Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Añadir filtros








Intervalo de año
1.
Arq. bras. oftalmol ; 84(6): 582-586, Nov.-Dec. 2021. tab, graf
Artículo en Inglés | LILACS-Express | LILACS | ID: biblio-1350069

RESUMEN

ABSTRACT Purpose: This quality and reliability study aimed to identify the mass variability of multidose eyedrops and to verify the existence of a reference pattern for the drop volume of eyedrops using standard lubricant eyedrops available on the Brazilian market. Methods: Five brands of lubricant eyedrops were evaluated. An ideal standard 20 µL drop of eyedrops from each manufacturer was captured using an adjustable micropipette. The eyedrop bottles were randomly selected, and five measurements of the samples' masses were collected using calibrated precision scales. Results: The mass of the 20 µL samples varied significantly (p<0.001) among the different manufacturers. However, among eyedrops of the same brand, mass variation was not statistically different. The global mean mass of all weighed drops was 18.24 mg, and non-uniformity was identified across all eyedrop brands. Conclusion: Significant variations in the drop masses of common lubricant eyedrops were identified using standard laboratory equipment. Heterogeneity in the drop volume of standard eyedrop medications suggest that potential dosage discrepancies exist, possibly altering treatment efficacy. A pre-established reference measure may lead to the production of more appropriately sized eyedrops for use in human eyes.


RESUMO Objetivo: Este estudo de qualidade e confiabilidade teve como objetivo identificar a variabilidade da massa do volume da gota de colírios multidose e verificar a existência de um padrão de referência para o volume da gota dos colírios usando lágrimas artificiais do mercado brasileiro. Métodos: Cinco marcas de colírios lubrificantes foram avaliadas quanto ao volume da gota. Uma gota padrão ideal de 20 µL de cada fabricante foi coletada usando uma micropipeta ajustável. Os frascos dos colírios foram selecionados aleatoriamente e cinco medidas das massas das amostras foram coletadas usando escalas de precisão calibradas. Resultados: A massa das amostras de 20 µL variou significativamente (p<0,001) entre os diferentes fabricantes. No entanto, entre os colírios da mesma marca, a variação da massa não foi estatisticamente diferente. A massa média global de todas as gotas pesadas foi de 18,24 mg e foi observada uma não-uniformidade entre todas as marcas de colírios. Conclusão: Identificou-se uma variação significativa nas massas do volume das gotas dos colírios lubrificantes, usando equipamento padrão de laboratório. A heterogeneidade no volume da gota dos colírios testados sugere a existência de discrepâncias potenciais em suas posologias, possivelmente alterando a eficácia do tratamento. Uma medida de referência pré-estabelecida pode levar à produção de colírios com gotas de tamanho mais apropriado para uso em olhos humanos.

2.
Rev. baiana saúde pública ; 44(4): 305-320, 20201212.
Artículo en Portugués | LILACS | ID: biblio-1379592

RESUMEN

O presente artigo tem como objetivo sistematizar o que tem sido publicado sobre desperdício de vacinas multidoses e monodoses. Trata-se de uma revisão da literatura construída a partir da questão norteadora: O que a literatura tem publicado sobre o desperdício de vacinas? Os unitermos definidos foram: "vaccine", "waste", "vial wastage" e "multidose". Para a seleção dos artigos foram consultadas as bases de dados "PubMed", "Scielo", "Revista Vaccine", "Periódicos Capes", "Teses e Dissertações Capes". Optou-se em continuar a busca por mais estudos utilizando a técnica "schneeball". A amostra final foi constituída de 26 artigos e duas dissertações, sendo o texto mais antigo de 2002 e os mais recentes de 2017. A maioria teve sua publicação no idioma inglês e em periódicos internacionais. Concluímos que independentemente das causas de desperdício de vacinas, evidencia-se a importância do monitoramento desses desperdícios e de serem criadas estratégias para sua redução.


This literature review summarizes the recent research published on multi-dose and single-dose vaccine waste. Based on the research question "What has been published on vaccine waste?" papers were selected from the PubMed, Scielo, Vaccine Magazine, Periods Capes, and Thesis and Dissertation Capes databases using the following descriptors: "vaccine," "waste," "vial wastage," "multidose." A manual search was performed using the "schneeball" technique. The final sample comprised 26 papers and 2 dissertations, the oldest text being from 2002 and the most recent from 2017. Most articles were published in English and in international journals. In conclusion, regardless its causes, vaccine wastage must be monitored and strategies developed for its reduction.


El presente artículo tiene como objetivo sistematizar lo que se ha publicado sobre el desperdicio de vacunas multidosis y monodosis. Se trata de una revisión de la literatura construida a partir de la cuestión orientadora: ¿Qué ha publicado la literatura sobre el desperdicio de vacunas? Los términos definidos fueron: "vaccine", "waste", "vial wastage" y "multidose". Para la selección de los artículos fueron consultadas las bases de datos "PubMed", "SciELO", "Revista Vaccine", "Periódicos Capes" y "Teses e Dissertações Capes". Se optó por continuar la búsqueda de más estudios utilizando la técnica "schneeball". La muestra final constó de 26 artículos y dos disertaciones, en que el más antiguo fue de 2002 y los más recientes de 2017. La mayoría tuvo su publicación en el idioma inglés y en revistas internacionales. Se concluyó que, independiente de las causas de desperdicio de vacunas, se evidencia la importancia del monitoreo de esos desperdicios y de que se creen estrategias para su reducción.


Asunto(s)
Vacunas , Inmunización , Estrategias de Salud , Cobertura de Vacunación , Fiscalización Sanitaria
3.
Braz. j. pharm. sci ; 50(1): 63-72, Jan-Mar/2014.
Artículo en Inglés | LILACS | ID: lil-709534

RESUMEN

Age-related macular degeneration (AMD) is an ocular inflammatory diseases treated mainly by means of a bevacizumab (Avastin®) or ranibizumab (Lucentis®) intravitreal injection. Among these drugs, only ranibizumab has a specific therapeutic indication for AMD. Considering that, the off-label use on ophthalmic therapy seems to become a rule when it should be an exception. Furthermore, bevacizumab presentation consists of multi-dose vials although it does not contain preservatives in its formula. The current literature review aimed at assessing the risks for the patient related to the use of off-label indication and multi-dose vials on AMD treatment. Considering this, the proposal related to the Brazilian Public Consultation no.10, dated September 12, 2012, which proposes the Clinical Protocol and Therapeutic Guidelines for AMD treatment, was evaluated. This systematic review allowed to conclude that the bevacizumab off-label indication results in increased risks for the patient when compared to the product with specific therapeutic indication for AMD treatment (ranibizumab), especially referring to the significant raise in the adverse events. The risks for the patient related to the multi-dose vial use, referring to the microbiological stability and dose precision, were also made clear.


A degeneração macular relacionada à idade (DMRI) é uma doença ocular inflamatória tratada principalmente por injeção intravítrea de bevacizumabe (Avastin®) ou de ranibizumabe (Lucentis®). Entre os medicamentos citados, apenas o ranibizumabe tem indicação terapêutica específica para uso oftálmico. Considerando essa realidade, o uso off-label na terapia oftálmica parece constituir regra quando deveria ser exceção. Ademais, a apresentação do bevacizumabe consiste em frascos de múltipla-dose, embora esse medicamento não contenha conservante em sua fórmula. A presente revisão da literatura avaliou os riscos ao paciente relativos ao uso indicado off-label e de frascos de múltipla-dose no tratamento de DMRI. Nesse sentido, avaliou-se a proposta relativa à Consulta Pública Brasileira nº 10, de 12 de setembro de 2012, que propõe o Protocolo Clínico e Diretrizes Terapêuticas para o tratamento de DMRI. O levantamento sistemático de trabalhos científicos e de informações relevantes de banco de dados eletrônicos permitiu concluir que a indicação off-label do bevacizumabe acarreta riscos maiores ao paciente, quando comparado ao produto com indicação terapêutica específica para o tratamento de DMRI (ranibizumabe), especialmente quanto ao aumento significativo de eventos adversos. Evidenciaram-se, também, os riscos ao paciente relativos ao uso de frascos de múltipla-dose, quanto à estabilidade microbiológica e à precisão da dose.


Asunto(s)
Humanos , Uso Fuera de lo Indicado/normas , Degeneración Macular/rehabilitación , Formas de Dosificación , Bevacizumab/farmacología , Ranibizumab/farmacología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA