Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Añadir filtros








Intervalo de año
1.
Chinese Journal of Radiological Health ; (6): 569-572, 2023.
Artículo en Chino | WPRIM | ID: wpr-1003566

RESUMEN

Objective To preliminarily study the effectiveness and safety of stereotactic ablative brachytherapy (SABT) for lung metastases from cervical cancer. Methods We analyzed the clinical data of 18 patients with cervical cancer with lung metastasis treated with SABT to compare gross tumor volume (VGTV) and squamous cell carcinoma (SCC) antigen before and after SABT. The clinical benefit rate (CBR) and adverse reactions were recorded. Results After SABT treatment, there were significant decreases in VGTV (t=1.708, P<0.05) and the SCC antigen level (t=1.704, P<0.05). CBR reached 94.4%. Adverse reactions of grades 3-4 did not occur in any patient. Fourteen patients had mild complications, including 1 case of bloody sputum and 1 case of a small pneumothorax. Ten cases developed mild radiation-induced lung injury, with grade 2 radiation pneumonitis in 4 cases. The Karnofsky performance status score and needle depth were not associated with the occurrence of adverse reactions, while the radius of GTV and interstitial lung disease were associated with the occurrence of adverse reactions. Conclusion SABT is a safe and effective alternative to the treatment of lung metastases from cervical cancer.

2.
Cancer Research on Prevention and Treatment ; (12): 474-478, 2021.
Artículo en Chino | WPRIM | ID: wpr-988569

RESUMEN

Objective To explore the dose of template-assisted 192Ir source hypofractionated stereotactic brachytherapy (SABT) for peripheral lung cancer. Methods We retrospectively analyzed the dose parameters of GTV and OARs of 28 peripheral lung cancer patients treated with template-assisted 192Ir-source hypofractionated SABT, and compared the dose parameters between SABT with virtual SBRT. Results The Dmean and V150 for the GTV in the SABT plan were significantly higher than those in the SBRT plan (all P < 0.01). For OARs, all dosimetric parameters in the SABT plan were significantly lower than those in the SBRT plan (all P < 0.01), except for the D1000cm3 and D1500cm3 for the lung (P > 0.05). Conclusion Template-assisted 192Ir source hypofractionated SABT ensures high dose in the gross tumor volume and reduces the dose in organs at risk in the treatment of peripheral lung cancer.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA