Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Añadir filtros








Intervalo de año
1.
Braz. j. pharm. sci ; 51(1): 203-211, Jan-Mar/2015. tab, graf
Artículo en Inglés | LILACS | ID: lil-751358

RESUMEN

Average bioequivalence of two 500 mg levofloxacin formulations available in Brazil, Tavanic(c) (Sanofi-Aventis Farmacêutica Ltda, Brazil, reference product) and Levaquin(c) (Janssen-Cilag Farmacêutica Ltda, Brazil, test product) was evaluated by means of a randomized, open-label, 2-way crossover study performed in 26 healthy Brazilian volunteers under fasting conditions. A single dose of 500 mg levofloxacin tablets was orally administered, and blood samples were collected over a period of 48 hours. Levofloxacin plasmatic concentrations were determined using a validated HPLC method. Pharmacokinetic parameters Cmax, Tmax, Kel, T1/2el, AUC0-t and AUC0-inf were calculated using noncompartmental analysis. Bioequivalence was determined by calculating 90% confidence intervals (90% CI) for the ratio of Cmax, AUC0-t and AUC0-inf values for test and reference products, using logarithmic transformed data. Tolerability was assessed by monitoring vital signs and laboratory analysis results, by subject interviews and by spontaneous report of adverse events. 90% CIs for Cmax, AUC0-t and AUC0-inf were 92.1% - 108.2%, 90.7% - 98.0%, and 94.8% - 100.0%, respectively. Observed adverse events were nausea and headache. It was concluded that Tavanic(c) and Levaquin(c) are bioequivalent, since 90% CIs are within the 80% - 125% interval proposed by regulatory agencies.


A bioequivalência média de duas formulações de levofloxacino disponíveis no Brasil, Tavanic(c) (Sanofi-Aventis Farmacêutica Ltda, Brasil, produto referência) e Levaquin(c) (Janssen-Cilag Farmacêutica Ltda, Brasil, produto teste) foi determinada por meio da realização de ensaio aleatório, aberto, cruzado, com dois períodos e duas sequências, em 26 voluntários sadios em condições de jejum. Amostras de sangue dos voluntários foram obtidas ao longo de um período de 48 horas após administração de dose única de 500 mg de levofloxacino. As concentrações plasmáticas do fármaco foram determinadas por método cromatográfico validado. Os parâmetros farmacocinéticos Cmax, Tmax, Kel, T1/2el, AUC0-t e AUC0-inf foram calculados por análise não compartimental. A bioequivalência foi determinada pelo cálculo de intervalos de confiança 90% (IC 90%) para as razões entre os valores de Cmax, AUC0-t e AUC0-inf obtidos para os produtos teste e referência, usando dados transformados logaritmicamente. A tolerabilidade foi avaliada pelo acompanhamento dos sinais vitais e resultados de exames laboratoriais, por consultas e por relato espontâneo dos voluntários. ICs 90% para Cmax, AUC0-t e AUC0-inf foram 92.1% - 108.2%, 90.7% - 98.0%, e 94.8% - 100.0%, respectivamente. Os eventos adversos observados foram náusea e cefaleia. Concluiu-se que os produtos Tavanic(c) e Levaquin(c) são bioequivalentes, uma vez que os ICs 90% estão dentro da faixa de 80%-125% proposta pelas agências reguladoras.


Asunto(s)
Humanos , Voluntarios/clasificación , Equivalencia Terapéutica , Distribución Aleatoria , Dosis Única/efectos de los fármacos , Levofloxacino/análisis , Farmacocinética , Cromatografía Liquida/métodos
2.
Braz. j. pharm. sci ; 50(2): 381-389, Apr-Jun/2014. tab, graf
Artículo en Inglés | LILACS | ID: lil-722182

RESUMEN

In recent decades, there has been a significant increase in the incidence of fungal diseases. Certain fungal diseases cause cutaneous lesions and in the usual treatment, generally administred orally, the drug reaches the site of action with difficulty and its concentration is too low. An approach much explored in recent years is the development of nanotechnology-based drug delivery systems, and microemulsions (ME) and liquid crystals (LC) are promising. ME and LC were developed with oleic acid or copaiba oil as the oil phase, propoxyl (5OP) ethoxyl (20 OE) cetyl alcohol as surfactant and water. An analytical method to assess the incorporation of fluconazole (FLU) in the systems under study was validated according to guidelines of the International Conference on Harmonization (ICH) guidelines and the Brazilian Food, Drug and Sanitation Agency (ANVISA). The method was conducted on a C18-RP column (250 × 4.6 mm i.d.), maintained at room temperature. The mobile phase consisted of acetonitrile and water (50:50, v/v), run at a flow rate of 1.0mL/min and using ultraviolet detection at 210nm. The chromatographic separation was obtained with a retention time of 6.3min, and was linear in the range of 20-400 µg/mL (r2=0.9999). The specificity showed no interference of the excipients. The accuracy was 100.76%. The limits of detection and quantitation were 0.057 and 0.172 µg.mL-1, respectively. Moreover, method validation demonstrated satisfactory results for precision and robustness. The proposed method was applied for the analysis of the incorporation of FLU in ME and LC, contributing to improve the quality control and to assure the therapeutic efficacy.


Nas últimas décadas, houve aumento significativo na incidência de doenças fúngicas. Certas doenças fúngicas provocam lesões cutâneas, sendo que no tratamento usual, geralmente administrado por via oral, o medicamento chega ao local de ação com dificuldade, em concentração muito baixa. Uma abordagem muito explorada nos últimos anos é o desenvolvimento de sistemas de administração de fármacos baseados em nanotecnologia, como as microemulsões (ME) e cristais líquidos (LC). ME e LC foram desenvolvidos com o ácido oleico ou óleo de copaíba como fase oleosa, álcool cetílico propoxilado (5 OP) e etoxilado (20 OE) como tensoativo e água. Método analítico para avaliar a incorporação de fluconazol (FLU) nos sistemas em estudo foi validado de acordo com as diretrizes da Conferência Internacional de Harmonização (ICH) e Agência Nacional de Vigilância Sanitária (ANVISA). O método foi desenvolvido empregando coluna C18-RP (250 x 4,6 mm id), mantida à temperatura ambiente. A fase móvel consistiu de acetonitrila e água (50:50, v/v), executado a uma taxa de fluxo de 1,0 mL/min e com detecção ultravioleta a 210 nm. A separação cromatográfica foi obtida com o tempo de retenção de 6,3min, e mostrou-se linear no intervalo de 20-400 µg/mL (r2=0,9999). Pelo estudo de especificidade, observou-se não interferência dos excipientes. A precisão foi 100,76%. Os limites de detecção e de quantificação foram 0,057 e 0,172 µg.mL-1, respectivamente. Além disso, a validação do método demonstrou resultados satisfatórios para a precisão e robustez. O método proposto foi aplicado para a análise da incorporação do FLU em ME e cristais líquidos, contribuindo para aumentar o controle de qualidade e garantir a eficácia terapêutica.


Asunto(s)
Fluconazol/análisis , Cromatografía Liquida/clasificación , Cristales Líquidos/clasificación , Estudios de Validación como Asunto , Nanotecnología/clasificación
3.
Braz. j. pharm. sci ; 50(2): 423-429, Apr-Jun/2014. tab, graf
Artículo en Inglés | LILACS | ID: lil-722195

RESUMEN

The present study describes the development and validation of an in vitro dissolution method for evaluation to release diclofenac potassium in oral suspension. The dissolution test was developed and validated according to international guidelines. Parameters like linearity, specificity, precision and accuracy were evaluated, as well as the influence of rotation speed and surfactant concentration on the medium. After selecting the best conditions, the method was validated using apparatus 2 (paddle), 50-rpm rotation speed, 900 mL of water with 0.3% sodium lauryl sulfate (SLS) as dissolution medium at 37.0 ± 0.5°C. Samples were analyzed using the HPLC-UV (PDA) method. The results obtained were satisfactory for the parameters evaluated. The method developed may be useful in routine quality control for pharmaceutical industries that produce oral suspensions containing diclofenac potassium.


O presente estudo descreve o desenvolvimento e validação de um método de dissolução in vitro para avaliação da liberação de diclofenaco potássico suspensão oral. O teste de dissolução foi desenvolvido e validado de acordo com as diretrizes internacionais. Parâmetros como linearidade, especificidade, precisão e exatidão foram avaliados, bem como a influência da velocidade de rotação e a concentração de tensoativono meio. Depois de selecionar as melhores condições, o método foi validado usando o aparato 2 (pás), velocidade de rotação de 50 rpm, 900 mL de água com 0,3% de lauril sulfato de sódio (LSS) como meio de dissolução a 37,0 ± 0,5 ºC. As amostras foram analisadas pelo método de CLAE-UV (PDA). Os resultados obtidos foram satisfatórios para os parâmetros avaliados. O método desenvolvido pode ser útil na rotina de controle de qualidade para as indústrias farmacêuticas que produzem suspensões orais contendo diclofenaco potássico.


Asunto(s)
Diclofenaco/clasificación , Cromatografía Líquida de Alta Presión/métodos , Estudio de Validación , Control de Calidad , Disolución/métodos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA