Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Añadir filtros








Intervalo de año
1.
Braz. j. pharm. sci ; 51(1): 221-231, Jan-Mar/2015. tab, graf
Artículo en Inglés | LILACS | ID: lil-751366

RESUMEN

This study describes the development and evaluation of stability-indicating liquid chromatographic (LC) and UV spectrophotometric methods for the quantification of ciprofibrate (CPF) in tablets and capsules. Isocratic LC separation was achieved on a RP18 column using a mobile phase of o-phosphoric acid (0.1% v/v), adjusted to pH 3.0 with triethylamine (10% v/v) and acetonitrile (35:65 v/v), with a flow rate of 1.0 mL min-1. Detection was achieved with a photodiode array detector at 233 nm. For the spectrophotometric analysis, ethanol and water were used as the solvent and a wavelength of 233 nm was selected for the detection. The methods were validated according to International Conference on Harmonization (ICH) guidelines for validating analytical procedures. Statistical analysis showed no significant difference between the results obtained by the two methods. The proposed methods were successfully applied to the CPF quality-control analysis of tablets and capsules.


Este estudo descreve o desenvolvimento e avaliação de método indicativo da estabilidade por cromatografia líquida (LC) e método por espectrofotometria UV para quantificação de ciprofibrato (CPF) em comprimidos e cápsulas. No método por cromatografia líquida as análises foram realizadas isocraticamente em coluna de fase reversa C18, utilizando fase móvel composta por ácido o-fosfórico (0.1% v/v) pH 3.0, ajustado com trietilamina (10% v/v), e acetonitrila (35:65 v/v), com fluxo de 1,0 mL min-1. A detecção foi realizada em detector de arranjo de diodos a 233 nm. Na análise espectrofotométrica, etanol e água foram utilizados como solventes e o comprimento de onda de 233 nm foi selecionado para a detecção do fármaco. Os métodos foram validados de acordo com as diretrizes do International Conference on Harmonization (ICH). A análise estatística não mostrou diferença significativa entre os resultados obtidos pelos dois métodos. Os métodos foram aplicados com sucesso para análises de controle de qualidade do ciprofibrato em comprimidos e cápsulas.


Asunto(s)
Comprimidos/farmacocinética , Cromatografía Liquida/métodos , Espectrofotometría Ultravioleta/clasificación , Cápsulas/farmacocinética , /análisis , Estabilidad de Medicamentos
2.
Braz. j. pharm. sci ; 51(1): 183-191, Jan-Mar/2015. tab, graf
Artículo en Inglés | LILACS | ID: lil-751370

RESUMEN

The aim of this study was to develop and validate a UV spectrophotometric method for determination of LPSF/AC04 from inclusion complex and encapsulated into liposomes. The validation parameters were determined according to the International Conference on Harmonisation (ICH) and National Health Surveillance Agency (ANVISA) guidelines. LPSF/AC04 was determined at 250 nm in methanol by a UV spectrophotometric method, exhibiting linearity in the range from 0.3 to 2 µg.mL−1 (Absorbance=0.18068 x [LPSF/AC04 µg.mL-1] + 0.00348), (r2=0.9995). The limits of detection and quantification were 0.047µg.mL−1 and 0.143µg.mL−1, respectively. The method was accurate, precise, reproducible and robust since all the samples analyzed had coefficient of variation of less than 5% and no statistically significant difference between theoretical and practical concentrations was detected. Thus, a rapid, simple, low cost and sensitive spectrophotometric method was developed and validated for determining the content of inclusion complex and liposomes containing LPSF/AC04.


O objetivo deste estudo foi desenvolver e validar um método espectrofotométrico para determinação do LPSF/AC04 em complexo de inclusão e encapsulado em lipossomas. Os parâmetros de validação foram determinados de acordo com o International Conference on Harmonisation (ICH) e Agência Nacional de Vigilância Sanitária (ANVISA). OLPSF/AC04 foi determinado a 250 nm em metanol pelo método espectrofotométrico UV, que apresenta linearidade na faixa de 0,3 a 2 µg/mL (Absorbância = 0,18068 x [LPSF/AC04 µg/mL] + 0,00348), (r2 = 0,9995). Os limites de detecção e quantificação foi 0,047 µg/mL e 0,143 µg/mL, respectivamente. O método foi exato, preciso, reprodutível e robusto e todas as amostras analisadas apresentaram coeficiente de variação menor que 5% e não houve diferença estatisticamente significante entre a concentração teórica e a prática. Assim, um método espectrofotométrico rápido, simples, sensível e de baixo custo foi desenvolvido e validado para determinar o conteúdo do LPSF/AC04 em complexos de inclusão e encapsulados em lipossomas.


Asunto(s)
Espectrofotometría Ultravioleta/métodos , Estudio de Validación , Liposomas/farmacocinética , /análisis
3.
Braz. j. pharm. sci ; 50(3): 457-465, Jul-Sep/2014. tab, graf
Artículo en Inglés | LILACS | ID: lil-728704

RESUMEN

New, simple and cost effective UV-spectrophotometric method was developed for the estimation of orbifloxacin in pharmaceutical formulation. Orbifloxacin was estimated at 290 nm in 0.5 M hydrochloric acid. Linearity range was found to be 1.0-6.0 μg mL-1. The method was tested and validated for various parameters according to main guidelines. The proposed method was successfully applied for the determination of orbifloxacin in tablets. The results demonstrated that the procedure is accurate, precise and reproducible, while being simple, economical and less time consuming. It can be suitably applied for the estimation of orbifloxacin in routine quality control and dissolution studies.


Um método espectrofotométrico novo, simples e de baixo custo foi desenvolvido para a determinação de orbifloxacino em formulação farmacêutica. O orbifloxacino foi determinado em 290 nm utilizando ácido clorídrico 0,5 M como solvente. O intervalo de linearidade usado foi de 1,0 a 6,0 μg mL-1. O método foi testado e validado em vários parâmetros de acordo com os principais guias. O método proposto foi aplicado com sucesso para a determinação de orbifloxacino em comprimidos. Os resultados demonstraram que este procedimento é exato, preciso e reprodutível, ao mesmo tempo em que é simples, barato e de mais rápida execução e pode ser adequadamente aplicado para a determinação de orbifloxacino na rotina do controle de qualidade e em estudos de dissolução de comprimidos contendo este fármaco.


Asunto(s)
Espectrofotometría Ultravioleta/métodos , Estudio de Validación , Antibacterianos/análisis , Química Farmacéutica , Disolución
SELECCIÓN DE REFERENCIAS