Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Añadir filtros








Intervalo de año
1.
Rev. Paul. Pediatr. (Ed. Port., Online) ; 36(3): 364-371, jul.-set. 2018. tab, graf
Artículo en Portugués | LILACS | ID: biblio-977063

RESUMEN

RESUMO Objetivo: Comparar a eficácia no tratamento da asma pediátrica por nebulizador e inalador dosimetrado com uso de espaçador (MDI-espaçador), no emprego das técnicas de resgate de pacientes asmáticos atendidos em emergências pediátricas. Fontes de dados: Realizou-se uma revisão sistemática para identificar os principais estudos randomizados controlados que comparam a administração de broncodilatador (β-2 agonista) por meio das técnicas inalatórias nebulização e MDI-espaçador no tratamento da asma em unidades de emergência pediátrica. Foram pesquisadas as bases de dados PubMed, Scientific Electronic Library Online (SciELO) e ScienceDirect. Dois pesquisadores, de forma independente, aplicaram os critérios de elegibilidade, sendo incluídos na pesquisa apenas estudos randomizados controlados com o objetivo de comparar as técnicas inalatórias nebulização e MDI-espaçador no tratamento da asma em unidades de emergência pediátrica. Síntese dos dados: Foram pré-selecionados 212 artigos, dos quais apenas nove seguiram os critérios de elegibilidade e foram incluídos na metanálise. Os resultados apontam não existir diferenças nas técnicas inalatórias em nenhum dos quatro desfechos analisados: frequência cardíaca (diferença -Df: 1,99 [intervalo de confiança de 95% - IC95% -2,01-6,00]); frequência respiratória (Df: 0,11 [IC95% -1,35-1,56]); saturação de O2 (Df: -0,01 [IC95% -0,50-0,48]); e escore clínico de asma (Df: 0,06 [IC95% -0,26-0,38]). Conclusões: Os achados demonstram não haver diferenças na frequência cardiorrespiratória, na saturação de O2 nem nos escores de asma, na administração de β-2 agonista entre as técnicas inalatórias (nebulizador e MDI-espaçador) em pacientes asmáticos atendidos em emergências pediátricas.


ABSTRACT Objective: To compare the efficacy of pediatric asthma treatment by nebulizer and metered-dose inhaler with the use of a spacer (MDI-spacer) in rescue techniques for asthmatic patients assisted at pediatric emergency units. Data sources: A systematic review was conducted to identify the most relevant randomized controlled trials comparing the administration of a bronchodilator (β-2 agonist) by two inhalation techniques (nebulization and MDI-spacer) to treat asthma in children at pediatric emergency units. The following databases were searched: PubMed, Scientific Electronic Library Online (SciELO), and ScienceDirect. Two researchers independently applied the eligibility criteria, and only randomized controlled trials that compared both inhalation techniques (nebulization and MDI-spacer) for asthma treatment at pediatric emergency units were included. Data synthesis: 212 articles were pre-selected, of which only nine met the eligibility criteria and were included in meta-analysis. Results show no differences between inhalation techniques for any of the four outcomes analyzed: heart rate (difference - Df: 1.99 [95% confidence interval - 95%CI -2.01-6.00]); respiratory rate (Df: 0.11 [95%CI -1.35-1.56]); O2 saturation (Df: -0.01 [95%CI -0.50-0.48]); and asthma score (Df: 0.06 [95%CI -0,26-0.38]). Conclusions: The findings demonstrate no differences in cardiorespiratory frequency, O2 saturation, and asthma scores upon administration of β-2 agonist by both inhalation techniques (nebulization and MDI-spacer) to asthmatic patients assisted at pediatric emergency units.


Asunto(s)
Humanos , Niño , Adolescente , Asma/tratamiento farmacológico , Broncodilatadores/administración & dosificación , Administración por Inhalación , Nebulizadores y Vaporizadores , Ensayos Clínicos Controlados Aleatorios como Asunto , Enfermedad Aguda , Inhaladores de Dosis Medida
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA