The Journal of Korean Academy of Prosthodontics ; : 292-298, 2012.
Artículo en Coreano | WPRIM | ID: wpr-33057

RESUMEN

PURPOSE: The purpose of this study is to ascertain the stability of the implant by comparing the effects of the change of implant diameter, length and design on implant stability quotient. MATERIALS AND METHODS: To remove the variable due to the difference of bone quality, the uniform density (0.48 g/cm3) Polyuretane foam blocks (Sawbones(R), Pacific Research Laboratories Inc, Vashon, Washington) were used. Implants (Implantium(R), Dentium, Seoul, Korea) were placed with varying diameters (phi3.8, phi4.3 and phi4.8) and length (8 mm, 10 mm and 12 mm), to assess the effect on implant stability index (ISQ). Also the influence of the design of the submerged and the non-submerged (SimplelineII(R), Dentium, Seoul, Korea) on ISQ was evaluated. To exclude the influence of insertion torque, a total of 60 implants (n = 10) were placed with same torque to 35 N. Using Osstell(TM) mentor (Integration Diagnostic AB, Sweden) ISQ values were recorded after measuring the resonant frequency, one-way ANOVA and Tukey HSD test results were analyzed. (alpha=0.05). RESULTS: 1. The change of the diameter of the implant did not affect the ISQ (P>.05), but the increase of implant length increased the ISQ(P<.001). 2. The change in implant design were correlated with the ISQ, and the ISQ of submerged design was significantly higher than that of the non-submerged design(P<.05). CONCLUSION: In order to increase implant stability, the longer implant is better to be selected, and on the same length of implant, submerged design is thought to be able to get a higher ISQ than the non-submerged.


Asunto(s)
Humanos , Mentores , Torque
2.
The Journal of Advanced Prosthodontics ; : 10-15, 2011.
Artículo en Inglés | WPRIM | ID: wpr-67270

RESUMEN

PURPOSE: This study investigated the influence of bone quality and surgical technique on the implant stability quotient (ISQ) value. In addition, the influence of interfacial bone quality, directly surrounding the implant fixture, on the resonance frequency of the structure was also evaluated by the finite element analysis. MATERIALS AND METHODS: Two different types of bone (type 1 and type 2) were extracted and trimmed from pig rib bone. In each type of bone, the same implants were installed in three different ways: (1) Compaction, (2) Self-tapping, and (3) Tapping. The ISQ value was measured and analyzed to evaluate the influence of bone quality and surgical technique on the implant primary stability. For finite element analysis, a three dimensional implant fixture-bone structure was designed and the fundamental resonance frequency of the structure was measured with three different density of interfacial bone surrounding the implant fixture. RESULTS: In each group, the ISQ values were higher in type 1 bone than those in type 2 bone. Among three different insertion methods, the Tapping group showed the lowest ISQ value in both type 1 and type 2 bones. In both bone types, the Compaction groups showed slightly higher mean ISQ values than the Self-tapping groups, but the differences were not statistically significant. Increased interfacial bone density raised the resonance frequency value in the finite element analysis. CONCLUSION: Both bone quality and surgical technique have influence on the implant primary stability, and resonance frequency has a positive relation with the density of implant fixture-surrounding bone.


Asunto(s)
Densidad Ósea , Análisis de Elementos Finitos , Costillas
3.
Journal of the Korean Association of Oral and Maxillofacial Surgeons ; : 417-422, 2010.
Artículo en Coreano | WPRIM | ID: wpr-186456

RESUMEN

INTRODUCTION: Bone density is one of the important factors for the long term success of endosseous implants. The bone density varies from site to site and from patient to patient. A preoperative evaluation of the bone density is quite useful to oral surgeons for planning dental implantation. More accurate information on the bone density will help surgeons identify suitable implant sites, thereby increase the success rate of dental implantation. This study examined the correlation between the bone density measured preoperatively by computed tomography (CT) and the implant primary stability measured by resonance frequency analysis. Furthermore, the effects of the implant sites, gender, age and generalized systemic disorder patients on the bone density and primary implant stability were examined. MATERIALS AND METHODS: One hundred and fourteen patients were selected. None of the patients had undergone a tooth extraction or bone graft history in the previous year. Preoperatively, the patients underwent CT scanning to evaluate the Hounsfield unit (HU), and resonance frequency analysis (RFA) was used to evaluate the implant primary stability at the time of implant installation. All implants were 4.0 mm diameter and 11.5 mm length US II. All patients were recorded and the HU and implant stability quotient (ISQ) value were evaluated according to the sites, gender and age. RESULTS: The highest HU values were found in the mandibular anterior site (827.6+/-151.4), followed by the mandibular molar site (797+/-135.1), mandibular premolar site (753.8+/-171.2), maxillary anterior site (726.3+/-154.4), maxillary premolar site (656.7+/-173.8) and maxillary molar site (621.5+/-164.9). The ISQ value was the highest in the mandibular premolar site (81.5+/-2.4) followed by the mandibular molar site (80.0+/-5.7), maxillary anterior site (77.4+/-4.1), mandibular anterior site (76.4+/-11.9), maxillary premolar site (74.2+/-14.3) and maxillary molar site (73.7+/-7.4). The mean HU and ISQ value were similar in females and males. (HU: P=0.331, ISQ: P=0.595) No significant difference was also found in the age group respectively. However, the correlation coefficients between the variables showed a closed correlation between the HU and ISQ value. CONCLUSION: These results showed close correlation between the bone density (HU) and primary stability value (ISQ) at the time of implant installation (Correlation coefficients=0.497, P<0.01). These results strengthen the hypothesis that it might be possible to predict and quantify the initial implant stability and bone density from a presurgical CT diagnosis. These results strengthen the hypothesis that it might be possible to predict and quantify the initial implant stability and bone density from a presurgical CT diagnosis.


Asunto(s)
Femenino , Humanos , Masculino , Diente Premolar , Densidad Ósea , Implantación Dental , Implantes Dentales , Diente Molar , Oseointegración , Extracción Dental , Trasplantes
4.
The Journal of Advanced Prosthodontics ; : 47-55, 2009.
Artículo en Inglés | WPRIM | ID: wpr-111182

RESUMEN

STATEMENT OF PROBLEM: A few of studies which compared and continuously measured the stability of various surface treated implants in the same individual had been performed. PURPOSE: We aim to find the clinical significance of surface treatments by observing the differences in the stabilization stages of implant stability. MATERIAL AND METHODS: Eight different surface topographies of dental implants were especially designed for the present study. Machined surface implants were used as a control group. 4 nano-treated surface implants (20 nm TiO2 coating surface, heat-treated 80 nm TiO2 coating surface, CaP coating surface, heat treated CaP coating surface) and 3 micro-treated surface implants [resorbable blast media (RBM) surface, sandblast and acid-etched (SAE) surface, anodized RBM surface] were used as experiment groups. All 24 implants were placed in 3 adult dogs. Periotest(R) & ISQ values measured for 8 weeks and all animals were sacrificed at 8 weeks after surgery. Then the histological analyses were done. RESULTS: In PTV, all implants were stabilized except 1 failed implants. In ISQ values, The lowest stability was observed at different times for each individual. The ISQ values were showed increased tendency after 5 weeks in every groups. After 4 to 5 weeks, the values were stabilized. There was no statistical correlation between the ISQ values and PTV. In the histological findings, the bone formation was observed to be adequate in general and no differences among the 8 surface treated implants. CONCLUSIONS: In this study, the difference in the stability of the implants was determined not by the differences in the surface treatment but by the individual specificity.


Asunto(s)
Adulto , Animales , Perros , Humanos , Implantes Dentales , Calor , Osteogénesis , Sensibilidad y Especificidad , Titanio
5.
The Journal of Korean Academy of Prosthodontics ; : 98-106, 2007.
Artículo en Coreano | WPRIM | ID: wpr-218246

RESUMEN

STATEMENT OF PROBLEM: Current tendencies of the implant macrodesign are tapered shapes for improved primary stability, but there are lack of studies regarding the relationship between the implant macrodesign and primary stability. PURPOSE: The purpose is to investigate the effect of implant macrodesign on the implant primary stability by way of resonance frequency analysis in the bovine rib bones with different kinds of quality. MATERIAL AND METHOD: Fifty implants of 6 different kinds from two Korean implant systems were used for the test. Bovine rib bones were cut into one hundred pieces with the length of 5 cm. Among them forty pieces of rib bones with similar qualities were again selected. For the experimental group 1, the thickness of cortical part was measured and 20 pieces of rib bones with the mean thickness of 1.0mm were selected for implant placement. For the experimental group 2, the cortical parts of the remaining 20 pieces of rib bones were totally removed and then implants were placed on the pure cancellous bone according to the surgical manual. After placement of all implants, the implant stability quotient(ISQ) was measured by three times, and its statistical analysis was done. RESULTS: There are statistically significant differences in ISQ values among 4 different kinds of Avana system implants in the experimental group 2. For the experimental group 1, Avana system implants showed significantly different ISQ values, but when differences in the thickness of cortical parts were statistically considered, did not show any significant differences in ISQ values. Among Oneplant system implants, there are no significant differences in ISQ values for the experimental group 2 as well as for the experimental group 1. CONCLUSION: Within the limits of this study, bone quality and implant design have some influences on the primary stability of implants. Especially in the bone of poor quality, tapered shape of implants are more favorable for the primary stability of implants.


Asunto(s)
Costillas
6.
Journal of Practical Stomatology ; (6)2000.
Artículo en Chino | WPRIM | ID: wpr-670876

RESUMEN

0.05). Conclude:The bone type may affect the stability of ITI osseointegrated implants.