Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
1.
Artículo | IMSEAR | ID: sea-204209

RESUMEN

Background: Neonatal hyperbilirubinemia, though benign in 80% cases, can lead to kernicterus if not diagnosed and treated early. The golden method of estimation is measuring serum bilirubin levels. Both Kramer's scale and Transcutaneous bilirubinometer are non -invasive methods. Its high time the pediatricians choose an ideal non-invasive and reliable method to detect hyperbilirubinemia. Objective of this study is to find out which has a better correlation with serum bilirubin - transcutaneous bilirubinometer reading (TcB) or Kramer's scale.Methods: The study was conducted in a tertiary newborn center from November 2014 to June 2016. The inclusion criteria included all babies above 34 weeks gestation and exclusion criteria included babies with established direct hyperbilirubinemia, neonatal septicemia, major congenital/ gastrointestinal malformations and those on phototherapy. The sample size was 450 and the correlation was analyzed using ROC curves and plots of agreement was done using Bland Altman charts.Results: The incidence of significant Hyperbilirubinemia is 12%. Transcutaneous bilirubin level had a better correlation and prediction level compared to Kramer at both 24 hours and 48 hours. Bland Altman analysis showed that transcutaneous values were closer to the total serum bilirubin level compared to Kramer values.Conclusion: Transcutaneous bilirubinometry is a better and more ideal choice to replace serum bilirubin levels. In settings where TcB is not feasible, it's always best to screen for jaundice using Kramer's scale rather than estimating serum bilirubin values in all babies. In babies where TcB levels are above the cut off range, it's better to do serum bilirubin levels.

2.
Indian Pediatr ; 2009 May; 46(5): 405-408
Artículo en Inglés | IMSEAR | ID: sea-144032

RESUMEN

This prospective study was conducted to evaluate the accuracy of transcutaneous bilirubinometry in preterm newborns less than 32 weeks of gestation. Serum bilirubin values measured by direct spectrophotometry were considered as standard, the range was 2.2-12.5 mg/dL. 32 jaundiced infants of less than 32 weeks of gestation without phototherapy, including 10 ELBW neonates, were enrolled. Close correlation (R=0.933) existed between total serum bilirubin and transcutaneous bilirubin values measured over sternum.


Asunto(s)
Recién Nacido , Hiperbilirrubinemia Neonatal/diagnóstico , Hiperbilirrubinemia Neonatal/terapia , Tamizaje Neonatal , Bilirrubina/sangre , Recien Nacido Prematuro , Técnicas de Laboratorio Clínico/métodos , Hiperbilirrubinemia Neonatal/sangre , Recolección de Muestras de Sangre/instrumentación , Recien Nacido con Peso al Nacer Extremadamente Bajo , Recién Nacido , Tamizaje Neonatal/instrumentación , Tamizaje Neonatal/métodos , Espectrofotometría/instrumentación , Humanos
3.
Artículo en Inglés | IMSEAR | ID: sea-137934

RESUMEN

Transcutaneous bilirubinometry (TcB) is a new diagnostic tool for neonatal hyperbilirubinemia. It can be used as a screening tool to identify full-term infants who require serum bilirubin determination. In Thai infants, it yields a positive prediction with serum bilirubin. The correlation coefficient was 0.8. The best correlation was obtained when serum bilirubin was over 15 mg/dl. The postnatal age of the infant affects the accuracy of TcB measured at the forehead. We recommend TcB be measured at the forehead during the first three days of life.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA