RESUMEN
Objective:To compare the surgical efficacy of pericardial soft ring tricuspid valvuloplasty with DeVega and artificial valvuloplasty.Methods:227 patients undergoing tricuspid valvuloplasty due to rheumatic heart disease complicated with functional tricuspid valve insufficiency were retrospectively analyzed and divided into 3 groups according to tricuspid valvuloplasty dynamic cohort(pericardial ring group, 89 cases; the artificial flap ring group, 61 cases, and the DeVega group, 77 cases) were matched 1∶1 for propensity score(match A: pericardial ring group and artificial flap ring group; match B: pericardial ring group and DeVega group), the successful matching was included in follow-up and data collection, and cases with incomplete case data during follow-up were removed from the study cohort in pairs according to matching conditions. The results of follow-up 1 month, 6 months and 24 months after surgery were compared.Results:1 month after operation: the tricuspid valve regurgitant in all groups was significantly reduced or even disappeared compared with that before operation, and the right atrium and right ventricle were also smaller than that before operation, with statistical significance( P<0.05). 6 months after surgery: There was no statistical significance in the area of tricuspid regurgitation and right atrial/indoor diameter between all groups compared with the results one month after surgery( P>0.05), and there was no statistical significance in the recurrence rate of tricuspid regurgitation between all groups( P>0.05). 24 months after surgery: There were no significant differences in the recurrence rate of tricuspid regurgitation, area of tricuspid regurgitation and right atrial/indoor diameter between the two groups in matching A( P>0.05). There was no statistical significance in the right atrial/indoor diameter between the matched pericardial ring group and the Devega group, but the tricuspid valve regurgentation area of the Devega group at 24 months after surgery was higher than that of the Devega group at 1 month after surgery, and the difference was statistically significant( P<0.05). The regurgitation area and recurrence rate of tricuspid valve were significantly higher than those of pericardium-TVP group( P<0.05). Conclusion:Pericardial soft ring tricuspid valvuloplasty can effectively correct functional tricuspid valvuloplasty and reverse right heart remodeling, which is an effective tricuspid valvuloplasty.
RESUMEN
@#Objective To investigate the effect of concomitant tricuspid valve repair during mitral valve surgery on the early and mid-term prognosis of the tricuspid valve and right heart function in the patients with moderate or less tricuspid regurgitation. Methods A retrospective study of 461 patients with mitral valve disease requiring cardiac surgery combined with moderate or less tricuspid regurgitation in our hospital from 2011 to 2014 was done. They were 309 males and 152 females with a median age of 53.00 (44.00, 60.00) years. According to whether they received tricuspid valve repair (Kay’s annuloplasty, DeVega’s annuloplasty or annular ring implantation), the patients were divided into a mitral valve surgery only group (a nTAP group, n=289) and a concomitant tricuspid valve repair group (a TAP group, n=172). At the same time, 43 patients whose tricuspid valve annulus diameter was less than 40 mm in the TAP group were analyzed in subgroups. Results The median follow-up duration was 3.00 years (range from 0.10 to 9.30 years). There was no perioperative death. Three months after surgery, the anteroposterior diameter of the right ventricle in the TAP group was significantly improved compared with that in the nTAP group [–1.00 (–3.00, 1.00) mm vs. 0.00 (–0.20, 2.00) mm, P=0.048]. Three years after surgery, the improvement of right ventricular anteroposterior diameter in the TAP group was still significant compared with the nTAP group [–1.00 (–2.75, 2.00) mm vs. 2.00 (–0.75, 4.00) mm, P=0.014], and the patients in the TAP group were less likely to develop moderate or more tricuspid regurgitation (3.64% vs. 35.64%, P<0.001). Annuloplasty ring implantation was more effective in preventing regurgitation progression (P=0.044). For patients with a tricuspid annulus diameter less than 40 mm, concomitant tricuspid valve repair was still effective in improving the anteroposterior diameter of the right ventricle in the early follow-up (P=0.036). Conclusion Concomitant tricuspid valve repair for patients with moderate or less tricuspid regurgitation during mitral valve surgery can effectively improve the tricuspid valve and right heart function in the early and mid-term after surgery. Annuloplasty ring implantation is more effective in preventing regurgitation progression. Patients whose tricuspid annulus diameter is less than 40 mm can also benefit from concomitant tricuspid repair.
RESUMEN
Objective:To comprehensively evaluate the tricuspid valve, right heart anatomical characteristics and related dynamic parameters in patients with different degrees of functional tricuspid regurgitation (FTR) using four-dimensional auto tricuspid valve quantitative(4D Auto TVQ), four-dimensional auto right ventricle quantitative(4D Auto RVQ), and four-dimensional auto left atrium quantitative(4D Auto LAQ), and to investigate the structural and functional changes of the tricuspid valve and right heart in them.Methods:Sixty-three patients with FTR diagnosed by echocardiography at the First Affiliated Hospital of Guangxi Medical University from February to July 2022 were prospectively selected as the case group, including 30 patients with mild FTR and 33 patients with moderate or above FTR, and 30 healthy subjects were selected as the control group. Transthoracic echocardiography was used for two-dimensional and three-dimensional image acquisition of the heart. The tricuspid regurgitation volume, left ventricular ejection fraction (LVEF), right ventricular global strain (RVGS) were measured by 2D images, and pulmonary artery systolic pressure (PASP) were measured from the tricuspid regurgitation pressure difference. The 3D images were imported into EchoPAC 204 to obtain the tricuspid valve, right heart structure and related dynamic parameters. The annulus area (AA), annulus perimeter(AP), spherical index (SI), annulus area change fraction (AC), coaptation point height (CPH), and tenting volume (TV) were measured by 4D Auto TVQ. The right atrial maximum volume (RAVmax) and right atrial minimum volume (RAVmin) were measured by 4D Auto LAQ. Right ventricular end-diastolic volume (RVEDV), right ventricular end-systolic volume (RVESV), right ventricular fractional area change (RVFAC) and tricuspid annular plane systolic excursion (TAPSE) were measured by 4D Auto RVQ. After standardizing the dimension parameters with body surface area (BSA), the differences in the above parameters were compared between the three groups, the correlation between regurgitant volume and each parameter was compared by correlation analysis, and the independent factors of increased tricuspid regurgitant volume were investigated by univariate and multivariate linear regression analysis.Results:There were statistically significant differences in PASP, AA/BSA, AP/BSA, AC, TV, RAVmax/BSA, RAVmin/BSA, RVFAC, RVGS, and TAPSE between the three groups (all P<0.05). There were statistically significant differences in LVEF, CPH, RVEDV/BSA, and RVESV/BSA in the moderate and above FTR group compared with the control and mild FTR groups (all P<0.05). Correlation analysis showed that RAVmin was the most highly correlated with tricuspid regurgitant volume ( r=0.875, P<0.001) and TV and end-systolic annulus area(ESAA) were highly correlated with tricuspid regurgitant volume ( r=0.747, 0.683; both P<0.001) in patients with FTR. Multifactorial linear regression showed that RAVmin, TV and regurgitant volume were independently positively correlated (β=0.721, 0.205; both P<0.05). Conclusions:The four quantification technique can provide valid structural and functional information by quantifying the tricuspid valve as well as the right heart in patients with FTR, and RAVmin and TV are independent correlates of increased tricuspid regurgitant volume.
RESUMEN
Objective:To explore the morphological parameters of tricuspid in patients with moderate or above functional tricuspid regurgitation (FTR ) by real-time three-dimensional (3D) transthoracic echocardiography.Methods:A total of 31 moderate or above FTR(FTR group) and 36 healthy adults(control group) were included in the study from May to July 2020 in the First Affiliated Hospital of Air Force Medical University (Xijing Hospital). Two-dimensional (2D) and 3D echoardiography were performed on both FTR group and control group. The 2D parameters included tricuspid regurgitation (TR), transverse diameter of right atrium/ ventricle, transverse diameter of tricuspid annulus(TVD), left ventricular ejection fraction (LVEF) and left ventricular fractional shortening (LVFS). The tricuspid 3D parameters were analyzed by TomTec software, including annular parameters[annular anterior-posterior diameter (AP), annular left-right diameter (AL-PM), sphericity index (SI=AP/AL-PM), non-planar angle (NPA), annulus circumference (AC), annulus area (AA), annulus height (AH)], leaflet parameters[tenting volume(TV), tenting area(TA), tenting heigh(TH), commissural diameter(CD)], and dynamic parameters[annular displacement max(ADmax), annulus area fraction(AAF)].Results:Compared with the control group, AP, AL-PM, SI, AC, AA, TV, TA parameters of FTR group were larger, ADmax was smaller (all P<0.05). Multiple linear regression model was used to evaluate the effects of RA, RV, AP, AL-PM, SI, TV, TA on FTR, and the results showed that FTR was associated with TV and TA( t=4.253, -2.14; all P<0.05). Conclusions:RT-3DE can be used to assess the morphological parameters of tricuspid valve with moderate or above FTR patients effectively. TV and TA are the two most important factors for moderate or above FTR.
RESUMEN
Objective:To investigate the mid-and long-term clinical effects of tricuspid valvuloplasty with the implantation of an artificial plastic ring.Methods:Data of 677 patients who had functional tricuspid regurgitation and left cardiac valve disease and underwent tricuspid valvuloplasty and left cardiac valve surgery were retrospectively. Among these patients, 353 underwent simple suture annuloplasty (group A) while the rest 324 patients underwent artificial plastic ring annuloplasty (group B). The two-year and more-than-two-year clinical and ultrasonocardiograph (UCG) follow-up data of the two groups were obtained and compared.Results:A total of 600 patients (88.6%) completed the long-term follow-up (more than two years). The two-year follow-up showed no significant difference in the incidence of mild tricuspid regurgitation between the two groups (82.2% vs. 92.7%, P=0.37). However, there were significantly more cases that developed into moderate to severe tricuspid regurgitation in group A than in group B (17.8% vs. 7.3%, P=0.031). The long-term follow-up revealed that the recurrence rate of tricuspid regurgitation in group B was significantly lower than that in group A (11.0% vs. 25.0%, P=0.029), and the ratio of cases developing into moderate to severe tricuspid regurgitation in group A was significantly higher than that in group B (28.9% vs. 9.9%, P=0.007). The comparison between the two intra-group time segments showed that the development of tricuspid regurgitation in group A was significantly increased (28.9% vs. 17.8%, P=0.022), but in group B it was relatively stable (9.9% vs. 7.3%, P=0.52).Conclusions:Artificial ring annuloplasty is associated with significantly less tricuspid regurgitation than simple suture annuloplasty.
RESUMEN
Objective: To investigate the mid-and long-term clinical effects of tricuspid valvuloplasty with the implantation of an artificial plastic ring. Methods: Data of 677 patients who had functional tricuspid regurgitation and left cardiac valve disease and underwent tricuspid valvuloplasty and left cardiac valve surgery were retrospectively. Among these patients, 353 underwent simple suture annuloplasty (group A) while the rest 324 patients underwent artificial plastic ring annuloplasty (group B). The two-year and more-than-two-year clinical and ultrasonocardiograph (UCG) follow-up data of the two groups were obtained and compared. Results: A total of 600 patients (88.6%) completed the long-term follow-up (more than two years). The two-year follow-up showed no significant difference in the incidence of mild tricuspid regurgitation between the two groups (82.2% vs. 92.7%, P=0.37). However, there were significantly more cases that developed into moderate to severe tricuspid regurgitation in group A than in group B (17.8% vs. 7.3%, P=0.031). The long-term follow-up revealed that the recurrence rate of tricuspid regurgitation in group B was significantly lower than that in group A (11.0% vs. 25.0%, P=0.029), and the ratio of cases developing into moderate to severe tricuspid regurgitation in group A was significantly higher than that in group B (28.9% vs. 9.9%, P=0.007). The comparison between the two intra-group time segments showed that the development of tricuspid regurgitation in group A was significantly increased (28.9% vs. 17.8%, P=0.022), but in group B it was relatively stable (9.9% vs. 7.3%, P=0.52). Conclusions: Artificial ring annuloplasty is associated with significantly less tricuspid regurgitation than simple suture annuloplasty.
RESUMEN
Objective To assess the morphological changes of tricuspid annulus in patients with functional tricuspid regurgitation(FTR)by real-time three-dimensional echocardiography.Methods Seventy-five FTR patients were divided into 4 groups according to the tricuspid regurgitation and transverse diameter of tricuspid annulus,which were group A(regurgitation more than moderate and dilated transverse diameter,n=21),group B(regurgitation less than moderate and dilated transverse diameter,n =18), group C(regurgitation more than moderate and normal transverse diameter,n = 1 9),group D (regurgitation less than moderate and normal transverse diameter,n =17).And 21 healthy controls were chosen to be group E.The 3D parameters including annular anterior-posterior diameter(AP),annular left-right diameter(SM),sphericity index(SI),non-planar angle(NPA),anterior annular length(Ant Ann), posterior annular length(Post Ann),annular circumference(Ann)and annular area(Area)were analyzed. Results SM,AP,Post Ann,Ann and Area of group A and B were larger than those in group E,whereas SI and Ant Ann only larger in group A(P<0.05).There were positive correlations between SM,AP,Post Ann,Ann,Area and the degree of regurgitation in group A(P <0.05).The patients of group C showed larger SM,Ant Ann,Post Ann,Ann and Area compared with patients in group E(P <0.05).There were no significant difference in all 3D parameters between group D and E(P >0.05).Conclusions FTR patients with regurgitation more than moderate or dilated transverse diameter are accompanied with changes of 3D annular parameters. The real-time three-dimensional echocardiography is helpful to judge morphological changes of tricuspid annulus in patients with FTR.
RESUMEN
Current knowledge of functional tricuspid regurgitation (FTR) as a progressive entity, worsening the prognosis of patients irrespective of its aetiology, has led to renewed interest in the pathophysiology and assessment of FTR. For the proper management of FTR, not only its severity, but also the mechanisms, the mode of leaflet coaptation, the degree of tricuspid annulus enlargement and leaflet tenting, and the haemodynamic consequences for right atrial and right ventricular morphology and function have to be taken into account. A better assessment of the anatomy and function of tricuspid apparatus and tricuspid regurgitation severity should help with the appropriate selection of patients who will benefit from either surgical tricuspid valve repair/replacement or a percutaneous procedure, especially among patients who are to undergo or have undergone primary left-sided valvular surgery. In this article, we review the anatomy, pathophysiology and the use of imaging techniques to assess patients with FTR, as well as the various treatment options for FTR, including emerging transcatheter procedures. The limitations affecting the current approach to FTR patients and the unmet clinical needs for their management have also been discussed.
Asunto(s)
Humanos , Diagnóstico , Ecocardiografía , Pronóstico , Válvula Tricúspide , Insuficiencia de la Válvula TricúspideRESUMEN
Current knowledge of functional tricuspid regurgitation (FTR) as a progressive entity, worsening the prognosis of patients irrespective of its aetiology, has led to renewed interest in the pathophysiology and assessment of FTR. For the proper management of FTR, not only its severity, but also the mechanisms, the mode of leaflet coaptation, the degree of tricuspid annulus enlargement and leaflet tenting, and the haemodynamic consequences for right atrial and right ventricular morphology and function have to be taken into account. A better assessment of the anatomy and function of tricuspid apparatus and tricuspid regurgitation severity should help with the appropriate selection of patients who will benefit from either surgical tricuspid valve repair/replacement or a percutaneous procedure, especially among patients who are to undergo or have undergone primary left-sided valvular surgery. In this article, we review the anatomy, pathophysiology and the use of imaging techniques to assess patients with FTR, as well as the various treatment options for FTR, including emerging transcatheter procedures. The limitations affecting the current approach to FTR patients and the unmet clinical needs for their management have also been discussed.