Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Añadir filtros








Intervalo de año
1.
Korean Journal of Preventive Medicine ; : 271-283, 1988.
Artículo en Coreano | WPRIM | ID: wpr-52068

RESUMEN

A Fourier transform infrared spectrophotometric method was described for the determination of quartz, mica(sericite) and feldspar(potassium feldspar) in respirable dust in Taebaek area. The results were as follows; 1) The concentration of minerals were determined from the intensity of absorption peak of quartz at 799 cm-1, sericite at 539 cm-1, and potassium feldspar at 648 cm-1 respectively. 2) The precision(C. V. %) for the quartz determination was 7.70+/-2.68 % from 10 to 200 microgram of quartz. 3) The precision for the sericite determination was 16.34+/-6.82 % from 30 to 500 microgram of serictite. 4) The precision for the potassium feldspar determination was 5.28+/-1.74 % from 30 to 500 microgram of potassium feldspar. 5) The concentration of respirable dust in Taebaek area was 4.90+/-3.29 mg/m3(0.4-93.7%), percent quartz was 1.80+/-4.14% (0.01-20.56%), percent sericite was 11.37+/-6.43% (0.00-29.69%), percent potassium feldspar was 8.15 % (n=7, 3.41-19.70%). 6) The difference of respirable coal dust, quartz, and sericite concentration in drilling, coal cutting, hauling and separating was significant respectively (p<0.05).


Asunto(s)
Absorción , Carbón Mineral , Polvo , Análisis de Fourier , Minerales , Potasio , Cuarzo , Espectrofotometría Infrarroja
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA