Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Añadir filtros








Intervalo de año
1.
São José dos Campos; s.n; 2022. 104 p. tab, ilus, graf.
Tesis en Portugués | LILACS, BBO | ID: biblio-1396533

RESUMEN

O objetivo deste estudo foi avaliar in vitro a influência de um novo dispositivo fotopolimerização e pino de fibra de vidro nas propriedades mecânicas, físicoquímicas e adesão dos cimentos resinosos. Foram utilizados oitenta dentes bovinos, submetidos ao tratamento endodôntico, distribuídos em 5 grupos (n=16): CD (Pino fibra vidro e cimento dual); PF (Pino perfurado e cimento fotoativado); PD (Pino perfurado e cimento dual); POF (Pino perfurado iluminador de fibra óptica e cimento fotoativado); POD (Pino perfurado iluminador de fibra óptica e cimento dual). Os dentes foram preparados para colocação de um protótipo de pino em fibra de vidro que possui um canal interno de diâmetro regular e com conicidade progressiva. A perfuração permite a inserção da fibra óptica ao longo da extensão do pino a fim de possibilitar a ação da luz ao longo de todo o comprimento do conduto radicular. Após a cimentação, os espécimes foram seccionados perpendicularmente, e obtida 1 fatia de 2 mm de espessura do terço apical, médio e cervical. A avaliação mecânica foi realizada através do ensaio de push-out para determinação da resistência adesiva nos terços cervical, médio e apical seguido pela análise da fratura em estereomicroscópio. Os retentores intrarradiculares foram também submetidos ao teste de flexão de 3 pontos para análise do material preenchedor do pino de fibra (n=10). As análises físico - químicas foram realizadas através da determinação do grau de conversão dos cimentos (RAMAN) e análise em espectroscopia de energia dispersiva (EDS) dos monômeros presentes. A adesão foi analisada pela interface de cimentação pelo MEV e reconstrução 3D do novo sistema através do Micro-CT. Os dados obtidos foram analisados estatisticamente pelo ANOVA (um e dois fatores) e comparação múltipla de Tukey, (p<0,05). Os resultados de resistência adesiva evidenciaram que o terço apical obteve o maior valor de resistência adesiva em comparação ao terço médio (p<0,001), o grupo POD do terço apical foi estatisticamente significante em relação ao grupo CD do terço médio (p<0,001). Na analise individual de cada terço, não houve diferença entre os grupos experimentais e o controle (p>0,05). A falha adesiva entre cimento e dentina foi a mais predominante entre todos os grupos e terços. O pino de fibra de vidro (controle) obteve o maior valor de resistência à flexão (p<0,001), seguido do pino de fibra de vidro perfurado preenchido com cimento resinoso (p<0,001). Os maiores valores de GC foram alcançados pelo grupo POD com 82,3% (cervical) 69,9 % (médio) e 76,21% (apical) e o EDS comprovou a presença de componentes químicos adequados. A análise da adesão do novo pino de fibra de vidro comprova uma excelente adaptação no interior do canal radicular nas regiões cervical, médio e apical. Portanto o novo dispositivo com fibra óptica e pino de fibra de vidro experimental aumentaram as propriedades mecânicas, físico-químicas e adesão do cimento resinoso (AU)


The aim of this study was to evaluate in vitro the influence of a new light curing device with optical fiber and experimental glass fiber post on the physicochemical, mechanical, and adhesion properties of resin cements. Eighty bovine teeth were used, submitted to an endodontic treatment, distributed in 5 groups (n=16): CD (Glass fiber post and dual cement); PF (Perforated post and light-cured cement); PD (Perforated post and dual cement); POF (Fiber optic illuminating with a perforated post and lightcured cement); POD (Fiber optic illuminating with a perforated post and dual cement). The teeth were prepared for placement of a glass fiber post prototype, which has an internal canal of regular diameter and progressive taper. The internal perforation extension allows the insertion of the optical fiber along the entire length of the post in order to allow the action of light along the entire length of the root canal.The specimens were sectioned perpendicularly for the tests, and 1 slice approximately 2 mm thick was obtained from the apical, middle and cervical thirds. The mechanical evaluation was carried out through the push-out test to determine the adhesive bond strength, in the cervical, middle and apical thirds, followed by the fracture analysis under a stereomicroscope, the intraradicular post were also submitted to the 3-point bending test for material analys of the fiber post filler (n=10). The physicochemical analyzes were performed by determining the degree of conversion of the cements (RAMAN) of each sample and the analysis of energy dispersive spectroscopy (EDS) of the monomers present. Adhesion was analyzed by the cementation interface and 3D reconstruction of the new system through micro-CT, and finally, SEM analysis of the adhesive interface. The data obtained were analyzed for normality and statistically by ANOVA (one and two ways) and Tukey's multiple comparison (p<0.05). The adhesive bond strength results showed that the apical third had the highest value of adhesive strength compared to the middle third (p<0.001), and the POD group of the apical third was statistically significant in relation to the CD group of the middle third (p<0.001). In the individual analysis of each third, there was no difference between the experimental and control groups (p>0.05). Adhesive failure between cement and dentin was the most prevalent among all groups and thirds. The conventional post (control) had the highest flexural strength value (p<0.001), followed by the perforated fiberglass post filled with resin cement (p<0.001). The POD group achieved the highest GC values with 82.3% (cervical), 69.9% (medium), and 76.21% (apical) and EDS confirmed the presence of adequate chemical components. The analysis of the adhesion of the new fiberglass post proves an excellent adaptation inside the root canal in the cervical, middle and apical regions. Therefore, the new light curing device with optical fiber and experimental glass fiber post improved the resin cement's mechanical, phycochemical, and adhesion. (AU)


Asunto(s)
Animales , Bovinos , Análisis de Varianza , Técnica de Perno Muñón , Cementos de Resina , Luces de Curación Dental , Resistencia Flexional , Pruebas Mecánicas
2.
Artículo en Portugués | LILACS | ID: biblio-1526380

RESUMEN

Objetivo: realizar uma revisão de literatura narrativa sobre a importância e a influência do efeito férula na resistência à fratura de restaurações em dentes tratados endodonticamente com utilização ou não de retentores intrarradiculares. Metodologia: Foram utilizados os seguintes descritores indexados no DeCS (Descritores em Ciências da Saúde): "Férula", Prótese Dentária", "Falha da Restauração Dentária", "Técnica de Retentor Intrarradicular" e "Pinos de Retenção Dentária" para busca nas bases de dados PubMed, Embase, Lilacs, Web of Science, Scopus e Cochrane Library. Resultados: Os dados da maioria dos estudos in vitro ou in vivo incluídos nesta revisão sugerem o uso da férula para aumento da resistência à fratura e longevidade dos dentes tratados endodonticamente. Tem sido recomendada a confecção de uma férula com altura uniforme de 2 mm e espessura superior a 1,5 mm. Conclusão: O uso de retentores radiculares foi indicado pela maioria dos trabalhos, sendo geralmente recomendados os pinos de fibra de vidro ao invés de núcleos metálicos fundidos para minimizar os riscos de fratura radicular em razão do módulo de elasticidade semelhante à dentina, além de possibilidade de retratamentos em casos de falhas adesivas. Apesar disso, ainda são necessários estudos clínicos com acompanhamento a longo prazo para avaliar a longevidade das restaurações de dentes tratados endodonticamente utilizando pinos de fibra de vidro sem ou com a presença de férula em diferentes espessuras e alturas.


Objective: This study aimed to conduct a narrative literature review on the importance and influence of the ferrule effect on the fracture resistance of restorations in endodon-tically treated teeth with or without the use of intraradicular posts. Methodology: The following descriptors indexed in the DeCS (Health Sciences Descriptors) were used: "Ferrule", Dental Prosthesis", "Dental Restoration Failure", "Post and Core Technique", and "Dental Posts", to search on the databases of PubMed, Embase, Lilacs, Web of Science, Scopus, and Cochrane Library data. Results: Data from most of the in vitro or in vivo studies included in this review suggest the use of the ferrule to increase fracture resistance and longevity of endodontically treated teeth. It has been recommended to make a ferrule with a uniform height of 2 mm and a thickness greater than 1.5 mm. Conclusion: The use of intraradicular posts was indicated by most studies, and fiberglass posts are generally recommended instead of cast metal cores to minimize the risk of root fracture due to the modulus of elasticity similar to dentin, in addition to the possibility of retreatments in ad-hesive failure cases. Despite this, clinical studies with a long-term follow-up are essential to evaluating the longevity of restorations of endodontically treated teeth using fiberglass posts without or with the presence of ferrule in different thicknesses and heights.


Asunto(s)
Ferulas Periodontales , Técnica de Perno Muñón , Técnica de Perno Muñón/tendencias , Fracaso de la Restauración Dental
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA