Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Añadir filtros








Intervalo de año
1.
Journal of the Korean Society for Surgery of the Hand ; : 202-207, 2017.
Artículo en Inglés | WPRIM | ID: wpr-177536

RESUMEN

Extensor tendon rupture is well known complication following distal radius fracture after either conservative treatment or volar plating. However, there are not many reports in literature about concomitant ruptures of other extensor tendons. We report a case of delayed rupture of extensor pollicis longus (EPL), second extensor digitorum communis (EDC II), and extensor indicis proprius (EIP) tendons 4 weeks after volar plating for distal radius fracture. Due to the absence of EIP, EIP transfer was discouraged for EPL reconstruction. Thumb and index finger extension was restored by palmaris longus tendon graft for EPL and EDC II.


Asunto(s)
Dedos , Fracturas del Radio , Radio (Anatomía) , Rotura , Tendones , Pulgar , Trasplantes