Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Añadir filtros








Intervalo de año
1.
Journal of Practical Radiology ; (12): 982-984,993, 2015.
Artículo en Chino | WPRIM | ID: wpr-600228

RESUMEN

Objective To estimate the application value of dual-source CT on preoperational evaluating new type of three branches aortic arch covered stent graft implantation on DeBakey type I aortic dissection.Methods 20 cases with DeBakey type I aortic dissec-tion prepared to performe three branches aortic arch covered stent graft implantation were reviewed,and their CT findings were ana-lyzed in order to evaluate the guiding value for operation.Results The location and size of entries were determined and the diameter of aortic arch and three branchesas well as the intervals of three branches were also measured by dual-source CT.Furthermore, blood-supply for main vessel and complications related with covered stent were further analyzed prior to operation.The surgical pro-tocols were designed according to preoperational CT findings.Among all cases,13 cases were fit for new type of three branches aor-tic arch covered stent graft implantation.While the rest cases (N=7)were adopted other operations due to non-fitted indications. Conclusion Dual-source CT is of significance for preoperational evaluating new type of three branches aortic arch covered stent graft implantation on DeBakey type I aortic dissection.

2.
The Korean Journal of Thoracic and Cardiovascular Surgery ; : 336-339, 1997.
Artículo en Coreano | WPRIM | ID: wpr-41032

RESUMEN

The surgical treatment of diseases of thoracic aorta has had much better success rate in recent years compaired to the past. Aortic aneurysms or dissections that extend along the entire thoracic aorta are usually approached in two or three stages. Recently we successfully performed one-stage aortic replacement from the aortic root to the abdominal aorta in chronic DeBakey type I dissection. A 25 year-old man who had dyspnea on exertion (NYHA Fc II) and a Marfanoid feature was operated under the diagnosis of chronic type I dissection with severe aortic regurgitation. At operation, a huge ascending aorta with two intimal tearings was seen and the blood supply of intercostal arteries and right renal artery was done from the false lumen. Modified Bentall operation with total aortic replacement was done successfully, and the patient is being followed-up without major complications.


Asunto(s)
Adulto , Humanos , Aorta , Aorta Abdominal , Aorta Torácica , Aneurisma de la Aorta , Insuficiencia de la Válvula Aórtica , Arterias , Diagnóstico , Disnea , Arteria Renal
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA