Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 421
Filtrar
1.
Odovtos (En línea) ; 26(1): 65-75, Jan.-Apr. 2024. tab
Artículo en Inglés | LILACS, SaludCR | ID: biblio-1558619

RESUMEN

Abstract This research evaluates the presence of the oxygen-inhibited layer (OIL) on the top surface of a photopolymerized dental composite resin protected with a glycerin layer. This evaluation was conducted using physical and mathematical methods. Polymerized discs were fabricated to evaluate Vickers microhardness (VHN), and pre-and post-polymerized samples were used for the calculation of C-O/C-H ratios through Fourier Transform Infrared Spectroscopy (FTIR) (n=10), using two types of glycerin, one for medical use (MG) and another for dental use (DG). Surface hardness decreased from MG to DG to CO, and the increase in C-O/C-H ratios decreased in the same order (p<0.05). Samples protected with medical and dental glycerin layers are harder and exhibit lower C-O/C-H bond ratios than the control group.


Resumen La presente investigación evalúa la presencia de la capa inhibida por oxígeno OIL en la última superficie fotocurada de una resina compuesta de uso odontológica que fue protegida con una capa de glicerina. Esta evaluación se hizo a partir de métodos físicos y matemáticos. Se fabricaron discos polimerizados para evaluar la microdureza Vickers (VHN) y pre y post polimerizados para el cálculo de tasas C-O/C-H por medio de Espectroscopía Infrarroja Transformada de Fourier (FTIR) (n=10) usando dos tipos de glicerina, una de uso médico (MG) y otra de uso dental (DG). La dureza superficial disminuyó de MG a DG a CO y el aumento de tasas C-O/C-H disminuyó en ese mismo orden (p<0,05). Las muestras protegidas con capas de glicerina médica y odontológica son más duras y presentan menos cantidad tasas de enlaces C-O/C-H que el grupo control.


Asunto(s)
Resinas Compuestas/análisis , Glicerol/análisis , Polímeros , Espectroscopía Infrarroja por Transformada de Fourier , Pruebas de Dureza
2.
J. health sci. (Londrina) ; 26(1): 09-16, 20240329.
Artículo en Inglés | LILACS-Express | LILACS | ID: biblio-1563052

RESUMEN

Endocrowns have emerged as a promising option for restoring endodontically treated teeth, offeringa restorable fracture scenario. However, regarding the choice of material and its fracture resistance, there are gaps in the literature regarding the best indication. The objective of this research was to evaluate and compare the effect of restorative materials for CAD-CAM in the manufacture of endocrown restorations, through an in Vitro study on hardness and fracture resistance. For the study, CAD-CAM blocks were transformed into discs 12 mm in diameter and 1.2 mm thick (specimens). Three restorative materials were evaluated and distributed into experimental groups (N=12 specimens): Leucita- Reinforced Ceramic/ IPS Empress CAD (MRleu), Lithium Disilicate/ IPS Emax CAD (MRdis) and Nanoceramic Resin /Lava Ultimate (MRres). These restorative materials were evaluated for morphology (N=1) by Scanning Electron Microscopy (SEM) and surface chemistry (N=1) by dispersive energy spectroscopy (EDS). The specimens were evaluated when the Vikers micro hardness (N=1) with a load of 1kg and 10 indentations, as well as the resistance to biaxial flexion (N=10) at a test speed of 0.5 mm/min. After the fracture occurred, the fragments were examined under a stereomicroscope. The results were tabulated and analyzed using the Minitab statistical program. The results showed that the MRdis material demonstrated superior results in relation to hardness (P=0.000) and biaxial bending resistance (P=0.000), followed by MRleu and finally the MRres. The presence of inorganic particles on an organic matrix and the presence of Zirconium (Zr) stands out in Lava Ultimate. It was concluded that restorative materials for CAD-CAM in the manufacture of Endocrowns restorations have a significant effect on hardness and mechanical strength.Endocrowns have emerged as a promising option for restoring endodontically treated teeth, offeringa restorable fracture scenario. However, regarding the choice of material and its fracture resistance, there are gaps in the literature regarding the best indication. The objective of this research was to evaluate and compare the effect of restorative materials for CAD-CAM in the manufacture of endocrown restorations, through an in Vitro study on hardness and fracture resistance. For the study, CAD-CAM blocks were transformed into discs 12 mm in diameter and 1.2 mm thick (specimens). Three restorative materials were evaluated and distributed into experimental groups (N=12 specimens): Leucita- Reinforced Ceramic/ IPS Empress CAD (MRleu), Lithium Disilicate/ IPS Emax CAD (MRdis) and Nanoceramic Resin /Lava Ultimate (MRres). These restorative materials were evaluated for morphology (N=1) by Scanning Electron Microscopy (SEM) and surface chemistry (N=1) by dispersive energy spectroscopy (EDS). The specimens were evaluated when the Vikers micro hardness (N=1) with a load of 1kg and 10 indentations, as well as the resistance to biaxial flexion (N=10) at a test speed of 0.5 mm/min. After the fracture occurred, the fragments were examined under a stereomicroscope. The results were tabulated and analyzed using the Minitab statistical program. The results showed that the MRdis material demonstrated superior results in relation to hardness (P=0.000) and biaxial bending resistance (P=0.000), followed by MRleu and finally the MRres. The presence of inorganic particles on an organic matrix and the presence of Zirconium (Zr) stands out in Lava Ultimate. It was concluded that restorative materials for CAD-CAM in the manufacture of Endocrowns restorations have a significant effect on hardness and mechanical strength. (AU)


As endocrowns surgiram como uma alternativa favorável para a restauração de dentes tratados endodonticamente, e se apresentam em um cenário de fratura restaurável. No entanto, em relação ao material de escolha e sua resistência à fratura existem lacunas na literature sobre a melhor indicação. O objetivo dessa pesquisa foi avaliar e comparar o efeito de materiais restauradores para CAD-CAM na confecção de restaurações endocrowns, através de um estudo in vitro sobre dureza e resistência à fratura. Para realização do estudo, blocos para CAD-CAM foram transformados em discos com 12 mm de diâmetro e 1,2 mm de espessura (espécimes). Três materiais restauradores foram avaliados e distribuídos em grupos experimentais (N=12 espécimes): Cerâmica Reforçada por Leucita/ IPS Empress CAD (MRleu), Dissilicato de Lítio/ IPS Emax CAD (MRdis) e Resina Nanocerâmica /Lava Ultimate (MRres). Estes materiais restauradores foram avaliados quanto à morfologia (N=1) através de Microscopia Eletrônica de Varredura (MEV) e química superficial (N=1) pela Espectroscopia de energia dispersiva (EDS). Os espécimes foram avaliados quanto à microdureza Vikers (N=1) com uma carga de 1kg e 10 indentações, como também em relação a resistência à flexão biaxial (N=10) em uma velocidade de ensaio de 0,5 mm/min. Os fragmentos após a fratura foram observados em estereomicroscópio. Os dados obtidos foram tabulados e analisados no programa estatístico Minitab. Os resultados observados mostraram que o material MRdis obteve resultados superiores em relação a dureza (P=0,000) e a resistência à flexão biaxial (P=0,000), seguido pelo MRleu e por fim o MRres. Destaca-se na Lava Ultimate a presença de partículas inorgânicas sobre uma matriz orgânica, além da presença de Zircônio (Zr). Conclui-se que materiais restauradores para CAD-CAM na confecção de restaurações Endocrowns apresentam efeito significativo quanto a dureza e resistência mecânica. (AU)

3.
Rev. estomatol. Hered ; 34(1): 7-16, ene.-mar. 2024. tab, graf
Artículo en Español | LILACS-Express | LILACS | ID: biblio-1565539

RESUMEN

RESUMEN Objetivo : Comparar la microdureza de la resina compuesta con técnica índex convencional y modificada con cubeta impresa en dos fotopolimerizaciones. Materiales y métodos : Se contó con seis grupos de estudio de acuerdo a la técnica y a la cantidad de fotopolimerizaciones: técnica directa con una fotopolimerización (D1F), directa con dos fotopolimerizaciones (D2F), índex convencional con una fotopolimerización (IC1F), índex convencional con dos fotopolimerizaciones (IC2F), índex modificada con una fotopolimerización (IM1F), índex modificada con dos fotopolimerizaciones (IM2F). Se utilizaron quince muestras por cada grupo. Las muestras tuvieron dimensiones de 2 mm de altura por 5 mm de diámetro. Se realizó la fotopolimerización siguiendo las indicaciones del grupo al que corresponde, para luego someter a la prueba de dureza de Vickers a tres indentaciones por cada cara con carga de 200 g por 15 segundos. Se realizaron dos registros de microdureza, una superficial y otra a 2 mm. Se recolectaron los datos en el instrumento confeccionado y fueron procesados mediante SPSS v. 26. Resultados : Existe una diferencia significativa entre los grupos de microdureza superficial de primera fotopolimerización (p < 0,001); y también existe diferencia significativa entre los grupos de microdureza a 2 mm de primera fotopolimerización (p < 0,001). Asimismo, no existen diferencias significativas entre los grupos de microdureza superficial de segunda fotopolimerización (p = 0,519) ni en los grupos de microdureza a 2 mm de segunda fotopolimerización (p = 0,279). Conclusiones: No existen diferencias significativas en la microdureza superficial y a 2 mm de profundidad con técnica índex convencional y modificada en cubeta impresa en dos fotopolimerizaciones.


ABSTRACT Objective : To compare the microhardness of composite resin with conventional and modified index techniques with a printed tray in two light cures. Materials and methods : There were six study groups according to the technique and the number of photopolymerizations: direct technique with one photopolymerization (D1F), direct with two photopolymerizations (D2F), conventional index with one photopolymerization (IC1F), conventional index with two photopolymerizations (IC2F), modified index with one photopolymerization (IM1F), modified index with two photopolymerizations (IM2F). Fifteen samples were used for each group. The samples had dimensions of 2 mm in height by 5 mm in diameter. The photopolymerization was performed following the indications of the group to which it corresponds and then subjected to the Vickers hardness test with three indentations on each side with a load of 200 g for 15 seconds. Two microhardness recordings were made, one superficial and the other at 2 mm. Results : There is a significant difference between the first light-curing surface microhardness groups (p < 0.001), and there is also a significant difference between the first light-curing 2 mm microhardness groups (p < 0.001). Likewise, there are no significant differences between the second light-curing surface microhardness groups (p = 0.519) or the second light-curing 2 mm microhardness groups (p = 0.279). Conclusions : There are no significant differences in surface microhardness and microhardness at 2 mm depth with conventional and modified index techniques in printed trays in two photopolymerizations.


RESUMO Objetivo : Comparar a microdureza da resina composta com a técnica de índice convencional e modificada com moldeira impressa em duas fotopolimerizações. Materiais e métodos : Foram constituídos seis grupos de estudo de acordo com a técnica e o número de ciclos de fotopolimerização: técnica direta com um ciclo de fotopolimerização (D1F), direta com dois ciclos de fotopolimerização (D2F), índice convencional com um ciclo de fotopolimerização (IC1F), índice convencional com dois ciclos de fotopolimerização (IC2F), índice modificado com um ciclo de fotopolimerização (IM1F), índice modificado com dois ciclos de fotopolimerização (IM2F). Foram utilizadas quinze amostras para cada grupo. Os espécimes tinham 2 mm de altura por 5 mm de diâmetro. A fotopolimerização foi efetuada de acordo com as indicações do grupo a que corresponde, e depois submetida ao teste de dureza Vickers com três indentações de cada lado com uma carga de 200 g durante 15 segundos. Foram efetuados dois registos de microdureza, um superficial e outro a 2 mm. Os dados foram recolhidos no instrumento e processados utilizando o SPSS v. 26. Resultados : Há uma diferença significativa entre os primeiros grupos de microdureza superficial fotopolimerizável (p < 0,001); e há também uma diferença significativa entre os primeiros grupos de microdureza de 2 mm fotopolimerizável (p < 0,001). Da mesma forma, não há diferença significativa entre os grupos de microdureza da superfície do segundo fotopolimerizador (p = 0,519) e nos grupos de microdureza de 2 mm do segundo fotopolimerizador (p = 0,279). Conclusões : Não existem diferenças significativas na microdureza da superfície e na microdureza a 2 mm de profundidade com a técnica de índice convencional e modificada em duas fotopolimerizações.

4.
Artículo en Chino | WPRIM | ID: wpr-1018419

RESUMEN

Objective To systematically evaluate the clinical efficacy of the prescriptions for softening hardness to dissipate mass combined with Levothyroxine Sodium in the treatment of postoperative thyroid cancer,and to provide evidence-based medical proof for clinical treatment of postoperative thyroid cancer.Methods Computer search was performed in the major domestic and oversea databases for the retrieval of clinical randomized controlled trials(RCTs)of prescriptions for softening hardness to dissipate mass combined with Levothyroxine Sodium for the treatment of postoperative thyroid cancer.After screening the literature according to the inclusion and exclusion criteria,the quality of the included literature was evaluated using the tools for analysis of the bias recommended by Cochrane Reviewer's Handbook and the modified JADAD rating scale,and meta-analysis was performed using RevMan 5.4 software.Results A total of 11 RCTs involving 749 patients were eventually included.The results of meta-analysis showed that compared with Levothyroxine Sodium alone,prescriptions for softening hardness to dissipate mass combined with Levothyroxine Sodium significantly enhanced the efficacy of postoperative patients with thyroid cancer(RR=1.30,95%CI[1.21,1.41],Z = 6.81,P<0.000 01),and improved the thyroid functions parameters of serum thyroid stimulating hormone(TSH)(SMD=-1.75,95%CI[-2.38,-1.13],Z = 5.47,P<0.000 01),thyroglobulin(TG)(SMD=-1.13,95%CI[-1.71,-0.55],Z = 3.81,P = 0.000 1),free triiodothyronine(FT3)(SMD=3.42,95%CI[0.73,6.10],Z = 2.50,P = 0.01),free thyroxine(FT4)(SMD=1.85,95%CI[0.05,3.66],Z = 2.02,P = 0.04),and thyroglobulin antibody(TgAb)(SMD=-0.63,95%CI[-1.11,-0.15],Z = 2.55,P = 0.01),increased Karnofsky Performance Status(KPS)scores(SMD= 2.19,95%CI[1.30,3.08],Z = 4.81,P<0.000 01),shortened the time for the relief of clinical symptoms after thyroid cancer surgery(MD=-4.67,95%CI[-5.38,-3.96],Z = 12.87,P<0.000 01),reduced the diameter of the largest thyroid nodule after thyroid cancer surgery(MD=-2.51,95%CI[-3.13,-1.89],Z = 7.94,P<0.000 01),regulated the immune function indicators of T lymphocyte population CD3+(MD=8.68,95%CI[4.97,12.39],Z = 4.59,P<0.000 01)and CD4+(MD=10.77,95%CI[5.46,16.08],Z = 3.97,P<0.000 1)levels,and reduced the incidence of postoperative complications of thyroid cancer(RR=0.34,95%CI[0.18,0.65],Z = 3.26,P = 0.001).The differences were all statistically significant(P<0.05).Conclusion prescriptions for softening hardness to dissipate mass combined with Levothyroxine Sodium can enhance the efficacy of postoperative patients with thyroid cancer.The combined therapy is superior to Levothyroxine Sodium alone in improving thyroid function indicators,KPS score,time for the relief of clinical symptoms,diameter of the largest thyroid nodule,immune function indicators,and the incidence of postoperative complications.However,due to the small amount of included trials and the fact that the prescriptions for softening hardness to dissipate mass vary in the composition,the conclusions of the analysis need to be confirmed by more high-quality,multi-center,large-sample clinically randomized controlled trials.

5.
Artículo en Chino | WPRIM | ID: wpr-1021222

RESUMEN

BACKGROUND:There are increasing scientific and technological ways to promote the recovery of muscle fatigue after sports,such as vibrating foam shaft,fascia gun relaxation,and ultra-low temperature cold therapy.Fascia gun relaxation has been widely used in practice,but there is still relatively little research on fascial guns. OBJECTIVE:To compare the effects of three relaxation methods(fascia gun,stretching,fascia gun+stretching)on muscle status and muscle strength during the recovery of exercise-induced muscle fatigue,and to provide scientific basis for the application of the three methods in practice. METHODS:Forty college students were randomly divided into control group(n=10),stretching group(n=10),fascia gun group(n=10),and fascia gun+stretching group(n=10).All subjects completed leg flexion and extension training at 60%1 RM,15 times per set,for 10 sets in total,to make exercise fatigue models.After modeling,the subjects were intervened with supine rest,static stretching,fascia gun relaxation,fascia gun+stretching relaxation respectively.Muscle status and muscle strength indexes were tested before exercise,immediately after exercise,immediately after relaxation,24 and 48 hours after exercise. RESULTS AND CONCLUSION:The muscle tension and dynamic hardness of the control group and the stretching group immediately after relaxation were significantly higher than those before training(P<0.01).However,there was no significant difference in the fascia gun group and fascia gun+stretching group before and after training(P>0.05).At 24 hours after training,the peak torque of the control group and fascia gun group was significantly lower than that before training(P<0.01),and there was no significant difference in the stretching group and fascia gun+stretching group before and 24 hours after training(P>0.05).To conclude,the fascia gun can immediately and effectively improve the muscle state of sports fatigue and stretching can promote the effective recovery of muscle strength within 24 hours after sports fatigue.Relaxation using fascia gun plus stretching can achieve the superposition of the two effects.

6.
Artículo en Chino | WPRIM | ID: wpr-1036494

RESUMEN

Objective To study the effects of different pellet feed hardness on the growth and reproduction, feed utilization rate, and environmental dust in laboratory mice.Methods One hundred of fifty 50 3-week-old SPF-grade C57BL/6JGpt and 150 ICR laboratory mice were randomly divided into three groups, with an equal number of males and females. They were fed diets with different hardness of 18.62 kg, 23.15 kg, and 27.89 kg. Body weight, feed utilization rate, and dust levels in cages were recorded and calculated for mice aged 3-10 weeks. Forty-five 6-week-old male mice and ninety 4-week-old female mice from each strain were randomly divided into three groups and fed pellet feeds with three different hardness levels. After 2 weeks of adaptation to the same hardness feed, the mice were paired at a 1∶2 male-to-female ratio and monitored for reproductive data for 3 months.Results At the age of 4 weeks, the body weight of male C57BL/6JGpt mice in 23.15 kg group was significantly higher than that in the 18.62 kg and 27.89 kg groups (P<0.01), and the body weight of females in the 18.62 kg group was significantly higher than that in the 27.89 kg group (P<0.05). There was no significant difference in body weight among ICR mice aged 3-10 weeks across different feed hardness groups (P>0.05). For both strains, feed utilization rate for males was higher than that for females across different feed hardness groups at all weeks of age (P<0.01). Compared to the 27.89 kg group, both the 18.62 kg and 23.15 kg groups showed a significant increase in the 50-mesh dust levels in cages for both strains aged 4-8 weeks (except for 7-week-old C57BL/6JGpt mice) (P<0.05). For both C57BL/6JGpt and ICR mice, there was no significant difference in basic reproductive performance such as interval between the first litter and the monthly production index among the three feed hardness groups during the experimental period (P>0.05). However, the monthly production index of C57BL/6JGpt mice first increased and then decreased with the increase of feed hardness, while that of ICR mice increased with increasing feed hardness, though these differences were not statistically significant (P>0.05).Conclusion Different strains and genders had different tolerance to feed hardness. C57BL/6JGpt mice are more adapted to lower hardness feeds, while ICR mice are better suited to slightly higher hardness feeds.

7.
Artículo en Chino | WPRIM | ID: wpr-1024519

RESUMEN

Objective To explore the influence of different hardness surfaces on gait coordination in patients with functional ankle instability(FAI). Methods Qualisys Infrared Optical Motion Capture System was used to test the coordination and variability of 15 FAI patients on the right side at Nanjing Normal University from May to July,2023.The gait cycle data were collect-ed and intercepted,and coupling angle(CA)and standard deviation of coupling angle(SDCA)were calculated by Matlab to compare the differences on different hardness surfaces. Results On coronal plane,CA of hip-ankle joint was higher on the hard surface than on the soft surface during middle stage of support and early stage of swing,and lower on its rest stages and the gait stages of hip-knee joint and knee-ankle joint than on the soft surface(P<0.01).On sagittal plane,CA of hip-ankle joint and knee-ankle joint was smaller on the hard surface than on the soft surface during middle and late stages of support,and larger than on the soft surface during their rest stages,and the gait stages of hip-knee joint(P<0.01).On horizontal plane,CA of hip-knee joint was lower on the hard surface than on the soft surface during the late stage of support,and higher than on the soft surface during its early stage of swing and bearing stage of hip-ankle joint(P<0.01).Compared with the hard surface,SDCA was smaller on the soft surface than on the hard surface only in the hip-ankle on the sagittal plane and during bearing stage of hip-knee joint,and was greater than on the hard surface for the rest(P<0.01). Conclusion FAI patients showed more distal dominance on soft surface than on hard surface during most gait cycle on 3D plane,i.e.,advantage of ankle varus and plantar flexion increased,and advantage of hip joint decreased;the coordination variability was generally higher on soft surface than on hard surface.These findings suggested that FAI patients may increase the risk of recurrent lateral ankle sprain walking on soft surface.

8.
China Medical Equipment ; (12): 88-92, 2024.
Artículo en Chino | WPRIM | ID: wpr-1026452

RESUMEN

Objective:To investigate the values of ultrasound elasticity(UE)imaging and color Doppler flow energy(CDFI)in differential diagnosis for triple negative breast cancer(TNBC)and fibroadenoma.Methods:A total of 50 TNBC patients who admitted to People's Hospital of Wanning from January 2021 to January 2022 and were confirmed by surgical pathology were selected,and they were divided into TNBC group.On the other hand,a total of 50 patients with fibroadenoma who were confirmed by surgical pathology during the same period were selected and they were divided into fibroadenoma group.All patients did not undergo any clinical intervention before ultrasound examination.UE and CDFI were used respectively to evaluate the degrees of softness and hardness of the tissues,the color blood flow and elasticity scores of lesions.The pathological result was used as the gold standard to analyze respectively the diagnostic efficacies of UE and CDFI for TNBC and fibroadenoma.Results:According to the characteristics of ultrasound imaging,the TNBC group mostly showed burr sign on lesion edge,the attenuation and hyperechoic halo of posterior echo,and existing axillary lymph node metastasis.The fibroadenoma group mostly showed clear boundaries of lesion area,regular lesion morphology,non-microcalcification.The diagnostic sensitivity,specificity and accuracy of UE detection were respectively 90.91%,82.14%and 86.00%,while these indicators of CDFI were respectively 73.08%,75.00%and 74.00%.In addition,the sensitivity,specificity and accuracy of the combined detection of them were respectively 94.23%,95.83%and 96.00%.The detection efficiency of the combined detection was higher than that of each single detection.Conclusion:UE has higher sensitivity in the differential diagnosis of TNBC and fibroadenoma,but it's specificity is not high.The combined detection of UE and CDFI can improve the specificity and accuracy of differential diagnosis.

9.
Braz. oral res. (Online) ; 38: e062, 2024. tab, graf
Artículo en Inglés | LILACS-Express | LILACS, BBO | ID: biblio-1564197

RESUMEN

Abstract This study investigated the impact of 'storage condition' and 'period of storage' on selected physico-mechanical properties and fracture reliability of a resin-based composite (RBC). Specimens, prepared from a nanofilled RBC (Filtek Z350 XT; 3M ESPE), underwent tests for degree of conversion (DC), flexural strength (σ), flexural modulus (E), and hardness. The specimens were initially grouped into dry storage at 37°C or wet storage in distilled water at 37°C. Subsequently, they were further divided into four subgroups based on the period of storage: 6, 24, 72, or 168 hours. Specimens tested immediately after preparation served as control. Data analysis employed two-way ANOVA and Weibull analysis (α = 5%). Compared to the control, an increase in DC was observed only after 72 hours of dry storage; σ showed higher values after both dry and wet storage, regardless of the storage period (except for the group wet-stored for 168 hours); E increased with dry storage for at least 24 hours or wet storage for 72 hours; and hardness increased after dry storage for at least 24 hours or wet storage for up to 72 hours. The Weibull modulus remained unchanged under any of the distinct storage conditions. Dry storage resulted in greater characteristic strength than the control, whereas wet storage contributed to higher strength values only at shorter periods (up to 24 hours). Overall, the inherent properties of RBCs with a similar composition to that tested in this study may change with varying storage conditions and periods.

10.
Braz. oral res. (Online) ; 38: e030, 2024. tab, graf
Artículo en Inglés | LILACS-Express | LILACS, BBO | ID: biblio-1557363

RESUMEN

Abstract This study aimed to evaluate volumetric polymerization shrinkage, degree of conversion and Vickers hardness of four bulk-fill resin composites light-activated with their dedicated light curing units (LCUs). Four groups were evaluated, according to the type of composite and curing mode: Tetric EvoCeram Bulk-fill (TEBO) and Tetric EvoFlow Bulk-fill (TEBF) were light-activated with Bluephase Style 20i (20s, in high-mode), while Tetric Powerfill (TEPO) and Tetric Powerflow (TEPF) were light-activated with Bluephase PowerCure (3s). Volumetric polymerization shrinkage test (n = 6) was performed in standardized box-shaped class-I cavities of extracted third molars (4 x 4 x 4 mm). Teeth were scanned before and after resin composite application by micro-computed tomography, and acquired data were evaluated with Amira software. Degree of conversion (n = 5) was evaluated at the top and bottom surfaces of composite cylindric samples (4 mm diameter, 4 mm thickness) using an FT-IR spectrometer (spectra between 1,500 and 1,800 cm-1, 40 scans at a resolution of 4 cm-1). Three Vickers indentations (50 g / 15 s), spaced 500 μm apart, were performed on the top and bottom composite surfaces and averaged. One-way ANOVA was used for data evaluation. TEPF showed the lowest volumetric polymerization shrinkage (p < 0.05), while the other composites were not significantly different within each other (p > 0.05). All materials presented a significant decrease in degree of conversion and Vickers hardness when compared top to bottom surfaces (p < 0.05). Bottom to top surface ratios for degree of conversion ranged from 0.8 (TEBO and TEPO) to 0.9 (TEBF and TEPF), and from 0.4 (TEPO) to 0.7 (TEBF and TEPF) for hardness. In conclusion, resinous materials present a decrease in hardness and degree of conversion from top to bottom even when a higher power is used, while the flowable material TEPF showed the lowest volumetric shrinkage values compared to the other materials.

11.
Braz. oral res. (Online) ; 38: e036, 2024. tab, graf
Artículo en Inglés | LILACS-Express | LILACS, BBO | ID: biblio-1557370

RESUMEN

Abstract This study aimed to evaluate in vitro the effect protocols and anticaries agents containing casein amorphous calcium fluoride phosphopeptide-phosphate (CPP-ACPF, MI Paste Plus), sodium trimetaphosphate (TMP) and fluoride (F), in remineralization of caries lesions. Bovine enamel blocks with initial caries lesions were divided into groups (n = 12): 1) Toothpaste without F-TMP-MI Plus (Placebo); 2) Toothpaste 1100 ppm F (1100F), 3) 1100F + MI Paste Plus (1100F-MI Paste Plus), 4) Toothpaste with 1100F + Neutral gel with 4,500 ppm F + 5%TMP (1100F + Gel TMP) and 5) Toothpaste with 1100F + Neutral gel with 9,000 ppm F (1100F + Gel F). For the 4 and 5 groups the gel was applied only once for 1 minute, initially to the study. For the 3 group, after treatment with 1100F, MI Paste Plus was applied 2x/day for 3 minute. After pH cycling, the percentage of surface hardness recovery (%SHR); integrated loss of subsurface hardness (ΔKHN); profile and depth of the subsuperficial lesion (PLM); concentrations of F, calcium (Ca) and phosphorus (P) in enamel was determined. The data were analyzed by ANOVA (1-criterion) and Student-Newman-Keuls test (p < 0.001). Treatment with 1100F alone led to ~ 28% higher remineralization when compared to treatment with 1100F associated with MI Paste Plus (p < 0.001). The 1100F and 1100F + Gel F groups showed similar values for %SHR (p = 0.150). 1100F + Gel TMP treatment also remineralized the enamel surface by ~ 30% and 20% when compared to the 1100F + Gel F and 1100F groups (p < 0.001). The lower lesion depth (ΔKHN) was observed for the 1100F + Gel TMP group (p < 0.001), where it was 54% and 44% lower in comparison to the 1100F and 1100F + Gel F groups (p < 0.001). Polarized light microscopy photomicrographs showed subsurface lesions in all groups, but these lesions were present to a lower extent in the 1100F + Gel TMP group (p < 0.001). Treatment with 1100F + Gel TMP promoted an increase in the concentration of Ca in the enamel by ~ 57% and ~ 26% when compared to the 1100F and 1100F + MI Paste Plus groups (p < 0.001), respectively. There were no significant differences between the 1100F, 1100F + MI Paste Plus and 1100F + Gel F groups (p > 0.001). Similar values of P in the enamel were observed in the 1100F, 1100F + MI Paste Plus and 1100F + Gel F groups (p > 0.001), except for the 1100F + Gel TMP group, which presented a high concentration (p < 0.001). We conclude that the 1100F+TMP gel treatment/protocol led to a significant increased remineralization when compared to the other treatments/protocols and may be a promising strategy for patients with early caries lesions.

12.
Braz. j. oral sci ; 23: e240398, 2024. tab
Artículo en Inglés | LILACS, BBO | ID: biblio-1553456

RESUMEN

Aim: This study aimed to assess the polymerization effectiveness of bulk-fill composite resins in longitudinal microhardness. Methods: Blocks of bulk-fill composite resin with thicknesses of 6 mm were analyzed with Vickers microhardness. The resin blocks were divided into two groups (n=6): resin AURA and OPUS. The microhardness test was performed before (base and top) and after (longitudinal microhardness) sectioning the blocks at distances of 2 mm, 4 mm, and 6 mm from the top of the block. The mean microhardness values were tabulated and subjected to ANOVA followed by Tukey's test (p<0.05). Results: The OPUS bulk-fill resin samples presented microhardness means of 55.9 kgf/mm2, 53.7 kgf/mm2, and 49.3 kgf/mm2, the AURA bulk-fill resin samples presented microhardness means of 57,02 kgf/mm2, 55,86 kgf/mm2 e 51,77 kgf/mm2 for the distances of 2 mm, 4 mm, and 6 mm, respectively. Tukey's statistical test showed a significant difference in microhardness values at different distances of 2 mm, 4 mm, and 6 mm (p<0.001) for each resin. Although there was a statistically significant difference within and between the groups assessed, all samples showed polymerization effectiveness when comparing the top and base of the block. Conclusion: Polymerization was effective in different thicknesses (2 mm, 4 mm, and 6 mm) in both resins studied. The microhardness ratio was adequate when comparing the base and top


Asunto(s)
Eficacia , Resinas Compuestas , Polimerizacion , Dureza
13.
Artículo en Inglés | LILACS-Express | LILACS | ID: biblio-1528851

RESUMEN

The present study analyzed the microhardness and degree of conversion of three Bulk Fill resins (M1 - Filtek Bulk Fill; M2 - Tetric N-Ceram Bulk Fill and M3 - Opus Bulk Fill) polymerized by single peak and polywave Light-emitting Diode Curing Lights. A total 90 test specimens (n=10) were obtained using a Teflon matrix for the purpose of testing microhardness; and for degree of conversion: 135 specimens (n=5) by using a 2 x 6 cm matrix. The specimens were light polymerized using 3 light sources (L1 - Optilight Max, L2 - Bluephase, L3 - VALO). They were kept in artificial saliva om an oven at 37±1°C during the experiment. The degree of conversion was measured by FTIR 24 h after obtaining each test specimen. The microhardness readouts were performed with a microdurometer at the time intervals of 48 hours (T0), 7 days (T1), 14 days (T2) and 21 days (T3). M1L3 was found to show the highest microhardness values in T2, and M1 showed the lowest degree of conversion in the deep third with L1. It was concluded that Filtek Bulk Fill resin showed the best results in comparison with the other resins.


El presente estudio analizó la microdureza y el grado de conversión de tres resinas Bulk Fill (M1 - Filtek Bulk Fill; M2 - Tetric N-Ceram Bulk Fill y M3 - Opus Bulk Fill) polimerizadas por lámparas de curado de diodo emisor de luz de pico único y polionda. Se obtuvieron un total de 90 especímenes de prueba (n=10) utilizando una matriz de teflón con el propósito de probar la microdureza; y para grado de conversión: 135 especímenes (n=5) utilizando una matriz de 2 x 6 cm. Las muestras se fotopolimerizaron utilizando 3 fuen- tes de luz (L1 - Optilight Max, L2 - Bluephase, L3 - VALO). Se mantuvieron en saliva artificial en estufa a 37 ±1°C durante el experimento. El grado de conversión se midió por FTIR 24 h después de obtener cada muestra de prueba. Las lecturas de microdureza se realizaron con un microdurómetro en los intervalos de tiempo de 48 horas (T0), 7 días (T1), 14 días (T2) y 21 días (T3). Se encontró que M1L3 mostraba los valores más altos de microdureza en T2, y M1 mostraba el grado más bajo de conversión en el tercio profundo con L1. Se concluyó que la resina Filtek Bulk Fill mostró los mejores resultados en comparación con las demás resinas.

14.
Rev. cuba. estomatol ; 60(4)dic. 2023.
Artículo en Español | LILACS, CUMED | ID: biblio-1550856

RESUMEN

Objetivo: Comparar el efecto de antibióticos pediátricos sobre la microdureza superficial del esmalte dental en dientes bovinos. Métodos: Se realizó un estudio in vitro en 60 dientes bovinos no cariados. Se sumergieron 15 dientes en cada grupo de cuatro soluciones (amoxicilina, amoxicilina + ácido clavulánico, eritromicina y saliva artificial) durante 1 minuto tres veces al día durante 7 y 14 días. Se midió la microdureza de la superficie del esmalte al inicio, a los7 y 14 días de exposición a los antibióticos. Resultados: La microdureza superficial del esmalte de los dientes de los grupos de antibióticos pediátricos se redujo después de 7 y 14 días de exposición con diferencia significativa (p < 0,001), respecto a la microdureza inicial. Además, en el grupo expuesto a saliva artificial no hubo diferencia significativa (p = 0,097) en los diferentes tiempos de evaluación. Conclusiones: Se concluye que los antibióticos pediátricos afectan la microdureza del esmalte, siendo la eritromicina la que mayor disminución generó a los 14 días de exposición(AU)


Objective: To compare the effect of pediatric antibiotics on the superficial microhardness of dental enamel in bovine teeth. Methods: An in vitro study was carried out on 60 non carious bovine teeth. Fifteen teeth were immersed in each group of four solutions (amoxicillin, amoxicillin + clavulanic acid, erythromycin and artificial saliva) for 1 minute three times a day for 7 and 14 days. Enamel surface microhardness was measured at baseline, 7 and 14 days of antibiotic exposure. Results: The enamel surface microhardness of the teeth of the pediatric antibiotic groups was reduced after seven and 14 days of exposure with significant difference (p < 0.001), with respect to the initial microhardness. In addition, in the group exposed to artificial saliva there was no significant difference (p = 0.097) at the different evaluation times. Conclusions: It is concluded that pediatric antibiotics affect enamel microhardness and erythromycin generated the greatest decrease at 14 days of exposure(AU)


Asunto(s)
Humanos , Niño , Amoxicilina/uso terapéutico , Antibacterianos/administración & dosificación
15.
Odontol.sanmarquina (Impr.) ; 26(3): e24730, jul.-set.2023.
Artículo en Inglés | LILACS-Express | LILACS | ID: biblio-1538051

RESUMEN

Objetive. Human teeth have been commonly used for in vitro and in situ studies. Cu­rrently, other animals' teeth have been purposed for dental research to overcome human teeth' problematic availability. This study aimed to investigate the enamel and dentin from human, bovine, and ovine teeth concerning the microhardness, organic, and in­ organic contents via micro­Raman spectroscopy. Methods. Human, bovine, and ovine teeth were divided according to their type and age into seven groups: Ovine; Bovine­12 months; Bovine­24 months; Bovine­36 months; Bovine­48 months; Bovine­+60 months; Human (control). The enamel's microhardness (superficial and deep) and den­tin (superficial, middle, and deep) were analyzed. The calcium/phosphate ratio and am­ide contents were determined by micro­Raman spectroscopy. Results. Overall, the mi­crohardness of human enamel was superior to the other species. Dentin's microhardness was similar among groups. Ovine group showed lower values of calcium/phosphate ratio than human. Amide content was similar between bovine and human. The microhardness and calcium/phosphate ratio of enamel and dentin, respectively, decreased as the age of bovine teeth increased. Conclusions. Researchers must be aware and take into consider­ation the differences of ovine and bovine enamel compared to human enamel. Other al­ternatives that are more similar to the microhardness of human enamel should be sought. Bovine teeth of 12 and 24 months are suitable substitutes for dentin of human teeth. Researchers must also be aware of the age of the animals and specify it in the studies.


Objetivo. Los dientes humanos se han utilizado comúnmente para estudios in vitro e in situ. Actualmente, los dientes de otros animales se han destinado a la investiga­ción dental para superar la disponibilidad problemática de los dientes humanos. Este estudio tuvo como objetivo investigar el esmalte y la dentina de los dientes humanos, bovinos y ovinos en relación con la microdureza y los contenidos orgánicos e inor­gánicos a través de la espectroscopia micro­Raman. Métodos. Los dientes humanos, bovinos y ovinos se dividieron según su tipo y edad en siete grupos: Ovinos; Bovino­12 meses; Bovino­24 meses; Bovino­36 meses; Bovino­48 meses; Bovino­+60 meses; Hu­mano (control). Se analizó la microdureza del esmalte (superficial y profunda) y de la dentina (superficial, media y profunda). La relación calcio/fosfato y los contenidos de amida se determinaron mediante espectroscopía micro­Raman. Resultados. En general, la microdureza del esmalte humano fue superior a la de otras especies. La microdureza de la dentina fue similar entre los grupos. El grupo ovino mostró valores más bajos de la relación calcio/fosfato que el humano. El contenido de amida fue similar entre bovinos y humanos. La microdureza y la relación calcio/fosfato del esmalte y la dentina, respectiva­mente, disminuyeron a medida que aumentaba la edad de los dientes bovinos. Conclusiones. El esmalte de los dientes ovinos y bovinos no es un sustituto adecuado del de los dientes humanos. Se deben buscar otras alternativas que sean similares a la microdureza del esmalte humano. Sin embargo, los dientes bovinos de 12 y 24 meses son sustitutos adecuados de la dentina de los dientes humanos. Los investigadores deben conocer la edad de los animales y especificarla en los estudios.

16.
Odontol.sanmarquina (Impr.) ; 26(3): e25460, jul.-set.2023.
Artículo en Español | LILACS-Express | LILACS | ID: biblio-1538052

RESUMEN

Objetivo. Comparar la dureza, estabilidad dimensional y resistencia a la compresión de los yesos dentales de alta resistencia y baja expansión disponibles en el Perú. Métodos. Se realizó un estudio descriptivo, observacional y transversal. Se confeccionaron muestras de forma cilíndrica (8) y rectangular (8), de siete yesos dentales de alta resistencia y baja expansión. Se evaluó la dureza utilizando el Durómetro Universal Identec, la estabilidad dimensional con un calibrador digital y la resistencia a compresión con la Máquina de Ensayo Universal. Para determinar si hay diferencia en cada una de estas propiedades se empleó el análisis de varianza, la prueba F y la prueba de Duncan. Además, se empleó la prueba de comparación de medias, t de Student, para evaluar si difieren con los valores de la ADA (Asociación Dental Americana). Resultados. La dureza, estabilidad dimen-sional y resistencia a la compresión promedio de los yesos dentales presentó diferencias significativas (p<0.05) entre cada uno con los promedios estándares establecidos por la ADA. Conclusiones. En relación resistencia a la compresión el 100% de los yesos analizados cumplen con los parámetros establecidos por la ADA, en relación estabilidad dimensional solo el 28.6% y el 100% no alcanzan los estándares de dureza promedio establecidos por la ADA.


Objective. To compare the hardness, dimensional stability, and compressive strength of high-strength, low-expansion dental plasters available in Peru, according to ADA criteria. Methods. A descriptive, observational and cross-sectional study was developed. A selection of 8 cylindrical-shaped samples and 8 rectangular- shaped ones, from seven high-resistance, low-expansion dental plasters were fabricated. The hardness was evaluated using the Identec Universal Durometer. Dimensional stability was evaluated with a digital caliper and compressive strength was evaluated with the Instron Universal Testing Machine. To determine if there is a difference in each of these properties, the analysis of variance, F test, and the Duncan's test were used. In addition, to assess whether these values differ from those of the ADA, the mean comparison test, student's t table, were used. Results. The hardness, dimensional stability and average compressive strength of the high-strength, low-expansion dental plasters showed that there are significant di-fferences (p<0.05) between each of the dental plasters and with the standard averages established by the American Dental Association. (ADA). Conclusions. 100% of the high-strength, low-expansion dental casts meet the parameters established by the ADA in terms of their compressive strength, only 28.6% of these comply with the ADA in terms of dimensional stability and that 100% of these do not meet the average hardness standards established by the ADA.

17.
Acta odontol. latinoam ; 36(1): 15-23, Apr. 2023. tab, graf
Artículo en Inglés | LILACS-Express | LILACS | ID: biblio-1447071

RESUMEN

ABSTRACT After ozone therapy for bleaching, it is important to evalúate enamel surface properties, to ensure that bleaching provides adequate conditions for sound dental substrate. Aim: The aim of this in vitro study was to evaluate the effects of a bleaching treatment with 10% carbamide peroxide (CP), with or without ozone (O), on the microhardness, roughness and micromorphology of the enamel surface. Materials and Method: Bovine enamel blocks were planed and distributed among the following three bleaching treatment groups (n=10): CP - 1 hour per day/14 days (Opalescence PF 10%/ Ultradent); O - 1 hour per day every 3 days/3 sessions (Medplus VPhilozon, 60 mcg/mL and oxygen flow rate of 1 L/min); and OCP - CP with O, 1 hour per day every 3 days/3 sessions. Enamel surface microhardness (Knoop), roughness (Ra), and micromorphology by scanning electron microscopy (5,000x magnificaron) were determined before and after the treatments. Results: ANOVA and Tukey-Kramer's test showed that enamel microhardness remained unchanged by treatment with O and OCP (p=0.0087), but decreased by treatment with CP. Treatment with O promoted higher enamel microhardness than the other groups (p=0.0169). Generalized linear mixed models for repeated measures over time indicated treatment with CP increased enamel roughness more than OCP or O (p=0.0003). CP produced slight irregularities in enamel micromorphology after the whitening treatment. O, with or without CP, maintained the mechanical and physical properties of microhardness and enamel surface micromorphology, and either maintained or reduced surface roughness, compared to the conventional tray-delivered CP bleaching treatment. Conclusions: Treatment with 10% carbamide peroxide in trays promoted greater changes in enamel surface properties than treatments with ozone and with 10% ozonized carbamide peroxide in the office.


RESUMO É importante avaliar as propriedades da superficie do esmalte após a aplicagao da ozonioterapia para clareamento, para garantir que o efeito clareadorproporcione condigoes adequadaspara um substrato dentário higido. Objetivo: O objetivo deste estudo in vitro foi avaliar os efeitos de um tratamento clareador com peróxido de carbamida (PC) a 10%, associado ou nao ao ozonio (O), na microdureza, rugosidade e micromorfologia da superficie do esmalte. Materials e Método: Blocos de esmalte bovino foram aplainados e distribuidos entre tres grupos de tratamento clareador (n=10): PC - 1 hora por dia/14 dias (Opalescence PF 10%/ Ultradent); O - 1 hora por dia a cada 3 dias/3 sessoes (Medplus VPhilozon, 60 mcg/mL e fluxo de oxigenio de 1 L/min); e PCO - CP com O, 1 hora por dia a cada 3 dias/3 sessoes. A microdureza (Knoop), a rugosidade (Ra) e a micromorfologia da superficie do esmalte avaliada por microscopia eletronica de varredura (aumento de 5.000x) foram analisadas antes e após os tratamentos. Resultados: ANOVA e teste de Tukey-Kramer mostraram que O e PCO mantiveram os valores de microdureza do esmalte ao final do tratamento (p=0,0087), enquanto PC promoveu diminuigao da microdureza. O promoveu maiores valores de microdureza do esmalte do que os outros grupos ao final do tratamento (p=0,0169). Modelos lineares generalizados mistos para medidas repetidas no tempo indicaram um aumento na rugosidade da superficie para PC, levando a maior rugosidade do esmalte ao final do tratamento, em comparagao com PCO ou O (p=0,0003). PC apresentou pequenas irregularidades na micromorfologia do esmalte após o tratamento clareador. O, com ou sem PC, manteve as propriedades mecánicas e fisicas de microdureza e micromorfologia da superficie do esmalte, e manteve ou reduziu a rugosidade da superficie, em comparagao com o tratamento clareador a base de PC aplicado em moldeira convencional. Conclusoes: O tratamento com peróxido de carbamida a 10% para uso em moldeiras promoveu maiores alteragoes nas propriedades de superficie do esmalte do que aquelas observadas nos tratamentos com ozonio e com peróxido de carbamida ozonizado a 10% para uso em consultório.

18.
Acta odontol. latinoam ; 36(1): 40-46, Apr. 2023. tab, graf
Artículo en Inglés | LILACS-Express | LILACS | ID: biblio-1447074

RESUMEN

ABSTRACT During ceramic veneer luting, resin cement polymerization is performed with interposition of the dental ceramic. Aim: To evaluate how and how much the photoactivation time affects the Vickers hardness of resin-based cements with interposed ceramic. Materials and Method: A total 24 specimens H mm in diameter and 1 mm thick were made from Paracore White Coltene (PC), Densell Resin Duo Cement (DC), 3MRelyX Veneer (RX) and Coltene Fill Up! (FU), interposing VitablockMarkII (Vita Zahnfabrik) feldspathic ceramic 0.6 mm thick during photoactivation. The materials were polymerized using 100% and 25% of the times indicated by the manufacturers with a Coltolux LED ((Coltene) light with intensity 1200 mW/cm2. Each polymerization time group consisted of three specimens of each material, which were stored dry in darkness at 37 °C for 7 days. Three Vickers microhardness measurements were made on the top and bottom surfaces of each specimen using a Vickers Future Tech FM300 microhardness tester (300 g, 5 s). The values were averaged, and the bottom/top ratios calculated. Results were analyzed by ANOVA. (p<0.05) complemented with multiple comparisons using Tukey's test (p<0.05). Results: Different photoactivation times were found to have a significant effect on hardness values of the cements evaluated, with significant differences between some of the cements. No statistically significant difference was found for the effect of photoactivation time on bottom/top microhardness ratio in those materials. Conclusions: Under the experimental conditions employed, it can be concluded that photopolymerization for shorter times and the interposition of restorative material significantly affectpolymerization quality as evaluated by microhardness, but the bottom/top ratio was unaffected by differences in polymerization time.


RESUMEN Durante la fijación de una carilla cerámica, la polimerización del cemento a base de resinas se realiza con la interposición de la cerámica dental. Objetivo: evaluar en qué forma y magnitud afecta el tiempo de fotoactivación en la dureza Vickers de los cementos a base de resinas con la cerámica interpuesta. Materiales y Método: se confeccionaron 24 probetas de 11 mm de diámetro y 1 mm de espesor con: Paracore White Coltene (PC), Resin Duo Cement de Densell (DC), RelyX Veneer de 3M (RX) y Fill Up! De Coltene (FU) interponiendo 0,6 mm de espesor de cerámica feldespática Vitablock Mark II (Vita Zahnfabrik) durante la fotoactivación. Se polimerizó utilizando el 100% y el 25% del tiempo indicado por el fabricante con lámpara Coltolux LED ((Coltene) con 1200 mW/cm2 de intensidad. Cada grupo quedó conformado con tres probetas de cada material que se almacenaron a oscuras y en seco a 37 °C durante 7 días. Se registraron tres mediciones de microdureza Vickers de las superficies top y bottom de cada probeta con un microdurómetro Vickers Future Tech FM300 (300 g, 5 s) y se calculó su promedio, así como la relación entre los valores registrados en cada una de sus caras. Los resultados fueron analizados por medio de la prueba de ANOVA. (p<0.05). complementada con comparaciones múltiples por medio de la prueba de Tukey (p<0.05). Resultados: se encontró un efecto significativo de la modificación del tiempo de fotoactivación en los valores de dureza de los cementos evaluados con diferencias significativas entre algunos de ellos. Simultáneamente no se encontró significación estadística en el efecto de ese factor sobre la relación microdureza bottom/top registrada en esos materiales. Conclusiones: en las condiciones experimentales empleadas puede concluirse que la fotopolimerización en menor tiempo e interposición de material restaurador afecta significativamente la calidad de polimerización evaluada mediante los valores de microdureza, pero la proporción bottom/ top no fue afectada en la variación en el tiempo de polimerización.

19.
Acta odontol. latinoam ; 36(1): 58-65, Apr. 2023. tab
Artículo en Inglés | LILACS-Express | LILACS | ID: biblio-1447077

RESUMEN

ABSTRACT Color stability is among the most frequent causes of restoration failures, and influences surface properties. Aim: The aim of this study was to investigate the influence of pigment solutions on low-shrinkage and conventional composites regarding changes in the physical properties of composite surfaces. Materials and Method: Specimens of four composites (Filtek Z350 XT, Point 4, N'Durance and Venus Diamond) were randomly distributed into three groups to be submitted to each of three pigment solutions (red wine, tomato sauce and coffee) in fifteen-minute daily cycles, for twenty-eight days. There were 12 groups altogether (n = 10). Color, surface roughness and hardness tests were performed. Statistical analysis includedAnalysis of variance (ANOVA) and Tukey's significance test (a = 0.05). Results: Color changes caused by the solutions did not differ significantly among Filtek Z350 XT, Venus Diamond and N'Durance. Hardness decreased significantly in Filtek Z350 XT and Venus Diamond after chemical challenge with each solution. For the composite independent factor, roughness was highest in Venus Diamond, followed by Filtek Z350 XT, Point 4 and N'Durance. Conclusions: Treatment with different pigment solutions (red wine, tomato sauce or coffee) increased stainability and decreased hardness of both low-shrinkage and conventional composites, while roughness was unaffected.


RESUMO A estabilidade de cor está entre as causas mais frequentes de falhas de restauragoes, que também influenciam suas propriedades superficiais. Objetivo: O objetivo do presente estudo foi investigar a influencia de solugoes de pigmentos em compósitos convencionais e de baixa retragao, bem como alteragoes naspropriedades físicas da superficie dos compósitos. Materiais eMétodo: Amostras de cada compósito (Filtek Z350XT, Point 4, N'Durance e Venus Diamond) foram distribuidas aleatoriamente em grupos submetidos a cada solugao pigmentante (vinho tinto, molho de tomate e café) em ciclos diários de quinze minutos, durante vinte e oito dias. Assim, totalizando 12 grupos (n = 10). Foram realizados testes de cor, rugosidade superficial e dureza. A Análise Estatistica foi realizada usando Análise de variáncia (ANOVA) e o teste de significáncia de Tukey (a = 0.05). Resultados: As alteragoes de cor desencadeadas pelas solugoes investigadas nao mostraram diferenga estatisticamente significativa entre os compósitos Filtek Z350 XT, Venus Diamond e N'Durance. Os valores de dureza registrados para Filtek Z350XT e Venus Diamond diminuiram significativamente após o desafio químico com cada uma das solugoes pigmentantes. Para o fator independente compósito, Venus Diamond registrou a maior rugosidade; foi seguido por Filtek Z350XT, Point 4 e N'Durance. Conclusoes: Os tratamentos das amostras com diferentes solugoes pigmentantes (vinho tinto, molho de tomate e café) aumentaram a manchabilidade dos compósitos convencionais e de baixa retragao e diminuiram sua dureza, embora nao tenham afetado a rugosidade dos compósitos.

20.
Indian J Biochem Biophys ; 2023 Feb; 60(2): 122-128
Artículo | IMSEAR | ID: sea-221620

RESUMEN

Buccal tablets


Diclofenac sodium


Drug release


Mucoadhesion


Mucoadhesive tablets


Release kinetics

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA