Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
Korean Circulation Journal ; : 830-833, 2001.
Artículo en Coreano | WPRIM | ID: wpr-104752

RESUMEN

Since the Inoue balloon was first introduced for percutaneous mitral valvuloplasty (PMV) in 1984, this procedure has come into widespread use because of its effectiveness, simplicity, and reduced exposure to X-ray radiation. It's the procedure's complications include cardiac tamponade, atrial septal defect, thromboembolism, ventricular perforation, mitral regurgitation, and rarely balloon rupture. We report a case of Inoue balloon deformity during PMV in 62-year old woman with rheumatic mitral stenosis. Echocardiography revealed severe rheumatic mitral stenosis with a valvular area of 0.95 cm2 (by pressure half-time method), and an Echo score of 10 points. The PMV with Inoue balloon 28 mm was performed. We inflated the balloon to 28 mm in diameter first, and to 29 mm second. A bulging deformity with asymmetrical overinflation of one side of both proximal and distal balloon was recognized. A bulging deformity at the proximal part of Inoue balloon after second inflation. Balloon was not ruptured. Following completion of the procedure, the mitral valve area increased to 1.8 cm2. Moderate mitral regurgitation (grade II) was newly developed. This may be the first case of asymmetrical one side inflation and focal bulging deformity reported in Korea.


Asunto(s)
Femenino , Humanos , Persona de Mediana Edad , Taponamiento Cardíaco , Anomalías Congénitas , Ecocardiografía , Defectos del Tabique Interatrial , Inflación Económica , Corea (Geográfico) , Válvula Mitral , Insuficiencia de la Válvula Mitral , Estenosis de la Válvula Mitral , Rotura , Tromboembolia
2.
Korean Circulation Journal ; : 1841-1851, 1998.
Artículo en Coreano | WPRIM | ID: wpr-179390

RESUMEN

BACKGROUND: Percutaneous Mitral Valvuloplasty (PMV) is the first-line treatment modality in selected patients with symptomatic mitral stenosis and more recently available Inoue single-balloon catheter technique produces good results with low incidence of complications. The purpose of this study was to evaluate the immediate and over 6 months follow-up results after successful PMV with an Inoue balloon and to identify the predictive factors for the results. METHODS: From May 1995 to Feburary 1997, a PMV with an Inoue balloon was tech-nically successful in 114 (95%) of the 119 patients treated at the Sejong General Hostpital. In this study, a series of echocardiographic follow-up were performed in 54 patients with rheumatic mitral stenosis, at least 6 months after their successful PMV. In PMV, the inflation was conducted in steps, starting with a recommended maximum size of balloon by the Inoue criteria. After each inflation, the mitral valve opening and competence were evaluated by Transesophageal echocardiography (TEE) and continuing increase balloon size. RESULTS: Echocardiographic follow-up assessment was performed in 54 patients serially in a interval of 3 months or 6 months. Their mean age was 46+/-11 years (24 to 66 years) and the mean total echocardiographic score was 7.1+/-1.6. A optimal result was obtained in 95% of the cases (51/54). The post-PMV mitral valve area increased to 1.95+/-0.37 cm 2 and 1.79+/-0.28 cm 2 by 2-D and Doppler method, the average transmitral mean diastolic pressure gradient decreased to 5.16+/-2.8 mmHg and LA pressure was decreased to 11.28+/-8.2 mmHg. The newly developed and aggravated mitral regurgitation was observed in 17 patients (31.5%). The restenosis was noted in 2 cases (3.7%) after 1 year follow-up. The pre-procedural echocardiographic score for leaflet mobility, thickening and calcification was more higher in patients with restenosis. There was significant tendency of decrement in the mitral valve area in patients with a echocardiographic score=8 compared with those< or =8 over 6 months after the PMV. CONCLUSION: PMV with the Inoue balloon under TEE guide as a combined treatment modality of patient with symptomatic mitral stenosis is relatively safe and achieves good immediate and midterm follow-up results. The echocardiographic score is considered as useful predictor of midterm results and restenosis after PMV with Inoue balloon.


Asunto(s)
Humanos , Presión Sanguínea , Catéteres , Ecocardiografía , Ecocardiografía Transesofágica , Estudios de Seguimiento , Incidencia , Inflación Económica , Competencia Mental , Válvula Mitral , Insuficiencia de la Válvula Mitral , Estenosis de la Válvula Mitral
3.
Korean Circulation Journal ; : 829-841, 1991.
Artículo en Coreano | WPRIM | ID: wpr-135554

RESUMEN

Percuaneous mitral valvuloplasty(PMV) is an alternative to surgical mitral commissurotomy for patients with mitral stenosis. To assess the immediate and follow-up results of PMV and to identify factors in fluencing the outcome and coplications of PMV, we analyzed the clinical, echocardiographic and hemodynamic data of 108 patients who underwent PMV. 1) Good hemodynamic results were obtained in 86 patients(79.6%). The factors predicting immediate outcome of PMV were mitral valve mobility, total echoscore, and EBDA/BSA. 2) Predictors of the increase in mitral valve area by PMV were age, sex, rhythm, and NYHA functional class before PMV. The independant predictors were rhythm(p=0.008) and functional class(p=0.002). 3) The degree of mitral regurgitation increased in 26 patients(24%), did not changed in 79 patients(73%) and decreased in 3 patients(3%). The increase of MR could not predicted from any features of the clinical, echocardiographic or hemodynamic daa. The severity of MR decreased by one grade in 15% of patients and did not change in 66% of patients during follow-up. 4) Left-to-right shunt was detected in 19 patients(18%). The predictors were valve mobility, pulmonary artery pressure and pulmonary vascular resistance. 5) Follow-up catheterization(mean 14 months) identified restenosis in six of 16 patients. The predictors of restenosis were sex, total echosecore, and left atrial volume. 6) The hemodynamic data at follow-up were good compared with prePMV data(p<0.01), but follow-up miral valve area decreased than that of postPMV(p<0.05). Immediate decrease in pulmonary vascular resistance followed by progressive improvement during follow-up. 7) Immediate complications of PMV were peripheral arterial embolism in one patient(1%), pericardial effusion in two(2%), transient arrhythmia in four(4%), left-to-right shunt in nineteen(18%) and increase in the grade of MR in twenty-six(24%). This study suggests, that PMV produces excellent immediate and follow-up results and is a safe and effective procedure in the nonsurgical treatment of mitral stenosis.


Asunto(s)
Humanos , Arritmias Cardíacas , Ecocardiografía , Embolia , Estudios de Seguimiento , Hemodinámica , Válvula Mitral , Insuficiencia de la Válvula Mitral , Estenosis de la Válvula Mitral , Derrame Pericárdico , Arteria Pulmonar , Resistencia Vascular
4.
Korean Circulation Journal ; : 829-841, 1991.
Artículo en Coreano | WPRIM | ID: wpr-135551

RESUMEN

Percuaneous mitral valvuloplasty(PMV) is an alternative to surgical mitral commissurotomy for patients with mitral stenosis. To assess the immediate and follow-up results of PMV and to identify factors in fluencing the outcome and coplications of PMV, we analyzed the clinical, echocardiographic and hemodynamic data of 108 patients who underwent PMV. 1) Good hemodynamic results were obtained in 86 patients(79.6%). The factors predicting immediate outcome of PMV were mitral valve mobility, total echoscore, and EBDA/BSA. 2) Predictors of the increase in mitral valve area by PMV were age, sex, rhythm, and NYHA functional class before PMV. The independant predictors were rhythm(p=0.008) and functional class(p=0.002). 3) The degree of mitral regurgitation increased in 26 patients(24%), did not changed in 79 patients(73%) and decreased in 3 patients(3%). The increase of MR could not predicted from any features of the clinical, echocardiographic or hemodynamic daa. The severity of MR decreased by one grade in 15% of patients and did not change in 66% of patients during follow-up. 4) Left-to-right shunt was detected in 19 patients(18%). The predictors were valve mobility, pulmonary artery pressure and pulmonary vascular resistance. 5) Follow-up catheterization(mean 14 months) identified restenosis in six of 16 patients. The predictors of restenosis were sex, total echosecore, and left atrial volume. 6) The hemodynamic data at follow-up were good compared with prePMV data(p<0.01), but follow-up miral valve area decreased than that of postPMV(p<0.05). Immediate decrease in pulmonary vascular resistance followed by progressive improvement during follow-up. 7) Immediate complications of PMV were peripheral arterial embolism in one patient(1%), pericardial effusion in two(2%), transient arrhythmia in four(4%), left-to-right shunt in nineteen(18%) and increase in the grade of MR in twenty-six(24%). This study suggests, that PMV produces excellent immediate and follow-up results and is a safe and effective procedure in the nonsurgical treatment of mitral stenosis.


Asunto(s)
Humanos , Arritmias Cardíacas , Ecocardiografía , Embolia , Estudios de Seguimiento , Hemodinámica , Válvula Mitral , Insuficiencia de la Válvula Mitral , Estenosis de la Válvula Mitral , Derrame Pericárdico , Arteria Pulmonar , Resistencia Vascular
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA