Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 638
Filtrar
1.
Journal of Prevention and Treatment for Stomatological Diseases ; (12): 101-107, 2024.
Artículo en Chino | WPRIM | ID: wpr-1006354

RESUMEN

Objective@#The purpose of this study was to investigate the differences in the anti cyclic fatigue performance of Woride KS (WKS), Proteper Gold (PTG), and Hyflex CM (HCM) nickel titanium instruments with different tip diameters in curved root canal models, and to provide reference for the targeted selection of suitable nickel titanium instruments in clinical preparation of curved root canals.

2.
Braz. oral res. (Online) ; 38: e006, 2024. tab, graf
Artículo en Inglés | LILACS-Express | LILACS, BBO | ID: biblio-1528151

RESUMEN

Abstract The aim of this study was to evaluate the root canal shaping effect of ProTaper Gold (PTG) versus ProTaper Next (PTN) instrumentation systems, and of a manual #15 K-type file (K15) versus the ProGlider (PG) mechanized instrument for glide path creation, in severely curved mesial canals. Twenty-four mandibular molars with two separate mesial canals were anatomically matched using computed tomographic scanning, and then divided into two groups (n=12) according to the glide path instrument used, either K15 or PG. In all teeth, the PTG system was used to prepare the mesiobuccal canal, and the PTN, the mesiolingual canal. The teeth were scanned by computed microtomography, before and after root canal preparation, and the values of the initial volume, final volume, volumetric variation, untouched walls, and canal transportation variables were determined. The data were analyzed using the two-way ANOVA test, and the Tukey test for multiple comparisons. There was no significant difference among the study groups regarding volumetric variation or root canal transportation, either in the cervical, middle or apical thirds, or in the entire root canal (p>0.05). In the apical third, the percentage of untouched walls was significantly higher in groups using K15 than in those using PG (p<0.05), namely 33.144% and 23.285%, respectively, irrespective of the instrumentation system. In the other regions, there was no difference between K15 and PG regarding this variable. It was concluded that PG was associated with a lower rate of untouched walls in the apical region than K15.

3.
Trends psychiatry psychother. (Impr.) ; 46: e20220492, 2024. tab
Artículo en Inglés | LILACS-Express | LILACS | ID: biblio-1536920

RESUMEN

Abstract Objective Grazing is a disturbed eating pattern that has been associated with eating disorders and obesity. One of the new measures to investigate this eating behavior is the Short Inventory of Grazing (SIG), a two-item questionnaire that assesses grazing in general and grazing associated with the feeling of loss of control over eating (LOC grazing). However, the psychometric properties of the SIG have not been assessed in the Brazilian population. The present study aimed to cross-culturally adapt and validate a Brazilian version of the SIG. Methods The SIG was adapted to the Brazilian context following international guidelines. Then, 90 undergraduate students completed an online survey including questions from the SIG, the Binge Eating Scale (BES), the Patient Health Questionnaire-9 (PHQ9), the Generalized Anxiety Disorder-7 (GAD7), and a question related to self-reported health status. The internal consistency, test-retest reliability, and convergent validity of the questionnaire were assessed. Results The prevalence rates of at least one weekly episode of grazing in general and LOC grazing were 71.1 and 54.5%, respectively. The internal consistence of the SIG was acceptable (0.81). In addition, SIG scores on both items were positively and significantly associated with BES, GAD7, and PHQ9 scores, and with poorer self-rated health. However, SIG test and retest scores differed significantly. Conclusion Overall, the Brazilian version of the SIG demonstrated adequate psychometric properties. The instrument had adequate internal consistency, with both items exhibiting good convergent validity with related measures.

4.
São Paulo med. j ; 142(2): e2023325, 2024. tab, graf
Artículo en Inglés | LILACS-Express | LILACS | ID: biblio-1551073

RESUMEN

ABSTRACT BACKGROUND: The Positive Aspects of Caregiving (PAC) scale is used to assess psychosocial benefits provided to caregivers by the task of caring. The PAC scale consists of nine items, assessed using a five-point Likert scale, with higher values indicating greater positive perceptions and gains from the caregiving experience. OBJECTIVE: To translate and culturally adapt the PAC scale for informal Brazilian caregivers of people with dementia. DESIGN AND SETTING: A methodological study was conducted at the Federal University of São Carlos. METHODS: The following stages were carried out: Translation; Synthesis of the translations; Back-translation; Evaluation by an experts' committee; and Pre-test. RESULTS: Two independent professionals translated the PAC scale. The consensus version was obtained by merging both translations, which were back-translated into English by a third translator. The expert committee comprised three specialists in the area and project researchers. All scale items presented a Content Validity Index of 1 (CVI = 1.0), and thus remained in the pre-final version of the instrument. The instrument was pre-tested with seven caregivers of people with dementia, the majority of whom were women (57.1%), with a degree of kinship corresponding to sons/daughters (57.1%) and an average age of 55.2 (± 4.1) years. The caregivers considered it clear and understandable and made no suggestions for changes. CONCLUSION: The PAC scale was translated and culturally adapted for use by informal caregivers of people with dementia in Brazil. However, a psychometric analysis of the instrument is necessary to provide normative data for this population group.

5.
Interaçao psicol ; 27(3): 330-340, ago.-dez. 2023.
Artículo en Portugués | LILACS-Express | LILACS | ID: biblio-1531341

RESUMEN

A autoestima é um termo muito utilizado pelas pessoas no senso comum, mas ainda são necessários mais estudos para entendê-lo sob o ponto de vista comportamental. O objetivo deste estudo foi realizar uma revisão de textos da Análise do Comportamento a respeito de autoestima. Foi realizada uma busca em três fontes diferentes: periódicos exclusivos de Análise do Comportamento; as coleções de livros Sobre Comportamento e Cognição e Comportamento em Foco; e na Scielo. No total, 16 textos preencheram os critérios, que eram a) ter a palavra "autoestima" no título b) ser um texto da Análise do Comportamento. Foram discutidas as definições de autoestima utilizadas, os participantes dos estudos, os estímulos usados em testes de medida implícita e os principais resultados. Nenhum dos textos analisados utilizou intervenções voltadas ao aumento da autoestima. Apesar de serem textos da abordagem comportamental, muitos dos estudos utilizam apenas definições e instrumentos não comportamentais. As principais conclusões da revisão foram: 1) ainda existem poucos estudos sobre autoestima na Análise do Comportamento; 2) ainda não existe uma definição comportamental bem construída, especialmente na literatura internacional.


Self-esteem is a term that is widely used in common sense, but more studies are still needed to understand it from a behavioral point of view. The objective of this study was to carry out a review of Behavior Analysis papers regarding self-esteem. A search was conducted in three different sources: Behavior Analysis journals; the book collections Sobre Comportamento e Cognição and Comportamento em Foco; and on Scielo. In total, 16 texts met the criteria, which were a) having the word "self-esteem" in the title and b) being a Behavior Analysis text. We discuss the definitions of self-esteem used, the participants in the studies, the stimuli used in the implicit measurement tests and the main results. None of the analyzed texts used interventions aimed to increase self-esteem. Even though they are texts of the behavioral approach, many of the studies only use non-behavioral definitions and instruments. The main conclusions of the review were: 1) there are still few studies on self-esteem in Behavior Analysis; 2) there is still no well-constructed behavioral definition, especially in international literature.

6.
J. res. dent ; 11(2): 25-31, Oct 2023.
Artículo en Inglés | LILACS-Express | LILACS | ID: biblio-1513036

RESUMEN

Aims: The aim was to evaluate the cyclic and torsional fatigue resistance among thermally treated NiTi rotary instruments with different design features.Materials and methods: Sixty instruments of three systems were used (n=20): TruNatomy 26.04 (TN 26.04), BassiLogic 25.05 (BL 25.05), and Flat File 25.04 (FF 25.04). The cyclic fatigue test (n=10) was performed to evaluate the time to fracture (s) and the number of cycles until failure (NCF). The torsion test was performed to evaluate the torque (N.cm) and maximum angular deflection until fracture (n=10). The fracture surface of each fragment was examined under a scanning electron microscope. The data were analyzed by Tukey's test (p<0.05).Results: BL 25.05 and FF 25.04 instruments had a higher number of cycles and time to fracture compared with TN 26.04 (p<0.05). TN 26.04 instruments showed lower torque to fracture.Conclusions: Based on the proposed objectives and the methodology used, TruNatomy 26.04 instruments present lower resistance to cyclic fatigue and torsional fatigue when compared to BassiLogic 25.05 and Flat File 25.04 instruments.

8.
RFO UPF ; 28(1)20230808. ilus
Artículo en Portugués | LILACS, BBO | ID: biblio-1511056

RESUMEN

Introdução: Mesmo com toda evolução tecnológica desses instrumentos, com o desenvolvimento das limas de liga de níquel-titanio (NiTi) e sistemas mecanizados, as fraturas podem ocorrer durante o preparo químico/mecânico. Existem três abordagens mais regulamente aplicadas para solucionar essa intercorrencia: tentativa de remoção do instrumento com ultrassom, tentativa de ultrapassálo (bypass) ou a obturação do segmento. Objetivo: Relatar um caso da técnica de bypass em instrumento fraturado no canal radicular. Descrição do caso: Paciente, sexo feminino, 47 anos, brasileira, sem condições sistêmicas associadas, foi encaminhada à clínica do Curso de Odontologia da UNIFENAS, Divinópolis, Minas Gerais, Brasil, para resolução de fratura de instrumento no canal mésio- vestibular do primeiro molar superior direito (16). Optou-se pelo tratamento pela técnica de bypass, que envolveu as seguintes etapas: anestesia, abertura, utilização de lima C-Pilot #08 para ultrapassar o instrumento fraturado, odontometria, escalonamento regressivo a partir da lima k#20, desinfecção com hipoclorito de sódio 5%, medicação com hidróxido de cálcio por 21 dias, agitação da substância irrigadora e obturação dos canais radiculares. Conclusão: O bypass ao instrumento é uma técnica conservadora, eficaz e uma solução adequada em casos de fratura de limas endodônticas dentro dos canais radiculares. Essa técnica visa preservar o máximo possível da estrutura dental original, evitando procedimentos mais invasivos.(AU)


Introduction: Even with all technological evolution of these instruments, with the development of nickel-titanium alloy (NiTi) files and mechanized systems, fractures can occur during chemical/mechanical preparation. There are three most commonly applie to resolve this complication: attempting to remove the instrument with ultrasound, attempting to bypass it, or obturating the segment. Objective: To report a case of bypass technique in fractured instrument in the root canal. Case description: A 47-year-old female patient from Brazil, with no associated systemic conditions, was referred to the clinic of the Dentistry Course at UNIFENAS, Divinópolis, Minas Gerais, Brazil, for resolution of an instrument fracture in the mesio-vestibular canal of the right upper first molar (16). Treatment was performed using the bypass technique, which involved the following steps: anesthesia, opening, use of a C-Pilot #08 file to bypass the fractured instrument, odontometry, regressive scaling from the k#20 file, disinfection with 5% sodium hypochlorite, medication with calcium hydroxide for 21 days, agitation of the irrigating substance and root canal filling. Conclusion: Instrument bypass is a conservative, effective technique and an adequate solution in cases of endodontic file fracture within root canals. This technique aims to preserve as much of the original tooth structure as possible, avoiding more invasive procedures.(AU)


Asunto(s)
Humanos , Femenino , Persona de Mediana Edad , Tratamiento del Conducto Radicular/instrumentación , Instrumentos Dentales , Cavidad Pulpar/diagnóstico por imagen , Falla de Equipo , Titanio , Radiografía Dental , Resultado del Tratamiento , Níquel
9.
Rev. mex. trastor. aliment ; 13(1): 58-70, ene.-jun. 2023. tab, graf
Artículo en Español | LILACS-Express | LILACS | ID: biblio-1530218

RESUMEN

Resumen Con la finalidad de evaluar la presencia de insatisfacción corporal en jóvenes varones, resulta importante contar con instrumentos adecuados que midan esta insatisfacción y que garanticen resultados válidos. En el Perú y en diversos países, no se cuenta con gran variedad de herramientas apropiadas que midan la insatisfacción de la imagen corporal en varones, por lo que el propósito de la investigación fue adaptar lingüística y psicométricamente el BSQ en un grupo de jóvenes varones universitarios (n=320) de Lima Metropolitana con un rango de edad de 18 a 30 años. Se obtuvo una explicación del 50.72% sobre la variabilidad del instrumento y los resultados mostraron una excelente consistencia interna en ambos factores: 1) Malestar Corporal Normativo (α= .88) y 2) Malestar Corporal Patológico (α= .87). Respecto a la validez convergente y divergente, el BSQ demostró una buena capacidad para determinar la presencia de insatisfacción de la imagen corporal denotando una convergencia positiva y significativa entre ambos factores del BSQ con el Afecto Negativo del SPANAS, explicando como todos estos sentimientos negativos se encuentran presentes e influyen con la aparición de esta incomodidad. Se discuten las limitaciones y recomendaciones del estudio, y la dirección de futuras investigaciones.


Abstract In order to evaluate the presence of corporal dissatisfaction in young men, it is important to have adequate instruments to measure this dissatisfaction and guarantee valid results. However, in Peru and several countries, there is not a great variety of appropriate tools to assess body image dissatisfaction. The present research aimed to adapt the Body Shape Questionnaire (BSQ) to a group of young male university students (N = 320) from Metropolitan Lima with an age range of 18 to 30 years. Results showed a 2-factor structure that explained 50.72% of the total variance. An excellent internal consistency was obtained in both factors: 1) Normative Body Uncomfort (α = .88) and 2) Pathological Body Uncomfort (α = .87). Regarding convergent and divergent validity, the BSQ showed good ability to determine the presence of body image dissatisfaction, denoting a positive and significant convergence between both BSQ factors with the PANAS Negative Affect, explaining how all these negative feelings are present and influence with this discomfort. Finally, the limitations and recommendations of the study, as well as the direction of future research are discussed.

10.
Artículo en Inglés | LILACS-Express | LILACS | ID: biblio-1535289

RESUMEN

Introduction: the in vitro study compared the dynamic cyclic fatigue resistance of 3 reciprocating NiTi files with heat treatment. Methods: we distributed 30 new endodontic files in three groups. The endodontic files selected for this experiment were: AF Blue R3 25/06 (AFB) (Fanta Dental, Shanghai, China), X1 Blue File 25/06 (X1B) (MK Life, Porto Alegre, RS, Brazil), and Reciproc Blue 08/25 (RB) (VDW, Munich, Germany. We measured the time to file fractureand the length of the fractured fragment. ANOVA analysis was used, followed by the Tukey test for multiple comparisons, with a significance level of 5% (P < 0,05). Results: the mean time in seconds until the file fractured was 170.7 ±15,1 for AFB files, 110,4 ±26,8 for X1B, and 163,3 ±22,9 for RB files. This difference was statistically significant when comparing X1B to AFB (p: 0,000) and X1B to RB (p: 0,000). However, there are no statistically significant differences between RB and AFB (p:0,739). Conclussions: this study found that RB and AFB files exhibit similar resistance to cyclic fatigue.


Introducción: el estudio in vitro comparó la resistencia a la fatiga cíclica dinámica de 3 limas NiTi recíprocas con tratamiento térmico. Métodos: distribuimos 30 limas endodónticas nuevas en tres grupos. Las limas endodónticas seleccionadas para este experimento fueron: AF Blue R3 25/06 (AFB) (Fanta Dental, Shanghai, China), X1 Blue File 25/06 (X1B) (MK Life, Porto Alegre, RS, Brasil), y Reciproc Blue 08/25 (RB) (VDW, Munich, Alemania. Se midió el tiempo transcurrido hasta la fractura de la lima y la longitud del fragmento fracturado. Se utilizó el análisis ANOVA, seguido de la prueba de Tukey para comparaciones múltiples, con un nivel de significación del 5% (P < 0.05). Resultados: el tiempo medio en segundos hasta la fractura de la lima fue de 170.7 ±15.1 para las limas AFB, 110.4 ±26.8 para las X1B y 163.3 ±22.9 para las RB. Esta diferencia fue estadísticamente significativa al comparar X1B con AFB (p: 0.000) y X1B con RB (p: 0.000). Sin embargo, no hay diferencias estadísticamente significativas entre RB y AFB (p:0.739). Conclusiones: en este estudio se ha comprobado que las limas RB y AFB presentan una resistencia similar a la fatiga cíclica.

11.
J. res. dent ; 11(1): 7-13, May 2023.
Artículo en Inglés | LILACS-Express | LILACS | ID: biblio-1513029

RESUMEN

NiTi endodontic instruments for glide path are the most susceptible to fractures inside the root canal, mainly as a result of high torsional stress. Objective: The present study investigated the resistance to torsion and angular deflection of instruments destined for the glide path: ProGlider #16.02; T-File #17.02 and the MK Life #16.02. Materials and methods: Thirty rotating NiTi glide path instruments (n=10) with 25mm lengths were selected. The torsion test was performed based on ISO 3630-01 (1992). Three millimeters from the tip of the instruments, it was attached to a small load cell by a lever arm connected to the torsion shaft. Torsional strength and angular deflection were evaluated. Fracture surfaces were examined by scanning electron microscopy with magnifications of 1000x and 5000x in the cross section, and 50x in the lateral section. Statistical analysis was performed using the Kruskal-Wallis H test, followed by the Down's post hoc test. Results: The ProGlider instrument showed greater torsional strength (p<0.05) compared to the T-File (p<0.05) and MK Life (p<0.05), respectively. However, the T-File showed greater angular deflection (p<0.05) than the other groups tested. Conclusion: It can be concluded that the ProGlider instrument presented greater torque for the fracture, while the T-File instrument presented greater angular deflection.

12.
Rev. ADM ; 80(1): 6-10, ene.-feb. 2023. ilus, tab
Artículo en Español | LILACS | ID: biblio-1510346

RESUMEN

Introducción: el material para empaquetar el instrumental odontológico, como pueden ser bolsas de tela, papel o plástico, es usado por profesionales de la salud; sin embargo, es necesario esclarecer la efectividad de cada uno y determinar el tiempo que permanece estéril luego del procedimiento. Objetivo: identificar la eficacia de tela, plástico y papel como materiales para esterilizar instrumental a corto y largo plazo. Material y métodos: se realizaron cultivos sólidos y líquidos de instrumental esterilizado en tres materiales y con diferentes tiempos de postesterilización. Se incubaron a 36 oC por 72 horas en condiciones aerobias y anaerobias. Los resultados se analizaron usando una prueba de Kruskal-Wallis, seguida de una prueba de Dunn. Resultados: los resultados mostraron que inmediatamente después del proceso de esterilización, los tres materiales son efectivos (Kruskal-Wallis test, p = 0.2752), 24 horas (p = 0.2492), siete (p = 0.0509) y 14 días (p = 0.0006). Veinticuatro horas posterior a la esterilización la tela no es efectiva, el plástico disminuye su efectividad y el papel sigue siendo efectivo. Conclusión: en nuestros resultados, el papel es la mejor opción para esterilizar instrumental (AU)


Introduction: material such as cloth, paper or plastic bags to wrap dental instruments is used by health professionals, however, it is necessary to clarify the effectiveness of each one and determine if it remains sterile after the procedure. Objective: to determine the effectiveness of cloth, plastic and paper as materials to sterilize dental instruments in the short and long term. Material and methods: we carry out solid and liquid cultures of sterilized instruments in three materials, at different post-sterilization times, incubated at 36 oC for 72 hours under aerobic and anaerobic conditions, and the results were analyzed using a Kruskal-Wallis test, followed by from a Dunn's test. Results: our results showed that immediately after the sterilization process the three materials are effective (Kruskal-Wallis; p = 0.2752), 24 hours (p = 0.2492), 7 (p = 0.0509) and 14 (p = 0.0006) days. Twenty-four hours after the cloth is not effective, plastic decreases its effectiveness and paper remain effective. Conclusion: in our results, paper is the best option to sterilize dental instruments (AU)


Asunto(s)
Esterilización/métodos , Instrumentos Dentales/microbiología , Papel , Plásticos , Textiles , Tiempo , Efectividad , Recuento de Colonia Microbiana/métodos , Estadísticas no Paramétricas , Embalaje de Productos/instrumentación , Medios de Cultivo
13.
Journal of Prevention and Treatment for Stomatological Diseases ; (12): 381-388, 2023.
Artículo en Chino | WPRIM | ID: wpr-964429

RESUMEN

@#With the development of computer-aided surgery and rapid prototyping via 3D printing technology, digital surgery has rapidly advanced in clinical practice, especially in the field of oral and maxillofacial surgery. 3D printing technology has been applied to the functional restoration and reconstruction of the jawbone. Before surgery, a 3D digital model is constructed through software to plan the scope of the osteotomy, shape the bone graft and plan the placement of the implant. Additionally, 3D models of personalized surgical instrument guides are printed prior to surgery. With these 3D-printed models and guides, accurate excision of the jaw tumor, accurate placement of the grafted bone and precise placement of implants can be achieved during surgery. Postoperative evaluation of accuracy and function shows that 3D printing technology can aid in achieving the biomechanical goals of simultaneous implant placement in jaw reconstruction, and in combination with dental implant restoration, the technology can improve patients' postoperative occlusal and masticatory functions. Nevertheless, 3D printing technology still has limitations, such as time-consuming preparation before surgery. In the future, further development of 3D printing technology, optimization of surgical plans, and alternative biological materials are needed. Based on domestic and foreign literature and our research results, we have reviewed the process and clinical application prospects of jaw reconstruction via 3D printing technology to provide a reference for oral and maxillofacial surgeons.

14.
Chinese Journal of Medical Instrumentation ; (6): 252-257, 2023.
Artículo en Chino | WPRIM | ID: wpr-982223

RESUMEN

Based on the joint analysis of EMG spectrum and amplitude method (JASA), a study on muscle fatigue assessment of spinal surgical instruments based on surface EMG signals was carried out, and a comparative evaluation of the operating comfort before and after the optimization of spinal surgical instruments was completed. A total of 17 subjects were recruited to collect the surface EMG signals of their brachioradialis and biceps. Five surgical instruments before and after optimization were selected for data comparison, and the operating fatigue time proportion of each group of instruments under the same task was calculated based on the RMS and MF eigenvalues. The results showed that when completing the same operation task, the operation fatigue time of the surgical instruments before optimization was significantly higher than that after optimization (P<0.05); there was no significant difference in the fatigue status of brachioradialis and biceps when operating the same instrument (P>0.05). These results provide objective data and reference for the ergonomic design of surgical instruments and fatigue damage protection.


Asunto(s)
Humanos , Fatiga Muscular/fisiología , Músculo Esquelético , Electromiografía , Ergonomía
15.
Chinese Journal of Blood Transfusion ; (12): 218-221, 2023.
Artículo en Chino | WPRIM | ID: wpr-1005125

RESUMEN

【Objective】 To explore the significance of blending internal controls by automatic sample processing instruments in the enzyme linked immunosorbent assay (ELISA). 【Methods】 The internal controls were vortexed and mixed before the test, and then were added to the same ELISA plate by the STAR automatic sample processing instruments under the same detection conditions. The difference of S/CO value of internal controls with and without sufficient blending via the sampling needle and their frequency distribution were compared. Internal controls that were greatly affected by mixing parameters were submitted to the same test with different batches of reagents from the same manufacturer, and the results were analyzed for consistency. 【Results】 The S/CO value of anti-HCV internal controls without blending using adding sample needle was significantly lower than that of quality control samples with sufficient blending (P<0.000 1). The S/CO values of unmixed internal controls concerning anti-TP and anti-HIV detection given by some detection systems were also different from the values of mixed internal controls (P<0.05). Some of the S/CO values of the anti-HCV internal controls without mixing were distributed within the interval of less than 2. Different batches of reagents from the same manufacturer were used to detect anti-HCV internal controls, and there were differences in the partial detection values between the mixed and unmixed internal controls (P<0.05). 【Conclusion】 Although the internal controls were mixed by vortex shock before the test, the detection results of some internal controls will still be affected when the STAR automatic sample processing instruments does not set the mixing parameters for internal controls.

16.
Chinese Journal of School Health ; (12): 1614-1617, 2023.
Artículo en Chino | WPRIM | ID: wpr-998786

RESUMEN

Objective@#To explore the structural status of school sexuality education policies in China, so as to provide a reference to optimize their effectiveness and development.@*Methods@#A total of 45 policy documents closely related to school sexuality education, released at the national level, as samples in order to construct an analytic framework of policy objectives/instruments by analyzing their textual content.@*Results@#In terms of policy objectives, school sexuality education policies focused on educational methods guidance (32.76%), and tend to underestimate the evaluation of educational effects (5.17%) and the protection of teachers and students rights and interests (5.17%), while failed to consider the creation of educational environments (0). In regards to policy tools, school sexuality education policies often used command line tools (59.45%) and capacity building tools ( 29.71% ), while the use of system change tools (2.70%) and incentive tools was lacking (0). In respect to the adaptability of policy objectives/tools, school sexuality education policies focused on using command based tools to guide educational methods ( 68.42% ), educational process management (54.55%), student literacy improvement (38.46%), and educational resource development ( 37.50% ). However, system change tools and incentive tools were scarcely used to achieve policy goals in education effectiveness evaluation, to protect teacher student rights and interests, and to improve student literacy and comprehensive social governance.@*Conclusions@#There is some deviations in the positioning of policy objectives, the selection of policy tools, and the interaction and adaptation between the two in school sex education policies, and further improvement is needed.

17.
Cancer Research and Clinic ; (6): 23-28, 2023.
Artículo en Chino | WPRIM | ID: wpr-996181

RESUMEN

Objective:To investigate the differences between the mental clips placed intraoperatively and the tumor bed's target volume delineation of seroma based on CT scanning during radiotherapy for breast cancer patients who received breast-conserving surgery in the persuit of a better solution to determine the tumor bed position.Methods:The clinical data of 13 patients with early breast cancer who received postoperative radiotherapy after breast-conserving surgery at Beijing Shijingshan Hospital and Beijing Shijitan Hospital of Capital Medical University from December 2020 to January 2022 were retrospectively analyzed. They all had surgical clips implanted during the surgery. The following methods were used to delineate the target volume of tumor bed, including gross target volume delineation of tumor bed based on the mental clips (GTVtb-Clip), the tumor bed's gross target volume delineation of seroma based on CT scanning (GTVtb-Seroma), and the combination of both (GTVtb-C+S). The volume, diameter on three coordinate axis, neutral point displacement and conformability of these delineation methods were compared.Results:The volume of GTVtb-Clip, GTVtb-Seroma and GTVtb-C+S was (25±10) cm 3, (38±17) cm 3, (49±20) cm 3, and the differences were statistically significant (all P<0.05). The diameter on X axis was (4.7±1.2) cm, (5.3±1.4) cm, (5.7±1.6) cm, respectively in GTVtb-Clip, GTVtb-Seroma and GTVtb-C+S; the diameter on Y axis was (4.6±1.7) cm, (5.0±1.6) cm, (5.7±1.7) cm, respectively in GTVtb-Clip, GTVtb-Seroma and GTVtb-C+S; the diameter on Z axis was (4.4±1.5) cm, (5.2±1.4) cm, (5.6±1.4) cm in GTVtb-Clip, GTVtb-Seroma and GTVtb-C+S. The differences in the diameter of GTVtb-Clip and GTVtb-C+S on X,Y, Z axis were statistically significant (all P<0.05); the differences in the diameter of GTVtb-Seroma and GTVtb-C+S on X, Z axis were statistically significant (all P<0.05); the difference in the diameter of GTVtb-Clip and GTVtb-Seroma on X axis was statistically significant ( P<0.05) .Neutral point displacement was (5.8±1.6) cm, (5.5±1.9) cm, (6.0±1.7) cm, respectively of GTVtb-Clip, GTVtb-Seroma, GTVtb-C+S, and the difference was not statistically significant ( P>0.05). Conformability of GTVtb-Clip and GTVtb-Seroma, GTVtb-Clip and GTVtb-C+S, GTVtb-Seroma and GTVtb-C+S was 0.412±0.112, 0.525±0.095, 0.774±0.112,respectively, and the differences were statistically significant (all P<0.05). Conclusions:During radiotherapy after breast-conserving surgery for breast cancer, compared with the single method, the combination of GTVtb-Clip and GTVtb-Seroma can better cover the real tumor bed, thus reducing the omission of tumor bed and recurrence rate. CT position should better take place at 4 to 8 weeks for patients receiving radiotherapy after breast-conserving surgery, and target volume of tumor bed will be delineated based on the postoperative changes of both mental clips and seroma.

18.
Chinese Journal of Hospital Administration ; (12): 404-410, 2023.
Artículo en Chino | WPRIM | ID: wpr-996098

RESUMEN

Objective:To analyze the evolution of China′s national-level healthcare sector regulatory policies between 2003 and 2021, and explore the characteristics and patterns of the use of policy instruments at different stages, for references in policy optimization.Methods:The policy documents related to the regulation of the healthcare sector released by the central government were searched from 2003 to 2021 from the policy document database of the State Council using the keywords " medical" " regulation" and " health" " regulation". Based on the analysis framework of " formulation subject-implementation subject-policy tools", such methods as content analysis, social network analysis, and policy tool analysis were used to analyze policy documents and conduct descriptive analysis of data.Results:A total of 236 policies were included in the study.From 2003 to 2008, according to the time progression, a total of 27 documents were issued, with the State Council as the main formulation subject (77.78%, 21/27), and the government as the main implementation subject (100.00%, 27/27). 191 policy tools were used, and the composition ratios of supply-based, demand-based, and environment-based policy instruments were 21.46% (41/191), 30.37% (58/191), and 48.17% (92/191). From 2009 to 2017, a total of 48 policies were issued, the formulation subject was mostly the State Council (93.75%, 45/48), and the implementation subject was still mostly the government (100.00%, 48/48), but the proportion of institutions (25.00%, 12/48), industry organizations (43.75%, 21/48) and the society (37.50%, 18/48) has increased. 500 policy tools were used, and the composition ratios of supply-based, demand-based, and environment-based policy instruments were 17.40% (87/500), 32.00% (160/500), and 50.60% (253/500), respectively.From 2018 to 2021, a total of 161 documents were issued, with the formulation subjects featuring multiple subjects (38.51%, 62/161), with a decrease in the percentage of the State Council′s issuance (22.36%, 36/161), and 157 (97.52%) policies were implemented by the government. 1 140 policy tools were used, and the composition ratios of supply-based, demand-based, and environment-based policy instruments being 18.42% (210/1 140), 34.74% (396/1 140), and 46.84% (534/1 140), respectively.Conclusions:From 2003 to 2021, there was an upward trend in the number of policies issued in the field of healthcare sector regulation in China, and the subjects of formulation and implementation were diversified. But the use of different types of policy instruments was uneven.

19.
Chinese Journal of Laboratory Medicine ; (12): 113-118, 2023.
Artículo en Chino | WPRIM | ID: wpr-995706

RESUMEN

Insect-borne infections are causing serious public health concerns worldwide. Point-of-care testing technology for insect-borne diseases can rapidly and accurately determine the pathogens, thus it plays an important role in the application of portable disease control measurements. This article provides an overview of the point-of-care testing technology for insect-borne infectious diseases regarding its application, advantages and limitations in experimental diagnoses, and its future trends.

20.
Chinese Journal of Primary Medicine and Pharmacy ; (12): 1056-1060, 2023.
Artículo en Chino | WPRIM | ID: wpr-991866

RESUMEN

Objective:To investigate the application effects of self-developed rapid tracheotomy apparatus for acute tracheotomy.Methods:A total of 120 patients who underwent an acute tracheotomy in the Weihai Branch of The 970 Hospital of PLA Joint Logistics Support Force from January 2019 to December 2020 were included in this study. These patients were randomly divided into a rapid group and a conventional group, with 60 patients in each group. Patients in the rapid group underwent tracheotomy with a self-developed rapid tracheotomy apparatus. Patients in the conventional group underwent the standard steps of traditional tracheostomy. The operation time, incision length, amount of bleeding, and incidence of postoperative complications were compared between the two groups.Results:The operation time in the rapid group was significantly shorter than that in the conventional group [(4.5 ± 0.9) minutes vs. (19.3 ± 4.7) minutes, t = 23.86, P < 0.001]. The length of incision in the rapid group was significantly shorter than that in the conventional group [(2.8 ± 0.3) cm vs. (4.2 ± 1.3) cm, t = 8.68, P < 0.001]. The amount of bleeding during the surgery in the rapid group was significantly less than that in the conventional group [(4.4 ± 1.6) mL vs. (11.8 ± 4.1) mL, t = 12.99, P < 0.001]. The incidence of postoperative complications in the rapid group was significantly lower than that in the conventional group ( χ2 = 4.66, P = 0.031). Conclusion:The self-developed rapid tracheotomy apparatus for acute tracheotomy can be used to establish an artificial airway quickly and minimally invasively by simplifying the operational steps. It is remarkably innovative to increase safety with open-view operations and decrease the incidence of complications. It can be repeatedly sterilized and reused, which is worthy of clinical application and popularization.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA