Arq. bras. med. vet. zootec. (Online) ; 72(4): 1231-1240, July-Aug. 2020. tab
Artículo en Portugués | LILACS, VETINDEX | ID: biblio-1131500

RESUMEN

Objetivou-se avaliar diferentes modalidades ventilatórias em cães de diferentes idades submetidos à fração inspirada de oxigênio (FiO2) de 40% e 100%. Foram utilizados 36 cães de três grupos etários (GJ: 0-5; GA: 5-10 e GG: 10-15 anos), sem padronização de peso, sexo, raça e procedimento cirúrgico. Foram pré-medicados com acepromazina e morfina (0,02 e 0,5mg/kg), induzidos à anestesia geral com propofol dose-efeito, manutenção do plano anestésico com isoflurano em 1,3 V% e fornecimento de oxigênio conforme a FiO2 estabelecida para o grupo. Os animais foram submetidos a quatro diferentes modalidades ventilatórias: ventilação espontânea (VE), ventilação ciclada a volume (VCV), ventilação ciclada a pressão (VCP) e ventilação ciclada a pressão com PEEP (VCPP), e permaneceram 30 minutos em cada modalidade. Os parâmetros cardiovasculares mantiveram-se estáveis para todas as FiO2, modalidades ventilatórias e idades. Com relação aos parâmetros ventilatórios, na FiO2 100%, foram observados PaCO2 de 45mmHge e 29% de shunt, enquanto a FiO2 40% apresentou PaCO2 de 43 mmHg e 13% de shunt. Em relação às diferentes idades, os animais adultos e geriátricos apresentaram maiores valores de shunt (26% e 22%) e PaCO2 (44mm/Hg e 46mm/Hg). Conclui-se que a fração inspirada de 40% e a modalidade ventilatória ciclada a volume mostraram-se mais eficientes.(AU)


The objective was to evaluate different ventilatory modalities in dogs of different ages submitted to the inspired fraction of oxygen (FiO2) of 40% and 100%. Thirty-six dogs from three age groups (GJ 0-5, GA 5-10 and GG 10-15 years) were used, without standardization of weight, gender, race and surgical procedure. They were premedicated with acepromazine and morphine (0.02 and 0.5mg/kg), induced to general anesthesia with propofol dose/effect, maintenance of the anesthetic plane with isoflurane in 1.3V% and oxygen supply according to FiO2 established for the group. The animals were submitted to 4 different ventilation modalities, spontaneous ventilation (VS), volume-cycled ventilation (VCV), pressure-cycled ventilation (VCP) and pressure-cycled ventilation with PEEP (VCPP) and remained 30 minutes in each modality. The cardiovascular parameters remained stable for all FiO2, ventilatory modalities and ages. Regarding ventilatory parameters, in FiO2 and PaCO2 of 45mmHg and 29% of shunt, in FiO2 100%, PaCO2 of 43mmHg and 13% of shunt were observed. Regarding the different ages, adult and geriatric animals presented higher values of Shunt (26 and 22%) and PaCO2 (44 and 46mmHg). It was concluded that the inspired fraction of 40% and the volume-cycled ventilatory modality were more efficient.(AU)


Asunto(s)
Animales , Perros , Respiración Artificial/veterinaria , Análisis de los Gases de la Sangre/veterinaria , Capacidad Inspiratoria , Factores de Edad
2.
Ciênc. rural ; 41(11): 1960-1966, nov. 2011. tab
Artículo en Portugués | LILACS | ID: lil-608042

RESUMEN

Avaliaram-se os efeitos do fornecimento de diferentes frações inspiradas de oxigênio (FiO²) em coelhos hipovolêmicos, anestesiados com infusão contínua de propofol e mantidos em ventilação controlada sobre os parâmetros respiratórios, hemogasométricos e hemodinâmicos. Foram utilizados 50 coelhos (Nova Zelândia), pesando 3,5±0,3kg, distribuídos em 5 grupos: G100 (FiO²=1), G80 (FiO²=0,8), G60 (FiO²=0,6), G40 (FiO²=0,4) e G21 (FiO²=0,21), os quais receberam xilazina (1mg kg-1) e cetamina (15mg kg-1) pela via intramuscular. Transcorridos 20 minutos, foi administrado propofol (8mg kg-1 bolus e 0,5mg kg-1 min-1) e rocurônio (0,6mg kg-1 bolus e 0,6mg kg-1 h-1). Iniciou-se então, a ventilação mecânica no modo pressão controlada. Após 30 minutos, os animais foram submetidos à hipovolemia aguda, retirando-se sangue arterial (12mL kg-1). Os parâmetros foram mensurados 30 minutos após a indução anestésica (M0) e a cada dez minutos depois da exsanguinação (M1- M7). As variáveis foram submetidas à análise de variância seguida pelo teste de Tukey (P<0,05). Os valores de PaO², SaO², P A O², AaDO² diminuíram quanto mais baixas foram as FiO². Após a indução da hipovolemia, as variáveis DC, PAM, PaO², SaO², Vt, AaDO² diminuíram significativamente. Nenhuma alteração foi notada nos parâmetros FC e PaCO². As FiO² de 0,8 e 1,0 mostraram-se as mais indicadas por manter melhor estabilidade ventilatória e adequada troca gasosa.


The effects of several inspired oxygen fractions (FiO²) on the blood gases, respiratory and hemodynamic parameters in mechanical ventilation hypovolemic rabbits anesthetized with continuous infusion of propofol were evaluated. A total of 50 rabbits (New Zealand), weighing 3.5±0.3kg, were divided into five groups: G100 (FiO²=1), G80 (FiO²=0.8), G60 (FiO²=0.6), G40 (FiO²=0.4) and G21 (FiO²=0.21), which received xylazine (1mg kg-1) and ketamine (15mg kg-1) intramuscularly. Exactly after 20 minutes, it was administered propofol (8mg kg-1 bolus and 0.5mg kg-1 min-1) and rocuronium (0.6mg kg-1 bolus and 0.6mg kg-1 h-1. Then, the mechanical ventilation by controlled pressure mode began. After 30 minutes, the animals underwent acute hypovolemia, withdrawing arterial blood (12mL kg-1). The parameters were measured 30 minutes after anesthetic induction (M0) and every ten minutes after exsanguination (M1-M7). The variables were subjected to analysis of variance followed by Tukey test (P<0.05). The values of PaO², SaO², PAO², AaDO² decreased as lower were the FiO². After the induction of hypovolemia, the variables CO, MAP, PaO², SaO², Vt, AaDO² decreased significantly. No change was noted in the parameters HR and PaCO². The FiO² of 0.8 and 1.0 proved to be the most suitable for maintaining stability, better ventilation and adequate gas exchange.

3.
Arq. bras. med. vet. zootec ; 61(2): 345-352, abr. 2009. tab
Artículo en Portugués | LILACS | ID: lil-518711

RESUMEN

Avaliaram-se os efeitos do fornecimento de diferentes frações inspiradas de oxigênio (FiO2) em cães anestesiados com infusão contínua de propofol e mantidos em ventilação espontânea sobre os parâmetros ecocardiográficos, obtidos em modo M. Oito cães adultos foram submetidos a cinco protocolos anestésicos diferenciando um do outro pela FiO2 fornecida ao paciente. Formaram-se cinco grupos denominados G100 (FiO2=1), G80 (FiO2=0,8), G60 (FiO2=0,6), G40 (FiO2=0,4) e G20 (FiO2=0,21). Os animais foram induzidos à anestesia com propofol na dose necessária para intubação e, ato contínuo, iniciou-se a infusão do fármaco. Os cães receberam oxigênio conforme a FiO2 determinada para cada grupo. As primeiras mensurações foram efetuadas antes da administração do fármaco (M0), aos 30 minutos (M30) após o início da infusão do anestésico e a cada 15 minutos (M45, M60, M75 e M90) durante 60 minutos. Para espessura do septo interventricular ao final da sístole (ESIVs) registrada em M60, a média de G100 foi maior do que as obtidas de G60 e G20. Em M30, o espessamento fracional da parede livre do ventrículo esquerdo (ELPVE) de G100 foi menor que de G80, e, em M75, G80 foi maior que G40. Em relação ao índice de volume ventricular esquerdo ao final da sístole (IVVEFs), em M45, G40 foi maior que G80. Conclui-se que as variáveis ecocardiográficas estudadas não são afetadas pelo emprego de diferentes FiO2.


The effects of several inspired oxygen fractions (FiO2) on the echocardiographic parameters by M-mode were evaluated in eight adult spontaneously breathing mongrel dogs anesthetized with continuous infusion of propofol. Each animal underwent five anesthesia procedures. In each procedure, the patient was allowed to breath a different FiO2, thereby resulting in five groups, namely: G100 (FiO2 = 1), G80 (FiO2 = 0.8), G60 (FiO2 =0.6), G40 (FiO2 = 0.4), and G20 (FiO2 = 0.21). To induce anesthesia, propofol was given until the animals allowed orotracheal intubation, followed by immediate continuous infusion of propofol. The initial measurement (M0) was performed before any drug administration, the second was recorded 30 minutes after the infusion of propofol (M30), and additional recordings were performed at 15-minute intervals (M45, M60, M75, and M90), during 60 minutes. At M60, for the end-systolic interventricular septum thickness (IVSs), the mean of G100 was greater than G60 and G20. Regarding left ventricular wall fractional thickness (LVWF) at M30, G100 was lower than G80; and at M75, G80 was greater than G40. In relation to left ventricular end-systolic volume index (ESVI), at M45, G40 was greater than G80. In conclusion, different FiO2 does not impair echocardiographic parameters.


Asunto(s)
Animales , Perros , Ecocardiografía , Consumo de Oxígeno , Propofol/administración & dosificación , Propofol/efectos adversos
4.
Ciênc. rural ; 38(3): 729-735, maio-jun. 2008. tab
Artículo en Portugués | LILACS | ID: lil-480185

RESUMEN

Avaliaram-se os efeitos do fornecimento de diferentes frações inspiradas de oxigênio (FiO2) sobre os parâmetros hemodinâmicos em cães submetidos à infusão contínua de propofol e mantidos em ventilação espontânea. Foram utilizados oito cães, os quais foram empregados em cinco grupos com diferentes FiO2, G100 (FiO2 = 1), G80 (FiO2 = 0,8), G60 (FiO2 = 0,6), G40 (FiO2 = 0,4) e G20 (FiO2 = 0,21), respeitando-se um intervalo de dez dias entre cada procedimento anestésico. Os animais foram induzidos e mantidos sob anestesia com propofol na dose de 0,7mg kg-1 min-1 e, após a intubação orotraqueal, iniciou-se o fornecimento de oxigênio conforme a FiO2 determinada para cada grupo. As primeiras mensurações, da freqüência cardíaca (FC), das pressões arteriais sistólica, diastólica e média (PAS, PAD e PAM), da resistência vascular periférica e pulmonar (RPT e RPV), do débito cardíaco (DC); da pressão venosa central (PVC), da pressão média da artéria pulmonar (PMAP), da pressão média capilar pulmonar (PMCP), da pressão parcial de oxigênio (PaO2) e do dióxido de carbono (PaCO2) no sangue arterial, foram efetuadas 30 minutos após o início da infusão do anestésico (M0), seguidas de intervalos de 15 minutos (M15, M30, M45 e M60). Os dados numéricos obtidos foram submetidos à Análise de Variância, seguida pelo teste Tukey (P<0,05). Os parâmetros hemodinâmicos não apresentaram diferenças significativas ao longo do tempo e entre os grupos. Os resultados obtidos permitiram concluir que as variáveis hemodinâmicas não são afetadas pelo emprego de diferentes FiO2.


The effects of several inspired oxygen fractions (FiO2) in hemodynamics parameters in spontaneously breathing dogs submitted to continuous infusion of propofol were evaluated. Eight adult mongrel dogs were studied and the animals underwent five anesthesias. In each procedure the patient was submitted to a different FiO2, thereby resulting in five groups, namely: G100 (FiO2 = 1), G80 (FiO2 = 0.8), G60 (FiO2 =0.6), G40 (FiO2 = 0.4), and G20 (FiO2 = 0.21). The dose of propofol was sufficient to abolish protector reflex and ensure endotracheal intubation, followed by immediate continuous infusion of that drug (0.7mg kg-1 min-1). The initial measurement (M0) of heart rate (HR); systolic (SAP), diastolic (DAP) and mean pressure (MAP), systemic (SVR) and pulmoary vascular resistance (PVR), cardiac output (CO); central venous pressures (CVP); mean pulmonary pressure (MPAP); pulmonary capillary wedge pressure (PCWP), arterial partial pressure of oxygen (PaO2) and carbon dioxide (PaCO2) were recorded thirty minutes after the beginning of propofol infusion. Additional recordings were performed at each 15-minute interval during 60 minutes (M15, M30, M45, and M60). Numeric data were submitted to Analysis of Variance followed by Tukey Test (P<0.05). Significant values of hemodynamic parameters were not recorded neither during the experiment period nor among the groups. In conclusion, different FiO2 does not impair hemodynamic parameters.


Asunto(s)
Animales , Masculino , Femenino , Perros , Anestesia/veterinaria , Nivel de Oxígeno , Propofol/administración & dosificación , Propofol/uso terapéutico
5.
Arq. bras. med. vet. zootec ; 60(2): 359-366, abr. 2008. tab
Artículo en Portugués | LILACS | ID: lil-484662

RESUMEN

Avaliaram-se os efeitos do fornecimento de diferentes frações inspiradas de oxigênio (FiO2) sobre o índice biespectral (BIS) em cães submetidos a infusão contínua de propofol e mantidos em ventilação espontânea. Oito cães foram submetidos a cinco anestesias, diferenciando-se uma da outra pela FiO2 fornecida. Formaram-se cinco grupos denominados G100 (FiO2 = 1); G80 (FiO2 = 0,8); G60 (FiO2 = 0,6); G40 (FiO2 = 0,4) e G20 (FiO2 = 0,21). Os animais foram induzidos à anestesia com propofol na dose necessária para intubação, e, ato contínuo, iniciaram-se a infusão do fármaco e o fornecimento de oxigênio, conforme a FiO2 determinada para cada grupo. As primeiras mensurações (M0) foram efetuadas 30 minutos após o início da infusão do anestésico e, depois, em intervalos de 15 minutos (M15, M30, M45 e M60). A pressão parcial de oxigênio no sangue arterial (PaO2) variou conforme a FiO2, ou seja, quanto maior a FiO2, maior foi a PaO2. Para a pressão parcial de dióxido de carbono no sangue arterial (PaCO2), foram registradas diferenças em M30, no qual G100 foi maior que G20. Não foram observadas diferenças significativas nas variáveis estudadas do BIS. Os intervalos de médias registrados para o BIS foram, para G100, de 68 a 62; G80, de 71 a 58; G60, de 72 a 62; G40, de 76 a 68; e G20, de 77 a 68. Conclui-se que as variáveis relacionadas ao BIS não são afetadas pelo emprego de diferentes FiO2, e sugere-se que o monitoramento pelo BIS foi capaz de detectar alterações no equilíbrio do fluxo sangüíneo cerebral, oriundas das alterações ocasionadas na dinâmica respiratória pelo emprego de diferentes frações inspiradas de oxigênio.


The effects of several inspired oxygen fractions (FiO2) on the bispectral index in spontaneously breathing dogs submitted to continuous infusion of propofol were evaluated. Eight adult mongrel dogs were used. Each animal was submitted to five anesthesias. In each procedure, the patient was allowed to breathe a different FiO2, thereby resulting in five groups, namely: G100 (FiO2 = 1), G80 (FiO2 = 0.8), G60 (FiO2 =0.6), G40 (FiO2 = 0.4), and G20 (FiO2 = 0.21). To induce anesthesia, propofol was given until the animals allowed orotracheal intubation, followed by immediate continuous infusion of drug. The initial measurement (M0) was recorded 30 minutes after the infusion of propofol onset. Additional recordings were performed at 15-minute intervals during 60 minutes (M15, M30, M45, and M60). No significant differences on BIS parameters were recorded. Regarding arterial partial pressure of carbon dioxide (PaCO2), the mean of G100 was greater than G20 at M30, whereas arterial partial pressure of oxygen (PaO2) varied according to the changes in oxygen. The mean intervals of BIS were: for G100, from 68 to 62; for G80, from 71 to 58; for G60, from 72 to 62; for G40 from 76 to 68; and for G20, from 77 to 68. In conclusion, different FiO2 does not impair BIS parameters. However, it is suggested that BIS was able to detect changes in the balance of cerebral blood flow, which was a result of changes in respiratory dynamic by the use of several inspired fractions.


Asunto(s)