Braz. j. microbiol ; 40(3): 541-546, Sept. 2009.
Artículo en Inglés | LILACS | ID: lil-522474

RESUMEN

It is estimated that electric drills (ED) have been used in orthopaedic surgeries for bone drilling for more than 50 years in Brazilian hospitals. It is an electric, thermosensitive equipment, not indicated for surgical use, which has not been previously evaluated regarding the sterilization efficacy, being suspect of infection risk. This study evaluated the efficacy of sterilization by ethylene oxide (EtO) of new drills that were intentionally contaminated with Bacillus atrophaeus spores. An experimental, laboratory, randomized applied research was developed, where 16 electric drills were analyzed, in addition to positive and negative controls. All the previously cleaned and sterilized equipment were submitted to contamination by spores. The experimental group was submitted to cleaning and sterilization by EtO and test of sterility by filtration through a 0.45 µm membrane. The membranes were cultivated and Gram and Wirtz-Conklin staining were carried out in positive results for spore visualization. An efficacy of 99.99999881 percent of the process of sterilization by EtO was confirmed, with a probability of survival of 1.19 x 10-8. Under the development conditions of the experiment, the efficacy of the sterilization of ED by EtO was confirmed.


Estima-se que há mais de 50 anos, as furadeiras elétricas têm sido empregadas em cirurgias ortopédicas nos hospitais brasileiros para a perfuração óssea. Trata-se de equipamento elétrico, termossensível, não indicado para uso cirúrgico, não avaliado anteriormente quanto à eficácia da esterilização, suspeitando-se de risco para infecções. Esse estudo avaliou a eficácia da esterilização por óxido de etileno (ETO) de furadeiras novas intencionalmente contaminadas com esporos de Bacillus atrophaeus. Foi desenvolvida pesquisa experimental, laboratorial, randomizada e aplicada onde foram analisadas 16 furadeiras elétricas, além de controle positivo e negativo. Todos os equipamentos previamente limpos e esterilizados foram submetidos à contaminação com esporos. O grupo experimental foi submetido à limpeza e esterilização por ETO e teste de esterilidade por filtração por membrana de 0,45 µm. As membranas foram cultivadas e para resultados positivos foram realizadas coloração de Gram e Wirtz-Conklin para visualização dos esporos. Foi comprovada a eficiência de 99,99999881 por cento do processo de esterilização por ETO, com a probabilidade de sobrevivência de 1,19 x 10-8. Nas condições do desenvolvimento do experimento, a eficácia da esterilização das FE por ETO foi comprovada.

2.
Acta ortop. bras ; 17(3): 155-158, 2009. ilus, tab
Artículo en Inglés, Portugués | LILACS | ID: lil-520012

RESUMEN

OBJETIVO: Avaliar o risco de contaminação operatória pela ventilação do motor de furadeiras elétricas (FE) durante a perfuração óssea em cirurgias ortopédicas. MATERIAIS E MÉTODOS: estudo experimental, laboratorial, randomizado analisou FE da prática clínica e FE novas (limpas e esterilizadas) submetidas à contaminação com esporos de Bacillus atrophaeus na concentração 84 x 10(6) UFC. O ar gerado pelo acionamento do motor da FE foi coletado e cultivado. RESULTADOS: Foram identificadas apenas duas culturas positivas para as FE da prática clínica, assim como uma cultura positiva para o Bacillus atrophaeus com crescimento de 1UFC (1,19 x 10(8)). CONCLUSÃO: nas condições do estudo, pode-se afirmar que o ar gerado pela ventilação do motor da FE não consiste em fonte de contaminação para o sítio cirúrgico.


OBJECTIVE: To evaluate the potential risk of surgical contamination by the venting port of ordinary electric drills (ED) employed in orthopaedic surgeries. MATERIALS AND METHODS: an experimental laboratory, randomized study was developed to analyze EDs in surgical practice and new cleaned and sterilized equipment, which were contaminated with Bacillus atrophaeus spores at a concentration of 84 X 10(6) UFC. The air generated by the engine of each drill was collected and cultivated on sterile agar plates. RESULTS: Positive culture was identified in two ED in surgical practice, as well as a positive culture to Bacillus atrophaeus with 1 CFU growth (1,19 X 10-8). CONCLUSION: In the conditions of the experiment, the airgenerated by the venting port of the ED's engine does not consist of a source of contamination for the surgical site.


Asunto(s)
Humanos , Contaminación de Equipos , Infección de la Herida Quirúrgica , Equipo Ortopédico , Infecciones Relacionadas con Prótesis , Contaminación del Aire
3.
Acta ortop. bras ; 15(3): 163-165, 2007.
Artículo en Portugués | LILACS | ID: lil-460888

RESUMEN

As furadeiras elétricas domésticas tem sido empregadas em cirurgias ortopédicas nos Hospitais Brasileiros, para a perfuração óssea. Entretanto, trata-se de um equipamento elétrico, termossensível, não específico para uso cirúrgico, não avaliado quanto à eficácia da esterilização e não investigada a ocorrência de infecções cirúrgicas relacionadas ao seu uso. O objetivo dessa revisão foi descrever o estado da arte do uso das furadeiras domésticas em cirurgias ortopédicas, tendo em vista as dificuldades de limpeza e esterilização do equipamento. As bases de dados LILACS e MEDLINE foram consultadas usando vocabulários controlados, livres e a combinação deles, sem restrição de tempo. Foram localizados dois artigos que abordavam o uso de furadeiras elétricas domésticas em cirurgias ortopédicas. No primeiro, o autor sugere o descarte do equipamento quando percebida a contaminação interna por sangue, considerando as dificuldades da limpeza e esterilização. O segundo artigo descreve a adaptação de uma furadeira para o uso em cirurgias, cujo método de esterilização é pastilha de formalina em condições ambientais. Estudos são necessários para avaliar a prática atual e recomendar condições seguras de uso ou o seu abandono.


Domestic ordinary drilling machines have been used in orthopedic surgeries in Brazilian hospitals, for bone drilling. However, it is an electric thermo-sensitive appliance, non-specific for surgical use, not assessed in terms of sterilization efficiency, as well as on potential surgical infections associated to its use. The objective of this review was to describe the state-of-the-art use of domestic drills in orthopaedic surgeries, considering the difficulties of cleaning and sterilization. The LILACS and MEDLINE databases were consulted using MeSH and free medical terms, without time restraints. Two specific articles were found about the use of domestic electric drills in orthopaedic surgeries. In the first article, the author suggests the disposal of the equipment in cases of any noticeable blood contamination that could result in difficulties to clean it. The second article describes how to adapt a domestic drilling machine for orthopaedic surgery, but the sterilization process is performed by using formalin tablets at room conditions. Further studies are required for evaluating the current practice and to recommend safe conditions for its use or towards giving it up.