Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 1.341
Filtrar
1.
China Journal of Orthopaedics and Traumatology ; (12): 81-85, 2024.
Artículo en Chino | WPRIM | ID: wpr-1009227

RESUMEN

OBJECTIVE@#To investigate the feasibility of mimics software in analyzing a new type of complex anterior cervical fixation -- anterior transpedicular screw fixation+zero notch internal fixation.@*METHODS@#From January 2021 to September 2022, 50 normal pedestrians who underwent cervical spine CT scanning were selected for C1-C7 segment scanning, including 27 males and 23 females, aged from 25 to 65 years old with an average of (46.0 ± 9.0) years old. The dicom format is exported and engraved into the CD, and use the mimics software to perform 3D reconstruction of each segment. A simulated screw is placed on the image according to the critical value of zero notch screw (head and tail angle 44°, internal angle 29°). The position of zero notch screw in each segment is observed to determine the feasibility of anterior transpedicular screw fixation plus zero notch internal fixation.@*RESULTS@#For the upper zero notch screws the three-dimensional images of the cervical spine across all 50 subjects within the C3-C7 segments demonstrated safe position, with no instances of intersection with ATPS. For the lower zero notch screw, in C3-C4 and C4-C5, 4 out of 50 subjects are in the safe position in the three-dimensional images of cervical vertebrae, and 46 cases could achieve secure screw placement when the maximum caudal angle is(32.3±1.9) ° and (36.1±2.2) °, respectively. In C5-C6 and C6-C7 segments, no lower zero notch screws intersected with ATPS, and all screws are in safe positions.@*CONCLUSION@#Lower cervical anterior pedicle screw fixation plus zero notch internal fixation can achieve successful nail placement through the selected entry point and position.


Asunto(s)
Masculino , Femenino , Humanos , Adulto , Persona de Mediana Edad , Anciano , Estudios de Factibilidad , Tomografía Computarizada por Rayos X/métodos , Tornillos Pediculares , Fijación Interna de Fracturas , Vértebras Cervicales/cirugía , Programas Informáticos
2.
China Journal of Orthopaedics and Traumatology ; (12): 57-60, 2024.
Artículo en Chino | WPRIM | ID: wpr-1009223

RESUMEN

OBJECTIVE@#To compare the biomechanical stability of three cross-bridge headless compression screws and locking plates in the fixation of Mason type Ⅲ radial head fractures by finite element method.@*METHODS@#Using reverse modeling technology, the radial CT data and internal fixation data of a healthy 25-year-old male were imported into the relevant software. Three-dimensional finite element model of 3 cross-bridge headless compression screws and locking plates for MasonⅢ radial head fractures were established, and the radial head was loaded with 100 N axial loading. The maximum displacement, maximum Von Mises stress and stress distribution of the two groups were compared.@*RESULTS@#The maximum displacements of the three cross-bridge screws group and locking plate group were 0.069 mm and 0.087 mm respectively, and the Von Mises stress peaks were 18.59 MPa and 31.85 MPa respectively. The stress distribution of the three screws group was more uniform.@*CONCLUSION@#Both internal fixation methods can provide good fixation effect. CoMPared with the locking plate fixation method, the 3 cross-bridge headless compression screws fixation is more stable and the stress distribution is more uniform.


Asunto(s)
Masculino , Humanos , Adulto , Análisis de Elementos Finitos , Fracturas Radiales de Cabeza y Cuello , Tornillos Óseos , Fenómenos Biomecánicos , Fracturas del Radio/cirugía , Fijación Interna de Fracturas/métodos , Placas Óseas , Fracturas Conminutas
3.
Chinese Journal of Reparative and Reconstructive Surgery ; (12): 35-39, 2024.
Artículo en Chino | WPRIM | ID: wpr-1009105

RESUMEN

OBJECTIVE@#To assess the effectiveness of the single Kocher-Langenbeck approach combined with anterograde channel screw technique for the treatment of acetabular transverse and posterior wall fractures.@*METHODS@#Between March 2020 and October 2022, 17 cases of acetabular transverse and posterior wall fractures were treated with the single Kocher-Langenbeck approach combined with anterograde channel screw technique. There were 11 males and 6 females, with an average age of 53.6 years (range, 42-64 years). Causes of injury included traffic accident in 12 cases, and falling from height in 5 cases. The time from injury to operation ranged from 4 to 16 days with an average of 8.8 days. The operation time, intraoperative blood loss, and fluoroscopy frequency were recorded; X-ray films were reviewed regularly after operation to observe the fracture healing, and postoperative complications were recorded. At last follow-up, Matta score was used to evaluate the reduction of fracture, Harris score and modified Merle D'Aubigné-Postel scores system were used to evaluate the hip joint function.@*RESULTS@#The operation time was 150-230 minutes (mean, 185.9 minutes), the intraoperative blood loss was 385-520 mL (mean, 446.2 mL), and the fluoroscopy frequency was 18-34 times (mean, 27.5 times). Postoperative fat liquefaction occurred in 1 case and the other incisions healed by first intention; 3 cases had limb numbness after operation, and the symptoms disappeared after active symptomatic treatment; no urogenital system and intestinal injury occurred. All patients were followed up 12-28 months (mean, 19.9 months). Bone union was achieved in all cases with an average healing time of 10.8 weeks (range, 8-14 weeks). There was no complication such as loosening and breakage of internal fixators. At last follow-up, according to Matta score, 12 cases achieved anatomic reduction, 3 satisfactory reduction, and 2 fair reduction, the satisfactory rate was 88.2%; according to Harris hip function score, 12 cases were excellent, 3 good, and 2 fair, the excellent and good rate was 88.2%; according to the modified Merle D'Aubign Aubigné-Postel scoring system, the results were excellent in 11 cases, good in 3 cases, and fair in 3 cases, with an excellent and good rate of 82.4%.@*CONCLUSION@#The single Kocher-Langenbeck approach combined with anterograde channel screw technique is a minimally invasive method for the treatment of acetabular transverse and posterior wall fractures with less complications, simple operation, and satisfactory effectiveness.


Asunto(s)
Masculino , Femenino , Humanos , Persona de Mediana Edad , Pérdida de Sangre Quirúrgica , Fijación Interna de Fracturas/métodos , Resultado del Tratamiento , Fracturas Óseas/cirugía , Acetábulo/lesiones , Tornillos Óseos , Fracturas de Cadera/cirugía , Estudios Retrospectivos
4.
Chinese Journal of Reparative and Reconstructive Surgery ; (12): 28-34, 2024.
Artículo en Chino | WPRIM | ID: wpr-1009104

RESUMEN

OBJECTIVE@#To compare the effectiveness of O-arm navigation and C-arm navigation for guiding percutaneous long sacroiliac screws in treatment of Denis type Ⅱ sacral fractures.@*METHODS@#A retrospective study was conducted on clinical data of the 46 patients with Denis type Ⅱ sacral fractures between April 2021 and October 2022. Among them, 19 patients underwent O-arm navigation assisted percutaneous long sacroiliac screw fixation (O-arm navigation group), and 27 patients underwent C-arm navigation assisted percutaneous long sacroiliac screw fixation (C-arm navigation group). There was no significant difference in gender, age, causes of injuries, Tile classification of pelvic fractures, combined injury, the interval from injury to operation between the two groups ( P>0.05). The intraoperative preparation time, the placement time of each screw, the fluoroscopy time of each screw during placement, screw position accuracy, the quality of fracture reduction, and fracture healing time were recorded and compared, postoperative complications were observed. Pelvic function was evaluated by Majeed score at last follow-up.@*RESULTS@#All operations were completed successfully, and all incisions healed by first intention. Compared to the C-arm navigation group, the O-arm navigation group had shorter intraoperative preparation time, placement time of each screw, and fluoroscopy time, with significant differences ( P<0.05). There was no significant difference in screw position accuracy and the quality of fracture reduction ( P>0.05). There was no nerve or vascular injury during screw placed in the two groups. All patients in both groups were followed up, with the follow-up time of 6-21 months (mean, 12.0 months). Imaging re-examination showed that both groups achieved bony healing, and there was no significant difference in fracture healing time between the two groups ( P>0.05). During follow-up, there was no postoperative complications, such as screw loosening and breaking or loss of fracture reduction. At last follow-up, there was no significant difference in pelvic function between the two groups ( P>0.05).@*CONCLUSION@#Compared with the C-arm navigation, the O-arm navigation assisted percutaneous long sacroiliac screws for the treatment of Denis typeⅡsacral fractures can significantly shorten the intraoperative preparation time, screw placement time, and fluoroscopy time, improve the accuracy of screw placement, and obtain clearer navigation images.


Asunto(s)
Humanos , Fijación Interna de Fracturas/métodos , Estudios Retrospectivos , Imagenología Tridimensional , Tornillos Óseos , Cirugía Asistida por Computador , Tomografía Computarizada por Rayos X , Fracturas de la Columna Vertebral/cirugía , Fracturas Óseas/cirugía , Huesos Pélvicos/lesiones , Complicaciones Posoperatorias , Traumatismos del Cuello
5.
Int. j. morphol ; 41(1): 111-117, feb. 2023. ilus, tab
Artículo en Inglés | LILACS | ID: biblio-1430506

RESUMEN

SUMMARY: Anatomical variation of the foramina transversaria (FT) is associated with vertebral neurovascular symptoms and can cause complications after lower spine surgery, especially cervical pedicle screw (CPS) insertion. FT variation has been documented and classified in various populations, as this information can help increase cervical stability in subaxial vertebral surgery. Although the morphometry of the upper cervical spine in Thai populations has been reported, there have yet been no studies examining the features of FT. The FT of dried cervical spines (C3-C7; left and right side; n = 107, male = 53 and female = 54) were examined for morphological variation, and their anteroposterior (AP) and transverse (T) diameters were measured using a digital vernier caliper. Morphometric data and variations were compared by sex and lateral side. It was that the C3-C6 FT in both sexes were round, and the C7 FT was elliptical with an oblique right side. FT diameters did not differ significantly by sex except for the AP diameters of C6-C7 and for T diameters of C4 and C7. The left AP diameters of C3-C6 were significantly longer than the right, as were the T diameters of C4 and C7 FT. Additionally, T diameter was significantly longer than that of the AP, except that of the left C6 in male spines, which did not differ from the AP. Most FT examined were round. These findings should be considered in the provisional diagnosis of vertebral neurovascular symptoms caused by FT variation as well as that of neurovascular damage after cervical pedicle screw placement.


La variación anatómica del foramen transverso (FT) se asocia con síntomas neurovasculares vertebrales y puede causar complicaciones después de la cirugía de columna cervical inferior, especialmente la inserción de tornillos pediculares cervicales (TPC). La variación del FT se ha documentado y clasificado en varias poblaciones, ya que esta información puede ayudar a aumentar la estabilidad cervical en la cirugía vertebral subaxial. Aunque se ha informado sobre la morfometría de la columna cervical superior en poblaciones tailandesas, aún no se han realizado estudios que examinen las características de FT. Se examinó la variación morfológica del FT de vértebras cervicales secas (C3-C7; lado izquierdo y derecho; n = 107, hombres = 53 y mujeres = 54), y se midieron sus diámetros anteroposterior (AP) y transverso (T) usando un pie de metro digital. Se compararon datos morfométricos y variaciones por sexo y lado. Los FT de C3-a C6 en ambos sexos eran redondos, y el FT C7 era elíptico con el lado derecho oblicuo. Los diámetros del FT no difirieron significativamente por sexo excepto para los diámetros AP de C6- C7 y para los diámetros transversos de C4 y C7. Los diámetros AP izquierdos de C3-C6 eran significativamente más largos que los del lado derecho, al igual que los diámetros transversos de C4 y C7. Además, el diámetro transverso fue significativamente mayor que el AP, excepto el C6 izquierdo en las vértebras de hombres, que no difirió del AP. La mayoría de los FT examinados eran redondos. Estos hallazgos deben ser considerados en el diagnóstico provisional de síntomas neurovasculares vertebrales causados por la variación del FT, así como en el de daño neurovascular tras la colocación de tornillos pediculares cervicales.


Asunto(s)
Humanos , Masculino , Femenino , Vértebras Cervicales/anatomía & histología , Variación Anatómica , Tailandia , Caracteres Sexuales
6.
Chinese Journal of Orthopaedic Trauma ; (12): 427-432, 2023.
Artículo en Chino | WPRIM | ID: wpr-992729

RESUMEN

Objective:To investigate the effect of the use of medial calcar screws on the treatment of Neer type Ⅲ proximal humeral fracture with Multiloc intramedullary nailing.Methods:A retrospective study was conducted to analyze the data of 36 patients with Near type Ⅲ fracture of the proximal humerus who had received Multiloc intramedullary nailing at Department of Upper Limbs, Sichuan Orthopedic Hospital from January 2016 to December 2021. There were 6 males and 30 females with an age of (63.9±5.3) years. They were divided into 2 groups according to whether medial calcar screws had been used or not. There were 17 cases in the group without medial calcar screws and 19 cases in the group with medial calcar screws. The 2 groups were compared in terms of flexion and lifting, external rotation, internal rotation and back touch, visual analogue scale (VAS), American Shoulder and Elbow Surgeons (ASES) score, Constant-Murley score for shoulder function (Constant score), neck shaft angle, and incidence of complications at the last follow-up.Results:There were no statistically significant significances in the preoperative general data between the 2 groups, indicating comparability between the groups ( P>0.05). The 36 patients were followed up for 13.5(12.0,19.8) months after surgery. The flexion and lifting, external rotation, internal rotation and back touch, VAS, ASES score, Constant score, neck shaft angle at the last follow-up in the group without medial calcar screws were, respectively, 134.1°±8.4°, 32.1°±5.3°, 14.0 (13.0, 15.5) , 0.0 (0.0, 1.0), 78.2±5.2, 78.0±5.8, and 137.6°±8.1°, insignificantly different from those in the group with medial calcar screws [134.7°±6.1°, 35.0(30.0, 35.0)°, 14.0(13.0, 15.0), 1.0 (0.0, 1.0), 78.2±5.4, 76.7±4.5, and 136.9°±6.4°] ( P>0.05). Postoperative complications occurred in 6 patients in each group, showing no statistically significant difference between the 2 groups ( P=1.000). Conclusion:The use of medial calcar screws has no significant impact on the postoperative shoulder function and incidence of complications in the treatment of Neer type Ⅲ fractures of the proximal humerus with Multiloc intramedullary nailing.

7.
Chinese Journal of Orthopaedic Trauma ; (12): 37-42, 2023.
Artículo en Chino | WPRIM | ID: wpr-992678

RESUMEN

Objective:To evaluate the feasibility of using cortical bone trajectory (CBT) screws in the osteoporotic thoracolumbar fixation by comparing the bone CT values at the bone-screw interface between traditional trajectory (TT) screws and CBT screws in patients with different bone densities.Methods:The high-resolution CT imaging data of thoracolumbar segments following thoracic or lumbar spine fractures from April 2020 to October 2022 were collected at The Second Hospital Affiliated to Wenzhou Medical University for retrospective analysis. They were divided into 3 groups: a normal bone mass group, an osteopenia group and an osteoporosis group. From each group 30 cases were chosen (90 cases in total, 36 males and 54 females). All the data were imported into Mimics 18.0 for three-dimensional bone reconstruction in which placement of TT and CBT screws was simulated on the vertebrae from T10 to L2 (non-fractured vertebrae). Regions of interest (ROI) where each simulated screw intersected the bone were segmented to measure their CT bone values. For each vertebra in each group, the relative difference percentage in average CT value of ROI between TT and CBT screws was calculated. The CT values of ROI were compared in the same group between TT and CBT screws from T10 to L2; the CT values of ROI were compared in the same screws among the 3 groups from T10 to L2; the CT values of ROI were compared between the CBT screws in the osteopenia and osteoporosis groups and the TT screws in the normal bone mass group; the relative difference percentages in average CT value of ROI between CBT and TT screws were compared between the 3 groups from T10 to L2.Results:The average CT value of ROI for CBT screws was significantly higher than that for TT screws from T10 to L2 in every group ( P< 0.001); as for the CT values of ROI for CBT and TT screws from T10 to L2, the osteoporosis group<the osteopenia group<the normal bone mass group ( P<0.001); from T10 to L2, the CT value of ROI for CBT screws in the osteopenia group was significantly higher than that for TT screws in the normal bone mass group ( P<0.001); the CT value of ROI for CBT screws in the osteoporosis group was not significantly different from that for TT screws in the normal bone mass group ( P>0.05). At T10, T12, and L1, the relative difference percentage in average CT value of ROI between CBT and TT screws was significantly higher in the osteopenia and osteoporosis groups than that in the normal bone mass group ( P<0.05), but there was no such a difference between the osteopenia and the osteoporosis groups ( P>0.05). At T11 and L2, there was no significant difference between the 3 groups in the relative difference percentage in average CT value of ROI between CBT and TT screws ( P>0.05). Conclusions:As bone mass decreases, both CBT and TT screws lead to a significant decrease in the bone density at the bone-screw interface. In patients with osteoporosis, CBT screws can still lead to a higher bone density at the bone-screw interface than TT screws, thus providing a higher strength at the bone-screw interface.

8.
Chinese Journal of Trauma ; (12): 341-348, 2023.
Artículo en Chino | WPRIM | ID: wpr-992607

RESUMEN

Objective:To compare the effect of O-arm assisted and free-hand pedicle screw placement in the treatment of AO type C thoracolumbar fracture.Methods:A retrospective cohort study was used to analyze the clinical data of 34 patients with type C thoracolumbar fracture admitted to Henan Provincial People′s Hospital from January 2018 to June 2021, including 23 males and 11 females; aged 42-63 years [(50.4±7.4)years]. The fracture was located at T 11 in 4 patients, T 12 in 10, L 1 in 12, L 2 in 6, T 11~12/L 1 in 1 and T 12/L 1 in 1. Posterior reduction and internal fixation was carried out for all patients, of whom 18 were treated with O-arm assisted pedicle screw placement (navigation group) and 16 with free-hand pedicle screw placement (free-hand group). The operation time, single screw placement time, intraoperative bleeding volume, operation mode and screw placement accuracy were compared between the two groups. The kyphotic Cobb angle, visual analogue score (VAS) and American Spinal Injury Association (ASIA) score were compared between the two groups before operation, at 1 week after operation, at 3 months after operation and at the last follow-up. Postoperative complications were observed. Results:All patients were followed up for 12-29 months [(16.8±6.1)months]. There was no significant difference between the two groups in the operation time, intraoperative bleeding volume and operation mode (all P>0.05). The single screw placement time was (9.4±1.6)minutes in navigation group, but was (10.8±1.5)minutes in free-hand group ( P<0.05). The screw placement accuracy was 97.4% in navigation group, but was 81.5% in free-hand group ( P<0.01). The kyphotic Cobb angle and VAS had no significant differences between the two groups before operation (all P>0.05). The kyphotic Cobb angle in navigation group and free-hand group was (4.3±1.1)° and (5.9±1.1)° at 1 week after operation, (4.4±1.2)° and (5.7±1.3)° at 3 months after operation, and (4.4±1.2)° and (6.8±0.9)° at the last follow-up, decreased significantly from that before operation [(21.8±3.1)°, (22.2±3.2)°] (all P<0.01). The kyphotic Cobb angle in navigation group was significantly lower than that in free-hand group at 1 week, 3 months after operation and at the last follow-up (all P<0.01). The VAS in navigation group and free-hand group was (3.2±0.7)points and (4.1±0.7)points at 1 week after operation, (2.4±0.6)points and (3.0±0.8)points at 3 months after operation, and (1.8±0.9)points and (2.6±0.7)points at the last follow-up, decreased significantly from that before operation [(8.4±0.8)points, (8.3±0.9)points] (all P<0.01). The VAS in navigation group was significantly lower than that in free-hand group at 1 week, 3 months after operation and at the last follow-up (all P<0.01). The ASIA score showed no significant difference within and between the two groups before operation, at 1 week, 3 months after operation and at the last follow-up (all P>0.05). Postoperative incision infection occurred in 1 patient in both groups ( P>0.05). Implant failure such as loosening or displacement was not observed in navigation group, and only occurred in 2 patients in free-hand group ( P>0.05). Conclusion:Compared with free-hand pedicle screw placement, O-arm assisted pedicle screw placement in the treatment of AO type C thoracolumbar fracture has advantages of rapid and accurate screw placement, good reduction and notable pain relief.

9.
China Journal of Orthopaedics and Traumatology ; (12): 1058-1064, 2023.
Artículo en Chino | WPRIM | ID: wpr-1009185

RESUMEN

OBJECTIVE@#To evaluate the feasibility of S2 alar iliac screw insertion in Chinese children using computerized three-dimension reconstruction and simulated screw placement technique, and to optimize the measurement of screw parameters.@*METHODS@#A total of 83 pelvic CT data of children who underwent pelvic CT scan December 2018 to December 2020 were retrospectively analyzed, excluding fractures, deformities, and tumors. There were 44 boys and 39 girls, with an average age of (10.66±3.52) years, and were divided into 4 groups based on age (group A:5 to 7 years old;group B:8 to 10 years old;group C:11-13 years old;group D:14 to 16 years old). The original CT data obtained were imported into Mimics software, and the bony structure of the pelvis was reconstructed, and the maximum and minimum cranial angles of the screws were simulated in the three-dimensional view with the placement of 6.5 mm diameter S2 alar iliac screws. Subsequently, the coronal angle, sagittal angle, transverse angle, total length of the screw, length of the screw in the sacrum, width of the iliac, and distance of the entry point from the skin were measured in 3-Matic software at the maximum and minimum head tilt angles, respectively. The differences among the screw parameters of S2 alar iliac screws in children of different ages and the differences between gender and side were compared and analyzed.@*RESULTS@#In all 83 children, 6.5 mm diameter S2 iliac screws could be placed. There was no significant difference between the side of each screw placement parameter. The 5 to 7 years old children had a significantly smaller screw coronal angle than other age groups, but in the screw sagittal angle, the difference was more mixed. The 5 to 7 years old children could obtain a larger angle at the maximum head tilt angle of the screw, but at the minimum cranial angle, the larger angle was obtained in the age group of 11 to 13 years old. There were no significant differences among the age groups. The coronal angle and sagittal angle under maximum cephalic angle and minimum cranial angle of 5 to 7 years old male were (40.91±2.91)° and (51.85±3.75)° respectively, which were significantly greater than in female. The coronal angle under minimum cranial angle was significantly greater in girls aged 8-10 years old than in boys. For the remaining screw placement angle parameters, there were no significant differences between gender. The differences in the minimum iliac width, the screw length, and the length of the sacral screws showed an increasing trend with age in all age groups. The distance from the screw entry point to the skin in boys were significantly smaller than that of girls. The minimum width of the iliac in boys at 14 to 16 years of age were significantly wider than that in girls at the same stage. In contrast, in girls aged 5 to 7 years and 11 to 13 years, the screw length was significantly longer than that of boys at the same stage.@*CONCLUSION@#The pelvis of children aged 5 to 16 years can safely accommodate the placement of 6.5 mm diameter S2 alar iliac screws, but the bony structures of the pelvis are developing and growing in children, precise assessment is needed to plan a reasonable screw trajectory and select the appropriate screw length.


Asunto(s)
Humanos , Masculino , Femenino , Niño , Adolescente , Preescolar , Ilion/cirugía , Estudios Retrospectivos , Estudios de Factibilidad , Tornillos Óseos , Pelvis , Sacro/cirugía , Fusión Vertebral/métodos
10.
China Journal of Orthopaedics and Traumatology ; (12): 936-942, 2023.
Artículo en Chino | WPRIM | ID: wpr-1009164

RESUMEN

OBJECTIVE@#To investigate the clinical efficacy of percutaneous screw fixation combined with minimally invasive transpedicular bone grafting and non-bone grafting in the treatment of thoracolumbar fractures.@*METHODS@#From Janury 2021 to June 2022, 40 patients with thoracolumbar fracture were divided into the experimental group and the control group. There were 26 patients in the experimental group, including 21 males and 5 females with an aberage age of (47.3±12.3) years old, who underwent percutaneous pedicle screw fixation combined with transpedicular autogenous bone grafting. In the control group, 14 patients received percutaneous pedicle screw fixation only. including 7 makes and 7 females with an average age of (50.2±11.2) years old. The operative time, intraoperative blood loss, anterior height ratio of injured vertebrae, Cobb angle, visual analogue score (VAS), MacNab scores, loosening or broken of the implants. were compared and analyzed.@*RESULTS@#There was no significant difference in operation time, intraoperative blood loss, VAS and anterior height ratio of injured vertebrae between the two groups. Compared with the preoperative results, VAS and anterior height ratio of injured vertebrae were improved statistically(P<0.05). For Cobb angle of injured vertebra, there was no significant difference between the two groups before surgery (P=0.766). While at 1 week, 3 months and 12 months after surgery, there were statistically differences between the two groups (P values were 0.042, 0.007 and 0.039, respectively). The Cobb angle of injured vertebrae one year after operation was statistically decreased in both groups compared with that before surgery (P<0.001). One year after surgery, the excellent and good rate of Macnab scores was 96.15% in the experimental group and 92.86% in the control group, and there was no statistical differences between the two groups (P=0.648). There was one patient in the control group suffering superficial wound infection on the third day, which was cured by dressing change and anti-infection treatment. There were no postoperative screw loosening and broken in both groups.@*CONCLUSION@#The two surgical methods have the advantages of less trauma, less pain and quicker recovery, which can restore the height of the injured vertebra, reconstruct the spinal sequence and reduce the fracture of the vertebral body. Transpedicular autogenous bone grafting can increase the stability of the fractured vertebra and maintain the height of the vertebra better after surgery, thus reducing the possibility of complications such as kyphosis, screw loosening and broken.


Asunto(s)
Masculino , Femenino , Humanos , Adulto , Persona de Mediana Edad , Tornillos Pediculares , Trasplante Óseo , Pérdida de Sangre Quirúrgica , Vértebras Lumbares/lesiones , Vértebras Torácicas/lesiones , Fijación Interna de Fracturas/métodos , Fracturas de la Columna Vertebral/cirugía , Resultado del Tratamiento , Estudios Retrospectivos
11.
China Journal of Orthopaedics and Traumatology ; (12): 880-883, 2023.
Artículo en Chino | WPRIM | ID: wpr-1009153

RESUMEN

OBJECTIVE@#To analyze the effect of lag screw and support plate through axillary approach for the treatment of Ideberg typeⅡscapular pelvis fracture.@*METHODS@#From January 2016 to June 2021, 26 patients with Ideberg typeⅡglenoid fractures were treated with trans-axillary lag screw combined with supporting plate, including 15 males and 11 females. The age ranged from 21 to 75 years, with an average of (43.12±6.56) years old. The Constant-Murley Shoulder joint Scale and University of California at Los Angeles (UCLA) score were used to evaluate the function and clinical efficacy of shoulder joint.@*RESULTS@#All patients were followed up, and the duration ranged from 19 to 42 months, with an average of (30.6±10.5) months. One year after surgery, the Constant-Murley score increased from preoperative 34.9±2.5(ranged, from 28 to 47) to 87.2±6.8(ranged, from 70 to 95). The UCLA score improved from preoperative 17.9±1.7(9 to 25) to 33.1±2.3(29 to 35). Seventeen patients got an excellent result, with 7 good, and 2 fair. None of the patients had infection, screw, and plate loosening, fracture, and other complications after surgery. Two patients had different degrees of Chronic pain in the shoulder during the follow-up period.@*CONCLUSION@#The treatment of Ideberg typeⅡscapular glenoid fractures through axillary approach with lag screws and supporting steel plates has the advantages of convenient exposure, direct visual restoration of the normal anatomical shape of the scapular glenoid, selection of suitable positions for screw and steel plate placement, achieving better treatment results, and fewer complications. It is an effective and reliable surgical method.


Asunto(s)
Femenino , Masculino , Humanos , Adulto Joven , Adulto , Persona de Mediana Edad , Anciano , Escápula , Placas Óseas , Tornillos Óseos , Fracturas Óseas , Acero , Pelvis
12.
China Journal of Orthopaedics and Traumatology ; (12): 754-759, 2023.
Artículo en Chino | WPRIM | ID: wpr-1009130

RESUMEN

OBJECTIVE@#To compare clinical effects of the improved interface screw fixation of femoral end of anterior cruciate ligament with classic femoral lateral loop plate fixation.@*METHODS@#A retrospective analysis of 65 patients who underwent arthroscopic anterior cruciate ligament reconstruction from January 2019 to September 2021 were performed. According to the different fixation methods of the femoral side, 35 patients were divided into loop plate fixation(loop plate group), including 27 males and 8 females, aged from 18 to 50 years old with an average of (35.00±7.60) years old;30 patients in interface screw fixation(interface screw group), including 20 males and 10 females, aged from 18 to 50 years old with an average of (32.00±8.50) years old. Hospital stay, hospital expenses, operation time, complications, C-reactive protein at 1, 3, 6 days after operation, and postoperative Lysholm score and International Knee Documentation Committee(IKDC) score at 18 months were compared between two groups.@*RESULTS@#All patients were successfully operated, and obtained follow-up from 18 to 36 months with an average of (25.16±4.50) months. Anterior drawer test and Lachman test of all patients turned to negative. There were no statistical differences in hospital stay, hospital expenses and complications between two groups(P>0.05);operation time in loop plate group was (74.00±6.84) min, and (91.67±6.34) min in interface screw group, and had difference between two groups(P<0.05). C-reactive protein on the 1st and 3rd day after operation was (40.00±10.10), (20.00±8.23) mg·L-1 in loop plate group, and (60.00±8.93), (30.00±8.66) mg·L-1 in interface nail group, had statistical difference between two groups (P<0.05);while there was no difference in C-reactive protein on the 6th day after operation(P>0.05). At 18 months after operation, Lysholm and IKDC scores showed no significant difference between two groups (P>0.05). In loop plate group, medullary enlargement on coronal and sagittal views were (2.75±0.19) mm, (1.55±0.25) mm, and (2.81±0.22) mm, (1.61±0.20) mm in interface screw group, and had statistical difference between two groups(P<0.05).@*CONCLUSION@#In the reconstruction of anterior cruciate ligament, the common interface screw on the femoral side is changed to the sheath interface screw, and intramedullary screw is changed to the compression and fixation of tendon from outside to inside of joint. Although the operation procedure is relatively complicated and operation time is slightly longer, it has advantages of no residual metal foreign body after operation, and clinical effect is no different from classical loop plate suspension fixation, which is still a good choice.


Asunto(s)
Femenino , Masculino , Humanos , Adolescente , Adulto Joven , Adulto , Persona de Mediana Edad , Proteína C-Reactiva , Estudios Retrospectivos , Fémur , Reconstrucción del Ligamento Cruzado Anterior , Tornillos Óseos
13.
Chinese Journal of Reparative and Reconstructive Surgery ; (12): 1459-1464, 2023.
Artículo en Chino | WPRIM | ID: wpr-1009083

RESUMEN

OBJECTIVE@#To explore the reduction and support effect of the subchondral screw compression technique for residual or secondary collapse of the lateral tibial plateau during operation.@*METHODS@#Between January 2020 and June 2021, 11 patients with residual or secondary collapse of the lateral tibial plateau during operation were treated with the subchondral screw compression technique. There were 6 males and 5 females, aged 52.3 years old (range, 27-64 years). The fractures were caused by traffic accident in 10 cases and falling from height in 1 case and located at the left knee in 6 cases and the right knee in 5 cases. According to Schatzker classification, there were 5 cases of type Ⅱ fractures, 4 cases of type Ⅲ fractures, and 2 cases of type Ⅴfractures. According to the three columns classification, there were 5 cases of lateral column, 4 cases of lateral column and posterior column, and 2 cases of three columns. The time from injury to operation was 4.5 days (range, 3-7 days). During the follow-up, X-ray films were obtained and the Rasmussen standard was used to evaluate the quality of fracture reduction, meanwhile fracture healing was observed. The medial proximal tibial angle (mPTA), posterior tibial slope angle (pTSA), and articular surface collapse were measured at immediate and 12 months after operation. The knee joint range of motion was evaluated at last follow-up, and the knee joint function was evaluated using the Hospital for Special Surgery (HSS) score.@*RESULTS@#All operations were successfully completed, with a mean operation time of 71.4 minutes (range, 55-120 minutes), and a mean hospital stay of 8.0 days (range, 5-13 days). The incisions all healed by first intention, without complications such as infection, flap necrosis, or vascular and nerve injury. All patients were followed up 16.5 months on average (range, 12-24 months). X-ray films showed that the fracture reduction score was 14-18 (mean, 16.7) according to Rasmussen score criteria; and 5 cases were rated as excellent and 6 as good. All fractures healed clinically with a mean clinical healing time of 14.9 weeks (range, 12-16 weeks), and there was no complications such as plate or screw loosening. At 12 months after operation, the mPTA and pTSA were (87.5±1.7)° and (6.2±3.1)°, respectively; there was no significant difference when compared to the values at immediate after operation [(87.6±1.8)° and (6.5±3.1)°] ( P>0.05). The articular surface of the tibial plateaus was effectively supported, and it collapsed again by 0-1.0 mm at 12 months, with an average of 0.4 mm. At last follow-up, the knee joint range of motion was 115°-135° (mean, 126.8°) and the HSS score for knee joint function was 87-98 (mean, 93.9). Five patients underwent secondary operation to remove the internal fixator at 12-18 months after operation.@*CONCLUSION@#The subchondral screw compression technique is helpful for the reduction of residual or secondary collapse of the lateral tibial plateau during operation, and can provide good support for osteochondral blocks.


Asunto(s)
Masculino , Femenino , Humanos , Persona de Mediana Edad , Fracturas de la Tibia/complicaciones , Fijación Interna de Fracturas/métodos , Resultado del Tratamiento , Articulación de la Rodilla/cirugía , Tornillos Óseos , Estudios Retrospectivos
14.
Chinese Journal of Reparative and Reconstructive Surgery ; (12): 1403-1409, 2023.
Artículo en Chino | WPRIM | ID: wpr-1009075

RESUMEN

OBJECTIVE@#To compare the effectiveness of O-arm navigation and ultrasound volume navigation (UVN) in guiding screw placement during minimally invasive transforaminal lumbar interbody fusion (MIS-TLIF) surgery.@*METHODS@#Sixty patients who underwent MIS-TLIF surgery for lumbar disc herniation between June 2022 and June 2023 and met the selection criteria were included in the study. They were randomly assigned to group A (screw placement guided by UVN during MIS-TLIF) or group B (screw placement guided by O-arm navigation during MIS-TLIF), with 30 cases in each group. There was no significant difference in baseline data, including gender, age, body mass index, and surgical segment, between the two groups ( P>0.05). Intraoperative data, including average single screw placement time, total radiation dose, and average single screw effective radiation dose, were recorded and calculated. Postoperatively, X-ray film and CT scans were performed at 10 days to evaluate screw placement accuracy and assess facet joint violation. Pearson correlation and Spearman correlation analyses were used to observe the relationship between the studied parameters (average single screw placement time and screw placement accuracy grading) and BMI.@*RESULTS@#The average single screw placement time in group B was significantly shorter than that in group A, and the total radiation dose of single segment and multi-segment and the average single screw effective radiation dose in group B were significantly higher than those in group A ( P<0.05). There was no significant difference in the total radiation dose between single segment and multiple segments in group B ( P>0.05), while the total radiation dose of multiple segments was significantly higher than that of single segment in group A ( P<0.05). No significant difference was found in the accuracy of screw implantation between the two groups ( P>0.05). In both groups, the grade 1 and grade 2 screws broke through the outer wall of the pedicle, and no screw broke through the inner wall of the pedicle. There was no significant difference in the rate of facet joint violation between the two groups ( P>0.05). In group A, both the average single screw placement time and screw placement accuracy grading were positively correlated with BMI ( r=0.677, P<0.001; r=0.222, P=0.012), while in group B, neither of them was correlated with BMI ( r=0.224, P=0.233; r=0.034, P=0.697).@*CONCLUSION@#UVN-guided screw placement in MIS-TLIF surgery demonstrates comparable efficiency, visualization, and accuracy to O-arm navigation, while significantly reducing radiation exposure. However, it may be influenced by factors such as obesity, which poses certain limitations.


Asunto(s)
Humanos , Imagenología Tridimensional , Vértebras Lumbares/cirugía , Procedimientos Quirúrgicos Mínimamente Invasivos , Tornillos Pediculares , Estudios Retrospectivos , Fusión Vertebral , Cirugía Asistida por Computador , Tomografía Computarizada por Rayos X , Resultado del Tratamiento
15.
Chinese Journal of Reparative and Reconstructive Surgery ; (12): 1386-1389, 2023.
Artículo en Chino | WPRIM | ID: wpr-1009072

RESUMEN

OBJECTIVE@#To explore the effectiveness of arthroscopic treatment of scaphoid fracture nonunion with bone graft and Kirschner wire combined with screw fixation.@*METHODS@#The clinical data of 14 patients with scaphoid fracture nonunion who met the selection criteria between February 2021 and September 2022 were retrospectively analyzed. There were 13 males and 1 female with an average age of 32 years ranging from 17 to 54 years. The time from injury to operation ranged from 6 to 15 months, with an average of 9.6 months. According to the Slade-Geissler classification of scaphoid fracture nonunion, there were 3 cases of grade Ⅲ, 8 cases of grade Ⅳ, and 3 cases of grade Ⅴ. The preoperative visual analogue scale (VAS) score was 5.9±1.0, and the modified Mayo wrist score was 53.2±9.1. There were 2 cases of scaphoid nonunion advanced collapse, both of which were stage Ⅰ. All patients were treated with arthroscopic bone graft and Kirschner wire combined with screw fixation, and the fracture healing was observed by X-ray film monthly after operation, and the effectiveness was evaluated by VAS score and modified Mayo wrist score before and after operation.@*RESULTS@#All patients were followed up 6-14 months, with an average of 8.4 months. All fractures healed in 4-8 months, with an average of 6.3 months. The postoperative pain symptoms and wrist function of the patients significantly improved when compared with those before operation, and the VAS score at last follow-up was 2.4±1.3, and the modified Mayo wrist score was 87.1±6.7, which were significantly different from those before operation ( t=12.851, P<0.001; t=-14.410, P<0.001). According to the modified Mayo wrist evaluation, 9 cases were excellent, 3 cases were good, and 2 cases were fair.@*CONCLUSION@#Arthroscopic bone graft and Kirschner wire combined with screw fixation is an effective surgical method for the treatment of scaphoid fracture nonunion.


Asunto(s)
Masculino , Humanos , Femenino , Adulto , Fracturas Óseas/cirugía , Hilos Ortopédicos , Hueso Escafoides/lesiones , Estudios Retrospectivos , Fijación Interna de Fracturas/métodos , Fracturas no Consolidadas/cirugía , Traumatismos de la Muñeca/cirugía , Tornillos Óseos , Traumatismos de la Mano , Resultado del Tratamiento
16.
Chinese Journal of Reparative and Reconstructive Surgery ; (12): 1375-1379, 2023.
Artículo en Chino | WPRIM | ID: wpr-1009070

RESUMEN

OBJECTIVE@#To investigate the effectiveness of compression screw combined with Buttress plate through direct axillary approach for Ideberg typeⅡ scapular glenoid fractures.@*METHODS@#A retrospective analysis was conducted on 11 patients with Ideberg type Ⅱ scapular glenoid fractures treated with compression screws combined with Buttress plate fixation through the direct axillary approach between January 2014 and June 2022. There were 7 males and 4 females, aged from 34 to 75 years, with an average of 56.0 years. The causes of injury included 4 cases of falling from height injury, 4 cases of heavy object injury, and 3 cases of traffic accident injury. The time from injury to operation was 2-5 days, with an average of 3.8 days. The operation time, intraoperative blood loss, hospital stay, complications, and fracture healing time were recorded. The Constant-Murley score, American Society of Shoulder and Elbow Surgeons (ASES) score, and shoulder joint flexion, abduction, external rotation (neutral position), and internal rotation (neutral position) range of motion were used to evaluate shoulder joint pain and function.@*RESULTS@#The operation time was 45-105 minutes, with an average of 79.0 minutes; the intraoperative blood loss was 80-200 mL, with an average of 99.2 mL; the hospital stay was 3-8 days, with an average of 5.8 days. One patient had poor wound healing after operation, and the wound healed after strengthening dressing change; the rest wounds had primary healing, and no axillary nerve paralysis occurred. Except for 1 patient lost follow-up, the remaining 10 patients were followed up 10-54 months, with an average of 26.4 months. The postoperative X-ray film examination showed that the fractures healed well within 8-15 weeks, with an average of 11.0 weeks. There was no complication such as fracture displacement, internal fixator failure or fracture during follow-up. At last follow-up, the patient's shoulder joint flexion, abduction, external rotation (neutral position), and internal rotation (neutral position) range of motion, Constant-Murley score, and ASES score significantly improved when compared with those before operation ( P<0.05).@*CONCLUSION@#Compression screw combined with Buttress plate through direct axillary approach is an effective way to treat Ideberg typeⅡ scapular glenoid fracture, with advantages of small trauma, concealed incision, and good effectiveness.


Asunto(s)
Masculino , Femenino , Humanos , Estudios Retrospectivos , Pérdida de Sangre Quirúrgica , Fijación Interna de Fracturas , Resultado del Tratamiento , Fracturas del Hombro/cirugía , Tornillos Óseos , Placas Óseas
17.
Chinese Journal of Reparative and Reconstructive Surgery ; (12): 1347-1352, 2023.
Artículo en Chino | WPRIM | ID: wpr-1009066

RESUMEN

OBJECTIVE@#To explore the effectiveness of the percutaneous parallel screw fixation via the posterolateral "safe zone" for Hawkins type Ⅰ-Ⅲ talar neck fractures.@*METHODS@#A retrospective analysis was conducted on the clinical data from 35 patients who met the selection criteria of talar neck fractures between January 2019 and June 2021. According to the surgical method, they were divided into a study group (14 cases, using percutaneous posterolateral "safe zone" parallel screw fixation) and a control group (21 cases, using traditional open reduction and anterior cross screw internal fixation). There was no significant difference in gender, age, affected side, Hawkins classification, and time from injury to operation between the two groups ( P>0.05). The operation time, bone healing time, complications, and Hawkins sign were recorded, and the improvement of pain and ankle-foot function were evaluated by visual analogue scale (VAS) score and American Orthopaedic Foot and Ankle Society (AOFAS) ankle and hindfoot score at last follow-up. The overall quality of life was assessed by the short form of 12-item health survey (SF-12), which was divided into physical and psychological scores; and the satisfaction of patients was evaluated by the 5-point Likert scale.@*RESULTS@#The operation time in the study group was significantly shorter than that in the control group ( P<0.05). All patients werefollowed up 13-35 months, with an average of 20.6 months; there was no significant difference in the follow-up time between the two groups ( P>0.05). The time of bone healing in the study group was shorter than that in the control group, and the positive rate of Hawkins sign (83.33%) was higher than that in the control group (33.33%), and the differences were significant ( P<0.05). In the control group, there were 2 cases of incision delayed healing, 7 cases of avascular necrosis of bone, 3 cases of joint degeneration, 1 case of bone nonunion, and 3 cases of internal fixation irritation; while in the study group, there were only 2 cases of joint degeneration, and there was a significant difference in the incidence of complications between the two groups ( P<0.05). At last follow-up, there was no significant difference in VAS score between the two groups ( P>0.05), but the SF-12 physical and psychological scores, AOFAS ankle and hindfoot scores, and patients' satisfaction in the study group were significantly better than those in the control group ( P<0.05).@*CONCLUSION@#The treatment of Hawkins type Ⅰ-Ⅲ talar neck fractures with percutaneous parallel screw fixation via the posterolateral "safe zone" can achieve better effectiveness than traditional open surgery, with the advantages of less trauma, fewer complications, faster recovery, and higher patient satisfaction.


Asunto(s)
Humanos , Estudios Retrospectivos , Calidad de Vida , Fracturas Óseas/cirugía , Fijación Interna de Fracturas/métodos , Tornillos Óseos , Luxaciones Articulares , Resultado del Tratamiento
18.
Chinese Journal of Reparative and Reconstructive Surgery ; (12): 1253-1258, 2023.
Artículo en Chino | WPRIM | ID: wpr-1009053

RESUMEN

OBJECTIVE@#To explore the feasibility and accuracy of ultrasound volume navigation (UVN) combined with X-ray fluoroscopy-guided percutaneous pedicle screw implantation through a prospective randomized controlled study.@*METHODS@#Patients with thoracic and lumbar vertebral fractures scheduled for percutaneous pedicle screw fixation between January 2022 and January 2023 were enrolled. Among them, 60 patients met the selection criteria and were included in the study. There were 28 males and 32 females, with an average age of 49.5 years (range, 29-60 years). The cause of injury included 20 cases of traffic accidents, 21 cases of falls, 17 cases of slips, and 2 cases of heavy object impact. The interval from injury to hospital admission ranged from 1 to 5 days (mean, 1.57 days). The fracture located at T 12 in 15 cases, L 1 in 20 cases, L 2 in 19 cases, and L 3 in 6 cases. The study used each patient as their own control, randomly guiding pedicle screw implantation using UVN combined with X-ray fluoroscopy on one side of the vertebral body and the adjacent segment (trial group), while the other side was implanted under X-ray fluoroscopy (control group). A total of 4 screws and 2 rods were implanted in each patient. The implantation time and fluoroscopy frequency during implantation of each screw, angle deviation and distance deviation between actual and preoperative planned trajectory by imaging examination, and the occurrence of zygapophysial joint invasion were recorded.@*RESULTS@#In terms of screw implantation time, fluoroscopy frequency, angle deviation, distance deviation, and incidence of zygapophysial joint invasion, the trial group showed superior results compared to the control group, and the differences were significant ( P<0.05).@*CONCLUSION@#UVN combined with X-ray fluoroscopy-guided percutaneous pedicle screw implantation can yreduce screw implantation time, adjust dynamically, reduce operational difficulty, and reduce radiation damage.


Asunto(s)
Masculino , Femenino , Humanos , Persona de Mediana Edad , Tornillos Pediculares , Estudios Prospectivos , Rayos X , Cirugía Asistida por Computador/métodos , Fusión Vertebral/métodos , Fluoroscopía/métodos , Vértebras Lumbares/lesiones
19.
Chinese Journal of Reparative and Reconstructive Surgery ; (12): 1205-1213, 2023.
Artículo en Chino | WPRIM | ID: wpr-1009046

RESUMEN

OBJECTIVE@#To compare the biomechanical differences among the five internal fixation modes in treatment of Day type Ⅱ crescent fracture dislocation of pelvis (CFDP), and find an internal fixation mode which was the most consistent with mechanical principles.@*METHODS@#Based on the pelvic CT data of a healthy adult male volunteer, a Day type Ⅱ CFDP finite element model was established by using Mimics 17.0, ANSYS 12.0-ICEM, Abaqus 2020, and SolidWorks 2012 softwares. After verifying the validity of the finite element model by comparing the anatomical parameters with the three-dimensional reconstruction model and the mechanical validity verification, the fracture and dislocated joint of models were fixed with S 1 sacroiliac screw combined with 1 LC-Ⅱ screw (S 1+LC-Ⅱ group), S 1 sacroiliac screw combined with 2 LC-Ⅱ screws (S 1+2LC-Ⅱ group), S 1 sacroiliac screw combined with 2 posterior iliac screws (S 1+2PIS group), S 1 and S 2 sacroiliac screws combined with 1 LC-Ⅱ screw (S 1+S 2+LC-Ⅱ group), S 2-alar-iliac (S 2AI) screw combined with 1 LC-Ⅱ screw (S 2AI+LC-Ⅱ group), respectively. After each internal fixation model was loaded with a force of 600 N in the standing position, the maximum displacement of the crescent fracture fragments, the maximum stress of the internal fixation (the maximum stress of the screw at the ilium fracture and the maximum stress of the screw at the sacroiliac joint), sacroiliac joint displacement, and bone stress distribution around internal fixation were observed in 5 groups.@*RESULTS@#The finite element model in this study has been verified to be effective. After loading 600 N stress, there was a certain displacement of the crescent fracture of pelvis in each internal fixation model, among which the S 1+LC-Ⅱ group was the largest, the S 1+2LC-Ⅱ group and the S 1+2PIS group were the smallest. The maximum stress of the internal fixation mainly concentrated at the sacroiliac joint and the fracture line of crescent fracture. The maximum stress of the screw at the sacroiliac joint was the largest in the S 1+LC-Ⅱ group and the smallest in the S 2AI+LC-Ⅱ group. The maximum stress of the screw at the ilium fracture was the largest in the S 1+2PIS group and the smallest in the S 1+2LC-Ⅱ group. The displacement of the sacroiliac joint was the largest in the S 1+LC-Ⅱ group and the smallest in the S 1+S 2+LC-Ⅱ group. In each internal fixation model, the maximum stress around the sacroiliac screws concentrated on the contact surface between the screw and the cortical bone, the maximum stress around the screws at the iliac bone concentrated on the cancellous bone of the fracture line, and the maximum stress around the S 2AI screw concentrated on the cancellous bone on the iliac side. The maximum bone stress around the screws at the sacroiliac joint was the largest in the S 1+LC-Ⅱ group and the smallest in the S 2AI+LC-Ⅱ group. The maximum bone stress around the screws at the ilium was the largest in the S 1+2PIS group and the smallest in the S 1+LC-Ⅱ group.@*CONCLUSION@#For the treatment of Day type Ⅱ CFDP, it is recommended to choose S 1 sacroiliac screw combined with 1 LC-Ⅱ screw for internal fixation, which can achieve a firm fixation effect without increasing the number of screws.


Asunto(s)
Adulto , Masculino , Humanos , Análisis de Elementos Finitos , Fijación Interna de Fracturas/métodos , Fracturas Óseas/cirugía , Pelvis , Fracturas de la Columna Vertebral/cirugía , Fractura-Luxación/cirugía , Luxaciones Articulares/cirugía , Fenómenos Biomecánicos
20.
Chinese Journal of Reparative and Reconstructive Surgery ; (12): 1049-1054, 2023.
Artículo en Chino | WPRIM | ID: wpr-1009022

RESUMEN

OBJECTIVE@#To investigate the early effectiveness of transiliac-transsacral screws internal fixation assisted by augmented reality navigation system HoloSight (hereinafter referred to as "computer navigation system") in the treatment of posterior pelvic ring injuries.@*METHODS@#A retrospective analysis was made in the 41 patients with posterior pelvic ring injuries who had been treated surgically with transiliac-transsacral screws between June 2022 and June 2023. The patients were divided into navigation group (18 cases, using computer navigation system to assist screw implantation) and freehand group (23 cases, using C-arm X-ray fluoroscopy to guide screw implantation) according to the different methods of transiliac-transsacral screws placement. There was no significant difference in gender, age, body mass index, causes of injuries, Tile classification of pelvic fracture, days from injury to operation, usage of unlocking closed reduction technique between the two groups ( P>0.05). The time of screw implantation, the fluoroscopy times, the guide wire adjustment times of each screw, and the incidence of complications were recorded and compared between the two groups. The position of the transiliac-transsacral screw was scanned by CT within 2 days after operation, and the position of the screw was classified according to Gras standard.@*RESULTS@#The operation was successfully completed in both groups. The time of screw implantation, the fluoroscopy times, and the guide wire adjustment times of each screw in the navigation group were significantly less than those in the freehand group ( P<0.05). There were 2 cases of incision infection in the freehand group, and the incision healed by first intention after active dressing change; there was no screw-related complication in the navigation group during operation and early period after operation; the difference in incidence of complications between the two groups (8.7% vs. 0) was not significant ( P=0.495). According to the Gras standard, the screw position of the navigation group was significantly better than that of the freehand group ( P<0.05).@*CONCLUSION@#Compared with the traditional freehand method, the computer navigation system assisted transiliac-transsacral screws internal fixation in the treatment of posterior pelvic ring injuries has advantages of improving the accuracy of screw implantation and reducing radiation damage and the time of screw implantation.


Asunto(s)
Humanos , Estudios Retrospectivos , Infección de la Herida Quirúrgica , Reimplantación , Índice de Masa Corporal
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA