Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Añadir filtros








Intervalo de año
1.
Journal of Xi'an Jiaotong University(Medical Sciences) ; (6): 438-442, 2021.
Artículo en Chino | WPRIM | ID: wpr-1006723

RESUMEN

【Objective】 To investigate setup and respiratory movement residual error with the guidance of online four-dimensional cone beam computed tomography (4DCBCT) and the impact on margins required to internal target volume (ITV) margin during stereotactic body radiotherapy (SBRT) of lung tumor in the middle or lower lobe. 【Methods】 Twenty SBRT treatment patients with lung tumor in the middle or lower lobe were enrolled for treatment residual error retrospective analysis. Thermoplastic masks were used as immobilization devices during SBRT treatment. ITV was determined by 4DCBCT simulation. A total of 76 4DCBCT scans before the treatment were recorded to determine the setup and respiratory residual error for ITV margins. 【Results】 The setup and respiratory movement error were significantly reduced with the guidance of online 4DCBCT during radiotherapy. The setup residual errors were respectively (0.07±0.12)cm, (0.03±0.29)cm and (0.04±0.14)cm in right-left (RL), superior-inferior (SI) directions and anterior-posterior (AP) directions. The respiratory movement residual errors were respectively (-0.06±0.07)cm, (0.02±0.26)cm and (0.02±0.11)cm in RL, AP, and SI directions. Based on setup and respiratory movement residual errors, the PTV margins of NSCLC were reduced from 1.13 cm, 2.15 cm and 0.90 cm to 0.50 cm, 0.59 cm and 0.56 cm in RL, AP and SI directions, respectively, calculated with recipe by VanHerk. 【Conclusion】 With the guidance of online 4DCBCT, the setup and respiratory movement residual error cannot be ignored during SBRT of lung tumor in the middle or lower lobe. The ITV margin required after online 4DCBCT correction for the patients enrolled in the study would be approximatively 0.6 cm around to ensure an accurate dose to the target tumor and reduce the dose to normal tissues.

2.
Chinese Journal of Radiation Oncology ; (6): 1054-1058, 2021.
Artículo en Chino | WPRIM | ID: wpr-910513

RESUMEN

Objective:To analyze the influence of tracking error of Xsight lung tracking system caused by cardiac beating.Methods:48 patients with lung tumors adjacent to the heart were enrolled into this study. The tumor movement curves were collected by the Xsight lung tracking system and recorded in the treatment log files during the Cyberknife treatment process. The curves were subject to filtering analysis and the respiratory motion of < 1 Hz and the cardiac beating motion of > 1 Hz were separated. According to the filtering results, the patient treatment tracking data were divided into two groups based on whether the cardiac beating wave of >1 Hz existed. The tracking errors were statistically compared between two groups based on the X-ray imaging data collected by Xsight lung tracking system during treatment.Results:For the fractionation with cardiac beat information, the tracking errors of the patient′s related models were (1.45 ± 0.99), (0.46 ± 0.21) and (0.70 ± 0.54) mm in the left-right, superior-inferior and anterior-posterior direction, respectively. For the fractionation without cardiac beat information, the tracking errors of the patient′s related models were (1.52 ± 1.17), (0.63 ± 0.37) and (1.07 ± 0.62) mm in the left-right, superior-inferior and anterior-posterior direction, respectively. The tracking errors in the superior-inferior and anterior-posterior direction of patients with accurate cardiac beat models were 28.34% and 34.86% less than those of their counterparts without accurate cardiac beat models and there was significant difference (both P<0.05). Conclusion:The tracking accuracy of Xsight lung tracking system will be significantly improved if the cardiac beat model is accurately established.

3.
Chinese Journal of Radiation Oncology ; (6): 688-692, 2015.
Artículo en Chino | WPRIM | ID: wpr-481671

RESUMEN

Objective To study the geometric difference between six different ITV generation methods from 4DCT for patients with non?small cell lung cancer ( NSCLC) treated with stereotactic ablative radiotherapy technique ( SABR) . Methods Between Dec. 2013 and Mar. 2014,16 patients were enrolled in this retrospective study. All patients underwent imaging with 4DCT scans. The MI and DI index were evaluated between six ITV generation methods:combining GTV from all 10 respiratory phases ( ITV10 );combining GTV from four respiratory phases, including two extreme phases ( 0% and 50%) plus two intermediate phases ( 20% and 70%) ( ITVYeo ) which was proposed by Seung?Gu Yeo of Soonchunhyang University;combining GTV from two extreme phases ( ITVEI+EE ) . And combining GTV from five odd phases (10%,30%,50%,70%,90%)(ITVodd).Accordingly the ITVEVEN which was combined from the remaining five even phases (20%,40%,60%,80%,0%),and ITVAVG,ITVMIP were contoured from two reconstructed 4DCT sequences,finally,a method which was not sensitive to the tumor volume and motion characteristic was selected for clinical use. Data were compared using a variance analysis followed by Student?Newman?Keulsa test both in same group or between groups. At the same time, the volume and the three dimensional movements of the tumor, the relativity of MI and DI were analyzed by Multi?parameter regression analysis. Results The mean (range) tumor motion (RLR,RAP,RCC,and R3D) are 3. 5 mm (1. 4?8. 4 mm),4. 5 mm (1. 1?8. 6 mm),9. 5 mm (0?10 mm),12. 3 mm (2. 5?55. 3 mm) respectively. The IGTVx volume are Underestimated by 25. 7%,35. 6%,17. 9%,12. 8%,3. 6%,4. 8%( P=0. 000) respectively. The MI index comparisons between six ITV generation methods and ITV10 showed statistical significance:0. 69,0. 62,0. 80, 0. 86,0. 93,0. 91 ( P=0. 006 ) . The DI index showed no statistical significance:0. 98, 0. 98, 0. 97, 0. 97, 0. 99,0. 98(P=0. 130).The tumor size and motion amplitude were certified not the independent factors for the MI index of ITVodd and ITVEVEN . Conclusions IGTVODD/EVEN based on odd or even 4DCT phases is not sensitive to the tumor size or motion characteristic and is proved to have a good marching with ITV10 meanwhile maintaining a reasonable contouring efficiency,it can be recommend to the institutions which was not equipped with the deformable registration systems.

4.
Chinese Journal of Radiation Oncology ; (6): 556-559, 2015.
Artículo en Chino | WPRIM | ID: wpr-476433

RESUMEN

Objective To explore the influence of different reconstruction modes with time?weighted respiratory phases on the internal tumor volume ( ITV) of solitary pulmonary lesion ( SPL) , and to evaluate the feasibilities of 8 and 4 equal time?weighted respiratory phases in 4DCT simulation. Methods 24 patients with SPL underwent 4D scanning. Images were reconstructed with 10, 8 and 4 equal time?weighted phases of the respiratory cycles, respectively. Gross tumor volumes ( GTVs ) were delineated on the three sets of reconstructed images and fused into ITVs, which were ITV10 , ITV8 and ITV4 respectively. The differences of volumes, centroid of the ITVs and motions of GTV centroids in three?dimensional directions were compared. Statistical analysis was performed using the Friedman M test. Results The volumes of ITV10 , ITV8 and ITV4 were (9.09±12?29) cm3,(9.10±12?47) cm3 and (8.98±12?61) cm3(P=0?001), respectively. There were no differences between the volumes of ITV10 and ITV8 after the Bonferroni correction ( P=0?721) , while the opposite between those of ITV10 and ITV4 ( P=0?002 ) . The differences of centroid positions of ITV10, ITV8 and ITV4 in x?, y?and z?axes were all less than 1 mm ((12.22±7?71),(12.23± 7?71),(12.22±7?71),Px =0?668);(43.30±29?38),(43.30±29?40),(43.31±29?39),Py =0?643;(5.66±3?67),(5.66±3?67),(5.66±3?67),Pz=0?878), similar to the motions of GTV centroids in three reconstructed modes ((0.69±0?56),(0.69±0?68),(0.79±0?51) mm,Px=0?356;(3.13±3?78),(3.13± 4?05),(3.19±4?06) mm,Py =0?978;(1.18±1?31),(1.03±1?32),(1.16±1?34) mm,Pz=0?302). Conclusions There were no differences in volumes, centroid positions and motions between ITV10 and ITV8 . The quantity of reconstruction images and GTV delineations according to 8 time?weighted phases were both less than conventional 10 phases. 8 time?weighted respiratory phases mode was feasible in 4DCT simulation for SPL.

5.
Chinese Journal of Radiation Oncology ; (6): 80-83, 2013.
Artículo en Chino | WPRIM | ID: wpr-431159

RESUMEN

Objective To study preliminary the accuracy of clinical target volume (CTV) and internal target volume (ITV) automatically generated by an in-house deformable registration software on fourdimensional CT (4DCT),and evaluate its feasibility of clinical application.Methods Clinic treated one lung cancer patient and one liver cancer patient were selected for the study.CTV was delineated by radiation oncologist according to a single respiratory phase image of 4DCT scanning,and then deformed to the other phases and generated the CTVdefm on each phase image.Differences between the CTVdefm and CTVmanu were then compared.A composite ITVcopm was created by overlapping all the CTVdefm of 10 phases and compared with the ITVMIP which was contoured on the maximum intensity projection (MIP) CT images,including the shape,volume and geometric center position of the ITV contour.Results For the tested lung case,average volume difference between the CTVdefm and CTV was (-2.59 ± 5.02)% for the all 10 phases,and the vector departure of the two ITV centers was (1.04 ± 0.89) mm.The ITVcomp almost completely matched the ITVMIP on the tested liver case with a volume difference smaller the 1% and only 1.4 mm vector departure between their geometric centers.Conclusion The validity of the CTVdefm and ITVcomp gained from automatic deformation of manual delineation reference based on 4DCT images were preliminary evaluated and proved to be good enough for clinic planning.

6.
Radiation Oncology Journal ; : 247-251, 2013.
Artículo en Inglés | WPRIM | ID: wpr-115560

RESUMEN

PURPOSE: This study aimed to investigate efficient approaches for determining internal target volume (ITV) from four-dimensional computed tomography (4D CT) images used in stereotactic body radiotherapy (SBRT) for patients with early-stage non-small cell lung cancer (NSCLC). MATERIALS AND METHODS: 4D CT images were analyzed for 15 patients who received SBRT for stage I NSCLC. Three different ITVs were determined as follows: combining clinical target volume (CTV) from all 10 respiratory phases (ITV10Phases); combining CTV from four respiratory phases, including two extreme phases (0% and 50%) plus two intermediate phases (20% and 70%) (ITV4Phases); and combining CTV from two extreme phases (ITV2Phases). The matching index (MI) of ITV4Phases and ITV2Phases was defined as the ratio of ITV4Phases and ITV2Phases, respectively, to the ITV10Phases. The tumor motion index (TMI) was defined as the ratio of ITV10Phases to CTVmean, which was the mean of 10 CTVs delineated on 10 respiratory phases. RESULTS: The ITVs were significantly different in the order of ITV10Phases, ITV4Phases, and ITV2Phases (all p < 0.05). The MI of ITV4Phases was significantly higher than that of ITV2Phases (p < 0.001). The MI of ITV4Phases was inversely related to TMI (r = -0.569, p = 0.034). In a subgroup with low TMI (n = 7), ITV4Phases was not statistically different from ITV10Phases (p = 0.192) and its MI was significantly higher than that of ITV2Phases (p = 0.016). CONCLUSION: The ITV4Phases may be an efficient approach alternative to optimal ITV10Phases in SBRT for early-stage NSCLC with less tumor motion.


Asunto(s)
Humanos , Carcinoma de Pulmón de Células no Pequeñas , Tomografía Computarizada Cuatridimensional , Neoplasias Pulmonares , Pulmón , Radiocirugia , Radioterapia
7.
Korean Journal of Medical Physics ; : 263-268, 2008.
Artículo en Coreano | WPRIM | ID: wpr-93132

RESUMEN

The application of a respiratory gated radiotherpy method to the lung radiation surgery was evaluated compared with the conventional method in which the whole tumor motion range is considered in the delineation of PTV (Planning target volume). The four dimensional CT simulation images were acquired for the five NSCLC (Non-small cell lung cancer) patients for radiation surgery. The respiratory gated plan was prepared with the 50% phase CT images and the conventional method was planned based on the ITV (Internal target volume) which include all the target volumes created in each phase CT images within a whole respiratory period. The DVH (Dose volume histogram) of OAR (Organ at risk) which calculated in each method was compared for the evaluation of the plan properness. The relative decrease of OARs' DVH were verified in the application of respiratory gated method. The average decrease rate were 16.88+/-9.97% in the bronchus, 34.13+/-19.15% in the spinal cord, 28.42+/-18.49% in the chest wall and 32.48+/-16.66% in the lung. Based on these results, we can verified the applicability and the effectiveness of the respiratory gated method in the lung radiation surgery.


Asunto(s)
Humanos , Bronquios , Tomografía Computarizada Cuatridimensional , Pulmón , Médula Espinal , Pared Torácica
SELECCIÓN DE REFERENCIAS