Journal of Dental Rehabilitation and Applied Science ; : 310-315, 2015.
Artículo en Coreano | WPRIM | ID: wpr-45375

RESUMEN

PURPOSE: The purpose of this study was to measure the tightening torque for dental implant in dental laboratory and to analyze of the effects of different tightening torque. MATERIALS AND METHODS: The tightening torque for dental implant in dental laboratory were measured by digital torque gauge. The length of abutment and analog were measured as tightening torque of manufacturer's instructions and the measured value. And the data were statically analyzed. RESULTS: The mean tightening torque of implant screw in dental laboratory was 1.563 +/- 0.332 Ncm. The external type implant system of total length were showing no significant differences but the internal type implant system had difference significant (P < 0.05) when compared with tightening torque. CONCLUSION: The implant prosthesis should be made under manufacturer's instructions especially as tightening torque of screw. For the fidelity of implant prosthesis, dental technician should learn how to use the torque gauge.


Asunto(s)
Humanos , Implantes Dentales , Prótesis Dental , Técnicos Dentales , Laboratorios Odontológicos , Prótesis e Implantes , Torque
2.
The Journal of Korean Academy of Prosthodontics ; : 197-205, 2011.
Artículo en Coreano | WPRIM | ID: wpr-112326

RESUMEN

PURPOSE: This study was to evaluate the accuracy of the implant torque controller used in dental clinics and to investigate whether it was applied appropriately. MATERIALS AND METHODS: Fifty dentists who work in dental clinics were enrolled in this study. Dental (implant) practice career, experience frequency of implant screw loosening and fracture, education of implant torque controller application and infection control methods were included in the survey. 25 Ncm and 30 Ncm of the tightening torque applied to the implant screw were measured by 50 clinicians. After measuring the torque value by using the torque controller, the torque mean according to where education about the implant torque controller was received was analyzed with independent t-test at the significance level of 0.05. RESULTS: The torque controller used in private dental clinics showed 4.78% error ratio. When 50 dentists applied 25 Ncm to the implant screw was 29.0 +/- 8.4 Ncm, and that in 30 Ncm was 34.3 +/- 9.1 Ncm. Statistical significance was found between the group that was educated about implant torque application and the group that was not educated. CONCLUSION: During the prosthodontic treatment with implant, there was difference between actual applied torsion force and the amount torque controller indicated. Clinicians have to not only be well-informed about the accurate usage method of the torque controller, but also keep and manage the torque controller so as to maintain continuous and accurate torque values. Through this, it is considered to achieve clinical results to minimize problems of screw loosening or fracture.


Asunto(s)
Humanos , Clínicas Odontológicas , Odontólogos , Control de Infecciones , Prostodoncia , Torque