RESUMEN
Objective To explore the role of the improved computer aided design of the digital three -dimensional titanium mesh in the repair of skull,to reduce the incidence of postoperative epidural hematoma and epidural fluid.Methods Retrospective analysis of 93 cases of skull repair using the three -dimensional titanium mesh was conducted.49 cases in the conventional group used the conventional three -dimensional titanium mesh. 44 cases in the observation group were given the improved three -dimensional titanium mesh.The clinical effect of the two groups was observed.Results In the conventional group,postoperative epidural hematoma occurred in 4 cases, 1 case of epidural fluid.All patients were fine in the observation group.The improved three -dimensional titanium mesh could reduce the incidence of epidural hematoma and effusion(χ2 =4.745,P =0.029).The conventional group and the observation group both had one case of infection after operation,there was no significant difference between the two groups(χ2 =0.001,P =1.000).Conclusion The improved three -dimensional titanium mesh can effective-ly reduce the incidence of postoperative complications and improve the curative effect of the operation.