Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
Rev. bras. ortop ; 54(3): 295-302, May-June 2019. tab, graf
Artículo en Inglés | LILACS | ID: biblio-1013713

RESUMEN

Abstract Objective Currently, there is a lack of evidence on the medium-term follow-up of cementless total hip arthroplasty (THA) using metal on highly cross-linked polyethylene (MoP), ceramic-on-ceramic (CoC), and metal-on-metal (MoM) bearings. Our aim was to calculate the 5- to 10-year wear rate and the incidence rate of osteolysis for 3 types of bearings. Methods A total of 77 patients underwent MoP, 105 underwent ceramic CoC, and 55 underwent MoM THAs. The average patient age at the time of surgery was 64.7, 55.9, and 59.9 years old in the MoP, CoC, and MoM bearings, respectively. Clinical and radiologic measurements at a mean follow-up of 7.6 years were analyzed. Results The mean postoperative Harris hip scores showed no difference among the groups. The mean annual liner wear rates were 0.0160, 0.0040 and 0.0054 mm/year in MoP, CoC bearings, and MoM bearings, with that of CoC bearings being significantly lower than the others. Osteolysis (14.5%) among MoM bearings was significantly more frequently observed compared with the others. Kaplan-Meier survival at 10 years with implant loosening, or revisionTHA as the endpoint, was 96.1% (95% confidence interval [CI]: 88.4-98.7) forMoP, 98.6% (95% CI: 90.3-98.6) for CoC bearing, and 98.2% (95% CI: 88.0-99.7) for MoM bearings (p = 0.360). Conclusion Excellent clinical and radiological outcomes were obtained for MoP and CoC bearings.


Resumo Objetivo Hoje, não há evidências sobre o acompanhamento em médio prazo da artroplastia total do quadril (ATQ) não cimentada com componentes de polietileno de alta ligação cruzada (highly cross-linked) sobre metal (MoP, na sigla em inglês), de cerâmica sobre cerâmica (CoC, na sigla em inglês), e de metal sobre metal (MoM, na sigla eminglês). Nosso objetivo foi calcular a taxa de desgaste entre 5 a 10 anos e a taxa de incidência de osteólise nos 3 tipos de componentes. Métodos Um total de 77 pacientes foram submetidos a ATQ com componentes de MoP; 105 foram submetidos ao mesmo procedimento com componentes de CoC, e 55 foram submetidos à ATQ com componentes de MoM. A média de idade dos pacientes no momento da cirurgia foi de 64,7, 55,9 e 59,9 anos nos grupos de componentes MoP, de CoC, e de MoM, respectivamente. Asmedidas clínicas e radiológicas emumperíodo médio de acompanhamento de 7,6 anos foram analisadas. Resultados As pontuações médias de Harris no período pós-operatório não mostraram diferença entre os grupos. As taxas médias anuais de desgaste do revestimento foram de 0,0160, 0,0040 e 0,0054 mm/ano em componentes de MoP, de CoC, e de MoP, respectivamente; a taxa de desgaste dos componentes de CoC foi significativamente menor do que as dos demais. A osteólise (14,5%) nos componentes de MoM foi significativamente mais frequente em comparação aos demais. A sobrevida de Kaplan- Meier aos 10 anos comafrouxamento do implante ou revisão da ATQ como desfecho foi de 96,1% (intervalo de confiança [IC] de 95%: 88,4-98,7) nos componentes de MoP, de 98,6% (IC95%: 90,3-98,6) nos componentes de CoC, e de 98,2% (IC95%: 88,0-99,7) nos componentes de MoM (p = 0,360). Conclusão Os resultados clínicos e radiológicos de componentes de MoP e de CoC foram excelentes.


Asunto(s)
Humanos , Masculino , Femenino , Polietilenos , Artroplastia , Diseño de Prótesis , Cerámica , Metales
2.
Rev. bras. oftalmol ; 71(4): 227-232, jul.-ago. 2012. ilus, tab
Artículo en Portugués | LILACS | ID: lil-650654

RESUMEN

OBJETIVO: Alterações oculares, em especial a perda de volume nas cavidades evisceradas, promovem uma série de modificações ao paciente tanto funcional do órgão quanto psicológica e estética. Para tanto a procura de um material de baixo custo e com biocompatibilidade tem sido uma constante na literatura. Portanto, esse trabalho teve como objetivo testar experimentalmente implante de polietileno granulado de ultra-alto peso molecular, material de baixo custo, em órbitas de coelhos submetidos à evisceração cirúrgica em vários tempos experimentais, onde foram avaliados aspectos macroscópicos e microscópicose de toxicidade sistêmica do material. MÉTODOS: Para esse estudo foram utilizados coelhos Oryctolaguscuniculus submetidos à evisceração do globo ocular direito e posteriormente implantados com esfera de polietileno granulado de ultra-alto peso molecular e analisados por 15, 30, 90 e 180 dias pós-implante, com parâmetros macro, microscópios e bioquímicos. Os animais controles foram submetidos ao mesmo procedimento sem, entretanto a colocação do implante. RESULTADOS: Os resultados desse trabalho mostram que o material utilizado no implante de cavidade não apresenta alteração significativa nos parâmetros de peso e bioquímicos quando comparados ao grupo controle. O material implantado apresentou uma grande interação com o tecido do hospedeiro. CONCLUSÃO: Os resultados indicam que implante de polietileno granulado de alto peso molecular desenvolvido por uma indústria nacional tem alto potencial para se realizar testes em humanos.


OBJECTIVE: Ocular changes in special due to volume loss in eviscerated cavities promote several psychological aesthetic and functional alterations to patients. For this reason, searches aiming at finding a material of low cost and biocompatibility have been constantly carried out. Test experimentally the implants constituted of ultra-high molecular weight granular polyethylene oflow cost, in orbits of rabbits subjected to surgical evisceration in several experimental times, evaluating the macro and microscope aspects besides the systemic toxicity of the material. METHODS: In this study we eviscerated the right ocular globe of rabbits of the species Oryctolaguscuniculus, implanted posteriorly a sphere of granular polyethylene of ultrahigh molecular weight and analysed the effects through macro, micro and biochemical parameters during 15, 30, 90 and 180 days after implantation.The control group were submitted the same procedure without the implants. RESULTS: This paper shows that the material used in the cavity does not present significant alteration in the weight and in the biochemistry of the animal; a good assimilation (integration) of the material implanted by the tissue formed was observed inside the implant. CONCLUSION: The results indicate that ultra-high molecular weight granular polyethylene implant developed by a national industry presents excellent integration in the model used supporting further use in tests with humans.


Asunto(s)
Animales , Conejos , Anoftalmos/cirugía , Ojo Artificial , Implantes Orbitales , Evisceración Orbitaria , Polietilenos/uso terapéutico , Ensayo Clínico , Estudios Prospectivos
3.
Arq. bras. oftalmol ; 73(1): 81-83, Jan.-Feb. 2010. ilus
Artículo en Portugués | LILACS | ID: lil-546054

RESUMEN

Apresentamos um novo modelo de implante orbital unindo o baixo custo da esfera de luxite (PMMA) com as vantagens da utilização do polietileno poroso (Porex®). O novo modelo consiste de uma esfera de luxite na qual em sua face anterior foi colocado um recorte de dura-máter do mesmo diâmetro da esfera, e na face posterior um recorte de polietileno poroso foi anexado à esfera de luxite por meio de cola (Cianoacrilato estéril). A dura-máter foi fixada ao polietileno poroso por meio de suturas com fio nylon monofilamentar 6.0. Foi realizada cirurgia em um paciente que já havia tido extrusão anterior do implante em um dos olhos, sendo este avaliado em seu pós-operatório imediato, 7º, 15º, 30º dia, além de 3 e 6 meses de pós-operatório quando foi avaliado por meio de tomografia computadorizada. Observou-se bom resultado cosmético, de mobilidade e de volume após adaptação da prótese escleral, não havendo nenhum sinal de infecção, migração ou extrusão do implante até o momento. O caso nos mostrou ser possível a utilização de um implante orbital mais acessível economicamente com resultados semelhantes aos dos implantes biointegráveis.


A new model of orbital implant, matching the low cost of acrylic implants (PMMA) with the advantages of medpor (Porex®) is presented herein. The new implant model consists of a PMMA implant with a dura mater scrap adhered on its anterior face of the same diameter of the acrylic implant and a medpor snip adhered on its posterior face by sterile cyanoacrylate. Dura mater was fixed to medpor with 6.0 mononylon. One patient who presented previous extrusion of the implant was submited to surgery and was evaluated on the 1st, 7th, 15th, 30th postoperative days, and 3 and 6 months after surgery when a computed tomography was performed. A good cosmetic, mobility and volume result was noted after an escleral prosthesis was adapted, with no infection, migration or extrusion of the implant until this moment. This case showed us that it is possible to use a more economic implant model with the same results of medpor (Porex®).


Asunto(s)
Adulto , Femenino , Humanos , Anoftalmos/cirugía , Ojo Artificial , Implantes Orbitales , Estudios de Seguimiento , Diseño de Prótesis , Tomografía Computarizada por Rayos X , Resultado del Tratamiento
4.
Korean Journal of Otolaryngology - Head and Neck Surgery ; : 928-931, 2009.
Artículo en Coreano | WPRIM | ID: wpr-648371

RESUMEN

Enophthalmos means displacement of the globe into the bony orbit backward, and usually downward. In post-traumatic enophthalmos, the mechanisms that determine the globe position can be the enlargement of the orbital cavity, the herniation of orbital fat into the maxillary sinus, fat atrophy, loss of ligament support, and scar contracture. It can be reconstructed through several approaches such as transconjunctival, canthotomy, lower eye lid, coronal approach, and by using bone, cartilage, and alloplastic materials. The authors report a case of postoperative enophthalmos reconstructed through subciliary and transnasal endoscopic approaches using porous polyethylene with embedded titanium.


Asunto(s)
Humanos , Atrofia , Cartílago , Cicatriz , Contractura , Desplazamiento Psicológico , Endoscopios , Enoftalmia , Ojo , Ligamentos , Seno Maxilar , Órbita , Polietileno , Polietilenos , Titanio
5.
Arq. bras. oftalmol ; 70(2): 221-224, mar.-abr. 2007. ilus
Artículo en Portugués | LILACS | ID: lil-453159

RESUMEN

OBJETIVO: Avaliar a ligação entre músculos oculares extrínsecos e esferas de polietileno poroso usando um bioadesivo. MÉTODOS: Estudo experimental envolvendo 8 coelhos albinos submetidos a enucleação do olho direto com colocação de implante esférico de polietileno poroso de 12 mm de diâmetro unido aos músculos oculares extrínsecos por meio do bioadesivo 2-octil-cianoacrilato. Noventa dias após a cirurgia os animais foram sacrificados e o conteúdo orbitário removido. Em 4 animais foi realizado estudo biomecânico, avaliando-se a força de ruptura entre a musculatura e a esfera (grupo implante) e entre a musculatura e a esclera nos olhos contralaterais (grupo controle). Nos outros 4 animais foi realizada análise histológica. RESULTADO: A avaliação biomecânica revelou que a força de ruptura entre esfera-músculo e esclera-músculo foram semelhantes quando se usa o adesivo de cianoacrilato. O exame histológico mostrou reação fibrovascular no local da adesão entre a musculatura e a esfera, sem efeitos deletérios aos tecidos. Ao redor dos implantes foi possível observar pseudocápsula e no interior, neovasos e tecido fibrovascular preenchendo os espaços entre os grânulos do polietileno. CONCLUSÃO: O adesivo 2-octil-cianoacrilato mantém boa força de adesão na união entre os músculos e as esferas de polietileno poroso, com redução do tempo cirúrgico e sem efeitos deletérios aos tecidos orbitais. Desta forma, deve-se considerar o uso do bioadesivo na reconstrução da cavidade anoftálmica.


PURPOSE: To evaluate fixation by a bioadhesive of the external ocular muscles to the porous polyethylene spheres. METHODS: An experimental study was performed using eight white rabbits that underwent right eye enucleation with placement of 12 mm spheres of porous polyethylene. The rectus muscles (superior and inferior) were attached to the implant with a bioadhesive (2-octyl-cyanoacrylate) applied to the inferior side of the external muscles. Ninety days after surgery the orbital content was removed and 4 animals were submitted to a tensile strength test of the muscle-sphere attachment and the other 4 to histological evaluation. RESULTS: The tensile strength test showed that the rupture force was similar between the muscle and porous polyethylene sphere bond attachment and normal external ocular muscles. The histologic evaluation showed fibrous tissue reaction and muscle-sphere attachment with no deleterious effects to the tissues; a capsule formation around the spheres and new vessels inside the implant were also observed. CONCLUSION: 2-octyl-cyanoacrylate provides strength adhesion between muscles and spheres, with surgery time reduction and does not provoke deleterious effects on the orbital tissues. Thus, the bioadhesive might be a good choice for use in the anophthalmic cavity reconstruction.


Asunto(s)
Animales , Conejos , Cianoacrilatos/uso terapéutico , Implantes Orbitales , Músculos Oculomotores/efectos de los fármacos , Órbita/cirugía , Polietilenos , Adhesivos Tisulares/uso terapéutico , Cianoacrilatos , Enucleación del Ojo , Modelos Animales , Músculos Oculomotores/cirugía , Órbita/patología , Porosidad , Resistencia a la Tracción/fisiología
6.
Chinese Journal of Medical Aesthetics and Cosmetology ; (6)2002.
Artículo en Chino | WPRIM | ID: wpr-536738

RESUMEN

Objective To evaluate the clinical effect of Medpor ( porous high density polyethylene )as a padding material in correction of sunken eyelid after hydroxyapatite (HA) implantation. Methods We used Medpor in 17 patients ( 10 male and 7 female ), aged from 18 to 43 years (mean 26.6 years ), in which 9 cases had concomitant orbital fractures. The Medpor was implanted after HA sphere implantation ranged from 2 to 19 months ( average 6.7 months ). 17 consecutive patients with implantation of HA sphere were filled with Medpor under the periosteum. All of the cases were examined by CT scanning to distinguish orbital lesions with or without fracture. In the orbital fracture cases, we first repaired orbit bone defects with Medpor. Results There were no secondary infection or implant rejection occurred after following up for 1 to 18 months (average 8.7 months ). All patients' cosmesis was acceptable. 14 of 17 patients gained symmetric appearance. Although 3 patients had slight sunken eyelid, they gained a dramatic improvement of facial appearance nevertheless. Conclusions Sunken eyelid after HA sphere implant is related with orbital fracture as well as relative reduction of orbital content. Medpor presents fine biological compatibility. It is also easy to remodel and fix during operation. Medpor is a good implant for treatment of sunken eyelid after HA sphere orbital implantaion. [

7.
Ophthalmology in China ; (6)1993.
Artículo en Chino | WPRIM | ID: wpr-551397

RESUMEN

Corneal neovascularization(CNV)is one of the main causes of corneal allograft rejection.We have developed a CNV model in rabbits by controlled- release of IL-2.Its characterization and developmental processes were observed and its histological mechanism was explored.CNV was revealed through staining of erythrocytes within capillaries with 3,3′-diaminoben- zidine(DAB).Ethylene vinyl acetate copolymer (EVA-40)pellets incorporated with IL-2 100u,200u, 500u and control blank pellets were implanted in corneal mid-stromal pocket 2mm from the upper limbus.Biomicroscopic evaluation revealed that IL-2 induced CNV in a dose-dependent manner.IL-2 500u induced CNV in all the experimental eyes with good consistency and reproducibility.Histopathologi- cally,the IL-2 induced CNV was closely associated with mononuclear cell infiltration.This model fairly closely mimicked the immunologically mediated CNV. The architecture and perfusion of CNV was clearly revealed by the red blood cells stained with DAB.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA