Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
Arq. bras. oftalmol ; 84(2): 140-148, Mar,-Apr. 2021. tab, graf
Artículo en Inglés | LILACS | ID: biblio-1153128

RESUMEN

ABSTRACT Purpose: To determine visual impairment due to optic pathway tumors in children unable to perform recognition acuity tests. Methods: Grating visual acuity scores, in logMAR, were obtained by sweep visually evoked potentials (SVEP) in children with optic pathway tumors. The binocular grating visual acuity deficit was calculated by comparison with age-based norms and then assigned to categories of visual impairment as mild (from 0.10 to 0.39 logMAR), moderate (from 0.40 to 0.79 logMAR), or severe (≥0.80 logMAR). Interocular differences were calculated by subtraction and considered increased if >0.10 logMAR. Results: The participants were 25 children (13 boys; mean ± SD age, 35.1 ± 25.9 months; median age, 32.0 months) with optic pathway tumors (24 gliomas and 1 embryonal tumor), mostly located at the hypothalamic-chiasmatic transition (n=21; 84.0%) with visual abnormalities reported by parents (n=17; 68.0%). The mean grating acuity deficit was 0.60 ± 0.36 logMAR (median, 0.56 logMAR). Visual impairment was detected in all cases and was classified as mild in 10 (40.0%), moderate in 8 (32.0%), and severe in 7 (28.0%) children, along with increased interocular differences (>0.1 logMAR) (n=16; 64.0%). The remarkable ophthalmological abnormalities were nystagmus (n=17; 68.0%), optic disc cupping and/or pallor (n=13; 52.0%), strabismus (n=12; 48.0%), and poor visual behavior (n=9; 36.0%). Conclusion: In children with optic pathway tumors who were unable to perform recognition acuity tests, it was possible to quantify visual impairment by sweep-visually evoked potentials and to evaluate interocular differences in acuity. The severity of age-based grating visual acuity deficit and interocular differences was in accordance with ophthalmological abnormalities and neuroimaging results. Grating visual acuity deficit is useful for characterizing visual status in children with optic pathway tumors and for supporting neuro-oncologic management.(AU)


RESUMO Objetivo: Determinar o grau de deficiência visual em crianças com tumores da via óptica incapazes de informar a acuidade visual de reconhecimento. Método: A acuidade visual de grades, em logMAR, foi estimada por potenciais visuais evocados de varredura em crianças com tumores das vias ópticas. O déficit da acuidade visual de grades binocular foi calculado em relação ao valor mediano normativo esperado para a idade e a deficiência visual, classificada como leve (0,10 a 0,39 logMAR), moderada (0,40 a 0,79 logMAR) ou grave (≥0,80 logMAR). Diferenças inter-oculares foram calculadas por subtração e consideradas aumentadas se >0,10 logMAR. Resultados: Foram avaliadas 25 crianças (13 meninos; média de idade ± DP=35,1± 25,9 meses; mediana=32,0 meses) com tumores da via óptica (24 gliomas e 1 tumor embrionário) localizados particularmente na transição hipotalâmico-quiasmática (n=21; 84,0%) e com anormalidades visuais detectadas pelos pais (n=17; 68,0%). A média do déficit da acuidade de grades foi 0,60 ± 0,36 logMAR (mediana=0,56 logMAR). Observou-se deficiência visual leve em 10 (40,0%), moderada em 8 (32,0%) e grave em 7 (28,0%), além de aumento da diferença interocular da acuidade visual (n=16; 64,0%). As principais alterações oftalmológicas encontradas foram: nistagmo (n=17; 68,0%), aumento da escavação do disco óptico e/ou palidez (n=13; 52,0%), estrabismo (n=12; 48,0%) e comportamento visual pobre (n=9; 36,0%). Conclusão: Em crianças com tumor da via óptica e incapazes de responder aos testes de acuidade visual de reconhecimento, foi possível quantificar deficiência visual por meio dos potenciais visuais evocados de varredura e avaliar a diferença interocular da acuidade visual de grades. A gravidade do déficit da acuidade visual de grades relacionado à idade e a diferença interocular da acuidade visual de grades foram congruentes com alterações oftalmológicas e neuroimagem. O déficit da acuidade visual de grades foi útil à caracterização do estado visual em crianças com tumores da via óptica e ao embasamento da assistência neuro-oncológica.(AU)


Asunto(s)
Humanos , Niño , Vías Visuales/patología , Agudeza Visual , Glioma del Nervio Óptico/patología , Trastornos de la Visión/etiología , Potenciales Evocados Visuales
2.
Arq. neuropsiquiatr ; 71(7): 437-441, July/2013. tab, graf
Artículo en Inglés | LILACS | ID: lil-679165

RESUMEN

Objective It was to investigate visual field (VF) abnormalities in a group of multiple sclerosis (MS) patients in the remission phase and the presence of magnetic resonance imaging (MRI) lesions in the optic radiations. Methods VF was assessed in 60 participants (age range 20-51 years): 35 relapsing-remitting MS patients [20 optic neuritis (+), 15 optic neuritis (-)] and 25 controls. MRI (3-Tesla) was obtained in all patients. Results Visual parameters were abnormal in MS patients as compared to controls. The majority of VF defects were diffuse. All patients except one had posterior visual pathways lesions. No significant difference in lesion number, length and distribution was noted between patients with and without history of optic neuritis. One patient presented homonymous hemianopsia. Conclusion Posterior visual pathway abnormalities were found in most MS patients despite history of previous optic neuritis. .


Objetivo Foi analisar o campo visual (CV) de um grupo de pacientes com esclerose múltipla (EM) na fase remissiva e a presença de lesões nas imagens de ressonância magnética (MRI) na radiação óptica. Método O CV foi estudado em 60 participantes (faixa etária de 20-51 anos): 35 pacientes EM remitente-recorrente: [20 neurite óptica (+), 15 neurite óptica (-)] e 25 controles. Foram obtidas MRI (3-Tesla) de todos os pacientes. Resultados Havia alterações visuais nos pacientes com EM quando comparados aos controles. A maioria apresentava defeitos difusos de CV. Todos os pacientes, à exceção de um, apresentaram lesões nas vias visuais posteriores. Não foi observada diferença significativa quanto a número, extensão e distribuição das lesões entre os pacientes com e sem história de neurite óptica. Um paciente apresentou hemianopsia homônima. Conclusão Anormalidades nas via visuais posteriores foram encontradas na maior parte dos pacientes com EM independentemente da história de neurite óptica. .


Asunto(s)
Adulto , Femenino , Humanos , Masculino , Persona de Mediana Edad , Adulto Joven , Esclerosis Múltiple/fisiopatología , Neuritis Óptica/fisiopatología , Trastornos de la Visión/fisiopatología , Vías Visuales/fisiopatología , Estudios de Casos y Controles , Imagen por Resonancia Magnética , Esclerosis Múltiple Recurrente-Remitente/fisiopatología , Estadísticas no Paramétricas , Agudeza Visual , Pruebas del Campo Visual
3.
Arq. bras. oftalmol ; 76(2): 85-89, mar.-abr. 2013. ilus, tab
Artículo en Inglés | LILACS | ID: lil-678172

RESUMEN

BACKGROUND: Visual processing deficits have been reported for patients with schizophrenia. Previous studies demonstrated differences in early-stage processing of schizophrenics, although the nature, extent, and localization of the disturbance are unknown. The magnocellular and parvocellular visual pathways are associated with transient and sustained channels, but their respective contributions to schizophrenia-related visual deficits remains controversial. PURPOSE: The aim of this study was to evaluate magnocellular dysfunction in schizophrenia using frequency doubling technology. METHODS: Thirty-one patients with schizophrenia and 34 healthy volunteers were examined. Frequency doubling technology testing was performed in one session, consisting of a 15-minute screening strategy followed by the C-20 program for frequency doubling technology. RESULTS: Schizophrenic patients showed lower global mean sensitivity (30,97 ± 2,25 dB) compared with controls (32,17 ± 3,08 dB), p<0.009. Although there was no difference in the delta sensitivity of hemispheres, there was a difference in sensitivity analysis of the fibers crossing the optic chiasm, with lower mean sensitivity in the patient group (28,80 dB) versus controls (30,66 dB). The difference was higher in fibers that do not cross the optic chiasm, with lower mean sensitivity in patients (27,61 dB) versus controls (30,26 dB), p<0.005. CONCLUSIONS: Our results suggest that there are differences between global sensitivity and fiber sensitivity measured by frequency doubling technology. The different sensitivity of fibers that do not cross the optic chiasm is consistent with most current etiological hypotheses for schizophrenia. The decreased sensitivity responses in the optic radiations may significantly contribute to research assessing early-stage visual processing deficits for patients with schizophrenia.


HISTÓRICO: Déficits de processamento visual foram relatados em pacientes com esquizofrenia. Estudos anteriores demonstraram diferenças no estágio inicial de processamento de esquizofrênicos, embora a natureza, extensão e localização do distúrbio são desconhecidas. As vias magnocelulares e parvocelular visuais são associados com canais transitórios e sustentado, mas suas respectivas contribuições para a esquizofrenia relacionados com déficits visuais permanece controverso. OBJETIVO: Avaliar a disfunção magnocelular na esquizofrenia usando a tecnologia de frequência dupla. MÉTODOS: Trinta e um pacientes com esquizofrenia e 34 voluntários saudáveis ​​foram examinados. Tecnologia de frequência dupla foi realizada em uma sessão, consistindo de uma estratégia de rastreio de 15 minutos, seguido do programa de C-20 para tecnologia de frequência dupla. RESULTADOS: Os pacientes esquizofrênicos apresentaram sensibilidade média inferior global (30,97 ± 2,25 dB), em comparação com os controles (32,17 ± 3,08 dB), p<0,009. Embora não tenha ocorrido diferença na sensibilidade do delta de hemisférios, houve uma diferença na análise de sensibilidade das fibras que atravessam a quiasma, com menor sensibilidade média no grupo de pacientes (28,80 dB) versus controlos (30,66 dB). A diferença foi maior em fibras que não cruzam o quiasma óptico, com menor sensibilidade média em pacientes (27,61 dB) versus controles (30,26 dB), p<0,005. CONCLUSÕES: Nossos resultados sugerem que há diferenças entre a sensibilidade global e sensibilidade da fibra medida pela tecnologia de frequência dupla. A sensibilidade diferente de fibras que não cruzam o quiasma óptico é compatível com a maioria das atuais hipóteses etiológicas para a esquizofrenia. As respostas diminuição da sensibilidade nas radiações ópticas podem contribuir significativamente para pesquisar a avaliação em estágio inicial déficits de processamento visual em pacientes com esquizofrenia.


Asunto(s)
Adulto , Femenino , Humanos , Masculino , Cuerpos Geniculados/fisiopatología , Esquizofrenia/fisiopatología , Pruebas del Campo Visual/métodos , Vías Visuales/fisiopatología , Percepción Visual/fisiología , Estudios de Casos y Controles , Sensibilidad de Contraste/fisiología , Esquizofrenia/complicaciones
4.
Arq. bras. oftalmol ; 74(3): 222-226, May-June 2011. ilus
Artículo en Inglés | LILACS | ID: lil-598321

RESUMEN

The pattern electroretinogram is an electrophysiological test that assesses the function of inner retinal layers, particularly the ganglion cells layer of retina, using a reversing checkerboard or grating pattern that produces no change in average luminance over time. The normal pattern electroretinogram is composed of a proeminent positive component (P50) and a large later negative component (N95). Since structural damage that compromises the retinal ganglion cell layer can lead to pattern electroretinogram changes, particularly in the N95 amplitude, the test can be useful in the treatment of a number of anterior visual pathway diseases. In this article, we review the methods for recording pattern electroretinogram and its usefulness in the diagnosis and management of diseases including inflammatory, hereditary, ischemic and compressive lesions of the anterior visual pathway.


O eletroretinograma de padrão reverso é um teste eletrofisiológico que avalia a função das camadas internas da retina, especialmente a camada de células ganglionares, através de um estímulo em xadrez ou em barras que não apresenta variação na luminância do estímulo. É composto de um componente positivo (P50) e um componente negativo (N95) tardio. Uma vez que lesões estruturais às células ganglionares da reitna podem levar a alterações no eletroretinograma de padrão reverso, especialmente na amplitude da onda N95, o teste pode ser útil no tratamento de várias doenças da via óptica anterior. Neste artigo revisamos os métodos de obtenção do eletroretinograma de padrão reverso e a sua utilidade no diagnóstico e acompanhamento de doenças incluindo lesões inflamatórias, hereditárias, isquemicas e compressivas na via óptica anterior.


Asunto(s)
Humanos , Electrorretinografía/métodos , Enfermedades del Nervio Óptico/diagnóstico , Vías Visuales/fisiopatología , Enfermedades del Nervio Óptico/fisiopatología
5.
Rev. bras. oftalmol ; 68(1): 48-52, Jan.-Feb. 2009. ilus, graf
Artículo en Inglés | LILACS | ID: lil-508925

RESUMEN

PURPOSE: To report abnormalities of retinal nerve fiber layer (RNFL) thickness using Stratus - optical coherence tomography (OCT) in two patients with optic tract lesions. METHODS: Two patients with long standing homonymous hemianopia from optic tract lesions were submitted to a complete neuro-ophthalmic evaluation and to Stratus -optical coherence tomography examination. RESULTS: Both patients revealed diffuse loss of the RNFL at Stratus - OCT in both eyes. In the eyes with the temporal hemianopia, RFNL loss was diffuse but predominantly in the nasal and temporal areas of the optic disc, the classic pattern of band atrophy of the optic nerve. In the eyes with nasal hemianopia RNFL loss could be documented in the superior and inferior quadrants of the optic disc. RNFL loss correlated well with visual field loss and the expected pattern of RNFL loss in optic tract lesions. CONCLUSION: Stratus-Optical coherence tomography can provide useful information in the diagnosis of optic tract lesions by identifying the characteristic pattern of RNFL loss that occurs in both eyes in this condition.


OBJETIVO: Relatar alterações na camada de fibras nervosas retiniana (CFNR) com o uso da tomografia por coerência óptica (TCO) Stratus em pacientes com lesões do trato óptico. MÉTODOS: Dois pacientes com hemianopsia homônima de longa duração decorrente de lesões do trato óptico foram submetidos a avaliação neuroftalmológica completa e tomografia por coerência óptica Stratus. RESULTADOS: Ambos pacientes demonstraram redução difusa da CFNR nos dois olhos. Nos olhos com a hemianopsia temoporal, a perda da CFNR foi difusa mas com predomínio nas áreas nasal e temporal do disco óptico, um padrão clássico da atrofia em banda do nervo óptico. Nos olhos com hemianopsia nasal observou-se perda da CFNR nos quadrantes superior e inferior do disco óptico. A perda da CFNR se correlacionou com o defeito de campo visual e com o padrão esperado de perda da CFNR nas lesões do trato óptico. CONCLUSÃO: A tomografia por coerência óptica - Stratus pode fornecer informação útil no diagnóstico das lesões do trato óptico ao identificar o padrão característico de perda da CFNR que ocorre em ambos os olhos nesta condição.


Asunto(s)
Humanos , Disco Óptico/patología , Enfermedades del Nervio Óptico/diagnóstico , Neuronas Retinianas/patología , Tomografía de Coherencia Óptica , Estudios Transversales , Disco Óptico , Reproducibilidad de los Resultados , Retina/patología , Células Ganglionares de la Retina/patología