Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 183
Filtrar
1.
Journal of Preventive Medicine ; (12): 39-43, 2024.
Artículo en Chino | WPRIM | ID: wpr-1016500

RESUMEN

Objective @#To investigate the prevalence of occupational injury and identify its influencing factors among workers in a steel enterprise in Gansu Province, so as to provide insights into prevention of occupational injury among steel workers. @*Methods@#Workers were sampled from a steel enterprise in Gansu Province using a cluster sampling method from January to March 2022, and participants' demographics, occupational history and occupational injury were collected using questionnaire surveys. The type of job and site and type of injury were analyzed among workers with occupational injuries, and factors affecting workers' occupational injuries were identified using a multivariable logistic regression model. @*Results@#A total of 12 089 questionnaires were allocated and 10 725 valid questionnaires were recovered, with an effective recovery rate of 88.71%. The respondents included 9 412 males (87.77%) and 1 312 females (12.23%), and had a median age of 36.00 (interquartile range, 15.00) years. Junior college and above was the predominant educational level (6 056 workers, 56.47%), and the respondents had a median length of service of 10 (interquartile range, 11) years. The prevalence of occupational injury was 5.25% among respondents. Overhaul worker was the main type of job (11.90%), and object strike was the predominant type of occupational injury (18.25%), while the lower limb was the predominant site of injury (27.82%). Multivariable logistic regression analysis identified men (OR=2.464, 95%CI: 1.580-3.843), age (30 to 39 years, OR=2.561, 95%CI: 1.643-3.993; 40 to 49 years, OR=5.197, 95%CI: 2.679-10.079; 50 years and older, OR=10.620, 95%CI: 6.788-16.615), exposure to high temperature (OR=1.400, 95%CI: 1.165-1.683), operating equipment failure (OR=1.291, 95%CI: 1.048-1.591), absence of personal safety protection equipment (OR=1.555, 95%CI: 1.064-2.273) and safety behavior scores (OR=0.967, 95%CI: 0.937-0.996) as factors affecting occupational injuries among workers in a steel enterprise. @*Conclusions@#Men and overhaul workers are at a high risk of occupational injuries in this steel enterprise. Objectstrike is the predominant type of injury and lower limb is the main site of injury. The risk of occupational injuries is affected by gender, age, working environments, equipment status and safety behaviors.

2.
Dental press j. orthod. (Impr.) ; 29(2): e2423282, 2024. tab, graf
Artículo en Inglés | LILACS-Express | LILACS, BBO | ID: biblio-1557696

RESUMEN

ABSTRACT Objective: This study aimed to compare the insertion torque (IT), flexural strength (FS) and surface alterations between stainless steel (SS-MIs) and titanium alloy (Ti-MIs) orthodontic mini-implants. Methods: Twenty-four MIs (2 x 10 mm; SS-MIs, n = 12; Ti-MIs, n = 12) were inserted on artificial bone blocks of 20 lb/ft3 (20 PCF) and 40 lb/ft3 (40 PCF) density. The maximum IT was recorded using a digital torque meter. FS was evaluated at 2, 3 and 4 mm-deflection. Surface topography and chemical composition of MIs were assessed by scanning electron microscopy (SEM) and energy dispersive X-ray spectroscopy (EDS). General linear and mixed models were used to assess the effect of the MI type, bone density and deflection on the evaluated outcomes. Results: The IT of Ti-MIs was 1.1 Ncm greater than that obtained for the SS-MIs (p= 0.018). The IT for MIs inserted in 40 PCF test blocks was 5.4 Ncm greater than that for those inserted in 20 PCF test blocks (p < 0.001). SS-MIs inserted in higher density bone (40 PCF) had significantly higher flexural strength than the other groups, at 2 mm (98.7 ± 5.1 Ncm), 3 mm (112.0 ± 3.9 Ncm) and 4 mm (120.0 ± 3.4 Ncm) of deflection (p< 0.001). SEM evidenced fractures in the Ti-MIs. EDS revealed incorporation of 18% of C and 2.06% of O in the loaded SS-MIs, and 3.91% of C in the loaded Ti-MIs. Conclusions: Based on the findings of this in vitro study, it seems that SS-MIs offer sufficient stability and exhibit greater mechanical strength, compared to Ti-MIs when inserted into higher density bone.


RESUMO Objetivo: O objetivo deste estudo foi comparar o torque de inserção (TI), a resistência flexural (RF) e as alterações de superfície em mini-implantes ortodônticos de aço inoxidável (MIs-Ai) e de liga de titânio (MIs-Ti). Métodos: Vinte e quatro MIs (2 x 10 mm; MIs-Ai, n = 12; MIs-Ti, n = 12) foram inseridos em blocos de osso artificial de densidades de 20 lb/ft3 (20 PCF) e 40 lb/ft3 (40 PCF). O torque máximo de inserção foi registrado por meio de um torquímetro digital. A resistência flexural foi avaliada nas deflexões de 2, 3 e 4 mm. Topografia de superfície e composição química dos MIs foram avaliadas por Microscopia Eletrônica de Varredura (MEV) e Espectroscopia de Energia Dispersiva de Raios X (EDS). Modelos lineares gerais e mistos foram utilizados para avaliar o efeito do tipo de MI, da densidade óssea e da deflexão nos desfechos avaliados. Resultados: O TI dos MIs-Ti foi 1,1 Ncm maior do que o obtido para os MIs-Ai (P = 0,018). O TI para MIs inseridos em blocos de teste de 40 PCF foi 5,4 Ncm maior do que para aqueles inseridos em blocos de teste 20 PCF (p < 0,001). MIs-Ai inseridos em osso de maior densidade (40 PCF) apresentaram resistência flexural significativamente maior do que outros grupos, em deflexões de 2 mm (98,7 ± 5,1 Ncm), 3 mm (112,0 ± 3,9 Ncm) e 4 mm (120,0 ± 3,4 Ncm) (p < 0,001). A MEV evidenciou fraturas nos MIs-Ti. A EDS revelou incorporação de 18% de C e 2,06% de O nos MIs-Ai e 3,91% de C nos MIs-Ti, ambos submetidos a testes mecânicos. Conclusões: Com base nos resultados desse estudo in vitro, os MIs-Ai aparentam oferecer adequada estabilidade e maior resistência mecânica, em comparação aos MIs-Ti, quando inseridos em osso de maior densidade.

3.
Rev. argent. microbiol ; 55(4): 3-3, Dec. 2023.
Artículo en Inglés | LILACS-Express | LILACS | ID: biblio-1550710

RESUMEN

Abstract The use of lactic acid bacteria (LAB) in foods as biocontrol agents against foodborne pathogens has become increasingly known. Under the premise that controlling the adhesion of microorganisms to food contact surfaces is an essential step for meeting the goals of food processing, the aim of this work was to investigate the inhibitory and anti-biofilm effectiveness of Lactobacillus rhamnosus GG (ATCC 53103) and Lactobacillus casei (ATCC 393) against Escherichia coli O157:H7, Salmonella enterica and Listeria monocytogenes. Lactobacillus strains (108UFCCFU/ml) and pathogens (104UFCCFU/ml) were evaluated to monitor LAB anti-adhesive and antibiofilm effect, in two main scenarios: (i) co-adhesion and (ii) pathogen incorporation to stainless steel surfaces with a protective biofilm of Lactobacillus cells. In (i) the predominant effect was observed in L. rhamnosus against S. enterica and L. monocytogenes, whereas in (ii) both LAB significantly reduced the number of pathogenic adherent cells. The effect of pre-established LAB biofilms was more successful in displacing the three pathogens than when they were evaluated under co-adhesion. These findings show that both LAB can be considered good candidates to prevent or inhibit the adhesion and colonization of L. monocytogenes, S. enterica and E. coli O157:H7 on surfaces and conditions of relevance for juice processing industries, offering alternatives for improving the safety and quality of fruit-based products.


Resumen Existe un creciente interés en el uso de bacterias ácido lácticas (BAL) como agentes de biocontrol frente a patógenos de transmisión alimentaria. Bajo la premisa de que el control de la adhesión de microorganismos a superficies de contacto con alimentos es el paso esencial para evitar su contaminación, el objetivo de este trabajo fue investigar la efectividad inhibitoria y antibiofilm de Lactobacillus rhamnosus GG (ATCC 53103) y Lactobacillus casei (ATCC 393) frente a Escherichia coli O157:H7, Salmonella enterica y Listeria monocytogenes. A fin de cumplir con el objetivo propuesto, las cepas de Lactobacillus (108UFCUFC/ml) y los patógenos (104UFCUFC/ml) se ensayaron en 2 escenarios: (1) coadhesión, y (2) incorporación de los patógenos a las superficies de acero inoxidable con un biofilm preformado de Lactobacillus. En (1), el efecto predominante se observó con L. rhamnosus frente a S. enterica y L. monocytogenes, mientras que en (2), ambas BAL redujeron significativamente el número de células patógenas adheridas. En función de estos resultados, concluimos que el efecto de un biofilm preformado de ambas BAL fue más exitoso en el desplazamiento de los 3 patógenos que en coadhesión. Ambas BAL pueden considerarse buenas candidatas para mitigar la adhesión y colonización de L. monocytogenes, S. enterica y E. coli O157:H7 en superficies en condiciones de relevancia para la industria procesadora de jugos, y, de esta manera, ofrecer alternativas para mejorar la seguridad y calidad de los alimentos a base de frutas.

4.
Artículo | IMSEAR | ID: sea-220668

RESUMEN

The present study aims to identify the ?nancial strengths and weaknesses of the salem steel plant by properly establishing relationships between the items of the balance sheet and pro?t and loss account. The study covers Salem Steel Plant, a special steels unit of Steel Authority of India Ltd, pioneered the supply of wider width stainless steel sheets / coils in India. The study has been undertaken for the period of twelve years from 2011-12 to 2020-21and the necessary data have been obtained from SAIL database. The liquidity position was strong in case of both the selected companies thereby re?ecting the ability of the companies to pay short-term obligations on due dates and they relied more on external funds in terms of long-term borrowings thereby providing a lower degree of protection to the creditors. The study will help investors to identify the nature of SAIL industry and will also help to take decision regarding investment.

5.
China Journal of Orthopaedics and Traumatology ; (12): 880-883, 2023.
Artículo en Chino | WPRIM | ID: wpr-1009153

RESUMEN

OBJECTIVE@#To analyze the effect of lag screw and support plate through axillary approach for the treatment of Ideberg typeⅡscapular pelvis fracture.@*METHODS@#From January 2016 to June 2021, 26 patients with Ideberg typeⅡglenoid fractures were treated with trans-axillary lag screw combined with supporting plate, including 15 males and 11 females. The age ranged from 21 to 75 years, with an average of (43.12±6.56) years old. The Constant-Murley Shoulder joint Scale and University of California at Los Angeles (UCLA) score were used to evaluate the function and clinical efficacy of shoulder joint.@*RESULTS@#All patients were followed up, and the duration ranged from 19 to 42 months, with an average of (30.6±10.5) months. One year after surgery, the Constant-Murley score increased from preoperative 34.9±2.5(ranged, from 28 to 47) to 87.2±6.8(ranged, from 70 to 95). The UCLA score improved from preoperative 17.9±1.7(9 to 25) to 33.1±2.3(29 to 35). Seventeen patients got an excellent result, with 7 good, and 2 fair. None of the patients had infection, screw, and plate loosening, fracture, and other complications after surgery. Two patients had different degrees of Chronic pain in the shoulder during the follow-up period.@*CONCLUSION@#The treatment of Ideberg typeⅡscapular glenoid fractures through axillary approach with lag screws and supporting steel plates has the advantages of convenient exposure, direct visual restoration of the normal anatomical shape of the scapular glenoid, selection of suitable positions for screw and steel plate placement, achieving better treatment results, and fewer complications. It is an effective and reliable surgical method.


Asunto(s)
Femenino , Masculino , Humanos , Adulto Joven , Adulto , Persona de Mediana Edad , Anciano , Escápula , Placas Óseas , Tornillos Óseos , Fracturas Óseas , Acero , Pelvis
6.
China Journal of Orthopaedics and Traumatology ; (12): 754-759, 2023.
Artículo en Chino | WPRIM | ID: wpr-1009130

RESUMEN

OBJECTIVE@#To compare clinical effects of the improved interface screw fixation of femoral end of anterior cruciate ligament with classic femoral lateral loop plate fixation.@*METHODS@#A retrospective analysis of 65 patients who underwent arthroscopic anterior cruciate ligament reconstruction from January 2019 to September 2021 were performed. According to the different fixation methods of the femoral side, 35 patients were divided into loop plate fixation(loop plate group), including 27 males and 8 females, aged from 18 to 50 years old with an average of (35.00±7.60) years old;30 patients in interface screw fixation(interface screw group), including 20 males and 10 females, aged from 18 to 50 years old with an average of (32.00±8.50) years old. Hospital stay, hospital expenses, operation time, complications, C-reactive protein at 1, 3, 6 days after operation, and postoperative Lysholm score and International Knee Documentation Committee(IKDC) score at 18 months were compared between two groups.@*RESULTS@#All patients were successfully operated, and obtained follow-up from 18 to 36 months with an average of (25.16±4.50) months. Anterior drawer test and Lachman test of all patients turned to negative. There were no statistical differences in hospital stay, hospital expenses and complications between two groups(P>0.05);operation time in loop plate group was (74.00±6.84) min, and (91.67±6.34) min in interface screw group, and had difference between two groups(P<0.05). C-reactive protein on the 1st and 3rd day after operation was (40.00±10.10), (20.00±8.23) mg·L-1 in loop plate group, and (60.00±8.93), (30.00±8.66) mg·L-1 in interface nail group, had statistical difference between two groups (P<0.05);while there was no difference in C-reactive protein on the 6th day after operation(P>0.05). At 18 months after operation, Lysholm and IKDC scores showed no significant difference between two groups (P>0.05). In loop plate group, medullary enlargement on coronal and sagittal views were (2.75±0.19) mm, (1.55±0.25) mm, and (2.81±0.22) mm, (1.61±0.20) mm in interface screw group, and had statistical difference between two groups(P<0.05).@*CONCLUSION@#In the reconstruction of anterior cruciate ligament, the common interface screw on the femoral side is changed to the sheath interface screw, and intramedullary screw is changed to the compression and fixation of tendon from outside to inside of joint. Although the operation procedure is relatively complicated and operation time is slightly longer, it has advantages of no residual metal foreign body after operation, and clinical effect is no different from classical loop plate suspension fixation, which is still a good choice.


Asunto(s)
Femenino , Masculino , Humanos , Adolescente , Adulto Joven , Adulto , Persona de Mediana Edad , Proteína C-Reactiva , Estudios Retrospectivos , Fémur , Reconstrucción del Ligamento Cruzado Anterior , Tornillos Óseos
7.
China Journal of Orthopaedics and Traumatology ; (12): 440-444, 2023.
Artículo en Chino | WPRIM | ID: wpr-981712

RESUMEN

OBJECTIVE@#To compare the clinical efficacy of micro steel plate and Kirschner needle oblique and transverse internal fixation of adjacent metacarpal bone in the treatment of metacarpal diaphyseal oblique fracture.@*METHODS@#Fifty-nine patients with metacarpal diaphyseal oblique fractures admitted between January 2018 and September 2021 were selected as the study subjects and divided into the observation group (29 cases) and the control group (30 cases) based on different internal fixation methods. The observation group was treated with Kirschner wire oblique and transverse internal fixation of adjacent metacarpal bones, while the control group was treated with micro steel plate internal fixation. Postoperative complications, operation time, incision length, fracture healing time, treatment cost, and metacarpophalangeal function were compared between the two groups.@*RESULTS@#No incision or Kirschner wire infections occurred in the 59 patients, except for one in the observation group. No fixation loosening, rupture, or loss of fracture reduction occurred in any of the patients. The operation time and incision length in the observation group were (20.5±4.2) min and (1.6±0.2) cm, respectively, which were significantly shorter than those in the control group (30.8±5.6) min and (4.3±0.8) cm (P<0.05). The treatment cost and fracture healing time in the observation group were (3 804.5±300.8) yuan and (7.2±1.1) weeks, respectively, which were significantly lower than those in the control group (9 906.9±860.6) yuan and (9.3±1.7) weeks (P<0.05). The excellent and good rate of metacarpophalangeal joint function in the observation group was significantly higher than that in the control group at 1, 2, and 3 months after operation (P<0.05), but there was no significant difference between the two groups at 6 months after operation (P>0.05).@*CONCLUSION@#Micro steel plate internal fixation and Kirschner wire oblique and transverse internal fixation of adjacent metacarpal bones are both viable surgical methods for treating metacarpal diaphyseal oblique fractures. However, the latter has the advantages of causing less surgical trauma, shorter operation time, better fracture healing, lower cost of fixation materials, and no need for secondary incision and removal of internal fixation.


Asunto(s)
Humanos , Huesos del Metacarpo/lesiones , Fracturas Óseas/cirugía , Fijación Interna de Fracturas/métodos , Hilos Ortopédicos , Placas Óseas , Resultado del Tratamiento
8.
Journal of Biomedical Engineering ; (6): 552-558, 2023.
Artículo en Chino | WPRIM | ID: wpr-981575

RESUMEN

The interventional therapy of vascular stent implantation is a popular treatment method for cardiovascular stenosis and blockage. However, traditional stent manufacturing methods such as laser cutting are complex and cannot easily manufacture complex structures such as bifurcated stents, while three-dimensional (3D) printing technology provides a new method for manufacturing stents with complex structure and personalized designs. In this paper, a cardiovascular stent was designed, and printed using selective laser melting technology and 316L stainless steel powder of 0-10 µm size. Electrolytic polishing was performed to improve the surface quality of the printed vascular stent, and the expansion behavior of the polished stent was assessed by balloon inflation. The results showed that the newly designed cardiovascular stent could be manufactured by 3D printing technology. Electrolytic polishing removed the attached powder and reduced the surface roughness Ra from 1.36 µm to 0.82 µm. The axial shortening rate of the polished bracket was 4.23% when the outside diameter was expanded from 2.42 mm to 3.63 mm under the pressure of the balloon, and the radial rebound rate was 2.48% after unloading. The radial force of polished stent was 8.32 N. The 3D printed vascular stent can remove the surface powder through electrolytic polishing to improve the surface quality, and show good dilatation performance and radial support performance, which provides a reference for the practical application of 3D printed vascular stent.


Asunto(s)
Humanos , Acero Inoxidable , Polvos , Sistema Cardiovascular , Constricción Patológica
9.
Journal of Southern Medical University ; (12): 1233-1240, 2023.
Artículo en Chino | WPRIM | ID: wpr-987040

RESUMEN

OBJECTIVE@#To propose a sensitivity test method for geometric correction position deviation of cone-beam CT systems.@*METHODS@#We proposed the definition of center deviation and its derivation. We analyzed the influence of the variation of the three-dimensional spatial center of the steel ball point, the projection center and the size of the steel ball point on the deviation of geometric parameters and the reconstructed image results by calculating the geometric correction parameters based on the Noo analytical method using the FDK reconstruction algorithm for image reconstruction.@*RESULTS@#The radius of the steel ball point was within 3 mm. The deviation of the center of the calibration parameter was within the order of magnitude and negligible. A 10% Gaussian perturbation of a single pixel in the 3D spatial coordinates of the steel ball point produced a deviation of about 3 pixel sizes, while the same Gaussian perturbation of the 2D projection coordinates of the steel ball point produced a deviation of about 2 pixel sizes.@*CONCLUSION@#The geometric correction is more sensitive to the deviation generated by the three-dimensional spatial coordinates of the steel ball point with limited sensitivity to the deviation generated by the two-dimensional projection coordinates of the steel ball point. The deviation sensitivity of a small diameter steel ball point can be ignored.


Asunto(s)
Algoritmos , Calibración , Tomografía Computarizada de Haz Cónico , Acero
10.
Chinese Journal of Primary Medicine and Pharmacy ; (12): 375-378, 2023.
Artículo en Chino | WPRIM | ID: wpr-991757

RESUMEN

Objective:To investigate the efficacy of a proximal femoral locking plate (LPFP) versus a proximal femoral anti-rotation intramedullary nail (PFNA) in the treatment of femoral intertrochanteric fractures in older adult patients. Methods:A total of 130 older adult patients with femoral intertrochanteric fractures who received treatment in Linghu People's Hospital of Huzhou from May 2017 to June 2020 were included in this study. They were randomly assigned to undergo treatment with either a PFNA (observation group, n = 65) or an LPFP (control group, n = 65). Intraoperative blood loss, incision length, operative time, and time to fracture healing were determined in each group. At 1, 3, and 6 months after surgery, the Harris hip score was used to evaluate hip joint recovery. Coxa vara, incision infection, and internal fixation loosening were compared between the two groups. Results:Intraoperative blood loss in the observation group was less than that in the control group [(189.26 ± 48.15) mL vs. (96.47 ± 40.21) mL, t = -11.93, P < 0.001]. Incision length, operative time, and time to fracture healing in the observation group were significantly shorter than those in the control group [(4.03 ± 1.48) cm vs. (12.16 ± 1.55) cm, (72.13 ± 28.75) minutes vs. (120.34 ± 29.01) minutes, (9.89 ± 1.52) weeks vs. (13.63 ± 1.74) weeks, t = -30.59, -9.52, -13.05, all P < 0.001]. At 1 month after surgery, there was no significant difference in Harris hip score between the two groups ( t = 1.28, P > 0.05). At 3 and 6 months after surgery, the Harris hip score gradually increased in the control and observation groups ( F = 13.44, 8.26, both P < 0.001). At 3 and 6 months after surgery, Harris hip scores in the observation group were significantly higher than those in the control group [(85.17 ± 4.29) points vs. (79.50 ± 4.12) points, (95.30 ± 1.04) points vs. (87.69 ± 1.25) points, t = 7.69, 37.73, both P < 0.001]. The incidence of complications in the observation group was significantly lower than that in the control group [1.54% (1/65) vs. 10.77% (7/65), χ2 = 4.80, P = 0.029). Conclusion:Compared with LPFP, PFNA can effectively reduce intraoperative blood loss in older adult patients with femoral intertrochanteric fractures, accelerate the progress of fracture healing, promote the recovery of the hip joint, and has fewer complications. Therefore, PFNA is worthy of popularization.

11.
Journal of Environmental and Occupational Medicine ; (12): 559-564, 2023.
Artículo en Chino | WPRIM | ID: wpr-973647

RESUMEN

Background Steel workers are exposed to occupational hazardous factors such as dust, noise, and heat, and often work in shifts, making them prone to sleep disorders. Objective To explore potential influencing factors of sleep disorders among workers in a steel enterprise in Gansu Province, and provide a basis for reducing the risk of sleep disorders among them. Methods From January to March 2022, a self-made questionnaire combined with the Pittsburgh Sleep Quality Index (PSQI) were used to investigate the employees of a steel enterprise in Gansu Province. According to their PSQI scores, they were divided into a normal sleep group and a sleep disorder group. The general demographic variables of the two groups were balanced by 1∶1 propensity score matching (PSM). Multiple logistic regression was used to analyze the contributing factors of sleep disorders. Restricted cubic spline (RCS) model was used to analyze potential dose-response relationship between weekly working hours and sleep disorders. Results The prevalence of sleep disorders in the steel workers was 48.06% (6029/12544). After PSM, 5847 pairs were successfully matched, and the distributions of matched variables were well balanced between the two groups. The results of multiple logistic regression showed that hypertension (OR=1.39, 95%CI: 1.24, 1.56), diabetes mellitus (OR=1.34, 95%CI: 1.07, 1.66), three-shift system (OR=1.26, 95%CI: 1.12, 1.41), dust exposure (OR=1.14, 95%CI: 1.01, 1.29), noise exposure (OR=1.23, 95%CI: 1.09, 1.39), heat exposure (OR=1.16, 95%CI: 1.04, 1.29), and work injury (OR=1.22, 95%CI: 1.02, 1.46) increased the risk of sleep disorders. Compared with workers with < 10 years of service, those with 10-20 years (OR=1.31, 95%CI: 1.19, 1.44), 20-30 years (OR=1.34, 95%CI: 1.19, 1.52), and ≥30 years of service (OR=1.35, 95%CI: 1.19, 1.53) had a higher risk of sleep disorders. Compared with non-exercise workers, the risk of developing sleep disorders was lower in workers with occasional exercise (OR=0.61, 95%CI: 0.56, 0.66) and regular exercise (OR=0.55, 95%CI: 0.49, 0.62). The RCS model showed that the weekly working hours and sleep disorders in the steel workers showed a nonlinear dose-response relationship (P<0.05 for overall trend, P<0.05 for nonlinear test). The relationship between weekly working hours and sleep disorders showed a "U" shaped distribution, with a significant increase in the risk of sleep disorders when the weekly working hours exceeded 49 h. Conclusion The non-occupational influencing factors of sleep disorders of employees in the steel enterprise include hypertension, diabetes, physical exercise, and occupational influencing factors include length of service, weekly working hours, shifts, dust exposure, noise exposure, heat exposure, and work injuries. It is recommended to consider both occupational and non-occupational factors to formulate appropriate sleep disorder prevention and control measures for steel employees to reduce the risk of sleep disorders.

12.
Int. arch. otorhinolaryngol. (Impr.) ; 27(4): 694-698, 2023. tab
Artículo en Inglés | LILACS-Express | LILACS | ID: biblio-1528739

RESUMEN

Abstract Introduction Tonsillectomy is among the most common otolaryngological surgeries. Objective To evaluate and compare three tonsillectomy techniques: cold steel dissection (CSD), monopolar electrocautery (MEC), and coblation. Methods The present study retrospectively reviewed the medical records of patients who underwent tonsillectomy between January 2014 and January 2016. Postoperative visual analog scale (VAS) pain scores, analgesic use, surgical duration, time to return to normal activity, and postoperative bleeding status were noted. Results The CSD group had less analgesic use and shorter return to normal activity than the MEC group (p =0.037 and p < 0.001, respectively). The coblation group had lower VAS pain scores than the MEC group only at 1 hour to 4 hours postsurgery (p <0.016). The postoperative bleeding rate was similar in all groups (p = 0.096). Conclusion Cold steel dissection tonsillectomy is associated with less postoperative pain and shorter recovery than MEC. Coblation is better than MEC in terms of postoperative pain at 1 hour to 4 hours only, whereas CSD is associated with less postoperative pain than coblation at 2 days to 7 days.

13.
Pesqui. bras. odontopediatria clín. integr ; 23: e210155, 2023. tab, graf
Artículo en Inglés | LILACS, BBO | ID: biblio-1507020

RESUMEN

ABSTRACT Objective: To evaluate the mechanical properties of mini-implants (MIs) manufactured from stainless steel and compare them with conventional titanium-aluminum-vanadium alloy MIs. Material and Methods: The following groups were formed: G1 (n=24), 8×1.5 mm steel MIs; G2 (n=24), 12×2.0 mm steel MIs; and G3 (n=24), 10×1.5 mm titanium MIs. The 72 MIs were inserted in the infra zygomatic crest region of the maxilla and retromolar trigone in the jaw of 10 pigs. Pull-out, insertion torque, fracture and percussion tests were performed in order to measure the tensile strength, primary stability and fracture strength of MIs. A digital torque gauge was used to measure insertion and fracture torque, a universal mechanical testing machine was used for pull-out testing and a periotest device was used to measure the micromovement of MIs. For morphological and MI component evaluation, scanning electron microscopy (SEM) was performed. D'Agostino & Pearson, Kruskal-Wallis, and Dunn post-hoc and normality tests were used. Results: G2 insertion and fracture torques were significantly higher than G1 and G3 insertion and fracture torques (p<0.05). The pull-out and percussion tests presented similar values among the groups. SEM revealed that the fracture point was predominantly on the fourth thread for steel MIs (G1 and G2) and on the seventh thread for titanium-aluminum-vanadium MIs (G3). Conclusion: The mechanical properties of stainless steel MIs are superior to those of titanium-aluminum-vanadium alloy MIs.


Asunto(s)
Animales , Acero Inoxidable/química , Resistencia a la Tracción , Titanio , Métodos de Anclaje en Ortodoncia/instrumentación , Porcinos , Microscopía Electrónica de Rastreo/instrumentación , Estadísticas no Paramétricas , Resistencia Flexional , Pruebas Mecánicas
14.
Artículo | IMSEAR | ID: sea-216813

RESUMEN

Background and Aim of Study: Early childhood caries is a multifactorial disease process affecting children below 71 months of age and continues to be a global health problem. Stainless steel crowns (SSCs) are widely used and are very popular in pediatric dentistry due to its superiority and durability when compared with multisurface amalgam restorations. However, one of the major disadvantages with these crowns is the poor esthetics. Parents often request for a more esthetic alternative to the SSC. Zirconia crowns are one of the tooth-colored full crown restorations currently available for use in primary teeth. These are available as both preformed and custom-made crowns and show excellent esthetics. However, these require extensive tooth preparation with a subgingival finish lines, which would cause gingival trauma and bleeding during the preparation. The present study uses intraoral scanners for making the custom-made zirconia crowns, which will avoid the conventional impressions. Currently, there are no studies available in pediatric dentistry regarding CAD-CAM crowns. Hence, there is a need for the study. Aim: The aim of this study is to clinically evaluate the performance of preformed SSCs and custom-made zirconia crowns in primary molars. To elicit parental and patient satisfaction with respect to preformed SSCs and custom made zirconia crowns and to radiographically compare the interproximal bone height for 1 year. Methods: The patients were selected with purposive sampling. The tooth of interest was prepared according to the crown it would receive. The upper and the lower arch of the tooth receiving custom-made zirconia crown was scanned using an intraoral scanner. The crowns were cemented using Type 1 glass ionomer cement (GIC) (SSC) and resin modified GIC (custom-made zirconia crown). After the crown placement, the patient and the parent's satisfaction was scaled regarding the time taken, comfort, cost of crown, appearance of crown, etc., using a 5-point Likert scale. A baseline radiograph was taken after crown placement. The patient was recalled every 3 months till 1 year for evaluation (loss of retention, loss of proximal contact, gingival inflammation, opposing tooth wear, and marginal integrity). At the end of 1 year, radiographs were taken to check the interproximal bone. Results: After 1 year evaluation of custom-made zirconia crowns and preformed SSCs in primary molars, it was shown that both SSC and zirconia crowns showed good gingival scores but zirconia crown was better than SSC in improving the gingival health. SSCs showed better results with respect to the opposing tooth wear and marginal adaptability. Parents as well as patients preferred a tooth-colored crown as a treatment option. Conclusion: Custom-made zirconia crowns are comparable to the preformed SSCs and they show better gingival scores and excellent color match.

15.
Japanese Journal of Cardiovascular Surgery ; : 57-60, 2022.
Artículo en Japonés | WPRIM | ID: wpr-924539

RESUMEN

A 79-years-old female underwent total arch replacement for an aortic arch aneurysm. A postoperative CT scan showed no abnormalities on the anastomotic sites, including the supra-aortic neck vessels. However, 10 months after the operation, she visited our outpatient clinic to complain of left shoulder pain. A CT scan demonstrated complete occlusion of the left subclavian artery, and doppler echography detected a subclavian steal phenomenon. Eleven months after the operation, the patient was transferred to our hospital because of the transient loss of consciousness and progressive aphasia. MRI revealed hyperintensive lesions in the boundary area between the left temporal and occipital lobes, enlarged in a DWI (diffusion-weighted image) with time. Axillary-axillary bypass grafting was performed to suppress the progression of cerebral ischemia caused by a subclavian steal phenomenon. Aphasia seemed to be improved soon after the bypass and diminished on postoperative day 2. The hyperintensive area on DWI regressed, and no other lesion was found on a postoperative MRI. She was discharged without apparent sequelae, including aphasia. We report a successful case of revascularization for subclavian steal syndrome with aphasia.

16.
Chinese Journal of Medical Instrumentation ; (6): 312-317, 2022.
Artículo en Chino | WPRIM | ID: wpr-928911

RESUMEN

Stainless steel has been widely used in non-active surgical implantable medical device of cardiovascular, orthopedics, dental and ophthalmology. In this paper, we mainly focused on development of stainless steel, as well as the material-related standard evolution. We further summarized the recent advancement of stainless steel use in surgical implantable medical device. Insight and regulatory perspective has been further demonstrated.


Asunto(s)
Prótesis e Implantes , Acero Inoxidable
17.
CES odontol ; 34(1): 118-124, ene.-jun. 2021. tab, graf
Artículo en Inglés | LILACS-Express | LILACS | ID: biblio-1360266

RESUMEN

Abstract This article reviews the indications, objectives and step by step process of the Modified Hall Technique in the management of primary and permanent molars affected by severe enamel hypomineralization. Scientific based biological principles are discussed in order to provide relevant clinical information for Pediatric and General dentists in order to provide support for the safe use the technique in clinical practice.


Resumen En este artículo se revisan las indicaciones, objetivos y proceso paso a paso de la Técnica de Hall Modificada en el manejo de molares primarios y permanentes afectados por hipomineralización severa del esmalte. Los principios biológicos basados en la evidencia se discuten con el fin de proporcionar información clínica relevante para los odontólogos pediátricos y generales con el fin de proporcionar apoyo para el uso seguro de la técnica en la práctica clínica.


Resumo Neste artigo foram revisadas as indicações, objetivos e o passo a passo da Técnica de Hall Modificada para o manejo de molares decíduos e permanentes afetados pela hipomineralização severa do esmalte. Os princípios biológicos baseados na evidência são discutidos com o objetivo de proporcionar informações clínicas relevantes para odontopediatras e clínicos gerais, a fim de lhes fornecer apoio para o uso seguro da técnica na prática clínica.

18.
Acta odontol. latinoam ; 34(1): 18-26, Apr. 2021. graf
Artículo en Inglés | LILACS-Express | LILACS | ID: biblio-1284930

RESUMEN

ABSTRACT The aim of this study was to evaluate the possible association between the roughness of 5 brands of stainless steel endodontic files and their resistance to fracture due to cyclic fatigue. The study includedfive different brands of stainless steel endodontic files: SybroEndo Triple-Flex Files (Kerr, Glendora, USA), Ready Steel K-Flexofile (Dentsply Sirona, Ballaigues, Switzerland), Mani Flexile Files (Mani, Tochigi- Ken, Japan), FKG K-Files (FKG, La Chaux-de-Fonds, Switzerland) and Zipperer Flexicut Files (VDW, Munich, Germany). Twelve files per brand (total 60 files) were evaluated. File surface roughness over an area (Sa) was quantified using a focus variation microscope. Then the files were subject to a cyclical fatigue test to determine the number cycles to fracture due to fatigue and length of fractured fragment. Finally, fractographic analysis was performed using a scanning electron microscope. The electropolished Ready Steel K-Flexofile® files had the highest roughness according to Sa parameters, though they also had the highest resistance to fracture due to cyclic fatigue and the longest fractured fragment. Moderate positive correlation was found between fractured fragment length and roughness. The fractured surface showed characteristics of ductile fracture with cracks and plastic deformation. The electropolished stainless steel Ready Steel K-Flexofile® files werethe most resistant to fracture due to cyclic fatigue even though they had highest surface roughness.


RESUMEN El objetivo del presente estudio fue evaluar la posible asociación entre la rugosidad de 5 marcas de limas endodónticas de acero inoxidable y su resistencia a la fractura por fatiga cíclica. Se incluyeron cinco grupos diferentes de limas endo-dónticas de acero inoxidable: SybroEndo Triple-Flex Files (Kerr, Glendora, EE. UU.), Ready Steel K-Flexofile (Dentsply Sirona, Ballaigues, Suiza), Mani Flexile Files (Mani, Tochigi-Ken, Japón), FKG K-Files (FKG, La Chaux-de-Fonds, Suiza) y Zipperer Flexicut Files (VDW, Munich, Alemania); se evaluaron doce instrumentos por grupo para un total de 60 limas. Mediante un microscopio de variación focal se cuantificó la rugosidad superficial por área (Sa) de los instrumentos, posteriormente fueron sometidos a una prueba de fatiga cíclica donde se determinó el número de ciclos de fractura por fatiga y la longitud del fragmento fracturado. Finalmente, se realizó un análisis fractográfico mediante microscopía electrónica de barrido. Las limas Ready Steel K-Flexofile® con electropulido mostraron el mayor valor de rugosidad en los parámetros Sa; sin embargo, también tenían la mayor resistencia a la fractura por fatiga cíclica y la mayor longitud del fragmento fracturado del instrumento. Además, se encontró una correlación moderada positiva entre la longitud del fragmento fracturado y la rugosidad. La superficie fracturada mostró características de fractura dúctil con grietas y deformación plástica. Las limas Ready Steel K-Flexofile® fabricadas en acero inoxidable con electropulido, fueron más resistentes a la fractura por fatiga cíclica a pesar de tener la mayor rugosidad superficial.

19.
Eng. sanit. ambient ; 26(2): 201-210, Mar.-Apr. 2021. tab, graf
Artículo en Portugués | LILACS-Express | LILACS | ID: biblio-1249756

RESUMEN

RESUMO Considerado um poluente prioritário de reconhecida toxicidade e recalcitrância, o 2,4-dinitrofenol (2,4-DNF) presente em águas residuárias dificulta tratamentos convencionais, especialmente os de princípio biológico, como lagoas aeradas e sistema de lodos ativados. Em função de sua potencialidade de transformar a estrutura de poluentes em elementos de capacidade poluidora reduzida, os processos oxidativos avançados (POAs) representam atualmente uma alternativa para o tratamento de efluentes contaminados com compostos dessa natureza. A presente pesquisa teve como objetivo realizar estudos de degradação de 2,4-DNF em solução aquosa por meio de processos de oxidação avançada do tipo Fenton utilizando uma fonte não convencional de ferro na forma de um resíduo siderúrgico (carepa de aço). A condução de um delineamento experimental fundamentado em planejamento fatorial de experimentos revelou que as variáveis quantidade de peróxido de hidrogênio e de carepa influenciaram significativamente a degradação de 2,4-DNF, proporcionando, em condições otimizadas (20 g de carepa, 0,5 mL de H2O2 em pH 3), elevada eficiência na degradação tanto do composto modelo quanto de seus intermediários reacionais, tendo reduzido também a toxicidade aguda medida na forma de inibição de crescimento de E. coli. Ensaios adicionais sugeriram que os mecanismos reacionais pelos quais ocorre a degradação do 2,4-DNF são mediados tanto pela superfície das partículas de carepa quanto pelo ferro lixiviado, caracterizando o processo como uma combinação de oxidação homogênea e heterogênea. Finalmente, ensaios de reusabilidade e operação em reator de fluxo contínuo sugeriram significativa potencialidade do sistema carepa/H2O2.


ABSTRACT Considered a priority pollutant of recognized toxicity and recalcitrance, 2.4-dinitrophenol (2.4-DNP) present in wastewater hinders conventional treatments such as filtration, chemical coagulation, activated sludge system and activated carbon adsorption. Due to the potential of advanced oxidation processes (AOP) to transform the structure of pollutants into elements of reduced pollutant capacity, they presently represent an alternative for the treatment of effluents contaminated with these compounds. The present research aimed to study the degradation of 2.4-DNP in aqueous solution through advanced Fenton-type oxidation processes, using an unconventional source of iron in the form of a steel residue (steel waste). The conduction of an experimental design based on the factorial planning of experiments revealed that the variables hydrogen peroxide quantity and scale significantly influenced 2.4-DNF degradation, providing, under optimized conditions (20 g of steel waste, 0.5 mL of H2O2 at pH 3) high degradation efficiency of both the model compound and its reaction intermediates, as well as reducing acute toxicity, measured as E. coli growth inhibition. Further trials have suggested that the reaction mechanisms by which 2.4-DNF degradation occurs are mediated by both the surface of steel waste particles and the leached iron, characterizing the process as a combination of homogeneous and heterogeneous oxidation. Finally, reusability and continuous flow reactor operation tests suggested the significant potential of the steel waste/ H2O2 system.

20.
Artículo | IMSEAR | ID: sea-216741

RESUMEN

Introduction: Different sizes of crowns may be tried on children since there is no universal crown size because of distinctions in tooth morphology from one child to other. During the process of trial and error, the crown gets contaminated which needs to be sterilized for reuse of crown. This study was carried out to evaluate the physical–mechanical outcome after the sterilization and disinfection of pediatric preformed crowns. Materials and Methods: In total, sixty crowns consisted of 20 each, stainless steel crowns (SSCs) (3M ESPE), preveneered stainless steel (Kinder Krowns), and Zirconia crowns (Kinder Krowns) which were divided into four groups. G1 in which crowns did not undergo any sterilization, G2 consisted of fast sterilization, similarly G3 was slow sterilization, and G4 underwent chemical disinfection using Korsolex Plus for 15 min. Following sterilization, all the crown samples were observed under a stereomicroscope at ×200 magnification and assessed for color change, crazing, dimensional stability, and fracturing. Post hoc Tukey test and two-way ANOVA were performed for comparison between types of crowns and sterilization methods, with a significance level was set at P < 0.05. Results: There was no color change or fracturing following sterilization among crowns in any of the groups. Highest crazing was noted in stainless steel and the least in Zirconia crowns. Preveneered stainless steel was the most dimensionally stable and SSCs was the least. Conclusion: No color changes and fracture were noted in any type of crowns. Preveneered stainless steel was most dimensionally stable followed by Zirconia and SSCs. Maximum crazing was seen in SSCs and nil in Zirconia.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA