Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Añadir filtros








Intervalo de año
1.
China Occupational Medicine ; (6): 443-2022.
Artículo en Chino | WPRIM | ID: wpr-965129

RESUMEN

@#Abstract: Nitrobenzene compounds (NBCs) are widely used in the world. It has 40 isomers such as nitrobenzene, dinitrobenzene and nitrotoluene, that are highly toxic and difficult to degrade and can cause harm to human health in different degrees. At pres⁃ ent, there is no unified standard method and occupational exposure limit for the detection of NBCs in the air. In terms of sampling medium, solid adsorption tube is mostly used for trapping vapor state NBCs, and filter membrane and solid adsorption tube are mostly used in series for sampling coexist NBCs in vapor state and aerosol state. In the detection methods, gas chromatography and liquid chromatography are common, and ultraviolet spectrophotometry, Raman spectroscopy, ion migration spectrometry and some other rapid response methods and technologies are also used in the detection of NBCs. In the detection of NBCs by gas chro⁃ matography, capillary column separation is commonly used, and the main detectors are flame ionization detector, electron capture detector and mass spectrometry detector. It is of practical significance to establish a method with high sensitivity, strong practica⁃ bility, convenient operation, and can simultaneously collect and detect a variety of NBCs in different states.

2.
China Occupational Medicine ; (6): 697-2022.
Artículo en Chino | WPRIM | ID: wpr-976106

RESUMEN

@#Objective - - To prepare the GDH 5 air sampling tube for simultaneous collection of eight kinds of chloro nitrobenzene ( ) , compounds CNBs in the air of workplace and establish a matching determination method using gas chromatography. Methods - - , Eight kinds of CNBs in vapor and aerosol state were collected by self developed GDH 5 air sampling tube desorbed , , , by toluene separated by polysiloxane gas chromatography column detected by microcell electron capture detector and Results - ( - quantified by external standard method. It was determined that the air sampling tube was assembled by XAD 2 ion ) - , exchange resin and glass fiber filter membrane. The linear range of CNBs was 0.80 240.00 mg/L and the linear correlation - - coefficients were greater than 0.999 9. The detection limit was 7.87 13.03 μg/L. The minimum detectable concentration was 0.60 3, - 3( ) 1.33 μg/m and the minimum quantitative concentration was 2.00 4.22 μg/m sample 45.00 L . The average desorption - - (RSD) - , - RSD efficiency was 101.2% 110.0%. The within run relative standard deviation was 0.8% 4.1% and the between run - Conclusion - was 0.3% 5.8%. The samples could be stored for more than 30 days at room temperature. GDH 5 air sampling tube and its associated determination method can be used for the collection and determination of eight kinds of CNBs in workplace air.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA