1.
Laboratory Medicine Online ; : 1-5, 2013.
Artículo en Coreano | WPRIM | ID: wpr-170617

RESUMEN

BACKGROUND: Autoanalyzer ADVIA2120 uses intracellular peroxidase concentration to perform white blood cell (WBC) differential. Therefore, in specimens containing neutrophils with low peroxidase concentration, neutrophils can be miscounted as monocytes or large unstained cells resulting in pseudoneutropenia. Myeloperoxidase deficiency can be detected by the mean peroxidase index (MPXI). The aims of this study are to establish the reference interval of MPXI and define a cut off value for manual slide review to discriminate pseudoneutropenia. METHODS: We calculated reference intervals as mean+/-2SD according to the indirect method of CLSI C28-A3 guideline from MPXI data of 5,802 individuals who took routine health checkup from April 2010 to June 2012. We performed manual slide review on specimens with low MPXI and compared neutrophil differential count of manual method with that of autoanalyzer. When neutrophil differential in manual slide review was >20%P higher than autoanalyzer result, it was regarded as a pseudoneutropenia. We performed ROC analysis using the MPXI results of samples with and without pseudoneutropenia to define a cutoff to discriminate pseudoneutropenia. RESULTS: The reference intervals of MPXI in total population, male, and female were -4.9 to 7.5, -5.5 to 7.3, and -4.5 to 7.5, respectively. The mean value of MPXI was significantly higher in female than in male and there was no difference by age. Twenty-two pseudoneutropenia samples from 7 patients were identified. ROC analysis yielded cutoff value of -20.7 with 94.9% of sensitivity and 77.3% of specificity. CONCLUSIONS: MPXI may be used in the manual slide review guideline for detecting pseudoneutropenia.


Asunto(s)
Femenino , Humanos , Masculino , Discriminación en Psicología , Leucocitos , Errores Innatos del Metabolismo , Monocitos , Neutrófilos , Peroxidasa , Curva ROC
2.
The Korean Journal of Laboratory Medicine ; : 559-566, 2010.
Artículo en Coreano | WPRIM | ID: wpr-108485

RESUMEN

BACKGROUND: Manual slide review (MSR) is usually triggered by the results of automated hematolgy analyzers, but each laboaratory has different ciriteria for MSR. This study was carried out to investigate the current status of MSR criteria of automated complete blood cell count (CBC) and white blood cell (WBC) differential results and to propose a basic guideline for MSR. METHODS: Total 111 laboratories were surveyed regarding MSR using questionnaires. The questionnaire asked: kinds of automated hematology analyzers used and the presence of criteria triggering MSR in seven categories: 1) CBC results, 2) 5 differential WBC counts, 3) 3 differential WBC counts, 4) automated reticulocyte counts, 5) delta check, 6) instrument flags (or messages), 7) clinical information (wards or diseases). Based on the survey results, we determined basic and extended criteria for MSR. With these criteria, we consulted nine hematology experts to get a consensus. RESULTS: All 111 laboratories had their own MSR criteria. Among 111 laboratories, 98 (88.3%) used more than three criteria for MSR including CBC results and 5-part WBC differential count results and 95 (85.6%) had criteria of flags triggering MSR. For MSR criteria with numeric values, the 10th, 50th, and 90th percentiles of upper and lower threshold values were obtained. The basic guideline for MSR was made. CONCLUSIONS: We proposed a basic guideline for MSR. This guideline would be helpful to hematology laboratories for their daily operation and providing more rapid and accurate CBC and WBC differential results.


Asunto(s)
Humanos , Automatización , Recuento de Células Sanguíneas/instrumentación , Laboratorios de Hospital , Recuento de Leucocitos/instrumentación , Control de Calidad , Encuestas y Cuestionarios