J. health med. sci. (Print) ; 7(4): 231-238, oct.-dic. 2021. ilus, tab
Artículo en Español | LILACS | ID: biblio-1391707

RESUMEN

To ensure a reliable verification of a radiation detector, the right parameters for this response verification must be determined and a specific characterization on the detectors of interest must be performed. These were the main pillars of this study, where four Geiger-Müller at the University of Costa Rica's Cyclotron Facilities' main laboratories were studied and characterized using a 137Cs source. First, a verification of the inverse-square law was performed to corroborate the correct measurement by the detectors as the distance from a 137Cs source to the detectors was varied using a new design for a positioner support to ensure repeatability. This verification yielded a potential fit curve with and equation D=670635 x-1.961 (error percentage of 1.95%) and an R2 value of 0.9836. Then, using combinations of copper plates of widths 1.0 mm and 2.0 mm as attenuators between the source and the detectors, the mass attenuation coefficient for copper was obtained only as a reference value for future calibrations of the detectors. The result for this value was 0.040 cm2 /g. The results obtained in this study and the method developed to achieve these results will serve as a base for calibrations of the detectors at these facilities, which will ensure the safety of the patients and personnel in this building.


Para asegurar respuesta correcta de un detector de radiación, se deben determinar los parámetros correctos para esta verificación y debe realizarse una caracterización específica de los detectores de interés. Estos fueron los pilares principales de este estudio, donde se estudiaron y caracterizaron 4 detectores Geiger-Müller en los laboratorios principales del Ciclotrón de la Universidad de Costa Rica utilizando una fuente radiactiva de 137Cs. Primero, se realizó una verificación de la ley del inverso-cuadrado para corroborar la medición correcta de los detectores según se varía la distancia entre la fuente de 137Cs al detector utilizando un diseño nuevo de un soporte posicionador para la fuente que asegura la repetibilidad entre experimentos. Esta verificación resultó en una curva de ajuste potencial de ecuación D=670635x-1,961 (porcentaje de error de 1,95%) y un valor de R2 de 0,9836. Luego, utilizando combinaciones de placas de cobre de espesores 1,0 mm y 2,0 mm como atenuadores entre la fuente y los detectores, se obtuvo el coeficiente de atenuación másico para el cobre como un valor de referencia para futuras calibraciones de los detectores. Este resultado fue de 0,040 cm2/g. Los resultados obtenidos en esta investigación y el método desarrollado para lograr estos resultados servirán como una base para una futura confirmación metrológica calibraciones de los detectores en estos laboratorios, lo cual colaborará con la seguridad y protección radiológica de pacientes y trabajadores en este edificio.


Asunto(s)
Monitoreo de Radiación/instrumentación , Monitoreo de Radiación/métodos , Radiometría/instrumentación , Radiometría/métodos , Universidades , Calibración , Radioisótopos de Cesio , Ciclotrones , Exposición a la Radiación/análisis , Exposición a la Radiación/prevención & control , Costa Rica
2.
Artículo | IMSEAR | ID: sea-183765

RESUMEN

Assuming that n patients in surgical or maternity wards are admitted T days (T = 0, 1, 2 … n) prior to the date of surgery or delivery for clinical check-up, an attempt has been made to develop the best appropriate probability model on Geiger–Muller counter type-II, to describe the arrival of patients and the busy (locked) period in the hospital. The problem is further extended to obtain optimal solution loading to (a) uniform type of medical care and (b) for providing medical care for a maximum period depending on the complications on an average, subject to the fixed budget of the hospital.

3.
Nucleus (La Habana) ; (61): 39-43, Jan.-June 2017.
Artículo en Español | LILACS | ID: biblio-841909

RESUMEN

En el presente trabajo se describe el desarrollo de un instrumento para el monitoreo radiológico identificado como Alarma Gamma (GAMAL01). Estos monitores detectan el incremento de la tasa de conteo de la radiación y emiten una alarma cuando esta magnitud sobrepasa un umbral determinado. El umbral para la emisión de la alarma se fija de manera que esta se produzca cuando se considere que la tasa de conteo de la radiación pueda provocar una exposición inaceptable del personal a las radiaciones, de acuerdo a lo establecido por las normas de seguridad radiológica vigentes en el país. La señal de alarma indica la necesidad de realizar la evacuación del personal del sitio afectado. El instrumento consta de dos secciones: una analógica y otra digital


This paper describes the development of an instrument for radiological monitoring, identified as Gamma Alarm (GAMAL01). The instrument monitors the increment of radiation count rate and produces an alarm signal, when the count rate becomes superior to a fixed threshold value. The threshold is fixed to assure that the signal emission will start when the value of the radiation count rate may cause a non acceptable radiological exposition of the personnel, according to the radiological safety regulations existing in the country. Following the signal the personnel must be evacuated from the affected place. The instrument consists of two sections, an analogical section and a digital one