Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Añadir filtros








Intervalo de año
1.
China Pharmacy ; (12): 3862-3864, 2017.
Artículo en Chino | WPRIM | ID: wpr-662936

RESUMEN

OBJECTIVE:To establish a method for simultaneous determination of 6 components in Niuhuang ninggong tablets.METHODS:HPLC method was adopted.The determination was performed on TC-C18 column with mobile phase consisted of methanol-0.05% phosphate acid (gradient elution) at the flow rate of 1.0 mL/min.The detection wavelength was set at 280 nm,and the column temperature was 25 ℃.The sample size was 10 μL.RESULTS:The linear ranges of glycyrrhizin,berberine hydrochloride,baicalin,baicalin,emodin and chrysophanol were 3.2-320 μg/mL(r=0.999 9),8.8-880 μg/mL(r=0.999 8),5.6-560 μg/mL (r=0.999 5),2.0-200 μg/mL(r=0.999 9),4.4-440 μg/mL (r=0.999 9),2.0-200 μg/mL(r=0.999 7),respectively.RSDs of precision,stability and reproducibility tests were all lower than 6.0%.The recoveries were 96.34%-97.25% (RSD=0.33%,n=6),96.12%-98.06% (RSD=0.82%,n=6),96.36%-99.09% (RSD=1.02%,n=6),95.84%-97.32% (RSD=0.65%,n=6),95.83%-97.92%(RSD=0.88%,n=6),98.60%-99.65%(RSD=0.42%,n=6),respectively.CONCLUSIONS:The method is simple,accurate,stable and reproducible,and can be used for content determination of 6 components in Niuhuang ninggong tablets.

2.
China Pharmacy ; (12): 3862-3864, 2017.
Artículo en Chino | WPRIM | ID: wpr-661055

RESUMEN

OBJECTIVE:To establish a method for simultaneous determination of 6 components in Niuhuang ninggong tablets.METHODS:HPLC method was adopted.The determination was performed on TC-C18 column with mobile phase consisted of methanol-0.05% phosphate acid (gradient elution) at the flow rate of 1.0 mL/min.The detection wavelength was set at 280 nm,and the column temperature was 25 ℃.The sample size was 10 μL.RESULTS:The linear ranges of glycyrrhizin,berberine hydrochloride,baicalin,baicalin,emodin and chrysophanol were 3.2-320 μg/mL(r=0.999 9),8.8-880 μg/mL(r=0.999 8),5.6-560 μg/mL (r=0.999 5),2.0-200 μg/mL(r=0.999 9),4.4-440 μg/mL (r=0.999 9),2.0-200 μg/mL(r=0.999 7),respectively.RSDs of precision,stability and reproducibility tests were all lower than 6.0%.The recoveries were 96.34%-97.25% (RSD=0.33%,n=6),96.12%-98.06% (RSD=0.82%,n=6),96.36%-99.09% (RSD=1.02%,n=6),95.84%-97.32% (RSD=0.65%,n=6),95.83%-97.92%(RSD=0.88%,n=6),98.60%-99.65%(RSD=0.42%,n=6),respectively.CONCLUSIONS:The method is simple,accurate,stable and reproducible,and can be used for content determination of 6 components in Niuhuang ninggong tablets.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA