Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Añadir filtros








Intervalo de año
1.
Acta ortop. bras ; 30(1): e253870, 2022. tab, graf
Artículo en Inglés | LILACS-Express | LILACS | ID: biblio-1355582

RESUMEN

ABSTRACT Introduction To compare the functional results, satisfaction rates, and revisions of total knee arthroplasties performed by the same surgical team using either Brazilian or imported implants, with a minimum follow-up of 5 years after surgery. Materials and Methods A retrospective cohort study analyzing the medical records and interviews of patients who underwent total knee arthroplasty with Brazilian or imported implants with a minimum of 5 years after surgery. Results One hundred and fifty patients were evaluated (164 knees). In the functional questionnaire, 71% of patients had favorable answers in the group of patients who underwent surgery using the Brazilian prosthesis and 74.8% in the group with imported implants (p=0.634). There was no statistical difference in satisfaction between the groups, with 78.4% of patients satisfied or very satisfied in the Brazilian implant group and 90.7% in the imported implant group (p=0.053). Loosening of the implants was reported in 5.3% versus 4.7% (p>0.999). Conclusion The total knee arthroplasties performed by the same surgical team with a minimum follow-up period of 5 years showed similar levels of satisfaction, function, and complications with both the Brazilian and imported implants. Level of Evidence III, cohort study.


RESUMO Introdução Comparar resultados funcionais, índices de satisfação e revisões de artroplastias totais de joelho realizadas pela mesma equipe cirúrgica usando implantes brasileiros ou importados, com acompanhamento mínimo de cinco anos após a cirurgia. Material e Método Estudo de coorte retrospectivo com análise de prontuários e entrevistas de pacientes submetidos à artroplastia total do joelho com implantes brasileiros e importados com no mínimo cinco anos de pós-operatório. Resultados Foram avaliados 150 pacientes (164 joelhos). No questionário funcional, encontramos 71% dos pacientes com respostas favoráveis no grupo de pacientes submetidos à cirurgia com uso de próteses brasileiras e 74,8% no grupo com implantes importados (p = 0,634). Em relação à satisfação, não houve diferença estatística entre os grupos com 78,4% dos pacientes satisfeitos ou muito satisfeitos no grupo com implante brasileiro e 90,7% no grupo com implante importado (p = 0,053). A ocorrência de soltura dos implantes foi relatada em 5,3% versus 4,7% (p > 0,999). Conclusões As artroplastias totais de joelho realizadas pela mesma equipe cirúrgica com acompanhamento mínimo de cinco anos apresentaram níveis semelhantes de satisfação, função e complicações com os implantes brasileiros e importados. Nível de evidência III, estudo de coorte.

2.
Rev. bras. ortop ; 53(5): 632-635, Sept.-Oct. 2018. graf
Artículo en Inglés | LILACS | ID: biblio-977890

RESUMEN

ABSTRACT The authors report the first case of traumatic late dissociation of the polyethylene insert with patellar tendon rupture after total knee arthroplasty using a high-flex posterior-stabilized Genesis II prosthesis in a 60-year-old Parkinson's disease patient. Insert dislodgement has been described most commonly with mobile-bearing and cruciate-retaining TKAs. Only four cases of insert dissociation in a high-flex fixed-bearing prosthesis have been described to date. This case report paves the way to understanding the potential reasons for insert dissociation and its management strategy.


RESUMO Os autores relatam o primeiro caso de dissociação tardia traumática do inserto de polietileno com ruptura do tendão patelar após artroplastia total do joelho, com o uso de uma prótese Genesis II de alta flexibilidade e estabilização posterior, em paciente com 60 anos com doença de Parkinson. A luxação do inserto plástico tem sido mais comumente descrita em ATJs com suporte de carga móvel e que pouparam o ligamento cruzado. Até o presente, foram descritos apenas quatro casos de dissociação dos insertos de polietileno em próteses de suporte fixo e alta flexibilidade. Este relato de caso abre caminho para a compreensão das potenciais causas de dissociação inserto de polietileno e sua conduta.


Asunto(s)
Humanos , Femenino , Persona de Mediana Edad , Artroplastia , Diseño de Prótesis , Artroplastia de Reemplazo , Articulación de la Rodilla , Prótesis de la Rodilla
3.
Med. reabil ; 31(1): 17-21, jan.- abr. 2012. tab
Artículo en Portugués | LILACS | ID: lil-775825

RESUMEN

O objetivo deste estudo foi elaborar um programa de reabilitação para pacientes com tumor de células giagantes com endoprótese não convencional em fêmur distal. Foi realizado um levantamento bibliográfico de artigos e livros, através das bases de dados: CAPES, Medline, e Biblioteca de Ciências Médicas da Santa Casa de São Paulo com as palavras-chaves: endoprótese, tumor de células gigantes, reabilitação, fadiga, joelho. O programa proposto tem duração de seis meses, dividido em: fase pré-operatória, hospitalar e ambulatorial. A reabilitação em pacientes com endoprótese não convencional deve ser adaptada à condição clínica do paciente e visar a funcionalidade e qualidade de vida.


Asunto(s)
Humanos , Masculino , Femenino , Tumor Óseo de Células Gigantes , Prótesis de la Rodilla , Rehabilitación
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA