Chinese Journal of Experimental Ophthalmology ; (12): 292-296, 2019.
Artículo en Chino | WPRIM | ID: wpr-744033

RESUMEN

Objective To compare the agreement of axial length (AL),anterior chamber depth (ACD) and keratometry measured by IOLMaster 500 with IOLMaster 700 in cataract eyes with high myopia.Methods A cross-sectional study was performed.One hundred and fifty-two eyes of 87 cataract patients with high myopia were included from September to October 2017 in Beijing Tongren Hospital.The best corrected visual acuity (BCVA) was 0.05-1.0,and the refraction power was-6.25--21.00 D,with an average power of (-13.625 ± 7.375) D.A L,ACD and keratometry (Kf,Ks) were measured by IOLMaster 700 and IOLMaster 500 respectively for all the eyes.The eyes were assigned to AL>26-≤28 mm group,AL>28-<30 mm group and AL≥30 mm according to the results of IOLMaster 500.The measured differences between two devices were assessed using paired samples t-test,and the measured consistency of the two devices was evaluated using Bland-Altman agreement analysis.This study protocol was approved by Ethics Committee of Beijing Tongren Hospital and complied with Declaration of Helsinki.Results There were no significant differences in the AL and Kf measured by the two devices in all the three groups (all at P>0.05).Both ACD and Ks values measured by IOLMaster 700 were lower than those by IOLMaster 500 (both at P<0.05),which were clinically acceptable.The percentage beyond 95% agreement limit between IOLMaster 700 and IOLMaster 500 were 4.10%,2.17% and 3.03% for AL differences and 4.10%,4.34% 和 3.03% for Kf difference in the three groups.Significant differences were found in ACD and Ks between IOLMaster 700 and IOLMaster 500 at a clinically acceptable level (both at P<0.05),and Bland-Altamn agreement analysis showed that the percentage beyond 95% agreement limit between IOLMaster 700 and IOLMaster 500 were 4.10%,4.34% and 3.03% for both ACD and Ks differences in the three groups.Conclusions There is a good agreement in AL,ACD,Kf and Ks measured by IOLMaster 700 with IOLMaster 500 and is clinically interchangeable in cataract eyes with high myopia.However,IOLMaster 700 is better because it can provide the OCT image of macula.

2.
Rev. bras. oftalmol ; 73(3): 135-137, May-Jun/2014. graf
Artículo en Inglés | LILACS | ID: lil-727179

RESUMEN

Purpose: Register and compare anatomical changes, structural and quantitative found in optical coherence tomography Stratus and Topcon 3D in chronic users of chloroquine. Methods: Five patients were diagnosed with toxic "bull's eye" maculopathy was submitted to macular optical coherence tomography examination (Stratus and Topcon 3D). Results: Both tools demonstrated an increase reflectivity of choriocapillaris unit just foveal retinal pigment epithelium atrophy. However, Topcon 3D provided to all patients better description of the line corresponding to the transition between inner and outer segments of photoreceptors. Using the possibility of assembling threedimensional images and subtraction selective retinal layers, we found a lesion with a target that reflects the greater thickness of retinal pigment epithelium in central and parafoveal region that is matched to preserve macular photoreceptors. Conclusion: it was observed better resolution and faster image capture by Topcon 3D than Stratus OCT, that provided more detailed analysis of the line corresponding to transition between outer and inner segment of photoreceptors in macular region. With Topcon 3D, it was possible to evaluate soundly the thickness of retinal pigment epithelium in central and parafoveal region that caused an increase reflectivity of choriocapillaris creating a image with a target unpublished before. .


Objetivo: Comparar e registrar as alterações quantitativas e qualitavivas na tomografia de coerência óptica nos pacientes com uso prolongado de cloroquina. Métodos: Avaliaram-se cinco pacientes com diagnóstico de bull’s eye no exame de tomografia de coerência óptica macular com dois modelos de aparelhos: Stratus e Topcon 3D. Resultados: Ambos aparelhos registraram aumento da refletividade coriocapilar foveal provocada pela atrofia do epitélio pigmentar da retina. Somente o Topcon 3D permitiu melhor visibilização da linha de transição entre o segmento interno e externo dos fotorreceptores. Este aparelho também permitiu a formação de imagens tridimensionais e subtração das camadas retinianas, com registro da diminuição da espessura do epitélio pigmentado da retina na região central e parafoveal macular. Conclusão: Foi possível observar a captação mais rápida e com melhor resolução das imagens geradas pelo Topcon 3D. A diminuição da espessura do epitélio pigmentado da retina, provocando o aumento da refletividade coriocapilar, com a formação de uma imagem linear circular cincundando a fóvea, foi mais detalhado pelos cortes realizados no Topcon 3D. .


Asunto(s)
Humanos , Enfermedades de la Retina/inducido químicamente , Enfermedades de la Retina/diagnóstico por imagen , Cloroquina/efectos adversos , Tomografía de Coherencia Óptica/métodos , Degeneración Macular/inducido químicamente , Degeneración Macular/diagnóstico por imagen , Retina/efectos de los fármacos , Retina/patología , Retina/diagnóstico por imagen , Cloroquina/administración & dosificación