1.
China Pharmacist
;
(12): 154-155,156, 2017.
Artículo
en Chino
| WPRIM
| ID: wpr-606107
RESUMEN
Objective:To establish a method for the content determination of magnesium in esomeprazole magnesium. Methods:The content of magnesium in esomeprazole magnesium was determined by inductive coupled plasma atomic emission spectrometry. Re-sults:The linear range was 10.0-80.0 μg·ml-1(r=0.999 8). The average recovery was 99.55% with RSD of 1.35% (n=9). The detection limit was 0. 000 75 μg·ml-1 and the quantitative limit was 0. 002 5 μg·ml-1 . Conclusion:The method is accurate, sensitive and reproducible, which can be used for the content determination of magnesium in esomeprazole magnesium.