Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Añadir filtros








Intervalo de año
1.
Artículo en Inglés | WPRIM | ID: wpr-631247

RESUMEN

"Introduction A chromatographer always looks forward to getting perfect shaped peaks for each and every analysis but in reality peaks get distorted due to numerous reasons. Distortions are frustrating but if proper corrective steps are taken peak shape distortions can be avoided. Peak purity can be established by taking the ratio of two wavelengths across the peaks of running samples or standard. May, if the peak is pure, then the ratio of wavelengths should be constant across the peak. Otherwise, the peak is impure, then the ratio between two wavelengths will change across the peak as the spectral differences caused by interfering peak change the signal ratio."

2.
Artículo en Coreano | WPRIM | ID: wpr-151375

RESUMEN

OBJECTIVES: This study investigated the effect of infection control barrier thickness on power density, wavelength, and light diffusion of light curing units. MATERIALS AND METHODS: Infection control barrier (Cleanwrap) in one-fold, two-fold, four-fold, and eight-fold, and a halogen light curing unit (Optilux 360) and a light emitting diode (LED) light curing unit (Elipar FreeLight 2) were used in this study. Power density of light curing units with infection control barriers covering the fiberoptic bundle was measured with a hand held dental radiometer (Cure Rite). Wavelength of light curing units fixed on a custom made optical breadboard was measured with a portable spectroradiometer (CS-1000). Light diffusion of light curing units was photographed with DSLR (Nikon D70s) as above. RESULTS: Power density decreased significantly as the layer thickness of the infection control barrier increased, except the one-fold and two-fold in halogen light curing unit. Especially, when the barrier was four-fold and more in the halogen light curing unit, the decrease of power density was more prominent. The wavelength of light curing units was not affected by the barriers and almost no change was detected in the peak wavelength. Light diffusion of LED light curing unit was not affected by barriers, however, halogen light curing unit showed decrease in light diffusion angle when the barrier was four-fold and statistically different decrease when the barrier was eight-fold (p < 0.05). CONCLUSIONS: It could be assumed that the infection control barriers should be used as two-fold rather than one-fold to prevent tearing of the barriers and subsequent cross contamination between the patients.


Asunto(s)
Humanos , Difusión , Técnica de Inmunoensayo de Enzimas Multiplicadas , Mano , Control de Infecciones , Luz
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA