Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 993
Filtrar
1.
Int. j. morphol ; 42(2)abr. 2024.
Artículo en Inglés | LILACS-Express | LILACS | ID: biblio-1558122

RESUMEN

SUMMARY: Over time, Goldner's trichrome staining has been essential in paraffin soft tissue research. However, its classic application involves prior decalcification, generating disadvantages in the integrity of the samples and the interpretation of results. This study seeks to overcome the limitations associated with decalcification when applying Goldner's trichrome stain with plastic resins. It focuses on detailed visualization of non-decalcified bone and dental samples in animal models. Samples of jaw and tooth from a dog (Canis familiaris) were used, as well as tibia from a rabbit (Oryctolagus cuniculus) with a titanium dental implant and bone graft substitute. Adjustments were made to the original protocol, including a surface treatment prior to staining. Plastination and inclusion in specific plastic resins were part of the process. The microplastinated and stained samples showed optimal quality for optical microscopy. Those from dogs allowed detailed observation of the tooth-periodontal tissue relationship, while those from rabbits revealed a clear differentiation between mineralized and osteoid bone tissue. The staining made it easy to examine the precise interface between soft tissues, bone graft, and implant. The successful adaptation of Goldner's trichrome stain to specimens in plastic resins represents a significant advance in histological investigation of hard tissues. This methodology stands out as an effective tool to evaluate implants and biomaterials in animal models, providing detailed visualization without compromising the integrity of the samples. The combination of histochemistry and plastic resins offers a valuable alternative for microanatomical studies, opening new possibilities in hard tissue research and evaluation of bone structures.


A lo largo del tiempo, la tinción tricrómica de Goldner ha sido esencial en la investigación de tejidos blandos en parafina. Sin embargo, su aplicación clásica conlleva la descalcificación previa, generando desventajas en la integridad de las muestras y la interpretación de resultados. Este estudio busca superar las limitaciones asociadas con la descalcificación al aplicar la tinción tricrómica de Goldner con resinas plásticas. Se enfoca en visualizar detalladamente muestras óseas y dentales no descalcificadas en modelos animales. Se emplearon muestras de mandíbula y diente de perro (Canis familiaris), así como tibia de conejo (Oryctolagus cuniculus) con implante dental de titanio y substituto de injerto óseo. Se realizaron ajustes al protocolo original, incluyendo un tratamiento superficial previo a la tinción. La plastinación y la inclusión en resinas plásticas específicas fueron parte del proceso. Las muestras microplastinadas y teñidas mostraron una calidad óptima para microscopía óptica. Las de perro permitieron la observación detallada de la relación diente-tejido periodontal, mientras que las de conejo revelaron una clara diferenciación entre tejido óseo mineralizado y osteoide. La tinción facilitó examinar la interface precisa entre tejidos blandos, injerto óseo e implante. La adaptación exitosa de la tinción tricrómica de Goldner a muestras en resinas plásticas representa un avance significativo en la investigación histológica de tejidos duros. Esta metodología destaca como una herramienta eficaz para evaluar implantes y biomateriales en modelos animales, brindando una visualización detallada sin comprometer la integridad de las muestras. La combinación de histoquímica y resinas plásticas ofrece una alternativa valiosa para estudios microanatómicos, abriendo nuevas posibilidades en la investigación de tejidos duros y evaluación de estructuras óseas.

2.
J. appl. oral sci ; 32: e20230397, 2024. tab, graf
Artículo en Inglés | LILACS-Express | LILACS | ID: biblio-1558244

RESUMEN

Abstract Specific products containing natural resources can contribute to the innovation of complete denture hygiene. Objective: To conduct an in vitro evaluation of experimental dentifrices containing essential oils of Bowdichia virgilioides Kunth (BvK), Copaifera officinalis (Co), Eucalyptus citriodora (Ec), Melaleuca alternifolia (Ma) and Pinus strobus (Ps) at 1%. Methodology: The variables evaluated were organoleptic and physicochemical characteristics, abrasiveness (mechanical brushing machine) simulating 2.5 years, and microbial load (Colony Forming Units - CFU/mL), metabolic activity (XTT assay) and cell viability (Live/Dead® BacLight™ kit) of the multispecies biofilm (Streptococcus mutans: Sm, Staphylococcus aureus: Sa, Candida albicans: Ca and Candida glabrata: Cg). Specimens of heat-polymerized acrylic resins (n=256) (n=96 specimens for abrasiveness, n=72 for microbial load count, n=72 for biofilm metabolic activity, n=16 for cell viability and total biofilm quantification) with formed biofilm were divided into eight groups for manual brushing (20 seconds) with a dental brush and distilled water (NC: negative control), Trihydral (PC: positive control), placebo (Pl), BvK, Co, Ec, Ma or Ps. After brushing, the specimens were washed with PBS and immersed in Letheen Broth medium, and the suspension was sown in solid specific medium. The organoleptic characteristics were presented by descriptive analysis. The values of density, pH, consistency and viscosity were presented in a table. The data were analyzed with the Wald test in a generalized linear model, followed by the Kruskal-Wallis test, Dunn's test (mass change) and the Bonferroni test (UFC and XTT). The Wald test in Generalized Estimating Equations and the Bonferroni test were used to analyze cell viability. Results: All dentifrices showed stable organoleptic characteristics and adequate physicochemical properties. CN, Ec, Ps, Pl and PC showed low abrasiveness. There was a significant difference between the groups (p<0.001) for microbial load, metabolic activity and biofilm viability. Conclusions: It was concluded that the BvK, Ec and Ps dentifrices are useful for cleaning complete dentures, as they have antimicrobial activity against biofilm. The dentifrices containing Bowdichia virgilioides Kunth showed medium abrasiveness and should be used with caution.

3.
J. appl. oral sci ; 32: e20230326, 2024. tab, graf
Artículo en Inglés | LILACS-Express | LILACS | ID: biblio-1558246

RESUMEN

Abstract Studies evaluating the roughness, wettability and microbial adhesion of 3D-printed resins for complete denture bases and teeth are scarce. Objective This study evaluated the surface roughness, wettability and adhesion of multispecies biofilms (Candida albicans, Staphylococcus aureus and Streptococcus mutans) on 3D-printed resins for complete denture bases and teeth compared to conventional resins (heat-polymerized acrylic resin; artificial pre-fabricated teeth). Methodology Circular specimens (n=39; 6.0 mm Ø × 2.0 mm) of each group were subjected to roughness (n=30), wettability (n=30) and biofilm adhesion (n=9) tests. Three roughness measurements were taken by laser confocal microscopy and a mean value was calculated. Wettability was evaluated by the contact angle of sessile drop method, considering the mean of the three evaluations per specimen. In parallel, microorganism adhesion to resin surfaces was evaluated using a multispecies biofilm model. Microbial load was evaluated by determining the number of Colony Forming Units (CFU/mL) and by scanning electron microscopy (SEM). Data were subjected to the Wald test in a generalized linear model with multiple comparisons and Bonferroni adjustment, as well as two-way ANOVA (α=5%). Results The roughness of the conventional base resin (0.01±0.04) was lower than that of the conventional tooth (0.14±0.04) (p=0.023) and 3D-printed base (0.18±0.08) (p<0.001). For wettability, conventional resin (84.20±5.57) showed a higher contact angle than the 3D-printed resin (60.58±6.18) (p<0.001). Higher microbial loads of S. mutans (p=0.023) and S. aureus (p=0.010) were observed on the surface of the conventional resin (S. mutans: 5.48±1.55; S. aureus: 7.01±0.57) compared to the 3D-printed resin (S. mutans: 4.11±1.96; S. aureus: 6.42±0.78). The adhesion of C. albicans was not affected by surface characteristics. The conventional base resin showed less roughness than the conventional dental resin and the printed base resin. Conclusion The 3D-printed resins for base and tooth showed less hydrophobicity and less adhesion of S. mutans and S. aureus than conventional resins.

4.
Pesqui. bras. odontopediatria clín. integr ; 24: e220113, 2024. tab, graf
Artículo en Inglés | LILACS, BBO | ID: biblio-1529140

RESUMEN

Abstract Objective: To evaluate the effect of different pressures of an oral irrigation device (OID) and the irrigation solution type on the surface roughness of the giomer restorative material. Material and Methods: In this in vitro study, disk-shaped giomer samples were fabricated and assigned to 5 groups (n=23): Group 1, storage in distilled water (control); Group 2, OID #7 pressure/ water; Group 3, OID #10 pressure/ water; Group 4, OID #7 pressure/ 0.05% CHX; Group 5, OID #10 pressure/ 0.05% CHX. The samples' treatment simulated a one-year application of OID. Surface roughness (Ra) and topography of the giomer were evaluated using profilometry and scanning electron microscopy. The data were analyzed with Paired t-test, Tukey, and ANOVA tests (α=0.05). Results: The Ra of the samples increased significantly after treatment with OID (p<0.001). The roughness increase in groups with a pressure of 10 was higher than those with a pressure of 7 (p<0.001). The effect of pressure on surface changes was significant (p<0.001). However, the solution type and the cumulative effect of these two factors were insignificant (p=0.08 and p=0.43, respectively). Conclusion: Oral irrigation device with both solutions significantly increased the surface roughness and topographic changes of the giomer. The severity of these changes was related to the device's pressure.


Asunto(s)
Biguanidas , Agua Destilada , Clorhexidina/efectos adversos , Resinas Compuestas , Propiedades de Superficie , Técnicas In Vitro/métodos , Análisis de Varianza , Pruebas de Dureza/métodos
5.
Braz. oral res. (Online) ; 38: e003, 2024. tab, graf
Artículo en Inglés | LILACS-Express | LILACS, BBO | ID: biblio-1528147

RESUMEN

Abstract Resin composites containing surface pre-reacted glass (S-PRG) have been introduced to reduce demineralization and improve remineralization of the tooth structure. However, water diffusion within the material is necessary for its action, which can impair its overall physicomechanical properties over time, including color stability. This study aimed to evaluate the color stability and related degree of conversion (DC) of four resin composites. Discs (6 x 4 mm, n = 5/group) of microhybrid (MH), nanofilled (NF), nanohybrid (NH), and S-PRG-based nanohybrid (S-PRG-NH) composites with two opacities (A2/A2E and A2O/A2D) were prepared. Color (CIELab and CIEDE2000) was evaluated with a spectrophotometer after aging in grape juice (2 x 10 min/10mL/7days). The DC was analyzed by using Fourier transform infrared spectroscopy before and after light-curing. Data were statistically analyzed by using two-way analysis of variance and post-hoc least significant difference tests (p<0.05). In the color stability analysis, the interaction between filler type and opacity was significant (CIELab, p = 0.0015; CIEDE2000, p = 0.0026). NH presented the highest color stability, which did not differ from that of MH. The greatest color alteration was observed for S-PRG-NH. S-PRG fillers also influenced DC (p < 0.05). The nanohybrid resin composite presented favorable overall performance, which is likely related to its more stable organic content. Notwithstanding the benefits of using S-PRG-based nanohybrid resins, mostly in aesthetic procedures, professionals should consider the susceptibility of such resins to color alteration, probably due to the water-based bioactive mechanism of action.

6.
J. appl. oral sci ; 32: e20230219, 2024. tab, graf
Artículo en Inglés | LILACS-Express | LILACS | ID: biblio-1528890

RESUMEN

Abstract Objective: In this study, a comparative evaluation of the physicochemical properties of Cention N and other direct restorative materials was performed. Three restorative materials—a resin-modified glass ionomer (Fuji II LC), an alkasite-based resinous material (Cention N), and a resin composite (Tetric N Ceram)—were characterized in terms of degree of conversion, Knoop hardness number (KHN) ratio, flexural strength, elastic modulus, water sorption, water solubility, microshear bond strength to dentin, immediate microleakage, and radiopacity. Methodology: The microshear bond strength to dentin and microleakage of Cention N were evaluated with and without the application of an adhesive system (Tetric N Bond Universal). A one-way ANOVA test was used to analyze the data in terms of degree of conversion, KHN ratio, water sorption, water solubility, microshear bond strength to dentin, and radiopacity. A two-way ANOVA test (carried out considering the material type and ethanol aging as factors) was used to analyze the data in terms of flexural strength and elastic modulus. The Kruskal-Wallis test was used to statistically analyze the data on microleakage. A significance level of α=0.05 was used for all tests. Results: Fuji II LC was found to have the highest degree of conversion, water sorption, and microleakage, as well as the lowest flexural strength. Cention N had the highest solubility; when used with an adhesive system, it achieved bond strength and microleakage similar to those of the Tetric N Ceram composite. Tetric N Ceram had the highest degree of conversion, KHN ratio, and radiopacity. Conclusion: The properties of Cention N validate its efficacy as an alternative direct restorative material when used in conjunction with an adhesive system.

7.
Braz. j. oral sci ; 23: e241938, 2024. ilus
Artículo en Inglés | LILACS, BBO | ID: biblio-1532506

RESUMEN

Aim: To evaluate changes in the surface roughness and morphology of a nanofilled composite following toothbrushing with a whitening (WT) or regular toothpaste (RT), alone or combined with 35% hydrogen peroxide bleaching (HP). Methods: Seventy disc-shaped nanofilled composite (Filtek Z350XT) specimens were randomly divided into groups (n=10): WT, RT, TB (without toothpaste ­ control) or the combinations WT/ HP, RT/HP, TB/HP and HP. All groups underwent toothbrushing simulation (60,000 cycles) and bleaching treatment (4 sessions). Mean surface roughness (Ra, µm) was measured before (T0) and after treatments (TB). Surface morphology was assessed by scanning electron microscopy (SEM) at TB. Mean Ra was analyzed using general mixed models and multiple comparisons by the Tukey-Kramer test (α=5%). Results: HP caused no surface roughness changes on the nanofilled composite after treatment (p>0.05). RT toothbrushing, combined or not with HP, increased the surface roughness (p<0.05). WT and WT/ HP protocols had no effect on the surface roughness of the composite (p>0.05). The nanofilled composite submitted to RT toothbrushing combined with HP (RT/HP) presented substantial surface alterations under SEM, showing deep depressions and round-shaped defects. Toothbrushing with RT combined with the bleaching agent increased exposure of the inorganic fillers. Conclusion: WT toothbrushing, regardless of HP combination, or the single HP protocol had no effect on the surface roughness of the nanofilled composite. However, RT combined with HP negatively affected surface roughness and presented the most noticeable surface changes among groups


Asunto(s)
Blanqueamiento de Dientes , Pastas de Dientes , Microscopía Electrónica de Rastreo , Resinas Compuestas , Peróxido de Hidrógeno
8.
Braz. j. oral sci ; 23: e240398, 2024. tab
Artículo en Inglés | LILACS, BBO | ID: biblio-1553456

RESUMEN

Aim: This study aimed to assess the polymerization effectiveness of bulk-fill composite resins in longitudinal microhardness. Methods: Blocks of bulk-fill composite resin with thicknesses of 6 mm were analyzed with Vickers microhardness. The resin blocks were divided into two groups (n=6): resin AURA and OPUS. The microhardness test was performed before (base and top) and after (longitudinal microhardness) sectioning the blocks at distances of 2 mm, 4 mm, and 6 mm from the top of the block. The mean microhardness values were tabulated and subjected to ANOVA followed by Tukey's test (p<0.05). Results: The OPUS bulk-fill resin samples presented microhardness means of 55.9 kgf/mm2, 53.7 kgf/mm2, and 49.3 kgf/mm2, the AURA bulk-fill resin samples presented microhardness means of 57,02 kgf/mm2, 55,86 kgf/mm2 e 51,77 kgf/mm2 for the distances of 2 mm, 4 mm, and 6 mm, respectively. Tukey's statistical test showed a significant difference in microhardness values at different distances of 2 mm, 4 mm, and 6 mm (p<0.001) for each resin. Although there was a statistically significant difference within and between the groups assessed, all samples showed polymerization effectiveness when comparing the top and base of the block. Conclusion: Polymerization was effective in different thicknesses (2 mm, 4 mm, and 6 mm) in both resins studied. The microhardness ratio was adequate when comparing the base and top


Asunto(s)
Eficacia , Resinas Compuestas , Polimerizacion , Dureza
9.
Braz. dent. j ; 35: e24, 2024. tab, graf
Artículo en Inglés | LILACS-Express | LILACS, BBO | ID: biblio-1550091

RESUMEN

Abstract This research aimed to evaluate the effect of the radiopacity of a Bulk-Fill composite (X-TraFil, VOCO, Germany) and a Conventional composite (P60, 3M ESPE, USA) and assessment of the margin location in the enamel and dentin on the diagnosis of secondary caries. 76 intact premolars with MOD preparation were divided into two equal groups and filled with the conventional and bulk-fill composite. Four regions were considered to simulate carious lesions (two regions in enamel and two regions in dentin). In each group, half of the regions in the dentin and half in the enamel were randomly selected for secondary caries simulation and filled with a wax-plaster combination while the remaining regions stayed intact. Bitewing imaging was done using the PSP digital sensor. Five examiners reviewed the images, and lesions were recorded. Caries diagnosis indicators and paired-sample t-test were used for statistical analysis. The reproducibility and accuracy of the examiners' responses were evaluated using the kappa and agreement coefficient (α=0.05). The sensitivity, specificity, and accuracy of diagnosing secondary carious lesions in enamel were significantly better under conventional than bulk-fill composite. Similarly, the sensitivity and accuracy of diagnosing secondary caries in dentin were significantly higher under conventional composite than bulk-fill composite (p<0.05). No significant differences were found in the agreement and kappa coefficient between conventional and bulk-fill composites in the enamel and dentin (p>0.05). The diagnostic accuracy of carious lesions was higher under conventional composite than bulk-fill composite. However, the location of the secondary was ineffective in caries diagnosis.


Resumo Essa pesquisa teve como objetivo avaliar o efeito da radiopacidade de resina composta Bulk-Fill (X-TraFil, VOCO, Alemanha) e de resina composta convencional (P60, 3M ESPE, EUA) e a avaliação da localização da margem no esmalte e na dentina no diagnóstico de cárie secundária. 76 pré-molares intactos com preparo MOD foram divididos em dois grupos iguais e restaurados de acordo com o grupo experimental. Quatro regiões foram consideradas para simular lesões de cárie (duas regiões no esmalte e duas regiões na dentina). Em cada grupo, metade das regiões na dentina e metade no esmalte foram selecionadas aleatoriamente para a simulação de cárie secundária e preenchidas com uma combinação de cera e gesso, enquanto as regiões restantes permaneceram intactas. As imagens de bitewing foram feitas usando o sensor digital PSP. Cinco examinadores analisaram as imagens, e as lesões foram registradas. Os indicadores de diagnóstico de cárie e o teste t de amostra pareada foram usados para análise estatística. A reprodutibilidade e a precisão das respostas dos examinadores foram avaliadas usando o kappa e o coeficiente de concordância (α=0,05). A sensibilidade, a especificidade e a precisão do diagnóstico de lesões cariosas secundárias no esmalte foram significativamente melhores com a resina composta convencional do que com a resina composta bulk-fill. Da mesma forma, a sensibilidade e a precisão do diagnóstico de cáries secundárias na dentina foram significativamente maiores com a resina convencional do que com a resina bulk-fill (p<0,05). Não foram encontradas diferenças significativas na concordância e no coeficiente kappa entre as resinas convencionais e bulk-fill no esmalte e na dentina (p>0,05). A precisão do diagnóstico de lesões cariosas foi maior com a resina composta convencional do que com a resina composta bulk-fill. Entretanto, a localização do secundário foi ineficaz no diagnóstico de cárie.

10.
J. appl. oral sci ; 32: e20230278, 2024. tab, graf
Artículo en Inglés | LILACS-Express | LILACS | ID: biblio-1550476

RESUMEN

Abstract Objective The present in vitro study incorporated niobium oxyhydroxide fillers into an experimental high-viscosity bulk-fill resin composite to improve its mechanical performance and provide it a bioactive potential. Methodology Scanning electron microscopy synthesized and characterized 0.5% niobium oxyhydroxide fillers, demonstrating a homogeneous morphology that represented a reinforcement for the feature. Fillers were weighed, gradually added to the experimental resin composite, and homogenized for one minute, forming three groups: BF (experimental high-viscosity bulk-fill resin composite; control), BF0.5 (experimental high-viscosity bulk-fill resin composite modified with 0.5% niobium oxyhydroxide fillers), and BFC (commercial bulk-fill resin composite Beautifil Bulk U, Shofu; positive control). In total, 10 specimens/groups (8 × 2 × 2 mm) underwent flexural strength (FS) tests in a universal testing machine (Instron) (500N). Resin composites were also assessed for Knoop hardness (KH), depth of cure (DoC), degree of conversion (DC), elastic modulus (E), and degree of color change (ΔE). The bioactive potential of the developed resin composite was evaluated after immersing the specimens into a simulated body fluid in vitro solution and assessing them using a Fourier-transformed infrared spectroscope with an attenuated total reflectance accessory. One-way ANOVA, followed by the Tukey's test (p<0.05), determined FS, DC, KH, and ΔE. For DoC, ANOVA was performed, which demonstrated no significant difference between groups (p<0.05). Conclusions The high-viscosity bulk-fill resin composite with 0.5% niobium oxyhydroxide fillers showed promising outcomes as reinforcement agents and performed well for bioactive potential, although less predictable than the commercial resin composite with Giomer technology.

11.
Braz. oral res. (Online) ; 38: e032, 2024. tab, graf
Artículo en Inglés | LILACS-Express | LILACS, BBO | ID: biblio-1557352

RESUMEN

Abstract This study assessed the reliability of a color measurement method using images obtained from a charge-coupled device (CCD) camera and a stereoscopic loupe. Disc-shaped specimens were created using the composite Filtek Z350 XT (shades DA1, DA2, DA3, and DA4) (n = 3). CIELAB color coordinates of the specimens were measured using the spectrophotometer SP60 over white and black backgrounds. Images of the same specimens were taken using a CCD camera attached to a stereoscopic loupe. The color of the image was measured (red-green-blue [RGB]) using an image processing software and converted to CIELAB coordinates. For each color coordinate, data from images were adjusted using linear regressions predicting those values from SP60. The whiteness index for dentistry (WID) and translucency parameter (TP00) of the specimens as well as the color differences (ΔE00) among pairwise shades were calculated. Data were analyzed via repeated-measures analysis of variance and Tukey's post hoc test (α = 0.05). Images obtained using the loupe tended to be darker and redder than the actual color. Data adjustment resulted in similar WID, ΔE00, and TP00 values to those observed for the spectrophotometer. Differences were observed only for the WID of shade DA3 and ΔE00 for comparing DA1 and DA3 over the black background. However, these differences were not clinically relevant. The use of adjusted data from images taken using a stereoscopic loupe is considered a feasible method for color measurement.

12.
Braz. oral res. (Online) ; 38: e030, 2024. tab, graf
Artículo en Inglés | LILACS-Express | LILACS, BBO | ID: biblio-1557363

RESUMEN

Abstract This study aimed to evaluate volumetric polymerization shrinkage, degree of conversion and Vickers hardness of four bulk-fill resin composites light-activated with their dedicated light curing units (LCUs). Four groups were evaluated, according to the type of composite and curing mode: Tetric EvoCeram Bulk-fill (TEBO) and Tetric EvoFlow Bulk-fill (TEBF) were light-activated with Bluephase Style 20i (20s, in high-mode), while Tetric Powerfill (TEPO) and Tetric Powerflow (TEPF) were light-activated with Bluephase PowerCure (3s). Volumetric polymerization shrinkage test (n = 6) was performed in standardized box-shaped class-I cavities of extracted third molars (4 x 4 x 4 mm). Teeth were scanned before and after resin composite application by micro-computed tomography, and acquired data were evaluated with Amira software. Degree of conversion (n = 5) was evaluated at the top and bottom surfaces of composite cylindric samples (4 mm diameter, 4 mm thickness) using an FT-IR spectrometer (spectra between 1,500 and 1,800 cm-1, 40 scans at a resolution of 4 cm-1). Three Vickers indentations (50 g / 15 s), spaced 500 μm apart, were performed on the top and bottom composite surfaces and averaged. One-way ANOVA was used for data evaluation. TEPF showed the lowest volumetric polymerization shrinkage (p < 0.05), while the other composites were not significantly different within each other (p > 0.05). All materials presented a significant decrease in degree of conversion and Vickers hardness when compared top to bottom surfaces (p < 0.05). Bottom to top surface ratios for degree of conversion ranged from 0.8 (TEBO and TEPO) to 0.9 (TEBF and TEPF), and from 0.4 (TEPO) to 0.7 (TEBF and TEPF) for hardness. In conclusion, resinous materials present a decrease in hardness and degree of conversion from top to bottom even when a higher power is used, while the flowable material TEPF showed the lowest volumetric shrinkage values compared to the other materials.

13.
Pesqui. bras. odontopediatria clín. integr ; 24: e220192, 2024. tab, graf
Artículo en Inglés | LILACS, BBO | ID: biblio-1550593

RESUMEN

ABSTRACT Objective: To investigate the effects of two different dentifrice fluoride concentrations on the color stability of the composite. Material and Methods: Twenty-seven specimens (2×4×5 mm) each of microfilled (Gradia, GC, Japan) and nanohybrid (Grandio, VOCO, Germany) composites were prepared. The specimens were randomly divided into six groups (control, Fluoflor caries protection toothpaste with 1450ppm Fluoride (EXW, France), and Fluoflor kids toothpaste with 500ppm Fluoride (EXW, France) (n = 9). The specimens were immersed in a mixture of artificial saliva and toothpaste in a ratio of 1:3 and applied for 60 seconds every 12 hours for 42 days. The control samples were incubated in artificial saliva at 37°C. Primary and secondary color measurements were performed using color parameters (L∗a∗b) with a spectrophotoshade (MHT Optic Research AG, Niederhasli, Switzerland). Data were analyzed using a two-way analysis of variance at a significance level of 0.05. Results: According to the two-way ANOVA analysis, there was no significant difference in color change between the composites and no difference in the level of discoloration between different fluoride concentrations(p>0.05). Also, None of the dentifrices caused clinically significant color changes(∆E˂3.3). Conclusion: No clinically unacceptable color changes were observed in the microfilled and nanofilled composites with different concentrations of fluoride toothpaste.


Asunto(s)
Pastas de Dientes/química , Color , Resinas Compuestas/química , Fluoruros/química , Técnicas In Vitro/métodos , Análisis de Varianza , Dentífricos
14.
Braz. j. oral sci ; 23: e241390, 2024. ilus
Artículo en Inglés | LILACS, BBO | ID: biblio-1550150

RESUMEN

Aim: To evaluate the surface roughness and color stability of bulk-fill resin composites after simulated toothbrushing with whitening dentifrices. The radioactive/relative dentin abrasion (RDA) and radioactive/relative enamel abrasion (REA) of dentifrices were also assessed. Methods: Specimens (n=10) of Tetric N Ceram Bulk Fill (TNCB), Filtek One Bulk Fill (FOB) resin composites, and Z100(Control) were prepared using a cylindrical Teflon matrix. Surface roughness (Ra, µm) was assessed by a roughness meter and the color evaluations (ΔEab , ΔE00 , WID ) were performed using a digital spectrophotometer based on the CIELAB system. Three measurements were performed per sample, before and after simulated toothbrushing with 3D Oral-B White Perfection (3DW) and Black is White (BW) dentifrices. The abrasivity (REA and RDA values) of the used dentifrices was also determined by the Hefferren abrasivity test. Results: The Ra values increased significantly in all resin composites after 3DW and BW toothbrushing. The acceptable threshold color varied among resin composites, and TNCB and Z100 presented the highest ΔEab and ΔE00 for BW dentifrice. The 3DW dentifrice was significantly more abrasive than BW dentifrice on enamel and dentin. Conclusions: simulated toothbrushing with tested whitening dentifrices increased the surface roughness at acceptable levels. The Tetric N Ceram Bulk-fill and Z100 composite showed the highest color alteration in BW. 3D White Perfection dentifrice was more abrasive on dentin and enamel than Black is White.


Asunto(s)
Color , Resinas Compuestas , Esmalte Dental , Dentífricos , Dentina , Blanqueadores
15.
Rev. Fac. Odontol. Porto Alegre ; 64(1): e130840, dez 2023.
Artículo en Inglés | LILACS-Express | LILACS | ID: biblio-1526324

RESUMEN

Objetivo: Avaliar o efeito de dois métodos de profilaxia sobre a rugosidade superficial de diferentes resinas compostas. Materiais e Métodos: Dez amostras (7 mm x 2 mm) foram confeccionadas para cada resina testada: MH - resina microhíbrida (viscosidade regular - Opallis); NH ­ resina nanohíbrida (viscosidade regular - Vittra APS); BF ­ resina bulk fill (alta viscosidade - Opus Bulk Fill); MHF ­ resina fluida microhíbrida (Opallis flow); e OS ­ resina nanohíbrida camaleão (viscosidade regular - Vittra Unique). Os valores iniciais de rugosidade (Rai) foram obtidos para cada amostra e então subdivididas em dois grupos (n = 5) seguindo o método de profilaxia: SB ­ jato de bicarbonato de sódio (125µm, 30 s, 10 mm de distância, 2 bar); e PP ­ profilaxia com pasta de pedra-pomes e escova rotatória (30 s, 3000 rpm e pressão de 150 g). Após, uma nova medida de Ra (Raf) foi obtida, e a diferença calculada (ΔRa). Os dados foram analisados pelo teste ANOVA três fatores e teste de Bonferroni, e a diferença de rugosidade (ΔRa) pelo teste Anova dois fatores e teste de Tukey (p<0,05). Resultados: MHF apresentou maior rugosidade após profilaxia com jato de bicarbonato, enquanto para NH a abrasão com pedra pomes foi mais deletéria. Para os demais grupos não houve diferença. Discussão: A alteração na rugosidade promovida pela profilaxia é material-dependente. Conclusão: A profilaxia profissional com jato de bicarbonato ou abrasão com pedra-pomes induziu alterações na rugosidade das resinas.


Aim: This study evaluated the effect of two prophylaxis methods over the surface roughness of different resin composites. Materials and Methods: Ten disc-shaped specimens (7 mm x 2 mm) were made for each composite tested: MH - microhybrid composite with regular viscosity (Opallis); NH ­ nanohybrid composite with regular viscosity (Vittra APS); BF ­ high-viscosity bulk fill composite (Opus Bulk Fill); MHF - microhybrid flowable composite (Opallis flow); and OS ­ nanohybrid one-shade composite with regular viscosity (Vittra Unique). Initial roughness (Ra) values were obtained from each sample, and then they were divided into two groups (n = 5) following the prophylaxis method: SB ­ prophylaxis with sodium bicarbonate powder (125µm grain) using an air-powder polishing device (30 s application distanced 10 mm with 2 bar); and PP ­ prophylaxis with pumice paste and rotatory brush (30 s, 3000 rpm and pressure of 150 g). After that, a new Ra measurement (Raf) was obtained, and the difference was calculated (ΔRa). Data were compared using Three-way ANOVA followed by Bonferroni teste and the Ra difference (ΔRa) was analyzed by Two-way ANOVA followed by the Tukey test (p<0.05). Results: MHF presented higher Ra values after receiving prophylaxis with SB, while for NH, the abrasion with pumice increased the Ra, and for the other groups, no differences were found. Discussion: Alteration promoted by prophylaxis is material dependent. Conclusion: Professional prophylaxis with a bicarbonate jet or abrasion with pumice-based paste can induce changes in the composites' roughness.

16.
Rev. Fac. Odontol. Porto Alegre ; 64(1): e130840, dez 2023.
Artículo en Inglés | LILACS-Express | LILACS | ID: biblio-1526407

RESUMEN

Objetivo: Avaliar o efeito de dois métodos de profilaxia sobre a rugosidade superficial de diferentes resinas compostas. Materiais e Métodos: Dez amostras (7 mm x 2 mm) foram confeccionadas para cada resina testada: MH - resina microhíbrida (viscosidade regular - Opallis); NH ­ resina nanohíbrida (viscosidade regular - Vittra APS); BF ­ resina bulk fill (alta viscosidade - Opus Bulk Fill); MHF ­ resina fluida microhíbrida (Opallis flow); e OS ­ resina nanohíbrida camaleão (viscosidade regular - Vittra Unique). Os valores iniciais de rugosidade (Rai) foram obtidos para cada amostra e então subdivididas em dois grupos (n = 5) seguindo o método de profilaxia: SB ­ jato de bicarbonato de sódio (125µm, 30 s, 10 mm de distância, 2 bar); e PP ­ profilaxia com pasta de pedra-pomes e escova rotatória (30 s, 3000 rpm e pressão de 150 g). Após, uma nova medida de Ra (Raf) foi obtida, e a diferença calculada (ΔRa). Os dados foram analisados pelo teste ANOVA três fatores e teste de Bonferroni, e a diferença de rugosidade (ΔRa) pelo teste Anova dois fatores e teste de Tukey (p<0,05). Resultados: MHF apresentou maior rugosidade após profilaxia com jato de bicarbonato, enquanto para NH a abrasão com pedra pomes foi mais deletéria. Para os demais grupos não houve diferença. Discussão: A alteração na rugosidade promovida pela profilaxia é material-dependente. Conclusão: A profilaxia profissional com jato de bicarbonato ou abrasão com pedra-pomes induziu alterações na rugosidade das resinas.


Aim: This study evaluated the effect of two prophylaxis methods over the surface roughness of different resin composites. Materials and Methods: Ten disc-shaped specimens (7 mm x 2 mm) were made for each composite tested: MH - microhybrid composite with regular viscosity (Opallis); NH ­ nanohybrid composite with regular viscosity (Vittra APS); BF ­ high-viscosity bulk fill composite (Opus Bulk Fill); MHF - microhybrid flowable composite (Opallis flow); and OS ­ nanohybrid one-shade composite with regular viscosity (Vittra Unique). Initial roughness (Ra) values were obtained from each sample, and then they were divided into two groups (n = 5) following the prophylaxis method: SB ­ prophylaxis with sodium bicarbonate powder (125µm grain) using an air-powder polishing device (30 s application distanced 10 mm with 2 bar); and PP ­ prophylaxis with pumice paste and rotatory brush (30 s, 3000 rpm and pressure of 150 g). After that, a new Ra measurement (Raf) was obtained, and the difference was calculated (ΔRa). Data were compared using Three-way ANOVA followed by Bonferroni teste and the Ra difference (ΔRa) was analyzed by Two-way ANOVA followed by the Tukey test (p<0.05). Results: MHF presented higher Ra values after receiving prophylaxis with SB, while for NH, the abrasion with pumice increased the Ra, and for the other groups, no differences were found. Discussion: Alteration promoted by prophylaxis is material dependent. Conclusion: Professional prophylaxis with a bicarbonate jet or abrasion with pumice-based paste can induce changes in the composites' roughness.

17.
Rev. Fac. Odontol. Porto Alegre ; 64(1): e123181, dez 2023.
Artículo en Portugués | LILACS-Express | LILACS | ID: biblio-1526439

RESUMEN

Aim: To evaluate the effect of the exposure time and the type of composite in the production of radiographic artifact at the tooth / restorative interface. Materials and Methods: In 20 healthy bovine incisors, cavity preparations and class II restorations were made using composite resins Filtek Bulk Fill One (group 1) and Filtek Z350 (group 2). Then, the teeth were exposed to obtain digital radiographs, varying the exposure time by 0.07, 0.10, 0.14, 0.20 and 0.25s. The images were evaluated for investigation of the presence of artifact through the analysis of the modified number of pixels (QPXD) and the average gray value in class II (MGVR) restorations, using the Image J software (National Health Institute). Results: The presence of artifact was observed in all evaluated samples, regardless of the type of restorative material and the exposure time employed. There was no statistically significant difference in QPXD and MGVR between the resins used (ANOVA 2 factors, p p> 0.05). The MGVR analysis indicated that there were no statistically significant differences between resins or between exposure times (p> 0.05). There was a correlation between QPXD and MGVR (r = 0.29) for Filtek Bulk Fill One resin. Discussion: This study reveals the importance of attention to the region of the tooth-restoration interface by the Surgeon-Dentist, who must combine the radiographic findings diagnosed using digital tools to clinical signs in order to compose a unique therapeutic project with a real need for intervention, if there is such need. Conclusion: The presence of altered pixels on dentin in the region of the tooth-restoration interface was identified in all specimens. The variation in the exposure time as well as the type of the restorative composite did not influence the increase or decrease of QPXD and neither in MGVR. However, there was a correlation between QPXD and MGVR for Filtek Bulk Fill One resin.


Objetivo: Avaliar o efeito do tempo de exposição e do tipo de compósito na produção de artefato radiográfico na interface dente/material restaurador. Materiais e Métodos: Em 20 incisivos bovinos hígidos foram feitos preparos cavitários e restaurações classe II utilizando resinas compostas Filtek Bulk Fill One (grupo 1) e a Filtek Z350 (grupo 2). Em seguida, os dentes foram expostos para obtenção das radiografias digitais, variando o tempo de exposição em 0,07, 0,10, 0,14, 0,20 e 0,25s. As imagens foram avaliadas para investigação da presença de artefato através da análise do número de pixels modificado (QPXD) e do valor médio de cinza nas restaurações de classe II (MGVR), utilizando o software Image J (Instituto Nacional de Saúde, Bethesda, MD, EUA). Resultados: Observou-se a presença de artefato em toda amostra avaliada, independente de tipo de material restaurador e tempo de exposição empregado. Não se observou diferença estatisticamente significativa na QPXD e nos MGVR entre as resinas utilizadas (ANOVA 2 fatores, p p>0,05). A análise do MGVR indicou que não houve diferenças estatisticamente significativas entre as resinas nem entre os tempos de exposição (p>0,05). Observou-se uma correlação entre a QPXD e o MGVR (r=0,29) para a resina Filtek Bulk Fill One. Discussão: Como significado clínico, o presente estudo revela a importância da atenção à região da interface dente-restauração por parte do Cirurgião-Dentista, o qual deve aliar os achados radiográficos diagnosticados com o auxílio de ferramentas digitais aos sinais clínicos, para compor um projeto terapêutico singular com uma real necessidade de intervenção, caso haja. Conclusão: Foi identificado a presença de pixels alterados sobre a dentina na região da interface dente-restauração em todos os corpos de prova. A variação do tempo de exposição como também o tipo do compósito restaurador não influenciou no aumento ou diminuição do QPXD e nem tão pouco no MGVR. Contudo houve correlação entre o QPXD e o MGVR para a resina Filtek Bulk Fill One.

18.
Artículo en Inglés | LILACS-Express | LILACS | ID: biblio-1528851

RESUMEN

The present study analyzed the microhardness and degree of conversion of three Bulk Fill resins (M1 - Filtek Bulk Fill; M2 - Tetric N-Ceram Bulk Fill and M3 - Opus Bulk Fill) polymerized by single peak and polywave Light-emitting Diode Curing Lights. A total 90 test specimens (n=10) were obtained using a Teflon matrix for the purpose of testing microhardness; and for degree of conversion: 135 specimens (n=5) by using a 2 x 6 cm matrix. The specimens were light polymerized using 3 light sources (L1 - Optilight Max, L2 - Bluephase, L3 - VALO). They were kept in artificial saliva om an oven at 37±1°C during the experiment. The degree of conversion was measured by FTIR 24 h after obtaining each test specimen. The microhardness readouts were performed with a microdurometer at the time intervals of 48 hours (T0), 7 days (T1), 14 days (T2) and 21 days (T3). M1L3 was found to show the highest microhardness values in T2, and M1 showed the lowest degree of conversion in the deep third with L1. It was concluded that Filtek Bulk Fill resin showed the best results in comparison with the other resins.


El presente estudio analizó la microdureza y el grado de conversión de tres resinas Bulk Fill (M1 - Filtek Bulk Fill; M2 - Tetric N-Ceram Bulk Fill y M3 - Opus Bulk Fill) polimerizadas por lámparas de curado de diodo emisor de luz de pico único y polionda. Se obtuvieron un total de 90 especímenes de prueba (n=10) utilizando una matriz de teflón con el propósito de probar la microdureza; y para grado de conversión: 135 especímenes (n=5) utilizando una matriz de 2 x 6 cm. Las muestras se fotopolimerizaron utilizando 3 fuen- tes de luz (L1 - Optilight Max, L2 - Bluephase, L3 - VALO). Se mantuvieron en saliva artificial en estufa a 37 ±1°C durante el experimento. El grado de conversión se midió por FTIR 24 h después de obtener cada muestra de prueba. Las lecturas de microdureza se realizaron con un microdurómetro en los intervalos de tiempo de 48 horas (T0), 7 días (T1), 14 días (T2) y 21 días (T3). Se encontró que M1L3 mostraba los valores más altos de microdureza en T2, y M1 mostraba el grado más bajo de conversión en el tercio profundo con L1. Se concluyó que la resina Filtek Bulk Fill mostró los mejores resultados en comparación con las demás resinas.

19.
Rev. Ciênc. Plur ; 9(3): 33414, 26 dez. 2023. ilus
Artículo en Portugués | LILACS, BBO | ID: biblio-1524471

RESUMEN

Introdução:A estética do sorriso é um aspecto valorizado pela sociedade atual, o que demanda que os profissionais de odontologia estejam atualizados sobre materiais dentários e novas técnicas para alcançar resultados estéticos restauradores de alta qualidade. A resina composta é frequentemente utilizada para simplificar a reabilitação oral, pois oferece facetas dentárias que combinam excelente estética e durabilidade. Objetivo:Este artigo tem como objetivo relatar um caso clínico de reabilitação estética utilizando facetas em resina composta com fechamento de diastemas.Relato de caso:Uma paciente do sexo feminino, com 24 anos de idade, procurou a clínica escola de odontologia com insatisfação em relação à estética do seu sorriso. A pacienteapresentava diastemas, restauração defeituosa e desproporção no tamanho dos dentes anteriores. O tratamento consistiu em um clareamento caseiro prévio, seguido pela confecção de facetas diretas em resina composta para fechamento dos diastemas e correção da desproporção dentária. Foram utilizados um Jig Estético e o software Digital Smile Design (DSD)para o planejamento, além de um mock-up em resina bisacrílica. Após a confecção das facetas, foi obtido um resultado estético final satisfatório. O caso incluiu um total de oito facetas,dos dentes 14 ao 24. Conclusão:O tratamento utilizando restaurações em resina composta proporcionou à paciente uma reabilitação estética, funcional e biológica (AU).


Introduction:Smile aesthetics is an aspect valued by today's society, which demands that dental professionals are up to date on dental materials and new techniques to achieve high-quality restorative aesthetic results. Composite resin is often used to simplify oral rehabilitation, as it offers dental veneers which combine excellent aesthetics and durability. Objective:This article aims to report a clinical case of aesthetic rehabilitation using composite resin veneers with diastema closure. Case report:A24-year-old female patient came to the dental school clinic with dissatisfaction regarding the aesthetics of her smile. The patient had diastemas, defective restoration and disproportionate anterior teeth size. The treatment consisted of prior at-home tooth bleaching, followed by creating direct composite resin veneers to close the diastemas and correct tooth disproportion. An Aesthetic Jig and the Digital Smile Design (DSD) software program were used for planning, in addition to a mock-up in bisacrylic resin. After treatment, a satisfactory final aesthetic result was obtained. The case included a total of eight veneers, from teeth 14 to 24. Conclusion:Treatment using composite resin restorations provided the patient with aesthetic, functional and biological rehabilitation (AU).


Introducción: La estética de la sonrisa es un aspecto valorado por la sociedad actual, hecho que demanda de los profesionales de odontología actualización constante sobre los materiales dentarios y nuevas técnicas para alcanzar resultados estéticos restauradores de altacualidad. La resina compuesta es frecuentemente utilizada para simplificar la rehabilitación oral, pues ofrece facetas dentarias que combinan excelente estética y durabilidad.Objetivo: Este artículo tiene como objetivo relatar un caso clínico de rehabilitación estética a partir de la utilización de facetas en resina compuesta con cierre de diastemas. Informe de caso: Una paciente, del sexo femenino, con 24 años de edad, buscó la clínica-escuela de odontología insatisfecha con la estética de su sonrisa. La paciente presentaba diastemas, restauración dentaria defectuosa y desproporción en el tamaño de los dientes anteriores. El tratamiento consistió en un blanqueamiento casero previo, seguido por la confección de facetas directas de resina compuesta para cierre de los diastemas y corrección de la desproporción dentaria. Fueron utilizados un Jig Estético y el software Digital Smile Design(DSD) para el planeamiento, además de un mock-upen resina bisacrílica. Tras la confección de las facetas, fue obtenido un resultado estético final satisfactorio. El caso incluyó un total de ocho facetas, de los dientes 14 al 24.Conclusión: El tratamiento a partir de restauraciones en resina compuesta proporcionó a la paciente una rehabilitación estética, funcional y biológica (AU).


Asunto(s)
Humanos , Femenino , Adulto , Coronas con Frente Estético , Diastema/terapia , Blanqueamiento de Dientes , Satisfacción del Paciente , Materiales Dentales/uso terapéutico , Estética Dental , Rehabilitación Bucal
20.
Rev. Odontol. Araçatuba (Impr.) ; 44(3): 21-26, set.-dez. 2023. ilus
Artículo en Portugués | LILACS, BBO | ID: biblio-1553109

RESUMEN

Os hábitos parafuncionais são caracterizados como movimentos involuntários e multifatoriais, podendo ter como principais fatores causais o estresse e a ansiedade. Essa condição acarreta, muitas vezes, na diminuição da dimensão vertical de oclusão por conta do desgaste dentário, prejudicando mastigação, fonação, estética e funções, sendo, portanto, de suma importância seu diagnóstico e tratamento. Aquele se dá através da anamnese, associado ao exame clínico e, se necessário, exames complementares. A abordagem clínico-terapêutica é ampla e multidisciplinar, devendo atuar no fator causal e suas consequências, existindo uma gama de possibilidades terapêuticas, tornando, por isso, um tratamento complexo. Por tal, o presente estudo aborda uma opção de tratamento em um relato de um caso clínico onde o paciente apresentava perda de dimensão vertical de oclusão, desgastes dentários e queixas funcionais e estéticas. A técnica se deu por meio do aumento da dimensão vertical através de Table Tops e facetas anteriores, ambas em resina composta atrelado ao aconselhamento multidisciplinar. Este trabalho mostrou a importância da realização de uma técnica reabilitadora correta, pois a sobrecarga e a perda de dimensão vertical podem gerar danos ao sistema estomatognático, prejudicando a articulação temporomandibular, ligamentos, músculos e dentes. Nesse contexto, conclui-se que é de suma importância uma avaliação minuciosa do paciente, tendo um planejamento correto do caso para um correto tratamento e um prognóstico positivo(AU)


Parafunctional habits are characterized as involuntary and multifactorial movements, and the main causal factors may be stress and anxiety. This condition often leads to a decrease in the vertical dimension of occlusion due to tooth wear, impairing chewing, phonation, aesthetics and functions, and therefore its diagnosis and treatment are of supreme importance. The former takes place through anamnesis, associated with a clinical examination and, if necessary, additional tests. The clinicaltherapeutic approach is wide and multidisciplinary and must operate on the causal factor and its consequences, with a range of therapeutic possibilities, turning it a complex treatment. Therefore, the study presents a treatment of a case report where the patient had loss of vertical dimension of occlusion, dental wear and functional and aesthetic complaints. The technique was performed by increasing the vertical dimension through Table Tops and anterior veneers, both in composite resin attached to a multidisciplinary advice. This work showed the importance of performing a correct rehabilitation technique, because the overload and loss of vertical dimension can cause damage to the stomatognathic system, harming the temporomandibular joint, ligaments, muscles and teeth. In this context, it is concluded that a thorough evaluation of the patient is very important, having a correct planning of the case for a correct treatment and a positive prognosis(AU)


Asunto(s)
Humanos , Masculino , Adulto , Dimensión Vertical , Trastornos de la Articulación Temporomandibular , Ansiedad , Estrés Psicológico , Resinas Compuestas , Coronas con Frente Estético , Desgaste de los Dientes
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA