways to solve these problems are suggested.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA