Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Añadir filtros








Intervalo de año
1.
Radiol. bras ; 56(4): 171-178, 2023. tab, graf
Artículo en Inglés | LILACS-Express | LILACS | ID: biblio-1514664

RESUMEN

Abstract Objective: To evaluate the accuracy of preoperative positron emission tomography/computed tomography with 68Ga-labeled prostate-specific membrane antigen (68Ga-PSMA PET/CT) for staging prostate cancer and compare it with magnetic resonance imaging (MRI) using histopathology of surgical specimens as the gold standard. Materials and Methods: In this retrospective study, 65 patients with prostate cancer were analyzed. Results: The accuracy of 68Ga-PSMA PET/CT for tumor detection was 95%, and that of MRI was 91%. There was no difference between 68Ga-PSMA PET/CT and MRI regarding localization of the lesion. The sensitivity of 68Ga-PSMA PET/CT for detecting extraprostatic extension was quite low (14%). For detection of seminal vesicle invasion, 68Ga-PSMA PET/CT showed a sensitivity of 57% and accuracy of 91%. There was a moderate correlation between the maximum standardized uptake value (SUVmax) and the serum level of prostate-specific antigen (p < 0.01; ρ = 0.368) and between the SUVmax and the International Society of Urological Pathology (ISUP) grade (p < 0.01; ρ = 0.513). Conclusion: 68Ga-PSMA PET/CT is a promising tool for detecting and evaluating the primary tumor, which can alter the staging and management of the disease.


Resumo Objetivo: Avaliar a acurácia da tomografia por emissão de pósitrons/tomografia computadorizada com PSMA (PET-PMSA) pré-operatória para estadiamento do câncer de próstata e compará-la com a ressonância magnética (RM) utilizando o histopatológico cirúrgico como padrão ouro. Materiais e Métodos: Neste estudo retrospectivo foram analisados 65 pacientes com câncer de próstata. Resultados: A acurácia da PET-PSMA para a detecção tumoral foi de 95% e a da RM foi de 91%. Não houve diferença entre a PET-PSMA e a RM quanto à localização da lesão. A PET-PSMA apresentou baixa sensibilidade (14%) para detecção de extensão extraprostática em comparação ao histopatológico. Para detecção de invasão de vesícula seminal, a PET-PSMA apresentou sensibilidade de 57% e acurácia de 91% em comparação ao histopatológico. Houve correlação moderada entre o SUVmax e o PSA (p < 0,01; ρ = 0,368) e entre o SUVmax e o ISUP (p < 0,01; ρ = 0,513). Conclusão: A PET-PSMA é uma ferramenta promissora para detecção e avaliação do tumor primário, alterando o estadiamento e a conduta do paciente.

2.
Radiol. bras ; 55(4): 216-224, Aug. 2022. tab, graf
Artículo en Inglés | LILACS-Express | LILACS | ID: biblio-1394568

RESUMEN

Abstract Objective: To promote advanced research using magnetic resonance imaging (MRI) in the diagnosis of and screening for osteoporosis by looking for correlations among the T-scores measured by dual-energy X-ray absorptiometry (DEXA), the apparent diffusion coefficient (ADC) values on diffusion-weighted imaging (DWI), and the T1-weighted signal intensity values. Materials and Methods: This was a prospective study of postmenopausal women with no contraindications to MRI and no history of cancer who underwent DEXA within 30 days before or after the MRI examination. A 3.0-T scanner was used in order to acquire sagittal sequences targeting the lumbar spine. Results: Thirteen women underwent DEXA and MRI. In two cases, the MRI was discontinued early. Therefore, the final sample comprised 11 patients. The ADC values and T1-weighted signal intensity were found to be higher in patients with osteoporosis. However, among the patients > 60 years of age with osteoporosis, ADC values were lower and T1-weighted signal intensity was even higher. Conclusion: It is unlikely that MRI will soon replace DEXA for the diagnostic workup of osteoporosis. Although DWI and ADC mapping are useful for understanding the pathophysiology of osteoporosis, we believe that T1-weighted sequences are more sensitive than is DWI as a means of performing a qualitative analysis of vertebral alterations.


Resumo Objetivo: Promover pesquisas avançadas usando ressonância magnética (RM) no diagnóstico e rastreamento de osteoporose, procurando correlações entre os escores T medidos por absorciometria de raios-X de dupla energia (DEXA), valores de coeficiente de difusão aparente (ADC) na difusão e valores de intensidade de sinal ponderado em T1. Materiais e Métodos: Estudo prospectivo de mulheres na pós-menopausa sem contraindicações para RM e sem histórico de câncer que foram submetidas a DEXA 30 dias antes ou após o exame de RM. Um scanner 3.0-T foi utilizado para adquirir sequências sagitais direcionadas à coluna lombar. Resultados: Treze mulheres foram submetidas a DEXA e RM. Em dois casos, a RM foi interrompida precocemente. Portanto, a amostra final foi composta por 11 pacientes. Os valores de ADC e intensidade de sinal ponderado em T1 foram mais elevados nas pacientes com osteoporose. No entanto, no subgrupo de pacientes > 60 anos de idade com osteoporose, os valores de ADC foram menores e a intensidade do sinal ponderado em T1 foi ainda maior. Conclusão: É improvável que a RM substitua DEXA para a investigação diagnóstica da osteoporose no futuro próximo. Embora a difusão e o mapeamento ADC sejam úteis para a compreensão da fisiopatologia da osteoporose, acreditamos que as sequências ponderadas em T1 são mais sensíveis do que a difusão como meio de realizar uma análise qualitativa das alterações vertebrais.

3.
Einstein (Säo Paulo) ; 17(3): eAO4615, 2019. tab, graf
Artículo en Inglés | LILACS | ID: biblio-1011995

RESUMEN

ABSTRACT Objective: To compare qualitatively and quantitatively, in terms of image quality, a new biexponential diffusion sequence protocol with the standard monoexponential diffusion protocol on multiparametric prostate magnetic resonance imaging. Methods: This study had a prospective data collection and cross-sectional analysis. Between August and November 2017, a total of 70 patients who underwent multiparametric prostate magnetic resonance imaging due to clinical suspicion of prostatic neoplasia were recruited. The images obtained were evaluated by two independent readers regarding subjective/qualitative criteria (six criteria) and objective/quantitative criteria (three criteria), always comparing the monoexponential to biexponential acquisition protocols. The results were compared by statistical analysis (interobserver agreement − Gwet coefficient; analysis of the qualitative variables − Stuart-Maxwell test; and analysis of the quantitative variables − Wilcoxon test). Results: After exclusion of four patients, the final sample consisted of 66 patients. A good/excellent inter observer agreement was stablished for subjective criteria (except in one criteria). For the qualitative analysis the amount of good or excellent evaluations was higher for the monoexponential protocol (except in one category), with evidence of significant differences for three criteria (diffusion weighted imaging global quality; diffusion weighted imaging signal-to-noise ratio; and apparent diffusion coefficient signal-to-noise ratio). For the quantitative data analysis, the monoexponential protocol showed less variability of the anteroposterior diameters, meaning less distortion of the images, and better estimated signal-to-noise ratio. Conclusion: In our data, the quality of the images of the monoexponential standard diffusion sequence was qualitatively and quantitatively superior to those of the biexponential diffusion weighted imaging sequence.


RESUMO Objetivo: Comparar qualitativa e quantitativamente, em termos de qualidade de imagem, um novo protocolo de sequência de difusão biexponencial com o protocolo de difusão monoexponencial padrão, em ressonância magnética multiparamétrica da próstata. Métodos: Estudo com coleta prospectiva e análise transversal. Entre agosto e novembro de 2017, foram recrutados 70 pacientes que realizaram ressonância magnética multiparamétrica da próstata, por suspeita de neoplasia prostática. As imagens obtidas por ambas as sequências foram avaliadas por dois leitores independentes, quanto a critérios de avaliação subjetiva/qualitativa (seis critérios) e objetiva/quantitativa (três critérios), sempre comparando os protocolos de aquisição monoexponencial e biexponencial. Os resultados foram comparados por análise estatística (concordância interobservador − coeficiente de Gwet; análise das variáveis qualitativas − teste de Stuart-Maxwell; e análise das variáveis quantitativas − testes de Wilcoxon). Resultados: Após exclusão de quatro pacientes, a amostra final foi composta por 66 pacientes. Uma boa/excelente concordância interobservador foi estabelecida para critérios subjetivos (exceto em um critério). Para a análise qualitativa, a quantidade de avaliações boas ou excelentes foi maior para o protocolo monoexponencial (exceto em uma categoria), com evidências de diferenças significativas para três critérios (qualidade global da imagem ponderada em difusão, relação sinal-ruído na imagem ponderada em difusão e relação sinal-ruído ADC). Para a análise quantitativa dos dados, o protocolo monoexponencial apresentou menor variabilidade dos diâmetros anteroposteriores, o que significou menos distorção das imagens, e melhor relação sinal-ruído estimada. Conclusão: Em nossos dados, a qualidade das imagens da sequência de difusão padrão monoexponencial foi qualitativa e quantitativamente superior àquelas da sequência teste biexponencial.


Asunto(s)
Humanos , Masculino , Neoplasias de la Próstata/diagnóstico por imagen , Imagen de Difusión por Resonancia Magnética/métodos , Imagen de Difusión por Resonancia Magnética/normas , Estándares de Referencia , Variaciones Dependientes del Observador , Estudios Transversales , Estudios Prospectivos , Reproducibilidad de los Resultados , Estadísticas no Paramétricas , Relación Señal-Ruido
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA