Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Añadir filtros








Intervalo de año
1.
Braz. j. pharm. sci ; 50(2): 329-336, Apr-Jun/2014. tab, graf
Artículo en Inglés | LILACS | ID: lil-722177

RESUMEN

The dissolution process is considered an important in vitro tool to evaluate product quality and drug release behavior. Single dissolution methods for the analysis of combined dosage forms are preferred to simplify quality control testing. The objective of the present work was to develop and validate a single dissolution test for a telmisartan (TEL) and amlodipine besylate (AML) combined tablet dosage form. The sink conditions, stability and specificity of both drugs in different dissolution media were tested to choose a discriminatory dissolution method, which uses an USP type-II apparatus with a paddle rotating at 75 rpm, with 900 mL of simulated gastric fluid (SGF without enzymes) as the dissolution medium. This dissolution methodology provided good dissolution profiles for both TEL and AML and was able to discriminate changes in the composition and manufacturing process. To quantify both drugs simultaneously, a synchronous first derivative spectrofluorimetric method was developed and validated. Drug release was analyzed by a fluorimetric method at 458 nm and 675 nm for AML and TEL, respectively. The dissolution method was validated as per ICH guidance.


O processo de dissolução é considerado como uma importante ferramenta in vitro para avaliar a qualidade do produto e o comportamento de liberação do fármaco. Prefere-se um ensaio único de dissolução para formas farmacêuticas contendo associação de fármacos pela simplificação dos testes de controle de qualidade. O objetivo do presente trabalho foi desenvolver e validar um teste de dissolução único para forma farmacêutica comprimidos contendo telmisartana (TEL) e besilato de anlodipino (AML) associados. Condições "sink", estabilidade e especificidade de ambos os fármacos nos diferentes meios de dissolução foram avaliadas para selecionar um método de dissolução discriminatório, que utiliza um aparato do tipo II da USP, com pás girando a 75 rpm e 900 mL de fluido gástrico simulado (SGF sem enzima) como o meio de dissolução. Estas condições proporcionaram bons perfis de dissolução para ambos, TEL e AML, sendo capaz de discriminar as mudanças na composição e processo de fabricação. Para quantificar os dois fármacos simultaneamente, um método de fluorescência derivada sincronizado foi desenvolvido e validado. A quantidade de fármaco liberado foi analisada pelo método fluorimétrico em 458 e 675 nm para a AML e TEL, respectivamente. O método de dissolução foi validado de acordo com a orientação da ICH.


Asunto(s)
Espectrometría de Fluorescencia/métodos , Antihipertensivos , Control de Calidad , Formas de Dosificación , Disolución/clasificación
2.
Braz. j. pharm. sci ; 50(3): 611-619, Jul-Sep/2014. tab, graf
Artículo en Inglés | LILACS | ID: lil-728687

RESUMEN

Here, a spectrofluorimetric method for the determination of potassium losartan (PL) in pharmaceutical products is described. The effects of critical parameters, pH, acid molarity, and temperature, on the fluorescence intensity of PL were analyzed, and these parameters were optimized using a central composite design (CCD). The highest fluorescent intensity at excitation (λex) and emission (λem) wavelengths of 248 nm and 410 nm, respectively, was achieved using 0.01 M sulfurous acid (pH 2) at 21.6 °C. Under optimum conditions, the method was linear from 0.025-0.5 µg/mL, with a reasonably high correlation coefficient (0.9993). Furthermore, the method was very sensitive (LOQ, 0.006), accurate (RE, ≤7.06), and precise (%RSD, ≤6.51). After development and validation of the method, samples containing PL were analyzed with this method, and the obtained data were statistically compared with those obtained with a previously published reference method using a two one-sided equivalence test (TOST). According to the data, the results from the proposed and reference assays were equivalent.


Descreve-se método espectrofluorométrico para a determinação de losartana potássica (PL) em produtos farmacêuticos. Os efeitos de parâmetros críticos (pH, molaridade ácida e temperatura) na intensidade da fluorecência foram otimizados usando o planejamento de componente central (DCC). A mais alta intensidade fluorescente com λex=248 nm e λem= 410 nm foi obtida usando ácido sulfúrico 0.01 M (pH 2) e 21.6 ºC. Nas condições ideais, a linearidade do método foi estabelecida na faixa de concentração de 0.025-0.5 µg/mL com coeficiente de correlação bastante elevado (0.9993). Além disso, o método foi muito sensível com valor de LOQ 0.006, exato (RE≤7.06) e preciso (RSD%≤6.51). Depois do desenvolvimento e validação do método, amostras de medicamentos contendo PL foram analisadas com este método e os resultados obtidos foram comparados estatisticamente com método de referência, publicado anteriormente, usando o Teste de equivalência TOST (Teste de Equivalência Unilateral). De acordo com os dados estatísticos, os resultados do ensaio de referência e do método proposto foram equivalentes.


Asunto(s)
Espectrometría de Fluorescencia/métodos , Química Farmacéutica/métodos , Losartán/clasificación , Resinas Compuestas
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA