Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Añadir filtros








Intervalo de año
1.
Braz. j. pharm. sci ; 50(2): 381-389, Apr-Jun/2014. tab, graf
Artículo en Inglés | LILACS | ID: lil-722182

RESUMEN

In recent decades, there has been a significant increase in the incidence of fungal diseases. Certain fungal diseases cause cutaneous lesions and in the usual treatment, generally administred orally, the drug reaches the site of action with difficulty and its concentration is too low. An approach much explored in recent years is the development of nanotechnology-based drug delivery systems, and microemulsions (ME) and liquid crystals (LC) are promising. ME and LC were developed with oleic acid or copaiba oil as the oil phase, propoxyl (5OP) ethoxyl (20 OE) cetyl alcohol as surfactant and water. An analytical method to assess the incorporation of fluconazole (FLU) in the systems under study was validated according to guidelines of the International Conference on Harmonization (ICH) guidelines and the Brazilian Food, Drug and Sanitation Agency (ANVISA). The method was conducted on a C18-RP column (250 × 4.6 mm i.d.), maintained at room temperature. The mobile phase consisted of acetonitrile and water (50:50, v/v), run at a flow rate of 1.0mL/min and using ultraviolet detection at 210nm. The chromatographic separation was obtained with a retention time of 6.3min, and was linear in the range of 20-400 µg/mL (r2=0.9999). The specificity showed no interference of the excipients. The accuracy was 100.76%. The limits of detection and quantitation were 0.057 and 0.172 µg.mL-1, respectively. Moreover, method validation demonstrated satisfactory results for precision and robustness. The proposed method was applied for the analysis of the incorporation of FLU in ME and LC, contributing to improve the quality control and to assure the therapeutic efficacy.


Nas últimas décadas, houve aumento significativo na incidência de doenças fúngicas. Certas doenças fúngicas provocam lesões cutâneas, sendo que no tratamento usual, geralmente administrado por via oral, o medicamento chega ao local de ação com dificuldade, em concentração muito baixa. Uma abordagem muito explorada nos últimos anos é o desenvolvimento de sistemas de administração de fármacos baseados em nanotecnologia, como as microemulsões (ME) e cristais líquidos (LC). ME e LC foram desenvolvidos com o ácido oleico ou óleo de copaíba como fase oleosa, álcool cetílico propoxilado (5 OP) e etoxilado (20 OE) como tensoativo e água. Método analítico para avaliar a incorporação de fluconazol (FLU) nos sistemas em estudo foi validado de acordo com as diretrizes da Conferência Internacional de Harmonização (ICH) e Agência Nacional de Vigilância Sanitária (ANVISA). O método foi desenvolvido empregando coluna C18-RP (250 x 4,6 mm id), mantida à temperatura ambiente. A fase móvel consistiu de acetonitrila e água (50:50, v/v), executado a uma taxa de fluxo de 1,0 mL/min e com detecção ultravioleta a 210 nm. A separação cromatográfica foi obtida com o tempo de retenção de 6,3min, e mostrou-se linear no intervalo de 20-400 µg/mL (r2=0,9999). Pelo estudo de especificidade, observou-se não interferência dos excipientes. A precisão foi 100,76%. Os limites de detecção e de quantificação foram 0,057 e 0,172 µg.mL-1, respectivamente. Além disso, a validação do método demonstrou resultados satisfatórios para a precisão e robustez. O método proposto foi aplicado para a análise da incorporação do FLU em ME e cristais líquidos, contribuindo para aumentar o controle de qualidade e garantir a eficácia terapêutica.


Asunto(s)
Fluconazol/análisis , Cromatografía Liquida/clasificación , Cristales Líquidos/clasificación , Estudios de Validación como Asunto , Nanotecnología/clasificación
2.
Artículo en Portugués | LILACS | ID: lil-672210

RESUMEN

A exemplo do que ocorre com outros fármacos, a biodisponibilidade da anfotericina B (AmB) através da via ocular repreesenta um grande desafio para a pesquisa científica. Na verdade, a baixa biodisponibilidade apresentada por tal molécula é devido, principalmente, a presença das barreiras oculares que impedem a absorção deste fármaco para os tecidos internos. A toxicidade associada a este fármaco, assim como a sua baixa capacidade em permear a córnea íntegra também consiste em um problema associado ao seu uso clínico. Novos veículos seguros e eficazes para a liberação ocular da AmB são, portanto, necessários. As microemulsões (MEs) aparecem como um interessante sistema devido à sua transparência, estabilidade termodinâmica e favorável viscosidade. O conhecimento do processo de formação das MEs contendo AmB, assim como a compreensão de toda a sua caracterização físico-química correspondem a aspectos importantes para se determinar as condições favoráveis para que estes sistemas venham a ser empregados como colírios. Esta revisão tem como objetivo, portanto, abordar este tema enfatizando os principais aspectos relacionados com a utilização de MEs como sistemas de liberação para a AmB através da via tópica oftálmica.


As occurs with a number of drugs, the bioavailability of amphotericin B (AmB) used to treat fungal infections by the ocular route remains a great challenge to research scientists. In fact, the poor bioavailability of AmB is due mainly to the corneal barrier, which leads to a precorneal loss and consequent decrease in the absorption of this drug into the intraocular tissues. The toxicity associated with this molecule, together with its poor ability to penetrate the intact corneal epithelium, also represents a major drawback to its clinical use. New effective and safe drug vehicles for ocular delivery of AmB are therefore urgently needed. Microemulsions (MEs) seem to be an interesting system, owing to their transparent appearance, thermodynamic stability and favorable viscosity. Knowledge of the process of formation of AmB-containing MEs, as well as a good understanding of the physical chemistry of such systems, would provide reliable information on the best conditions for the use of these systems as eye drops. The goal of this research was thus to make an approach to this subject by reviewing the main studies on the use of MEs as delivery systems for AmB in topical eye treatment.


Asunto(s)
Antifúngicos , Anfotericina B/uso terapéutico , Ojo , Soluciones Oftálmicas
3.
Braz. j. pharm. sci ; 45(1): 87-92, jan.-mar. 2009. ilus, tab
Artículo en Inglés | LILACS | ID: lil-525774

RESUMEN

A simple, rapid, accurate and sensitive method was developed for quantitative analysis of dexamethasone acetate in microemulsions using high performance liquid chromatography (HPLC) with UV detection. The chromatography parameters were stainless steel Lichrospher 100 RP-18 column (250 mm x 4 mm i.d., 5 μm particle size), at 30 ± 2 ºC. The isocratic mobile phase was methanol:water (65:35; v/v) at a flow rate of at 1.0 mL.min-1. The determinations were performed using UV-Vis detector set at 239 nm. Samples were prepared with methanol and the volume injected was 20 μL. The analytical curve was linear (r² 0.9995) over a wide concentration range (2.0-30.0 μg.mL-1). The presence of components of the microemulsion did not interfere in the results of the analysis. The method showed adequate precision, with a relative standard deviation (RSD) smaller than 3 percent. The accuracy was analyzed by adding a standard drug and good recovery values were obtained for all drug concentrations used. The HPLC method developed in this study showed specificity and selectivity with linearity in the working range and good precision and accuracy, making it very suitable for quantification of dexamethasone in microemulsions. The analytical procedure is reliable and offers advantages in terms of speed and low cost of reagents.


Um método simples, rápido, preciso e sensível foi desenvolvido para a análise quantitativa de acetato de dexametasona em microemulsões usando cromatografia líquida de alta eficiência (CLAE). Os parâmetros cromatográficos foram: coluna cromatográfica Lichrospher 100 RP-18, (250 mm x 4 mm i.d., 5 μm partícula tamanho), com temperatura de coluna de 30 ± 2 ºC. A fase móvel foi composta de metanol: água (65:35; v/v) com fluxo isocrático de 1 mL.min-1 e volume de injeção de 20 μL. As determinações foram realizadas utilizando detector UV-Vis no comprimento de onda de 239 nm. A curva analítica mostrou-se linear (r² 0,999) em uma ampla faixa de concentração (2,0-30,0 μg.mL-1). A presença de componentes da microemulsão não interferiu nos resultados da análise. O método mostrou precisão adequada, com desvio padrão relativo menor que 3 por cento. A exatidão foi analisada pela adição de padrões do fármaco e valores de recuperação dentro dos limites recomendáveis foram obtidos para todas as concentrações estudadas. O método por CLAE mostrou especificidade e seletividade com linearidade dentro da faixa de concentração utilizada e precisão e exatidão que tornam o método adequado para a análise de dexametasona em microemulsões. O procedimento analítico é fidedigno e oferece vantagens em termos de velocidade e custo de reativos.


Asunto(s)
Cromatografía Líquida de Alta Presión/métodos , Dexametasona/análisis , Estudios de Evaluación como Asunto/métodos , Tensoactivos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA