Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Añadir filtros








Intervalo de año
1.
Anatomy & Cell Biology ; : 93-97, 2018.
Artículo en Inglés | WPRIM | ID: wpr-715228

RESUMEN

Several authors have made efforts to define the position of the axillary nerve within deltoid muscle and to calculate the so called safe area for this nerve but it still remains a matter of debate. The primary aim of the study was to investigate the acromio-axillary (AA) distance and its correlation with upper arm length. The secondary aim was to re-define the safe area for axillary nerve within deltoid muscle. Sixty shoulders of thirty adult human cadavers were dissected using standard methods. The distance from the anterior and posterior edge of acromion to the upper border of the course of the axillary nerve was measured and recorded as anterior and posterior AA distance respectively. Correlation analysis was done between the upper arm length and AA distance for each limb. The ratios between anterior and posterior AA distance and upper arm length were calculated and mentioned as anterior index and posterior index, respectively. The mean of anterior and posterior AA distance was 5.22 cm and 4.17 cm, respectively. The mean of upper arm length was 29.30 cm. The means of anterior index and posterior indices were 0.18 and 0.14, respectively. There was a significant correlation between upper arm length and both the anterior and posterior AA distance. The axillary nerve was found to lie at variable distance from the acromion. The minimum AA distance was found to be 3.50 cm. So this should be considered as the maximum permissible length of the deltoid split. Upper arm length has strong correlation with both anterior and posterior AA distances. The ideal safe area for the axillary nerve was found to be a quadrangular area above it and the size of which depends on the length of the upper arm.


Asunto(s)
Adulto , Humanos , Acromion , Brazo , Cadáver , Músculo Deltoides , Extremidades , Hombro
2.
Journal of Pharmaceutical Analysis ; (6): 139-141, 2006.
Artículo en Chino | WPRIM | ID: wpr-621753

RESUMEN

The study was to investigate thrombolysis in vitro with ultrasound, and to discuss effects of thrombolysis with ultrasound on the structure of erythrocyte and its safety threshold under different ultrasound intensity and exposure time. The structure of erythrocyte in thrombus was evaluated under light microscope. The relationship between the structure of erythrocyte in thrombus and ultrasound intensity and exposure time was obtained. The results showed that ultrasound eliminated the thrombus. According to the change of the structure of erythrocyte in thrombus and ultrasound intensity and exposure time, the effects of thrombolysis with ultrasound could be divided into three kinds of areas: the A, B, C area. The area A was the safe area, the area B was the relatively safe area, and the area C was the irreversible damage area. The study suggested that ultrasound intensity and exposure time had significant impact on the structure of erythrocyte. Stronger ultrasound intensity or longer exposure time could cause erythrocytes irreversible damage. It could accelerate thrombolysis and shorten the exposure time that the ultrasound intensity was little bit increased. The study of effects of thrombolysis with ultrasound on the structure of erythrocyte and its safety threshold were important for practical applications.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA