Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Añadir filtros








Intervalo de año
1.
Braz. dent. sci ; 21(1): 44-53, 2018. ilus, tab
Artículo en Inglés | LILACS, BBO | ID: biblio-881832

RESUMEN

The temporomandibular joint (TMJ) is one of the most complex joints in the body and its harmonious functioning is very important to maintain a normal masticatory system. The morphologic alterations and the asymmetrical position of the TMJ structures may lead the various clinicalsigns & symptoms. Morphology of the temporomandibular joint may be influenced by gender of patients, environmental factor and also food habits at various places. Objective: To evaluate the morphology of the temporomandibular joint using computed tomography, in order to determine the condyle shape, joint space and glenoid fossa roof thickness. Material and Methods: One hundred and six healthy patients (212 TMJs) who visited a private hospital (or the University's Hospital) for CT brain scan were included to this crosssectional study sample.The patients were aged between 20­50 years with an average age of 35.46 years. All the images were taken by positioning patients in supine position with 120kvp , 50ma,2.33minute exposure with 0.7mm thick slicesby computed topography machine in all three projection that is Axial, Coronal and Saggital view. Results: For all variables, the mean and standard deviation were calculated, based on gender, and TMJ sides. The Paired t-test was used and P <0.05 will be considered to be significant. Conclusion: Present study showed that thereis positive evidence of temporomandibular joint involvement in elderly patients. Change in morphology and position of condylar head with glenoid fossa and roof thickness are one of the most common cause of degenerative diseases (AU)


Objetivo: A articulação temporomandibular (ATM) é uma das articulações mais complexas do corpo e seu funcionamento harmonioso é muito importante para manter um sistema mastigatório. As alterações morfológicas e a posição assimétrica das estruturas da ATM podem levar os vários sinais e sintomas clínicos. A morfologia da articulação temporomandibular pode ser influenciada pelo gênero dos pacientes, fatores ambientais e também hábitos alimentares diversos. Objetivo: Avaliar a morfologia da articulação temporomandibular usando tomografia computadorizada, a fim de determinar a forma do côndilo, o espaço articular, e a espessura do teto da fossa glenóide. Material e Métodos: Cento e seis pacientes saudáveis (212 ATMs) que foram a um hospital privado (ou Hospital da Universidade) para tomografia computadorizada de cérebro foram incluídos na amostra deste estudo transversal. Os pacientes tinham entre 20 e 50 anos com uma idade média de 35,46 anos. Todas as imagens foram tiradas com os pacientes posicionados em decúbito dorsal com 120kvp, 50mA, 2,33minutos de exposição com espessura de 0.7mm nas três projeções: Axial, Coronal e Saggital. Resultados: Para todas as variáveis, a média e desvio padrão foram calculados, com base no sexo e nos lados da ATM. O teste t pareado foi usado e P <0,05 foi considerado significativo. Conclusão: O presente estudo mostrou que há evidências positivas de envolvimento da articulação temporomandibular nos pacientes mais velhos. Mudança na morfologia e posição da cabeça condilar com a espessura do teto da fossa glenóide é uma das causas mais comuns de doenças degenerativas (AU)


Asunto(s)
Huesos , Forma del Núcleo Celular , Articulación Temporomandibular
2.
Rev. bras. reumatol ; 57(2): 154-161, Mar.-Apr. 2017. tab, graf
Artículo en Inglés | LILACS | ID: biblio-844223

RESUMEN

Abstract Objective: To describe the performance of a non-fluoroscopic fixed-flexion PA radiographic protocol with a new positioning device, developed for the assessment of knee osteoarthritis (OA) in Brazilian Longitudinal Study of Adult Health Musculoskeletal Study (ELSA-Brasil MSK). Material and methods: A test–retest design including 19 adults (38 knee images) was conducted. Feasibility of the radiographic protocol was assessed by image quality parameters and presence of radioanatomic alignment according to intermargin distance (IMD) values. Repeatability was assessed for IMD and joint space width (JSW) measured at three different locations. Results: Approximately 90% of knee images presented excellent quality. Frequencies of nearly perfect radioanatomic alignment (IMD ≤1 mm) ranged from 29% to 50%, and satisfactory alignment was found in up to 71% and 76% of the images (IMD ≤1.5 mm and ≤1.7 mm, respectively). Repeatability analyses yielded the following results: IMD [SD of mean difference = 1.08; coefficient of variation (%CV) = 54.68%; intraclass correlation coefficient (ICC) (95%CI) = 0.59 (0.34–0.77)]; JSW [SD of mean difference = 0.34–0.61; %CV = 4.48%–9.80%; ICC (95%CI) = 0.74 (0.55–0.85)–0.94 (0.87–0.97)]. Adequately reproducible measurements of IMD and JSW were found in 68% and 87% of the images, respectively. Conclusions: Despite the difficulty in achieving consistent radioanatomic alignment between subsequent radiographs in terms of IMD, the protocol produced highly repeatable JSW measurements when these were taken at midpoint and 10 mm from the medial extremity of the medial tibial plateau. Therefore, measurements of JSW at these locations can be considered adequate for the assessment of knee OA in ELSA-Brasil MSK.


Resumo Objetivo: Descrever o desempenho de um protocolo radiográfico em flexão fixa sem fluoroscopia em incidência PA com um novo posicionador, desenvolvido para a avaliação da osteoartrite de joelho (OA) no estudo ELSA-Brasil ME. Material e métodos: Fez-se um estudo de teste e reteste que incluiu 19 adultos (38 imagens de joelho). A viabilidade do protocolo radiográfico foi avaliada por meio de parâmetros de qualidade da imagem e presença de alinhamento radioanatômico de acordo com as medidas da distância intermarginal (DIM). Avaliaram-se a repetibilidade dos valores de DIM e do espaço articular (EA) em três locais diferentes. Resultados: Aproximadamente 90% das imagens de joelho apresentaram uma qualidade excelente. As frequências de imagens com alinhamento radioanatômico quase perfeito (DIM<1mm) variaram de 29% a 50%, e de alinhamento satisfatório (DIM<1,5mm e <1,7mm) de 71% a 76%, respectivamente. As análises de repetibilidade produziram os seguintes resultados: DIM [DP da média das diferenças = 1,08; coeficiente de variação (% CV) = 54,68%; coeficiente de correlação intraclasse (CCI) (IC 95%) = 0,59 (0,34 a 0,77)]; EA [DP da média das diferenças = 0,34 a 0,61; % CV = 4,48% a 9,80%; CCI (IC 95%) = 0,74 (0,55 a 0,85) a 0,94 (0,87 a 0,97]. Encontraram-se medidas adequadamente reprodutíveis de DIM e EA em 68% e 87% das imagens, respectivamente. Conclusões: Apesar da dificuldade de obter um alinhamento radioanatômico consistente entre radiografias repetidas em termos de DIM, o protocolo produziu medições de EA altamente repetíveis quando essas foram tomadas no ponto médio e a 10 mm da extremidade medial do platô tibial medial. Portanto, as medidas de EA nesses locais podem ser consideradas adequadas para a avaliação da OA de joelho no estudo ELSA-Brasil ME.


Asunto(s)
Humanos , Masculino , Femenino , Adulto , Osteoartritis de la Rodilla/diagnóstico por imagen , Posicionamiento del Paciente/instrumentación , Articulación de la Rodilla/diagnóstico por imagen , Procesamiento de Imagen Asistido por Computador , Brasil , Radiografía , Radiografía/instrumentación , Estudios de Factibilidad , Reproducibilidad de los Resultados , Estudios Longitudinales , Osteoartritis de la Rodilla/patología , Persona de Mediana Edad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA